DMA-1 Direct Mercury Analyzer



Similar documents
MILESTONE H E L P I N G C H E M I S T S

FMA-80 Fluorescence Mercury Analyzer

DMA-80 Direct Mercury Analyzer

MILESTONE START D. Microwave Digestion System

M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE

Milestone Warranty. ETHOS One. The Best Choice in Microwave Sample Preparation MILESTONE

MILESTONE. RotoSYNTH. Rotative Solid-Phase Microwave Reactor

MILESTONE. SynthWAVE. The Game Changer in Microwave Synthesis

MILESTONE. MicroSYNTH. Microwave Synthesis Labstation

Mercury Determination in House Dust, NIST SRM-2584, USEPA Method 7473, Using the Teledyne Leeman Labs Hydra II C Combustion CVAAS

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

M I C R O W A V E E X T R A C T I O N S Y S T E M THE NEW MILESTONE MILESTONE

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

The art of elemental analysis

The Sievers 900 Series TOC Analyzers

ORGANIC SAMPLE PREPARATION

MILESTONE. NEOS Rapid, Solvent-Free Microwave Extraction (SFME) of Essential Oil The Microwave Clevenger TM

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Nitrogen analysis is elementary

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

4.2 Bias, Standards and Standardization

DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS

NITRIC OXIDE and NITROGEN DIOXIDE 6014

Quality Assurance for the Analysis of Steel by Gas Component Analysis

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Elemental analyzer multi EA 5000

SCION SQ Series GC-MS

Assessing the Changes Required by the Industrial Boiler MACT Regulations

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

TRL-onlineTOC Monitor is designed for monitoring carbon content in

Innovative Technology Verification Report

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

INTERNATIONAL OLIVE COUNCIL

73 Series Spectrophotometers

OLIVÉR BÁNHIDI 1. Introduction

Certificate of Analysis

German engineering under high pressure

Accurate Determination of Lead in Different Dairy Products by Graphite Furnace Atomic Absorption Spectrometry

Elemental Analyses by ICP-AES

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

Bridging the analytical gap

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

Measurement & Analytics Measurement made easy. MB3600-CH10 FT-NIR oleochemicals analyzer Pre-calibrated for Iodine Value (IV) and %Trans Fat

Heavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy

MD SD MS SS MH SH ML SL MT ST

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

State of the Art (SOTA) Manual for Boilers and Process Heaters

Amino Acid Analyzer L-8900

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

MPA. Innovation with Integrity. Multi Purpose Analyzer FT-NIR

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Physical & Chemical Properties. Properties

UVC LEDs for. Environmental Monitoring

QA/QC. Standard methods in field. QA/QC in the field. QA/QC in analysis

Advanced Solutions for Gas Monitoring

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

USE OF REFERENCE MATERIALS IN THE LABORATORY

Highly efficient flue gas analyzer

How To Test For Contamination In Large Volume Water

Colorimetric Determination of Iron in Vitamin Tablets

Continuous Emissions Monitoring - Program 77

Appendix 5 Overview of requirements in English

Determination of Total Suspended Solids (TSS) and Total Volatile Solids (TVS) in Waters of Fresh/Estuarine/Coastal Waters

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Chemical reactions allow living things to grow, develop, reproduce, and adapt.

METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)

Total Dissolved Solids:

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

Thermo Scientific ConFlo IV Universal Interface

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

Performance and advantages of qnmr measurements

How To Run A Gas Plant

LIST OF EQUIPMENT IN CHEMISTRY LABORATORY

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

Gas sensors for greenhouse measurements

Calibration Certificate

OEM Optical Competences. Solutions for Optical OEM Applications in Liquid Analysis.

