Slim Contour Unit Cooler

Similar documents
Low Profile Unit Cooler

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

SECTION MORTUARY REFRIGERATORS

CARRIER REFRIGERATION EQUIPMENT AND PARTS

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

SWIMMING POOL HEAT PUMP

How To Understand Evaporator

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

HOSHIZAKI AMERICA, INC.

Table Z. Troubleshooting Chart for Air Conditioners. Cause

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

air conditioners how to choose a cooling system

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

KRAMER ELECTRIC DEFROST EVAPORATORS LPE - LVE - MSE - CSE - HSE - CED - KED INSTALLATION, START-UP AND MAINTENANCE INSTRUCTIONS

Troubleshooting Your Refrigerator

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

york air-conditioning products Residential & VRF News 2015

Air Conditioner Maintenance

Local Dealer:

Central Air Conditioner

123 street Salt Lake City, Utah 84092

Make Your Own SNOWBREEZE AC For Rs.1500 ($30) Can be converted into an energy saving and humidified room heater in winter

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Single Zone LCD Thermostat Operating Instructions

DESIGN STANDARDS SECTION

HVAC Repair and Maintenance Strategies by Ron Prager

ARMSTRONG AIR HEAT PUMPS

Air Conditioning 101. STN Presentation AC101

Solving the Problem of Motor Protection from Moisture, Water and Dust in Commercial Refrigerators.

CEILING CASSETTE FAN COIL UNIT

SECTION HEAT PUMPS

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

How Ground/Water Source Heat Pumps Work

TIPS ON ENERGY SAVING

PACKAGE AIR CONDITIONERS REPLACEMENT PARTS MANUAL

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

General Information on Starting a Restaurant Business in Alabama

Commercial Refrigeration Temperature and Defrost Controls

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

EHDC. Cooling system for Data Center and server cabinets.

Dehumidification Frequently Asked Questions

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Why Daikin? 2015 Houston, Texas USA

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

RUUD AIR CONDITIONERS & HEAT PUMPS

In Row Cooling Options for High Density IT Applications

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

THREE. Heating and Cooling

Energy Efficiency. Energy Efficient Home Cooling:

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

HEATING, VENTILATION & AIR CONDITIONING

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Comfort you can count on.

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Element D Services Heating, Ventilating, and Air Conditioning

Air-Conditioning Buying Guide

FULL DC INVERTER SYSTEMS

Evaluate, Clean, and Tune Guidance

Installer s Guide 18-AH39D1-13

Reducing the Cost of Keeping Office Data Centers Cool

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Chilled Water HVAC Systems

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition

Cooling/Heat Pump Convertible Air Handlers

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Ductless Heat Pumps. Gary Nordeen January

Automobile Air Conditioning Primer


Air Conditioning System

Glossary of Heating, Ventilation and Air Conditioning Terms

ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

How does solar air conditioning work?

Inverter Air Conditioning for Light Commercial Use

ECO-AIR AIR CONDITIONING

Slim Line KUC Unit Coolers 60Hz

Evaporator Coil Installation Instructions

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Innovation in air conditioning and heating

Heat Pump USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL HEAT PUMP

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

Transcription:

Slim Contour Unit Cooler with Modular Cassette Design ULA Models Questions & Answers

