EXHIBIT/BOOTH SPECIFICATIONS
|
|
|
- Cornelius McLaughlin
- 9 years ago
- Views:
Transcription
1 BOOTH SPECIFICATIONS Please review the following booth specifications to ensure that your display meets the Exhibit/Booth Guidelines. All booths, regardless of size, are required to follow these guidelines. For questions regarding booth specifications, please contact Show Management at or BOOTH EQUIPMENT Standard 10 x 10 Linear Booths will be set with 8 3 high black back drape and 3 high black side drape. All booths MUST have a professionally finished floor covering. LINEAR (IN-LINE) BOOTHS Definition: Linear Booths have at least one side exposed to an aisle and have at least one adjacent neighbor on either side of the booth. Booths are typically 10 wide and 10 deep. In the back 5 section, display material, signage, equipment and product may not exceed 12 in overall height. Any display material, signage, equipment and product over 8 3 must be professionally finished or draped on the back. Show Management will determine what is considered professionally finished. Exhibitor may be required to order drape to cover unapproved backwall. Signs, banners, logos, images, symbols or flags (including those manufactured on the product or equipment) are not permitted on the backside of the back wall or sidewall at any height. In the front 5 section, equipment, product, display material and signage may not exceed 4 in overall height. Please reference the diagram of allowable configurations. No signs or truss work hung from the ceiling are allowed in linear booths. Note: When three or more Linear Booths are used as a single exhibit space, the 4 height limitation in the front of the booth is applied only to that portion of exhibit space, which is within 10 of an adjoining booth.
2 12 maximum height for display material, signs, back wall and sidewalls, equipment and product; no signage permitted on the back side of the back wall or sidewalls at any height, backside over 8 3 must be professionally finished or draped. 4 maximum height for equipment, product, display material, signs and sidewall 10 X 10 or 10 X 20 BOOTHS 5 feet 5 feet Back wall (plan view) 10 X 30 and LARGER BOOTHS Back wall (plan view) 5 feet 5 feet PERIMETER LINEAR BOOTH Definition: A Perimeter Booth is a Linear Booth that backs to a wall of the facility rather than another exhibit booth. All guidelines for a Linear Booth apply to a Perimeter Booth except that the maximum back wall and sidewall height allowed in the back 5 section is 16 for display material, signage, equipment and product. This includes signs, banners, logos, images, symbols or flags. No signs or truss work hung from the ceiling are allowed in perimeter booths. CANOPIES Exhibitors using canopies or false ceilings over their exhibit may use vertical supports up to 3 inches in width in the corners of their space. Vertical supports that are strictly decorative will not be permitted.
3 PENINSULA BOOTHS Definition: Peninsula Booths are exposed to aisles on three (3) sides and are backed by linear booths. Peninsula Booths are 20 wide by 20 deep or greater. The same principles apply regardless of booth size. Display material, signage (including hanging signs), sidewalls and back wall will be permitted up to a maximum height of 26 when ceiling height permits; except in the 5 section on each side of the back wall which has a 4 maximum height for equipment, product, display material, signs, sidewall and back wall. Unlimited height for equipment and product is permitted throughout the allowable booth space. Please reference the diagram of allowable configurations. No signage (including hanging signs) is permitted on the backside of the back wall at any height. Hanging signs must be placed at least 5 from the back wall. Unlimited height for equipment and product; 26-ft. maximum height for display material, signs, back wall and sidewall (when ceiling height permits); no signage (including hanging signs) permitted on the backside of the back wall at any height; hanging signs must be at least 5 from the back wall 5 Min. Back wall (plan view) 5 Min. 4-ft. maximum height for equipment, product, display material, signs, back wall and sidewall SPLIT ISLAND BOOTHS Definition: A Split Island Booth is an Island Booth that shares a common side with another Island Booth. Split Island booths are 20 wide by 20 deep or greater. Display material, signage (including hanging signs) and back wall will be permitted up to a maximum height of 26 when ceiling height permits. Unlimited height for equipment and product is permitted throughout the booth. No signage (including hanging signs) is permitted on the backside of the back wall at any height. Hanging signs must be placed at least 5 from the back wall.
4 ISLAND BOOTHS Definition: An Island Booth is any 20 wide by 20 deep or greater booth exposed to aisles on all four sides of the booth. Display material and signage (including hanging signs) will be permitted up to a maximum height of 26 when ceiling height permits. Unlimited height for equipment and product is permitted throughout the booth.
