Exhibit Space & Booth Layout Guidelines



Similar documents
Exhibit Space & Booth Layout Guidelines

Exhibit Space & Booth Layout Guidelines

Exhibit Space & Booth Layout Guidelines

Guidelines for Display Rules & Regulations

EXHIBITION DISPLAY RULES

Exhibitor Guidelines for Booth Display Rules and Regulations

Display Rules & Regulations CHFA WEST / CHFA EAST / CHFA QUEBEC

EXHIBIT DISPLAY GUIDELINES

Guidelines for Display Rules & Regulations

Guidelines for Booth Display/ Rules & Regulations

Guidelines for Display Rules & Regulations

EXHIBIT CONSTRUCTION GUIDELINES

10' 16' Maximum. Backwall 5' 5'

booth rules & regulations

EXHIBITION HALL RULES & REGULATIONS

Exhibit Display Rules and Regulations

EXHIBITION HALL RULES & REGULATIONS

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

Dear FDIC International 2015 Exhibitors:

LAMKT SHOW GENERAL INFORMATION

Fire Regulations for Exhibitors

Art Basel Miami Beach Dec Booth Design Regulations

Booth Display Types and Regulations

EXHIBIT/BOOTH SPECIFICATIONS

EXHIBITOR MANUAL. This Exhibitor Manual will provide you with information regarding your exhibit at WESTWARD EXPO'S

120V & 208V ELECTRICAL SERVICE ORDER FORM

BOOTH DESIGN RULES NEW!

JavaOne 2016 Rules & Regulations

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

ATLANTIC CITY CONVENTION CENTER EXHIBITOR KIT

Utility Department City/ Province. State, ZIP, Country

The Fire Safety Manager at (FAX ) can answer any questions or provide a set of fire code information.

January 11-13, 13, 2016 Greater Columbus Convention Center Columbus, Ohio 2016 EXHIBITOR MANUAL THE OHIO NURSERY & LANDSCAPE ASSOCIATION

Fire and Life Safety Requirements for Special Events and Temporary Use of the Facilities at the Kitsap County Fairgrounds.

2015 Exhibit Guidelines

FIRE AND SAFETY REGULATIONS

Exhibitor Manual. Page 1

SAME JETC May 22-25, St. Louis, Missouri IMPORTANT

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Exhibitor Rules & Regulations

ORDERING INFORMATION. How To Order OCCC Services: Mail: Order Online: Ordering

General Fire Code Requirements Within Commercial Tenant Spaces

14a. Hanging Sign Information. It Is The Responsibility Of The Exhibitor To Ensure Your Sign Conforms To All Published Rules And Regulations.

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

SACNAS EXHIBIT BOOTH RESERVATION and AGREEMENT

EXHIBIT DISPLAY INFORMATION

A GUIDE TO EXHIBITING INFORMATION FOR EXHIBITORS INCLUDING DISPLAY INSTRUCTIONS, PRICING, AND MORE WEST COAST ART & FRAME EXPO

IMPORTANT SHOW INFORMATION

43rd Annual International Conference & Exposition

TOY FAIR 2016 STAND BUILD RULES & REGULATIONS

Booth Design Package 2015

2016 SE Regional Fruit and Vegetable Trade Show Sponsored by the: Georgia Fruit & Vegetable Growers Association and Georgia Peach Council

Jacob K. Javits Convention Center

Trade Show Prospectus 3-6 PM, January 29, 2015 Moore Building SC State Fairgrounds

FREEMAN LABOR JURISDICTIONS

ELECTRICAL ORDER KAY BAILEY HUTCHISON CONVENTION CENTER DALLAS

BOOTH CONSTRUCTION. Installation & Dismantle

AAMDC Spring 2016 Trade Show

Booth Space Exhibitor Form

Transcription:

Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines and modified to incorporate some of the needs of the many International exhibitors who are present at PennWell exhibitions. Every attempt has been made to maintain fairness to exhibitors in booths of all sizes and to maintain clear lines of sight to neighboring booths. These rules will be enforced in the exhibit hall and you must have written approval from PennWell to display anything that does not adhere to the limits set forth in this document. Please contact your Exhibit Services Manager if you have any questions regarding these display rules. Booth Height Limit for POWER-GEN / WaterWorld Middle East 2015: 6m Rules & Regulations: Exhibitors with neighbouring booths must ensure that taller stand elements (above 2.5m) are dressed in a plain and neutral colour (white, cream, light grey), carrying no company advertising on any neighbour-facing side. Alternatively, they must be positioned at a minimum of two metres from neighbouring stands. Deviations from this rule may be possible provided that permission has been received from PennWell Corporation in advance. Any taller stand elements not abiding by this regulation will be asked to be removed at the exhibitor s cost. Exhibitors adjacent to another booth must provide their own partitioning wall panels and are not permitted to use the reverse of the neighbour s wall or attach any material to the shell scheme. Raw space stands booked between shell scheme stands must take into consideration the size of the allocated space. Failure to take care over internal measurements could mean that the stand will not fit in the allocated space. All raw space exhibitors must erect rear and dividing walls on any part of the stand that does not face an open aisle. All such walls should be dressed in a plain and neutral colour (white, cream, light grey) and be neatly finished (at show management s discretion) to the rear above 2.5 metres and carry no company advertising. Enclosed walling on open edges of stands must not exceed 50% of the total length. Any run of wall facing onto the aisle or an exhibitors stand must be made of interest for the visitors and on-looking stand. All exposed surfaces and visible areas must be neatly finished. No parts of any structure or exhibit or promotional display (other than those permitted by the Show Management) may extend beyond the boundaries of the site allocated. This includes Electrical fittings, symbols, logos, lighting, floral decorations and furnishings. If any of the above regulations are broken the offense will have to be resolved at the exhibitor s expense. Other Important Considerations Towers A Tower is a freestanding exhibit component separate from the main exhibit fixture. The height restriction is the same as that which applies to the appropriate exhibit configuration being used. Towers in excess of 2.5m must have drawings available for inspection and have Show Management and Venue approval. Fire and safety regulations in many facilities strictly govern the use of towers. A building permit may be required. Multi-story Exhibit A Multi-story Exhibit is a booth where the display fixtures exceed 12 ft (3.66m), including Double-decker and Tripledecker Booths. In many cities, a Multi-storied Exhibit requires prior approval by the exhibit facility and/or relevant local