Table of Contents What is the Slim Contour unit cooler?... 2 Why was this product developed?... 2 What are the key benefits of this product?... 3 How does the height compare to that of a standard unit cooler?... 4 What options are avaliable with this product?... 4 How does the capacity compare to current products?... 4 Are these units avaliable for low temperture applications?... 5 Will there be a challenge brazing with the ABS resin?... 5 What are the housings made from?... 5 How durable is this material in a cold enviorment?... 5 When would I use the Slim Contour unit cooler vs. either the standard Low Profile or Center Mount unit cooler?... 6 How easy is it to remove the units cassettes?... 6 Is this a unique motor? Where will I be able to find a replacement?... 6 Can I replace the cassette instead of replacing the motor?... 6 Do I need to use special cleaners to clean the panels and housing?... 7 How is the Slim Contour priced compared to other walk-in unit coolers?... 7 Does the Slim Contour unit cooler s benefits include energy efficency or substainability features?... 7 Can you clean the grill?... 7 Questions & Answers Q1: WHAT IS THE SLIM CONTOUR UNIT COOLER? A1: Heatcraft s latest product in our walk-in unit cooler portfolio the Slim Contour unit cooler is an innovative new product with a very low profile that maximizes storage space within a walk-in cooler and incorporates design features that enhance serviceability. The design integrates an advanced air mover with a modular, high strength resin housing and a refrigeration duty optimized small diameter coil design to provide a maximum cooling performance with a ultra low height of 11. Q2: WHY WAS THIS PRODUCT DEVELOPED? A2: Foodservice operators have always struggled with the amount of space taken up by traditional walk-in unit coolers. These units often take up valuable storage space within a walk-in cooler, and in addition, have a drain line that extends up to four to six inches beneath the unit that further interferes with storage and is often damaged or broken as a result. Servicing existing units is often also a challenge as it is not easy to access the coil and drain pan for cleaning with traditional walk-in unit coolers. Given the increased focused on food safety, it is critical that foodservice operators be able to clean and service the unit in an easy and quick manner. The Slim Contour unit cooler was designed to specifically address these customer needs. 2

Q3: WHAT ARE THE KEY BENEFITS OF THIS PRODUCT? A3: The Slim Contour unit cooler is designed to maximize storage space and improve serviceability of walkin coolers. Reduced Unit Height: The Slim Contour unit not only has a low unit height of 11, but couples that with a drain line design that comes straight out of the unit and thus not in the way of foodservice operators. Improved Serviceability:The Slim Contour units are a hybrid design, made from high strength resin housings and metal, are modular and are easily removed to expose the coil and drain pan for easy cleaning. Modular, Removable air mover cassette: Allows for easier access to coils and drain pan for for cleaning. Cassettes can be taken to a warmer environment for motor servicing. Removable fan guards: The fan guards are also removable for easy cleaning and are dishwasher safe. Mechanical and Electrical Service components on same side: Allows for easier and faster service and installation with access to all critical electrical and mechanical components on one side. 3

Q4: HOW DOES THE HEIGHT COMPARE TO THAT OF A STANDARD UNIT? A4: Dimensional comparison of the Slim Contour unit cooler and a standard low profile unit is shown below: At 11 the Slim Contour unit cooler is about 5 lower in height than a standard unit cooler. When incorporating the drain line, it is about a 10 reduction in height vs. the standard unit. 10 10 Q5: WHAT OPTIONS ARE AVAILABLE WITH THIS PRODUCT? A5: The unit is available with the following options: Factory Mounted Components o Liquid solenoid valve o TXV o Heatcraft Beacon II Refrigeration System Q6: HOW DOES THE CAPACITY COMPARE WITH THE CURRENT PRODUCTS? A6: The capacity of the Slim Contour unit cooler is comparable to the capacity of our existing Walk-in unit cooler products. A summary of the capacity points for our Slim Contour unit cooler and Low Profile and Center Mount unit coolers is shown below. 4

Q7: ARE THESE UNITS AVAILABLE FOR LOW TEMPERATURE APPLICATIONS? A7: The first phase of the product release of the Slim Contour unit cooler will be for medium temperature applications using air defrost. Q8: WILL THERE BE A CHALLENGE BRAZING WITH THE ABS RESIN? A8: The unit is a hybrid design of metal and ABS resin. As such, the key structural and refrigeration connections are mounted to the metal structure. For brazing operations the ABS side panel can be removed as shown below, leaving only metal components in the surrounding area and no ABS components that will be exposed to the heat. Q9: WHAT ARE THE HOUSINGS MADE FROM? HOW DURABLE IS THIS MATERIAL IN A COLD ROOM ENVIRONMENT? A9: The unit is a hybrid design incorporating metal and ABS resin. Metal components are used to provide structural support and the ABS resin is used in the housing and side panels to house the motor and air channels. The ABS resin is a durable material that is used commonly in walk-in cooler and freezer applications in Europe and Australia. The ABS resin material chosen has a 21 CFR rating for NSF which qualifies it to be in splash zone. 5