5 HANGING SIGNS Hanging signs are defined as banners, logos, images, symbols and flags. Hanging signs and truss work hung from the ceiling are not permitted in linear and perimeter booths. Hanging signs will be permitted in the following booth configurations to a maximum height (dependent on ceiling height in exhibit hall)of: Peninsula Booth: 26 maximum from floor to top of sign Split Island Booth: 26 maximum from floor to top of sign Island Booth: 26 maximum from floor to top of sign - ALL hanging signs must be a minimum of 9 off the floor (from the floor to the bottom of the sign). Signs may be hung from the ceiling (where permitted), truss work or equipment. Signs that will be hung from the ceiling or truss work must be installed and dismantled by Freeman. HANGING SIGNS FROM EQUIPMENT Hanging signs from equipment must conform to the height limitations above. Freeman must approve rigging of signs that weigh over 250 pounds and are hung by the exhibitor or Exhibitor Appointed Contractor. For questions on hanging signs, please call Show Management at LIGHTING Lighting (including lasers) must be contained within the confines of the booth and must not wash into aisles or other booths. Strobe lights that are not sold as product by the exhibiting company are prohibited. Note: Las Vegas Convention Center has specific rules on the use of halogen lights. Please reference the Exhibitor Service Manual for full details. SOUND/MUSIC Sound of any kind may not be projected outside the confines of the booth. Show Management reserves the right to determine if sound constitutes interference and must be discontinued. DEMONSTRATIONS When conducting demonstrations or presentations, all activity and viewers must be contained within the booth and all aisles must remain clear. To prevent gatherings in
6 an aisle, demonstrations cannot be conducted on any edge of the booth along an aisle. MULTI-LEVEL, COVERED AND SELECT SINGLE LEVEL EXHIBITS LVCC requires exhibitors with a single-level exhibit exceeding A) 300 square feet of covered area or B) 1,000 total square feet AND ALL EXHIBITORS with multi-level exhibits to submit plans to the Las Vegas Convention Center Fire/Safety department for approval prior to onsite arrival. See the Rules and Regulations of the Exhibitor Service Manual for details.
EXHIBIT CONSTRUCTION GUIDELINES
EXHIBIT CONSTRUCTION GUIDELINES STANDARD BOOTH DEFINITIoN: Exhibit consisting of one or more standard units in a straight line. be permitted to a maximum height of 8 3 (2.5m). INTENT If a portion of an
10' 16' Maximum. Backwall 5' 5'
Peninsula December 11 13, * ALL PENINSULA EXHIBITORS ARE REQUIRED TO SUBMIT ACCURATE RENDERINGS AND DIMENSIONS OF THE PENINSULA EXHIBIT TO TRADE SHOW MANAGEMENT FOR APPROVAL PRIOR TO THE SHOW. (For questions,
Guidelines for Display Rules & Regulations
The following Guidelines for Display Rules and Regulations have been established in accordance with guidelines set forth by All Baby & Child (ABC), based on those established by the International Association
EXHIBIT DISPLAY GUIDELINES
EXHIBIT DISPLAY GUIDELINES The following Guidelines for Display Rules and Regulations have been established by the International Association of Exhibitions and Events (IAEE). Guidelines for Display Rules
Display Rules & Regulations CHFA WEST / CHFA EAST / CHFA QUEBEC
CHFA WEST / CHFA EAST / CHFA QUEBEC Display rules and regulations ensure that all exhibitors, regardless of exhibit size or location, enjoy an environment that is conducive to successful interaction with
EXHIBITION DISPLAY RULES
RULES AND REGULATIONS Responsibility of the exhibiting company to comply with SPIE rules and regulations. Non-compliance may require modifications at the exhibitor s expense SPIE Exhibition Management
BOOTH DESIGN RULES NEW! [email protected]
BOOTH DESIGN RULES All exhibits must conform to the dimensions outlined below in order to assure ease of movement of participants and clear lines of visibility in the exhibit hall. For more information
Exhibit Display Rules and Regulations
Exhibit Display Rules and Regulations 16' 6'' Finished wall no copy 8' 3" (2.5m) must be 10' (3.05m) 4' 1.5" (1.25m) 50% of total width centered Standard Booth One or more standard units in a straight
booth rules & regulations
booth rules & regulations CAMEX Trade Show: March 6-8, 2016 George R. Brown Convention Center 1001 Avenida de las Americas Houston, TX 77010 www.houstonconventionctr.com Questions? Mary Adler-Kozak, Director
BOOTH CONSTRUCTION. Installation & Dismantle
Installation & Dismantle Exhibit Installation Installation days and hours are as follows: Wednesday, November 11 and Thursday, November 12 7:30 AM 7:00 PM Friday, November 13 7:30 AM 10:00 PM Every individual
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
Booth Display Types and Regulations
Booth Display Types and Regulations Booth Construction: Ultra-Premium, Premium and Standard Booths are 10 x 10 and will be set with 8 high white hardwall back panels, 3 high white hardwall side dividers.
