Voyager 1202g BF. Quick Start Guide. Cordless Single-Line Laser Bar Code Scanner and CCB00-010BT-01N-BF base



Similar documents
Voyager 1202g. Quick Start Guide. Cordless Single-Line Laser Bar Code Scanner

Voyager 9520/40 Voyager GS9590 Eclipse 5145

Xenon Corded Area-Imaging Scanner. Quick Start Guide

3800 Linear Series. Quick Start Guide

Dolphin 6500 Mobile Computer. with Windows CE 5.0. Quick Start Guide

METROLOGIC INSTRUMENTS, INC. IS4225 ScanGlove USB Addendum for the MetroSelect Single-Line Configuration Guide

Dolphin 70e Black. Quick Start Guide. with Windows Embedded Handheld E-WEH-QS Rev B 6/13

Dolphin TM 6100 Mobile Computer. Quick Start Guide

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide WIRELESS SCANNER

Thor VM1. Quick Start Guide. Vehicle-Mount Computer. with Microsoft Windows Embedded CE 6 or Windows Embedded Standard 2009 Operating System

MX7 Tecton. Quick Start Guide. Hand-Held Computer. With Microsoft Windows Embedded CE 6 or Windows Mobile 6.5 Operating System. TECTON-QS Rev A 4/12

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

Scanner Wedge for Windows Software User Guide

Dolphin 9900 Mobile Computers

Laser Barcode Scanner

Laser Barcode Scanner User s Manual

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

DUET / VS800 Scanner. DUET Scanner VS800 Scanner. Programming Kit

Keep it Simple Timing

LS6300 Lecteur de code-barres laser

Dolphin Power Tools 8.x

QuickSpecs. HP Wireless Keyboard and Mouse. Models

METROLOGIC INSTRUMENTS, INC. MS1690 Focus Area Imaging Bar Code Scanner Supplemental Configuration Guide

QuickScan i. QD2100 Barcode Imager. Product Reference Guide

Programming Reference Guide HP USB Barcode Scanner

Configuration Guide HP Point of Sale (POS) Accessories. Document Version 1.00

USER'S GUIDE NUSCAN 2100 Series

Metrologic MS1690 2D Scanner Installation Guide

METROLOGIC INSTRUMENTS, INC. MetroSelect Configuration Guide

MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners

HP Point of Sale (POS) Peripherals Configuration Guide 2D Imaging / Linear / Presentation Scanner

Baracoda RoadRunners. User Guide. This document is to be used with the Baracoda RoadRunners. Baracoda RoadRunners

MultiOne. Getting started

METROLOGIC INSTRUMENTS, INC. USB Addendum for the IS4220 Programming Guide (MLPN x)

Release Notes: PowerChute plus for Windows 95 and Windows 98

QuickScan L. Barcode Scanner. Advanced Data Formatting (ADF) Guide

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

MetroSelect. Single-Line Scanner. Configuration Guide

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

HANDHELD LASER SCANNER

Welcome to the Pocki-MP3 User Guide. Function Indicator Symbols

Universal Vehicle Power Supply 9007AX01. Installation Instructions

QUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS)

it500 Internet Thermostat INSTALLER MANUAL

APPENDIX E COMMAND BARCODES

Quantum View Manage Administration Guide

Rapier V1. Laser Gaming Mouse. User Guide English

METROLOGIC INSTRUMENTS INC. MetroSelect Single-Line Configuration Guide

SG20T. Tethered Scanner. User s Guide

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

MetroSelect Programming Guide. MLPN 2407/December 1998

UM0109 USER MANUAL. Public Transport Ticketing Demo

NortechCommander Software Operating Manual MAN R6

HP USB Smartcard CCID Keyboard. User Guide

New MINIMAG Magnetic Stripe Reader

Package Checklist. Overview. Features. USB Data Link Cable User s Manual. USB Data Link Cable User s Manual 1

hp digital home networking wireless USB network adapter hn210w quick start guide

Plug-in Installation Instruction Xenon 1900/1902 Scanner

2. The scanner examines the scanned data to determine if the barcode represents an XL Type I command or not. In Pseudo-Code:

