Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages



Similar documents
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Horizontal Jet Pumps 1/3-1-1/2 HP

MODEL INSTALLATION INSTRUCTIONS

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

Project: Model: Chk d: Date: Model 32DGUII61.5S

Dry Pit Solids Handling Pumps

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

WGL20, WGL20H, WGL20F Grinder Pumps

Specifications SHA Series

APCO SLOW CLOSING AIR/VACUUM VALVES

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

Pump Maintenance - Repair

PRESSURE REDUCING CONTROL VALVE

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

1/3 HP Submersible Sump Pump with Vertical Float Switch

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Goulds Water Technology

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

Fire Pump Plan Review March 2010

Morrison Bros. Co. General Product Specifications

CRN A-F-G-E-HQQE 3x400D 50 HZ

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

Multistage high-pressure multistage centrifugal pumps

What Does A Sump Pump Do?

MAC-120HE-01 Air-Cooled Chiller

300 Series PA Pump and Cooler Assemblies

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Standard offering (pumps)

Conlift1, Conlift2, Conlift2 ph+

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Model 1210C Battery Powered Pump Shown. Description

James M. Pleasants Company

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

HORIZONTAL PUMPING SYSTEM

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

Utility Distribution Systems

MDT5N25 & MTD5N40 SERVICE PARTS

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Series description: Wilo-Drain TC 40

Vertical Pumps for the Oil & Gas Industry

Water Tec of Tucson Water Systems

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Standard Bills of Materials Commonly Ordered Models Only

OPERATION & MAINTENANCE MANUAL SUBMERSIBLE SEWAGE PUMP

HYDROSTATIC TEST PUMPS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Wilo Building Services - Price Book

Medical Air Systems: Scroll

SERVICE MANUAL. Commercial Disposers SS-50 SS-75 SS-100 SS-125 SS-150 SS-200 SS-300 SS-500 SS-750 SS-1000

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

4" SUBMERSIBLE PUMPS

Commercial Gas Furnace Upflow

FAIRBANKS NIJHUIS FIRE PUMPS.

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

BOWIE PUMPS OPERATION - MAINTENANCE

American- Darling 5¼" B-84-B-5.

08.08 Vic-Check Valves

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

TECHNICAL INFORMATION Bulletin

Section 8 Storage Tanks & Equipment

ALIGNMENT. Pump and Driver Alignment

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Flygt 3068, 50Hz. Technical Specification

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Vertical selfpriming Side-Channel Pumps Type WPV

Flygt Ball Check Valves

Pipe Cutting and Beveling Clamshells

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Tsurumi BER. Submersible Ejectors

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

REGULATORS 175/153 Series

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

45 URAI DSL Roots. Quick Specs. Also Available in: Part Number T

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Transcription:

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

2448LSG/LSGX - Series Dimensional Data 2448LSG_P2 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

2448LSG_P3 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

2448LSG_P4 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

2448LSG/LSGX - Series Electrical data MODEL H P VOLTAGE PHASE SF FULL LOAD AMPS LOCKED ROTOR AMPS THERMAL OVERLOA D TEMP STATOR WINDING CLASS CORD LENGTH FT DISCHARGE AUTOMATIC 2448LSG202 2 208/230 1 1.0 15 53 135 C B 25 1-1/4 NPT YES 2448LSGX202 2 208-230 1 1.0 15 53 135 C B 25 1-1/4 NPT YES 2448LSG/LSGX - Series Technical Data TANK CAPACITY GUIDE RAIL GUIDE RAIL BASE / DISCONNECT (GR20) INLET HUB DISCHARGE PIPING JUNCTION BOX ALARM IMPELLER PAINT MAX LIQUID TEMP MAX STATOR TEMP THERMAL OVERLOAD POWER CORD TYPE MOTOR HOUSING VOLUTE SHAFT HARDWARE ORINGS MECHANICAL SEAL MIN BEARING LIFE WOUND FIBERGLASS WITH ANTI FLOATATION FLANGE FIBERGLASS COVER STANDARD, STEEL COVER OPTIONAL 93 GALLON TOTAL BASIN VOLUME (PUMP CYCLE = 13.5 GALLONS) STANDARD SCHEDULE 40 GALVANIZED OPTIONAL SCHEDULE 40 STAINLESS STEEL CAST IRON 4 WITH FLANGE GASKET AND PIPE SEAL SCHEDULE 80 PVC NEMA 4X OUTDOOR WITH 6-20R 230V RECEPTICLE NEMA 4X OUTDOOR ALARM WITH VISUAL AND AUDIBLE (80 DBI) ALARM 300 SERIES S.S. POWDERCOATING 140 F/ 60 C 275 F/ 135 C 275 F/ 135 C SJOOW CLASS 25 CAST IRON CLASS 25 CAST IRON 300 SERIES S.S. STAINLESS BUNA N UNITIZED SILICON CARBIDE 50,000 HRS 2448LSG_P5 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

