MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB



Similar documents
MONO BLOCK DIRECTIONAL CONTROL VALVE TS

LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

Series PVP Variable Volume Piston Pumps

Hydraulic Flow Control Valves

Unit 24: Applications of Pneumatics and Hydraulics

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Vickers. Valves. CM2, CM11, RM3 & FM3 Control Valves. For Mobile Equipment. Revised 4/96

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Check Valves Valve locator

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

ROTARY GEAR FLOW DIVIDERS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Example. Fluid Power. Circuits

Control block EDD Modular Directional Valve

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Unit 24: Applications of Pneumatics and Hydraulics

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

VHO/VQ Single, Double & Triple Vane Pumps

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

PART 2 FORKLIFT HYDRAULIC SYSTEM

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Solenoid Operated Directional Valves

Pressure Relief and Regulating Valves

COUNTERBALANCE VALVES

PVH131/141 Variable Displacement Piston Pump - 11 Design

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

Quiz On Information Learned From Chapter 1

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

HYDROSTATIC TEST PUMPS

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

Variable Displacement Pump AA10VSO

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

Hi-Cyclic. 2, 3 and 4-Way Directional Control Valves for Pneumatic and Hydraulic Service

The Secret of Hydraulic Schematics. BTPHydraulics

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

Solenoid Operated Directional Valves

scx-180 Control focused technology driven SCX valve series SSL-1000 REV 04/09 - SUPERCEDES REV 01/08

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Directional Control Valve Equipment for Front End Loaders

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Coreless Spin-On Filters. 12AS/50AS Series

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

PRESSURE REDUCING CONTROL VALVE

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Hydraulic Trouble Shooting

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Unit 24: Applications of Pneumatics and Hydraulics

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Butterfly Valves PN 6/10/16 for flanged connection

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Chapter 5: Flow Valves

Electro-Pneumatic Bus Door Control Mechanism

2/2 and 3/2 Way Size 6 Seat Valves

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Operating, Installation, and Maintenance Instructions

Streaming Potential System (SPT1000, SPD1000)

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Model 1210C Battery Powered Pump Shown. Description

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Flow divider (flow distributor), type TQ

SIMPLIFIED VALVE CIRCUIT GUIDE

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Rexroth Hydraulic Pump A10VO Series User Manual

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

Unit 24: Applications of Pneumatics and Hydraulics

Fisher 377 Trip Valve

Spare Parts Program. Parts, Consumables & Accessories superproductsllc.com

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

SIMPLIFIED VALVE CIRCUIT GUIDE

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

SOLENOID VALVES 3-4 WAY

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

Flygt Ball Check Valves

VSO MAX HP High Flow Proportional Valve

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

ACCUMULATOR INSTALLATION

Transcription:

MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP CHECK prevents the load from dropping when the spool is shifted. FOURTH POSITION FLOAT allows spool movement to a fourth position and makes all ports common to each other (last spool only). PRECISION GROUND IOSSO PLATED SPOOL that assures long life. SPECIFICATIONS: MATERIALS: 18 gpm (68. lpm) Nominal Capacity. Rated up to 3 psi (27 bar). Port Sizes-Inlet/Outlet #12SAE (1-1/16-12). -Work Ports #1SAE (7/8-14). 1 Micron Filtration Recommended. Weight -TS1 = 9 lbs. (4.1 kg). -TS2 = 14 lbs. (6.4 kg). -TS3 = 2 lbs. (9.1 kg). Page D-34 Cast Iron Body Buna N O Rings IOSSO Plated Steel Spools Black Nylon Ball Knob 12-13