Guidelines for Display Rules & Regulations
BOOTH OPTIONS The following display rules and regulations will be strictly enforced by NAMM and its representatives on the show floor. They were developed by the Exhibit Designers and Producers Association
Exhibiting As (this is how your company name will appear in all trade show materials) City State Postal Code Country
Railway Interchange 2015 Indoor Exhibit Space - Application & Contract October 4 6, 2015 Minneapolis Convention Center 1301 2nd Avenue South, Minneapolis, MN USA A. Application COMPANY INFORMATION Company
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
Exhibitor Guidelines for Booth Display Rules and Regulations
Exhibitor Guidelines for Booth Display Rules and Regulations NACE strives to provide each exhibitor with a reasonable sight line from the aisle. To help accomplish this, the following Guidelines for Booth
Guidelines for Display Rules & Regulations
Guidelines for Display Rules & Regulations You are reminded that a booth design, including flooring and fixtures, is REQUIRED in order for your company to maintain consideration for future shows. Booth
Guidelines for Booth Display/ Rules & Regulations
Guidelines for Booth Display/ Rules & Regulations The Car Wash Show requires that Exhibitors with island or peninsula booths 400 square feet and above must submit a floor plan with dimensions, including
14a. Hanging Sign Information. It Is The Responsibility Of The Exhibitor To Ensure Your Sign Conforms To All Published Rules And Regulations.
It Is The Responsibility Of The Exhibitor To Ensure Your Sign Conforms To All Published Rules And Regulations. 14a 1 Important Defined as any materials, including but not limited to, signs and machinery,
EXHIBITION HALL RULES & REGULATIONS
EXHIBITION HALL RULES & REGULATIONS The Exhibition Hall is exclusively for the education of persons attending the meeting, and Exhibitors are expected to conduct themselves accordingly. 1. Booth Carpeting.
2016 SE Regional Fruit and Vegetable Trade Show Sponsored by the: Georgia Fruit & Vegetable Growers Association and Georgia Peach Council
2016 SE Regional Fruit and Vegetable Trade Show Sponsored by the: Georgia Fruit & Vegetable Growers Association and Georgia Peach Council Exhibit General Terms and Conditions 1. LOCATION - The Trade Show
2015 Exhibit Guidelines
2015 Exhibit 1 2015 Exhibit 8 Press Room The 2015 Exhibit Policies and apply to all exhibitors: both industry and non-industry entities. Industry includes for-profit entities that develop, produce, market,
Booth Design Package 2015
Art Toronto 23-26 Oct 2015 arttoronto.ca Booth Design Package 2015 Opening preview October 22, 2015 Metro Toronto Convention Centre Page 1 of 11 How to submit your Booth Design... Page 2 Sample Booth Design
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
JavaOne 2016 Rules & Regulations
JavaOne 2016 Rules & Regulations The Rules and Regulations governing JavaOne 2016 are an integral part of the contract for exhibit space and have been established to protect all parties involved. Exhibits
REALTOR QUEST 2016 EXHIBITOR RULES AND REGULATIONS
REALTOR QUEST 2016 EXHIBITOR RULES AND REGULATIONS 1 GENERAL EXHIBITOR RULES AND REGULATIONS The following General Exhibitor Rules and Regulations are for REALTOR QUEST 2016 presented by the Toronto Real
EXHIBITION HALL RULES & REGULATIONS
EXHIBITION HALL RULES & REGULATIONS The Exhibition Hall is exclusively for the education of persons attending the meeting, and Exhibitors are expected to conduct themselves accordingly. 1. Booth Carpeting.