2448LSG/LSGX - Series Specifications 1.01 GENERAL: The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) centrifugal grinder pumps as specified herein. The pump models covered in this specification are Series LSG/LSGX200 single phase grinder pumps. The pump furnished for this application shall be model as manufactured by Liberty pumps. 2.01 OPERATING CONDITIONS: Each submersible pump shall be rated at 2 hp volts phase 60 Hz. 3450 RPM. The unit shall produce G.P.M. at feet of total dynamic head. The submersible pump shall be capable of handling residential and commercial sewage and grinding it to a fine slurry enabling it to be pumped over long distances in pipelines as small as 1.25" in diameter. The LSG series single stage submersible pump shall have a shut-off head of 110 feet and a maximum flow of 50 GPM @ 10 feet of total dynamic head. The LSGX series two stage submersible pump shall have a shut-off head of 185 feet and a maximum flow of 38 GPM @ 10 feet of total dynamic head. The pump shall be controlled with: A piggy back style on/off float switch (Single Phase Only). 3.01 CONSTRUCTION: Each centrifugal grinder pump shall be equal to the certified Series LSG/LSGX Grinder pumps as manufactured by Liberty Pumps, Bergen NY. The castings shall be constructed of class 25 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with a dual seal arrangement. The first seal is a double lip seal molded in FKM fluoroelastomer or Buna N. The second / main seal shall be a unitized hard face silicon carbide seal with stainless steel housings and spring. The upper and lower bearing shall be capable of handling all radial thrust loads. The lower bearing shall have the additional ability to handle the downward axial thrust produced by the impeller and cutters by design of angular contact roller races. The pump housing shall be of the concentric design thereby equalizing the pressure forces inside the housing which will extend the service life of the seals and bearings. Additionally there shall be no cutwater in the housing volute in order to discourage the entrapment of flowing debris. The pump shall be furnished with stainless steel handle having a nitrile grip. 4.01 ELECTRICAL POWER CORD The submersible pump shall be supplied with 25 feet of multiconductor power cord. It shall be cord type SJOOW (1-phase), capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord. 2448LSG_P6 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

5.01 MOTORS Single phase motors shall be oil filled, capacitor start / capacitor run, class B insulated NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not exceed 135 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for protecting the motor. The capacitor circuit shall be mounted internally in the pump. Single phase motors shall have an integral solid state starting circuit switch for switching the start winding off. 6.01 BEARINGS AND SHAFT An upper radial and lower thrust bearing shall be required. The upper bearing shall be a single ball / race type bearing. The lower bearing shall be an angular contact heavy duty ball / race type bearing, designed to handle axial grinder pump thrust loads. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The bearing system shall be designed to enable proper cutter alignment from shut off head to maximum load at 10 ' of TDH. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.670". 7.01 SEALS The pump shall have a dual seal arrangement consisting of a lower and upper seal to protect the motor from the pumping liquid. The lower seal shall be a FKM fluoroelastomer OR Buna N molded double lip seal, designed to exclude foreign material away from the main upper seal. The upper seal shall be a unitized silicon carbide hard face seal with stainless steel housings and spring equal to Crane Type T-6a. The motor plate / housing interface shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be a investment cast stainless steel impeller, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be keyed and bolted to the motor shaft. 9.01 CUTTER MECHANISM The cutter and plate shall consist of 440 stainless steel with a Rockwell C hardness of 55-60. The stationary cutter plate shall have specially designed orifices through it, which enable the slurry to flow through the pump housing at an equalized pressure and velocity. The stationary cutter shall consist of V shapes to maximize cutting action and arc shape exclusion slots to outwardly eject debris from under the rotary cutter. The rotary cutter shall have (4) blades and be designed with a recessed area behind the cutting edge to prevent the accumulation and binding of any material between rotary cutter and the stationary cutter. The cutting system must incorporate close tolerances for optimum performance. Ring or radial cutters, or those that grind on the outside circumference of shall not be considered equal. 10.01 CONTROLS All single phase units can be supplied with CSA and UL approved automatic wide angle tilt float switches. The switches shall be equipped with piggy back style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. Manual Pumps are operable by means of a pump control panel. 11.01 PAINT The exterior of the casting shall be protected with Powder Coat paint. 12.01 SUPPORT The pump shall have cast iron support legs, enabling it to be a free standing unit. The legs will be high enough to allow solids and long stringy debris to enter the cutter assembly. 2448LSG_P7 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

13.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 14.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile grommets. The Discharge piping shall be schedule 80 PVC and furnished with a check valve and PVC shut-off ball valve. The tank shall be wound fiberglass or roto-molded plastic. An inlet hub shall be provided with the fiberglass systems. Stainless steel Guide Rail Zinc plated steel Guide Rail "diameter of basin size "height of basin size "distance from top of tank to discharge pipe outlet Fiberglass cover Structural foam polymer cover Steel cover Simplex System with Outdoor panel and alarm Duplex System with Outdoor panel and alarm Separate Outdoor Alarm Remote Outdoor Alarm 15.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction. 16.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 17.01 WARRANTY Standard limited warranty shall be 3 years. 2448LSG_P8 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.