Q10: WHEN WOULD I USE THE SLIM CONTOUR UNIT COOLER VS. EITHER THE STANDARD LOW PROFILE UNIT COOLER OR A CENTER MOUNT DESIGN? A10: The Slim Contour unit cooler builds to our existing portfolio of walk-in unit coolers by providing additional functionality not currently available with existing low profile unit coolers or center mount products. A summary of the features and advantages of each product is shown in the table below: Low Profile Slim Contour Center Mount The industry standard for walk-in cooler applications. Offering the broadest capacity range, from 4,000 to 37,000 BTUH, the low profile unit cooler is designed for maximum air flow and cooling capacity inside a walk-in cooler. Optimized for air defrost (medium temperature) applications, the Slim Contour unit cooler is ideally suited for installations where storage space is critical and a higher pull down capability is desired. Available in air or electric defrost, ideal for tight storage situations because they are ceiling mount and have a height of less than 9 allowing for maximum headroom in a cooler. The center mount design provides a moderated, evenly distributed air flow throughout the box. Q11: HOW EASY IS IT TO REMOVE THESE CASSETTES? A11: The modular cassettes are easy to remove, as depicted in the pictorial below. Q12: IS THIS A UNIQUE MOTOR? WHERE WILL I BE ABLE TO FIND A REPLACEMENT? A12: The air mover used for the Slim Contour unit cooler is an external rotor motor with an integrated blower wheel. While not commonly used in refrigeration applications this type of motor is common in HVAC applications. Replacement motors will be available via our InterLink service parts organization initially and ultimately through our refrigeration wholesale distribution partners. InterLink can be reached at 800.686.7278 or via e-mail at interlinkparts@heatcraftrpd.com Q13: CAN I REPLACE THE CASSETTE INSTEAD OF REPLACING THE MOTOR? A13: Replacing the cassette in lieu of the motor is an option that will be available to customers. This affords the customer or service contractor an easier service option, as cassettes can be swapped out in less than five minutes. A restaurant operator can potentially store these cassettes at their location and have the ability to replace cassettes immediately, thus maintaining walk-in cooler temperatures and product integrity. 6

Q14: DO I NEED TO USE SPECIAL CLEANERS TO CLEAN THE PANELS AND HOUSING? No special cleaners are required. Standard cleaners used to clean traditional unit coolers work well and do not harm the panels or housings. Q15: HOW IS THE SLIM CONTOUR UNIT COOLER PRICED COMPARED TO OTHER WALK-IN UNIT COOLERS? A15: The Slim Contour unit cooler has unique design and serviceability features that are ideally suited for customers that require additional space within the walk-in, and require the air throw and pull down capacity to be maintained. As such, the Slim Contour unit cooler is competitively priced with Heatcraft s existing portfolio of walk-in unit coolers. The pricing of the unit coolers is shown below Model Capacity No. of Fans Price ULA041 4,100 1 $2,250 ULA050 5,000 1 $2,375 ULA072 7,200 2 $3,500 ULA100 10,000 2 $3,950 ULA132 13,200 3 $4,650 ULA153 15,300 3 $5,625 Q16: DO THE SLIM CONTOUR UNIT COOLER BENEFITS INCLUDE ENERGY EFFICIENCY OR SUSTAINABILITY FEATURES? A16: The Slim Contour comes with EC (Electronically Commutative) motors standard and an optimized small diameter coil. The coil reduces refrigerant required by up to 42%, compared to standard walk-in unit coolers. The ABS housing components are also 100% recyclable. Q17. CAN YOU CLEAN THE GRILL? A17. The grill can be cleaned by simply removing it from the cassette. Because it is made out of the same plastic as in current walk-in unit coolers, you can use your standard cleaning methods to remove dirt & grime, and is durable enough to be placed in the dishwasher. 7

2175 West Park Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 Fax: 770.465.5900 heatcraftrpd.com