TS GENERAL FORMATION The Brand, mono block directional control valve is available in one (TS1), two (TS2) and three (TS3) spool configurations. This valve was designed for applications in which one valve is required to operate separate circuits independently. The TS offers parallel, tandem center 4-way, open center 4-way(motor spool), and tandem 3-way spools. The valve is also field convertible to closed center and power beyond. SPOOLS The tandem three-way (T3) powers a cylinder in one direction. Tandem center 4-way (T) powers a cylinder or a motor in both directions. Closed center 4-way (C) blocks all ports in neutral and must be used with a pressure compensated pump. Open center 4-way (O) connects all ports to tank when in neutral. SPOOL ACTION Three position detent (D) holds the spool in neutral and both active positions. Rotary friction detent (E) applies friction to the spool as it is rotated so that the handle does not rotate when the handle is released, a detent groove clearly indicates neutral position (only available on TS1). Friction detent (F1) applies friction to the spool so that the spool does not move when the handle is released, a detent groove clearly indicates neutral position. Spring center (S) returns the handle to neutral when the handle is released. Spring center detent (SD) springs back to neutral from one position and is mechanically detented P to A. Spring center hydraulic detent (SH) springs back to neutral from P to B position and pressure release detent in the other direction when the cylinder completes its return stroke (P to A in detent and 8-1 psi (55 to 69 bar) kick-out). Fourth position float (K) is similar to spring center except it has a fourth position that makes all ports common to each other (last spool section only). Normally open electric switch (WO) is used with (S), (F1) and (D) options. Normally closed electric switch (WC) is used with (S), (F1) and (D) options. The electric switches can be used on the TS1, TS2 and TS3 (first and third spool only). ACTUATORS Lever handle (L) pressurizes the B port when the handle is pushed towards the valve body. Lever handle (J) pressurizes the A port when the handle is pushed towards the valve body. Rotary handle (H) is used to rotate spool in or out. No actuator (N) is used when it is necessary to connect the spool to an external actuator (L type spool). No actuator (M) is used when it is necessary to connect the spool to an external actuator (J type spool). OPTIONS Power beyond (W) offers high pressure carryover for valves down stream. The TS series is also field convertible to power beyond. Area differential relief cartridge (B) is available in pressure intervals of 1 psi (6.9 bar). GENERAL CONVERSION FORMATION NOTE: The standard 1, 2 and 3 spool castings with (O) or (T) spools are assembled at the factory with the TS315 plug in the 1SAE (7/8-14) (1) top port. TS315 1 2 12SAE LET PORT 3 CLOSED CENTER CONVERSION To have the casting in closed center operation, both the top port (1) and internal port (2) must be plugged. Take the TS315 plug from the top port (1) and insert it into the internal port (2). Then plug the top port (1) with any std. SAE plug (7/8 14) or purchase a plug from the factory. Closed center blocks Pump only, the condition of ports A and B depend on the spool type. (See illustration above) POWER BEYOND CONVERSION To convert the valve to power beyond operation, take the TS315 plug from the top port (1) and insert it into the internal port (2). Next, plumb a #1 SAE ;fitting from the top port (1) to the adjoining valve. Lastly, run a line from the #12 SAE outlet port (3) to the reservoir. (See illustration above) Page D-35

TS EXAMPLES OF COMMON MODEL CODES: TS112TSJBW Single spool valve, tandem center 4-way spool (T), spring center (S), lever handle (J), area-diff. relief cartridge (B) and power beyond (W). TS212TDTSJB Two spool valve, the first section has a tandem center 4-way spool (T) with three position detent (D), the second section has a tandem center 4-way spool (T) with spring center (S), lever handles (J), and area-diff. relief cartridge (B). TS312TSTSTKJ... Three spool valve, the first and second sections have a tandem center 4-way spools (T) with spring center (S), the third section has a tandem center 4-way spool (T) with fourth position float (K) and lever handles (J). TS CREATG A MODEL CODE FOR TS S: T S 12 VALVE SERIES: 1 One spool 2 Two spool 3 Three spool SPOOL (First section): T3 Tandem 3-way T Tandem center 4-way C Closed center 4-way O Open center 4-way SPOOL ACTION: D Three position detent E Rotary friction detent (TS1 only) F1 Friction detent S Spring center SD Spring center detent (P to A) SH Spring center / hydraulic detent K Fourth position float WO Norm. open elec. switch WC Norm. closed elec. switch OPTIONS: W Power beyond B Area-differential relief cartridge Omit No relief or power beyond HANDLE OPTION: L Lever handle (B port is active when handle is pushed) J Lever handle (A port is active when handle is pushed) H Rotary handle (used in conjunction with rotary friction detent) N No actuator (L type spool) M No actuator (J type spool) REPEAT SPOOL AND SPOOL ACTION FOR THIRD SECTION: REPEAT SPOOL AND SPOOL ACTION FOR SECOND SECTION: TS COMPLETE LIST OF OPTIONS AND ACCESSORIES: 34R1... Area differential relief cartridge set at 1 psi (69. bar). (Available in pressure setting increments of 1 psi (6.9 bar), please specify desired setting as per this example) TS-FL... Fourth position float, must be used on last spool of TS2 and TS3. TS-HJ... TS handle kit with ball knob. (One per spool) TS-HJBL. TS handle kit double bend, away, offset left with ball knob. (One per spool) TS-HJBR. TS handle kit double bend, away, offset right with ball knob. (One per spool TS-HJS. TS straight handle kit with ball knob. (One per spool) TS-K Seal kit for TS series. (One, two or three spools) TS3HL-K Handle linkage kit for TS3. (Three linkages per kit) TS-NB.. Plug for relief cavity. SDC-D.. Three-position detent kit. SDC-F1. Ball friction detent. SDC-S... Spring centering kit. Page D-36