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

MATERIAL SAFETY DATA SHEET (MSDS)/SAFETY DATA SHEET (SDS)

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

Determination of the Mass Percentage of Copper in a Penny. Introduction

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

US Safety Data Sheet GEAR OIL SAE 10W/30 GEAR OIL SAE 10W/30

Department of Environmental Engineering

Transcription:

DMA-1 Direct Mercury Analyzer www.milestonesrl.com MILESTONE H E L P I N G C H E M I S T S

8 good reasons to choose the milestone DmA-1 1. no sample preparation 2. ease of use 3. lowest cost of analysis The DMA-1 does not require any sample preparation or other wet chemistry prior the analysis. This means ease of use, low running cost and no need for hazardous chemicals to purchase, handle and dispose. Just weigh your sample, load it onto the instrument and press start. The DMA-1 is so simple to use that it can be operated in the field, not only in the analytical laboratory. Ease of use, speed of analysis, catalyst and amalgamator long lifetime, sample boats durability and the possibility of using air as combustion and carrier gas minimize the DMA-1 cost of analysis.

4. Best analytical performance Combining an innovative mercury measuring system with a unique optical path spectrophotometer, the DMA-1 achieves a detection limit as low as 0,003 nanograms of mercury and is capable of measuring up to 1.500 nanograms of mercury, equivalent to a concentration of 15 mg/kg (15 ppm) on a 100 mg sample analysis. ˆ1=1.2722 =4.10s Typical DMA-1 absorbance profile. The 1 st peak is related to the more sensitive longer cell, while the 2 nd peak corresponds to the shorter cell. ˆ2=0.1611 =5.55s 5. Official methods compliance The DMA-1 is compliant with the US EPA method 7473 (Mercury in solids and solutions by thermal decomposition, amalgamation, and atomic absorption spectrophotometry), with ASTM method D-6722-01 (Total mercury in coal and coal combustion residues) and ASTM method D-7623-10 (Total mercury in crude oil). 02 04 06 08 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Time [s] 6. High productivity The DMA-1 is incredibly fast. Sample weight is automatically transferred from the analytical balance to the instrument, and a complete analysis -start to finish, takes just 5 minutes. 7. easy maintenance All the DMA-1 components, such as the catalytic furnace, amalgamator and spectrophotometer, are easily accessible for routine cleaning and maintenance. 8. largest installed base With over 1300 units installed in 80 different Countries worldwide, Milestone is the acknowledged market leader in direct mercury determination. Our extensive experience enables us to provide the highest level of application and service support.

milestone DmA-1 How it works The Milestone DMA-1 is a direct mercury analyzer of solid, liquid, and gas samples. Analysis time is 5 minutes only and no sample preparation is required. The DMA-1 is based on the principles of sample thermal decomposition, mercury amalgamation and atomic absorption detection. The DMA-1 shares the same technology of the Milestone DMA-80, the most successful direct mercury analyzer in the market with over 1300 units installed in 80 different Countries worldwide. The sample is weighed into a quartz vial, and its weight automatically transferred from the analytical balance to the DMA-1. Sample vial is then loaded onto the instrument. Sample is dried and then thermally decomposed in an oxygen-rich stream. Mercury and other combustion products are released and flown through the catalyst, where all interfering substances, such as halogens and nitrogen or sulfur oxides, are eliminated. Mercury is selectively trapped by gold amalgamation, while other combustion by products are flushed off. The amalgamation furnace is heated and mercury is rapidly released. Mercury is finally carried into multiple measuring cells positioned along the optical path of the spectrophotometer, and quantitatively measured by atomic absorption at 253,65 nm.

DmA-1 user interface The DMA-1 is operated via a compact control terminal with easyto-read, bright, full-color, touch screen display or, alternatively, by a Windows-based computer. The terminal is provided with multiple USB and RS-232 ports for direct printouts of methods and runs, and for interfacing the instrument to an external balance. The terminal runs Milestone s unique EasyCONTROL software, providing simple and intuitive, but extremely flexible and powerful control over the analytical process. All sample parameters, including furnace temperatures, method profiles, absorbance signals, results, and calibrations are saved. They can be viewed, easily transferred using a USB memory stick or integrated to LIMS Laboratory Information Management Systems. EasyCONTROL software includes the unique AutoBLANK feature. If, following the analysis of a sample with a very high mercury content, the pre-set blank level is exceeded; EasyCONTROL will automatically run blank cycles until the pre-set blank level is achieved. EasyCONTROL allows the operator to designate certain samples as reference, or QC samples. Once a sample is designated as a reference, a known concentration value is entered. If the analysis of that sample yields a concentration outside the acceptable range specified by the operator, EasyCONTROL can be pre-set to either continue, stop, or pause the analysis of the remaining samples. EasyCONTROL software is fully compliant with FDA regulations 21 CFR Part 11.