Image Lab Software for the GS-900 Densitometer

Temperature & Humidity SMS Alert Controller

Batch and Import Guide

FEC Secure IPSec Client

Barcode Scanner User Manual V6.6.2

AT89C5131A Starter Kit... Software User Guide

AN974 APPLICATION NOTE

ASUS GX900 Gaming Mouse

Agilent Automated Card Extraction Dried Blood Spot LC/MS System

HP ilo mobile app for Android

Barcode Labels Feature Focus Series. POSitive For Windows

Broadcasting Audio Messages with Group Paging and Push-to-Talk

Connecting a Metrologic MS9535 to a USB BT Adapter (Client Mode)

Scanner Configuration

Centran Version 4 Getting Started Guide KABA MAS. Table Of Contents

Application Notes for VTech 1-Line and 2-Line Analog Hotel Phones with Avaya IP Office 8.1 and Voic Pro 8.1 Issue 1.0

A free call from your Roadpost satellite phone: A free call from North America:

Synapse Smart Cable for NEC PC 9821 Interface Guide

Table of Contents. GETTING STARTED...1 Technical Support...1 Scanner Configuration...2 Login and Select a Mode...4

AN3354 Application note

E-i. Section E. Code Formatting. E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

UM0985 User manual. Developing your STM32VLDISCOVERY application using the IAR Embedded Workbench software. Introduction

SPC5-FLASHER. Flash management tool for SPC56xx family. Description. Features

Getting Started. rp5800, rp5700 and rp3000 Models

PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual

Locked Web Browser. User s Manual

CS3000 SERIES SCANNER PRODUCT REFERENCE GUIDE

ACT! by Sage. Premium for Workgroups 2007 (9.0) Administrator s Guide to the ACT! Reader Utility

HS-251xW-TS Series Laser Barcode Scanner User s Manual

Scan2CRM for ACT! User Guide

RESCUE CD. User s Guide

Client Instructions - ID Tech Configuration Instructions

FLoader User's Manual

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility 19 April 2011

PowerMic II Getting Started Guide. Dragon Medical Practice Edition

PowerScan D Imager

1. INTRODUCTION TO SUUNTO SMART BELT 2. GETTING STARTED WITH SUUNTO SMART BELT

Advanced Software Upgrade Guide

Transcription:

Voyager 1202g BF Cordless Single-Line Laser Bar Code Scanner and CCB00-010BT-01N-BF base Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a www.honeywellaidc.com para español. Para Português, acesse www.honeywellaidc.com.br. Перейти на русскоязычный сайт www.honeywellaidc.com. Pro češtinu jdi na www.honeywellaidc.com. Pre slovenčinu choď na www.honeywellaidc.com. 日 本 語 : www.honeywellaidc.com をご 覧 ください 如 要 到 中 国 www.honeywellaidc.com( 简 体 ) 한글 www.honeywellaidc.com 로 이동합니다. VG1202BF-QS Rev B 2/15

Note: Refer to your user s guide for information about cleaning your device. Getting Started Turn off the computer s power before connecting the base, then power up the computer once the base is fully connected. When the base is connected and powered up, put the scanner in the base to establish a link. The green LED on the base flashes to indicate the scanner s instant charge pack is charging. The scanner must be returned to the base when not in use. A scanner charged on the base with the power supply for 35 seconds will result in 100 scans, with one scan every second. Power Supply Assembly (if included)

USB Connection Note: Charging the scanner through a USB port takes more time than direct AC adapter charging.

RS232 Serial Port Connection

RS485 Connection

Keyboard Wedge Connection Note: For Keyboard Wedge, you must use the power supply.

Base LED Sequences and Meaning Scanner Base LEDs Charge Base Red LED - Host Communication Red LED Off On continuously Short blinks. Occurs while transferring data to the host port. Condition Power off, USB suspend Power on, system idle Receiving data Green LED - Scanner Battery Green LED Off Slow flash, 1 second on, 1 second off Slow flash, 0.5 second on, 0.5 second off Slow flash, 0.25 second on, 0.25 second off On continuously Condition Instant charge pack not detected or charge suspended Charging, Instant charge pack near empty Charging, Instant charge pack at medium capacity Charging, Instant charge pack near full capacity Charge complete

Reading Techniques Standard Product Defaults The following bar code resets all standard product default settings. RS485 Interface Standard Product Defaults The RS485 interface defaults to port 5B. If you have an IBM POS terminal using port 9B, scan the appropriate code below to program the terminal, then power cycle the cash register. IBM Port 9B HHBCR-1 Interface IBM Port 9B HHBCR-2 Interface Note: For additional RS485 interface selections, see the User s Guide for your product at our website, www.honeywellaidc.com.