government agency because it is deemed to be a structure for building purposes. The city building department generally needs to issue a building permit based on an application and drawings prepared and submitted by a licensed architect or engineer. Exhibitors should obtain local building regulations early on to ensure that all time constraints are met. Exhibit Space Lighting and Sound: Without exception, all light and sound must be contained within, and directed into, the footprint of the contracted exhibit space. Additional lighting may be brought in for the exhibit space however this lighting must be restricted to the contracted exhibit space. Lighting should not shine onto the aisles or into a neighbor s exhibit space. Sound must not be at a level that interferes with normal levels of communication in neighboring exhibit space. Vehicles for Indoor Displays: Vehicles to be displayed indoors must adhere to the following guidelines and display will likely be inspected on-site by the local fire marshal. Gas tank must be no more than 1/8 full. Battery must be removed or disconnected. Gas tank must feature a locking cover or cover sealed with tape. Ignition keys removed. Propane or similar compressed gas tanks removed. A fire extinguisher must be present in any booth featuring a display vehicle. Other guidelines may apply depending on the individual Venue Rules and Regulations. Balloons (Static and Controlled): Balloons filled with helium or hydrogen are not permitted (tethered or un-tethered, controlled or stationary) Balloons filled with air may be suspended from the ceiling in exhibits with a minimum size of 400sqft (36sqm), pending Venue approval. In this instance, these will be treated as hanging signs. Please refer to hanging sign rules in this document for additional information. This should be designed so that the balloon is stationary and will not sway in the airflow of open doors or air conditioning. Other guidelines may apply depending on the individual Venue Rules and Regulations. Multi-Story Structures: Multi-story exhibits will require approval from the following: 1) PennWell Show Management to ensure compliance with display rules. 2) The General Service Contractor to ensure that there are no physical obstructions that will create problems during setup. 3) The facility hosting the exhibition. The rules set in place by convention centers and their local fire marshals vary from city to city with regards to the level of fire alarms, sprinklers, extinguishers, etc, that are required in multi-story booths. Stamped engineering drawings will need to be submitted for approval by the fire marshal; PennWell and the General Service Contractor will need a copy of the approved booth on file before booth construction may commence. Please contact PennWell Show Management for additional information and if possible include drawings or renderings of the proposed design. Show Management will determine if the proposed design works with our display rules and will forward the design to the show s General Service Contractor. The Contractor will work with the local fire marshal to give structural approval of the design. PLEASE NOTE: If using a non-official contractor to set-up and/or dismantle your exhibit, the required form to request for set-up by non-official contractor along with the Certificate of Insurance naming the Official General Contractor as an additional insured, must be received by the specified deadline in the Exhibitor Manual. Otherwise labor will have to be hired from the General Contractor by the non-official contractor in order for them to supervise your exhibit. These stipulations are strictly enforced to protect you, show management and the General Contractor. Structural Integrity:

All exhibit displays should be designed and erected in a manner that will withstand normal contact or vibration caused by neighboring exhibitors, hall laborers, or installation/dismantling equipment, such as fork- lifts. Displays should also be able to withstand moderate wind effects that may occur in the exhibit hall when freight doors are open. Exhibitors should ensure that any display fixtures such as tables, racks, or shelves are designed and installed properly to support the product or marketing materials to be displayed Flammable and Toxic Materials: All materials used in display construction or decorating should be made of fire retardant materials and be certified as flame retardant. Exhibitors should be aware of local regulations regarding fire/safety and environment which must be adhered to. Exhibitors should dispose of any waste products they generate during the exhibition in accordance with guidelines established by the facility. Electrical: All 110-volt wiring should be grounded three-wire. Wiring that touches the floor should be SO cord (minimum 14-gauge/three-wire) flat cord, which is insulated to qualify for extra hard usage. Cord wiring above floor level can be SJ which is rated for hard usage. Using zip cords, two-wire cords, latex cords, plastic cord, lamp cord, open clip sockets, and two wire clamp-on fixtures is not recommended and is often prohibited. Cube taps are prohibited. Power strips (multi-plug connectors) should be UL approved, with built-in over-load protectors. Conducting Business outside of Exhibit Space: Distributing literature or promotional items outside of the contracted booth space is prohibited. If additional space is needed, please contact Show Management to purchase additional exhibit hall floor space. Booth Storage: Materials may be stored behind your booth during the show however all materials stored must be masked/covered so they are not visible. A drape or cover may be ordered through the General Services Contractor. Pictures below represent unsightly booth storage& displays that are not allowed. *conducting business outside of exhibit space *unsightly booth storage

*unauthorized storage & exposed backwall *exposed backwalls should be dressed in plain or neutral color Thank you for adhering to these display rules. Please do not hesitate to contact your Exhibit Services Manager if you have any questions regarding your exhibit. If possible, please include a graphic of your booth design with your email to assist us in answering your questions quickly and accurately.

EXAMPLE Booth Violation Dear Exhibitor, your booth has the following violation(s) based on the event name rules and regulations: Height Restriction Line of Site Violation No Carpet Other: Please remove the violation before the start of the show on date. Please visit booth #0000 if you have any questions regarding the violation(s). Thank you for your participation. Event name