SHOW RULES & REGULATIONS
SHOW RULES & REGULATIONS All exhibitors displaying at IFPE 2017 to be held in Las Vegas, Nevada, at the Las Vegas Convention Center from March 7 11, 2017, are required to complete an application, execute
IMPORTANT SHOW INFORMATION
AGE LIMIT IN EXHIBIT HALL No one under 21 years of age is allowed into the Nightclub & Bar Convention and Trade Show either as an attendee or as booth personnel. For reasons of safety and the professional
43rd Annual International Conference & Exposition
43rdAnnualInternational Conference&Exposition NATIONALORGANIZATIONOFMINORITYARCHITECTS EXHIBITORINFORMATION LegacyNOMA CommunityServiceDay Wednesday,October14,2015 InternationalConference Thursday,October15,2015
A. General Exhibitors participating in the AAN Annual Meeting exhibition must understand the following:
2016 AAN ANNUAL MEETING EXHIBIT CONTRACT TERMS & CONDITIONS 1. ELIGIBILITY: Eligibility to exhibit at the 2016 Annual Meeting is determined solely by the AANI and generally restricted to companies directly
Exhibitor Rules & Regulations
Eligibility for Exhibiting: The following Rules and Regulations are intended to produce an Exposition that treats all exhibitors equally and fairly; presenting an equal opportunity for all exhibitors to
Dear Solar Canada 2015 Exhibitor,
Dear Solar Canada 2015 Exhibitor, Thank you for choosing to exhibit at the Solar Canada 2015 Conference and Exposition in Toronto. This Exhibitor Reference Manual covers the essentials of exhibiting at
NTI Exposition Rules and Regulations
NTI Exposition Rules and Regulations Show Management Exposition management is provided by the American Association of Critical-Care Nurses (AACN). It is AACN s intent that a professional atmosphere for
GLAUCOMA FOR THE CATARACT SURGEON EXHIBITOR PROSPECTUS NEW ORLEANS FRIDAY, MAY 6
2016 GLAUCOMA FOR THE CATARACT SURGEON EXHIBITOR PROSPECTUS NEW ORLEANS FRIDAY, MAY 6 CorneaDay.org ASCRSGlaucomaDay.org 2016 INVITATION TO EXHIBIT Dear Exhibitor: We are pleased to invite you to exhibit
ATLANTIC CITY CONVENTION CENTER EXHIBITOR KIT
ATLANTIC CITY CONVENTION CENTER EXHIBITOR KIT ONE CONVENTION BOULEVARD P H O N E ( 6 0 9 ) 4 49-2 2 9 1 FA X ( 6 0 9 ) 4 49-24 6 4 F E D I D # 2 2 2 63 8 5 63 SERVICE ORDER(S) PAYMENT FORM Payment Required
FREEMAN LABOR JURISDICTIONS
UNION JURISDICTIONS for TAMPA, florida To assist you in planning for your participation in this upcoming exposition, we are certain you will appreciate knowing in advance that union labor may be required
January 11-13, 13, 2016 Greater Columbus Convention Center Columbus, Ohio 2016 EXHIBITOR MANUAL THE OHIO NURSERY & LANDSCAPE ASSOCIATION
January 11-13, 13, 2016 Greater Columbus Convention Center Columbus, Ohio 2016 EXHIBITOR MANUAL THE OHIO NURSERY & LANDSCAPE ASSOCIATION GENERAL INFORMATION ATTENTION! ATTENTION! The Convention Center
Exhibitor Rules & Regulations
SELLING YOUR EXHIBIT BOOTH MATERIAL New this year: Due to the renovation, dock space is very limited this year. Exhibitors are prohibited from selling one s exhibit booth or plants. Cultivate has secured
FREEMAN ELECTRICAL SERVICES FAQ s
FREEMAN ELECTRICAL SERVICES FAQ s From under carpet wiring to overhead lighting, Freeman has the power to simplify your electrical needs and installation. We ve answered your most common questions below
Exhibit Space & Booth Layout Guidelines
Exhibit Space & Booth Layout Guidelines Exhibit Space & Booth Display Rules The following display rules have been designed using the IAEE (International Association of Exhibitions and Events) guidelines