Keyboard Country If your interface is USB Keyboard or Keyboard Wedge, your keyboard layout default is a US keyboard. To change this layout, refer to the chart below for your keyboard country. Scan the Program Keyboard Country bar code below, then scan the numeric bar code(s) for the appropriate Country Code from page 2, then scan the Save bar code. By default, national character replacements are used for the following characters: #$@[\]^ { }~ Refer to the ISO 646 Character Replacements chart in your User s Guide to view the character replacements for each country. Program Keyboard Country Country Code Scan Country Code Arabia 91 IBM Financial 90 Scan Country Code Sweden/ Finland Belgium 1 Italy 5 Switzerland 6 China 92 Japan 28 Thai 94 France 3 Korea 93 Turkey (Q) 24 Germany/ Austria 4 Portugal 13 USA (Default) 0 Great Britain 7 Russia 26 Vietnam 95 Hungary 19 Spain 10 Scan 2 Save

Locked Link If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base. If you do place a different scanner into the base, it will charge the scanner, but the scanner will not be linked. To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code, below. Override Locked Scanner Locked Link Mode (Single Scanner) If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner bar code with a new scanner, and place that scanner in the base. The locked link will be overridden; the broken or lost scanner s link with the base will be removed, and the new scanner will be linked. Unlinking the Scanner Override Locked Scanner If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous scanner is unlinked, it will no longer communicate with the base. Scan the Unlink Scanner bar code to unlink a scanner. Unlink Scanner

Out-of-Stand Modes/CodeGate Activation When the scanner is in the stand, bar codes are automatically read when they are in the scanner s field of view. When the scanner is out of the stand, by default you must push the button on top of the scanner to read a bar code. Use the following commands to adjust how the scanner behaves when it is out of the stand. Note: If you are using a cordless charge base in Presentation Mode, the power pack will not charge unless the power supply is plugged into the base s auxiliary power port. Presentation Mode Out-of-Stand: When the scanner is not in the stand, it automatically detects bar codes, then scans and transmits the data. The laser turns off afterward. Presentation Mode with CodeGate Out-of-Stand: When the scanner is not in the stand, it automatically detects bar codes and decodes them. However, the data is not transmitted until you press the button. The laser remains on briefly after the transmission. Presentation Mode Out-of-Stand Presentation Mode with CodeGate Out-of-Stand

Suffix If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes. Add CR Suffix Add Tab Suffix Remove Suffix Add Code ID Prefix to all Symbologies Scan the following bar code if you wish to add a Code ID prefix to all symbologies at once. Add Code ID Prefix To All Symbologies Note: For a complete list of Code IDs, see the User s Guide for your product at our website, www.honeywellaidc.com.

Data Format Editor Instructions The following are abbreviated instructions for entering a data format. For complete instructions refer to your User s Guide, available at our website, www.honeywellaidc.com. 1. Scan the Enter Data Format symbol. 2. Primary/Alternate Format: scan 0 for Primary Format 3. Terminal Type: scan 099 for any terminal type 4. Code I.D.: scan 99 for any bar code type 5. Length: scan 9999 for any length bar code. 6. Editor commands: use the Programming Chart that follows. 7. Scan Save to save your entries. Enter Data Format Clear All Data Formats Save

Programming Chart 0 1 2 3 4 5 6 7

8 9 A B C D E F Save

EZConfig-Scanning To access additional features for the scanner use EZConfig- Scanning, an online configuration software tool, available from our website at www.honeywellaidc.com. Technical Assistance Contact information for technical support, product service, and repair can be found at www.honeywellaidc.com. Limited Warranty Refer to www.honeywellaidc.com/warranty_information for your product s warranty information. User Documentation For localized versions of this document, and to download the User s Guide, go to www.honeywellaidc.com. Patents For patent information, go to www.hsmpats.com. Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII. HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII. 2015 Honeywell International Inc. All rights reserved.

Web Address: www.honeywellaidc.com