Pressure (psi) 3 25 2 15 1 TS FLOW AND PRESSURE FO: Pressure Drop vs. Flow for P to A or B 3.8 11.3 22.7 34. 45.4 56.7 68. 75.6 Pressure drop is the difference between the inlet pressure and port A or B of any section on a TS1, TS2 or TS3. 21 17 14 1 7 Pressure Drop (psi) 35 3 25 2 15 1 Pressure Drop vs. Flow for A or B to T 3.8 11.3 22.7 34. 45.4 56.7 68. 75.6 Pressure drop is the difference between the port A or B of any section on a TS1, TS2 or TS3 and the outlet. 2.4 2.1 1.7 1.4 1..7 Pressure Drop (bar) 5 3 5.3 Pressure (psi) 45 4 35 3 25 2 15 1 1. 3. 6. 9. 12. 15. 18. 2. 5 Neutral Flow Pressure Drop 3.8 11.3 22.7 34. 45.4 56.7 68. 75.6 This curve represents the pressure difference between the inlet and the outlet.. 1. 3. 6. 9. 12. 15. 18. 2. SPOOL SCHEMATICS: A B 3.1 2.8 2.4 2.1 1.7 1.4 1..7.3 Pressure (psi). 1. 3. 6. 9. 12. 15. 18. 2. 35 3 25 2 15 1 5 Pressure vs. Flow for Area-Differ. Port Relief (B) 3.8 11.3 22.7 34. 45.4 56.7 68. P1279 Spring (White) P127 Spring (Yellow) P127-36 Spring (Orange) DC7594 Spring (Yellow) 1. 3. 6. 9. 12. 15. 18. A B Relief is set at 6 gpm 241 27 172 138 13 69 34 Tandem Center (T) - Powers cylinder or motor in both directions. Pump unloads to tank when spool is in neutral. Cylinder or motor blocked when spool in neutral. Open Center (O) - All of the ports are connected to tank when the spool is in neutral. Allows cylinder to move or motor to rotate when spool is in neutral Closed Center (C)- All ports are blocked in neutral. Blocks cylinder or motor in neutral. Required for use with pressure compensated pump. Tandem Three Way (T3) - Powers the cylinder in one direction. Pump unloads to tank when spool is in neutral, or when spool is being reversed. Cylinder is blocked when spool is in neutral. Port "B" is plugged. Page D-37

DIMENSIONAL DATA: inches & [millimeters] "B" PORT PRESSURIZED.25" [6.3] NEUTRAL POSITION.25" [6.4] "A" PORT PRESSURIZED.25" [6.4] 4 POSITION FLOAT 2.88" [73.1] 1.6" [27.] 1.63" [41.3].72" [18.3].72" [18.2] 7.47" [189.8].26" [6.7].31" [7.9] 4.5" [114.3].94" [23.8] 1.31" [33.3] 1.56" [39.7] 6." [152.4] RELIEF ADJUSTMENT (15 PSI (13 BAR) STD. SETTG) 1.5" [38.2] 7.5" [19.6] 3X Ø.26" [Ø6.7] 2.88" [73.] 5.15" [13.8] 3.59" [91.1] 8.49" [215.7] 1.38" [34.9].19" [4.8] 1.56" [39.7] 1.56" [39.7] 9.66" [245.3] 3.34" [84.9] 3.93" [99.8] 2.81" [71.4] 4.31" [19.5] 5.82" [147.7] TS112TF1JB TS212TF1TSJB TS312TSDTSTKJB Page D-38 9.2" [233.6]