SXSW 2016 EXHIBITOR HANDBOOK TRADE SHOW A COMPLETE GUIDE TO EXHIBITING AT SXSW IN THE AUSTIN CONVENTION CENTER
SXSW 2016 EXHIBITOR HANDBOOK TRADE SHOW A COMPLETE GUIDE TO EXHIBITING AT SXSW IN THE AUSTIN CONVENTION CENTER CONTENTS Key Facts - - - - - - - - - - - - - - - - - - - - 03 Booth Types & Diagrams - - -
Thursday, April 28, 2016 Emergency Management Symposium Radisson Hotel, Cromwell, CT APPLICATION AND CONTRACT FOR MAJOR SUPPORT
FOR CCM USE ONLY Firm Name: Date Booth Thursday, April 28, 2016 Emergency Management Symposium Radisson Hotel, Cromwell, CT APPLICATION AND CONTRACT FOR MAJOR SUPPORT By completing this application for
Trade Show Prospectus 3-6 PM, January 29, 2015 Moore Building SC State Fairgrounds
Trade Show Prospectus 3-6 PM, January 29, 2015 Moore Building SC State Fairgrounds Show Date, Time, Place, Show Colors Thursday, January 29, 2015 3:00-6:00 p.m. - Exhibit Hours Moore Building, South Carolina
RULES & REGULATIONS. The Industry s Gold Standard. packexpo.com
RULES & REGULATIONS The Industry s Gold Standard packexpo.com Exhibitors understand and agree that the PACK EXPO Las Vegas/Pharma EXPO 2015 Rules and Regulations are an integral and binding part of the
CAREER FAIR EXHIBITOR INFORMATION PACKET
CAREER FAIR EXHIBITOR INFORMATION PACKET 2016 Cancer and Biomedical Research Career Fair The 2016 Cancer and Biomedical Research Career Fair, is coming to New Orleans, Louisiana on Saturday, April 16,
EXHIBITOR SERVICE MANUAL
EXHIBITOR SERVICE MANUAL ADA AMERICANS WITH DISABILITIES ACT All exhibiting companies are required to be in compliance with the Americans with Disabilities Act (ADA), and are encouraged to be sensitive,
NACDS 2016 Total Store Expo Rules and Regulations
Section I: All Attendees NACDS 2016 Total Store Expo Rules and Regulations 1. Agreement to Conditions Each Attendee, and each Exhibitor for himself and his employees, agrees to abide by these conditions,
ORDERING INFORMATION. How To Order OCCC Services: Mail: Order Online: www.occc.net/exhibitor. Ordering Email: Exhibitor.Services@occc.
ORDERING INFORMATION Show Name: TecHomeX Incentive Deadline Date: February 29th, 2016 OCCC Exhibitor Services Coordinator: DeCory Kelso Direct Phone: (407) 685-5166 Contact Email: [email protected]
OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.
1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310
Dear Exhibitors, We appreciate your order! Sincerely, Edlen Electrical Exhibition Services ELECTRICAL ORDER FORM
ELECTRICAL ORDER FORM Phone: (213) 765-4676 Fax: (213) 765-4679 EVENT: Virtual Reality LA FACILITY: Los Angeles Convention Center DATES: August 29, 2015 EVENT #: 085097LA Dear Exhibitors, Please note that
SAME JETC May 22-25, 2012. St. Louis, Missouri IMPORTANT
18a Electrical Terms and Conditions IMPORTANT Please read the list of work below. If you require any of this work to be performed in your booth space, it must be performed by a show electrician. This work
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the
TEXAS SELF STORAGE ASSOCIATION EXHIBITOR PROSPECTUS 2014 ANNUAL CONFERENCE FORT WORTH CONVENTION CENTER
TEXAS SELF STORAGE ASSOCIATION EXHIBITOR PROSPECTUS 2014 ANNUAL CONFERENCE FORT WORTH CONVENTION CENTER October 26 28, 2014 TEXAS SELF STORAGE ASSOCIATION SEE YOU IN FORT WORTH! TSSA EXHIBITOR PROSPECTUS
Dear FDIC International 2015 Exhibitors:
Dear FDIC International 2015 Exhibitors: Before you know it, FDIC 2015 will be upon us! On behalf of the PennWell Fire Group, we want to ensure another successful event for you and your business. As the