milestone DmA-1 analytical performance Accuracy The DMA-1 produces accurate results over a wide dynamic range and on a variety of different matrices. The results below refer to analyses on solid certified reference materials with a mercury concentration ranging from 5 μg/kg to nearly 5 mg/kg. Sample Certified (μg/kg) DMA-1 (μg/kg) NIST 1568a Rice Flour 5,8 ± 0,5 5,9 ± 0,2 BCR-277R Estuarine Sediment 128 ± 17 121 ± 2 DORM-4 Fish Protein 410 ± 55 375 ± 3 NIST 2781 Domestic Sludge 3.640 ± 250 3.757 ± 88 BCR EC 680k Polythene 4.640 ± 220 4.780 ± 94 sample matrix The DMA-1 produces matrixindependent results. The instrument is calibrated using aqueous standards and then analyzes organic and inorganic solid samples. Just one method is used to analyze a variety of different matrices making the DMA-1 extremely easy to use. Precision The DMA-1 provides reproducible results over a broad range of samples, such as polymers, food and feed, and oils, for instance. Crude Oil average=22,15 sd=0,53 RSD=2,4% Hg concentration 265 250 235 220 205 190 175 1 2 3 4 5 6 Run

sample amount stability Up to 1,5 grams of solid or 1,5 ml of liquids can be analyzed. This is particularly important for the analysis of heterogeneous materials or for samples with a very low mercury concentration. The graphic shows results obtained on NIST 2709 (San Joaquin Soil), a certified reference material with known mercury content of 1.32-1.48 mg/kg. Hg concentration 1,6 1,2 0,8 0,4 0,1 0,5 1,0 1,5 Run The instrument calibration lasts for months of operation, and the results are stable over time. memory effect The DMA-1 does not virtually suffer from any memory effect. The instrument software features the Autoblank function, by which the user preset a satisfactory blank level. If that level is exceed the instrument automatically runs blank cycles until the expected level is reached. This is important when analyzing a series of unknown samples. ˆ1=1.1273 =5.15s ˆ2=0.0758 =8.75s ˆ1=0.0021 =3.60s The graphic shows the absorbance peak for a 1-mg/kg mercury solution and the subsequent profile of blank run.

Gas analysis sorbent traps Milestone Sorbent Traps expand the capabilities of the DMA-1, enabling the measurement of mercury in gases. Simply sample the gas, through a dedicated mass flow controller, using the Sorbent Traps, and load them onto the DMA-1. Total mercury (elemental and oxidized forms) is quantitatively measured in 5 minutes. Sorbent Traps are reusable and extremely easy to operate. UNI EN ISO 9001: 2008 CERTIFIED MILESTONE H E L P I N G C H E M I S T S MILESTONE Srl Via Fatebenefratelli, 1/5-24010 Sorisole (BG) - Italy Tel: +39 035 573857 - Fax: +39 035 575498 www.milestonesrl.com - email: analytical@milestonesrl.com MILESTONE INC. 25 Controls Drive - Shelton, CT 06484 - USA Tel: (203) 925-4240 - Toll-free: (866) 995-5100 - Fax: (203) 925-4241 www.milestonesci.com - email: mwave@milestonesci.com MILESTONE GENERAL K.K. KSP, 3-2-1, Sakado - Takatsu-Ku, Kawasaki 213-0012 - Japan Tel: +81 (0)44 850 3811 - Fax: +81 (0)44 819 3036 www.milestone-general.com - email: info@milestone-general.com MLS GmbH Auenweg 37 D-88299 Leutkirch im Allgau - Germany Tel: +49 (0)7561 9818-0 - Fax: +49 (0)7561 9818-12 www.mls-mikrowellen.de - email: mws@mls-mikrowellen.de In Your Country: CAT344EN-001