Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy



Similar documents
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

MNS is Switchgear System Technical Overview

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

The Intelligent AX1 Switchgear for Medium Voltage

Low Voltage Switchboards The Best Technical Solution for Your Ship

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Unified requirements for systems with voltages above 1 kv up to 15 kv

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

FAQs-Main switchboard design criteria

TriLine ASSEMBLY System PowerModules

SIVACON The Versatile Low-Voltage Switchboard

Quick Connect. quick - simple - efficient.

Disconnectors and Earthing Switches 36 kv up to 800 kv

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Medium voltage products. UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications

UFES Active protection for switchgear

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Distribution Boards & Consumer Units

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

HMS Air-Insulated Medium-Voltage Metal-Clad Switchgear. Internal Arc Proof

SIVACON Low Voltage Switchboard

The power distribution board that sets new standards

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

5SV Residual Current Protective Devices

Securing your electrical installations Prisma,

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

Electronic overload relay EF19 and EF45

Automation Products. Low Voltage Switchgear MNS System Overview

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

CAS 36 Ring Main Unit

Technical catalogue TK 503/01 E. ZX0.2 Gas-insulated medium voltage switchgear

Electronic overload relay EF65, EF96 and EF146

The following components are common to most cubicles; this example is an ABB HK cubicle.

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

Medium Voltage Switchgear

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Secondary Unit Substations

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

R.C.C.B. s two-pole LEXIC

Nothing s BetterThan the Original MODAN Power Distribution Systems

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Transformer Bushings for GIS

Engineering Specification

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Switchboard system. NorLine 800

3K Load-Break Switches The Program for Safety and Performance. sentric

Advantages of Fixed Circuit Breaker Switchgear

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Multi-cubicle type switchboard systems. NorPower 5000

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Relay mounting systems

HERZ-Thermal Actuators

How To Make A Power Supply From A Power Generator

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

E-STOP relays, safety gate monitors

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Fusible Disconnect Switch

GE Power Controls. MiniFORM Switchboards

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

MNS Low Voltage Switchgear System Guide

Safe and secure distribution of medium voltage with AX1

Contact expansion modules

ZS1 Air-insulated medium voltage switchgear, 12 kv/17.5 kv Instruction manual BA 372/04 E

Thyristor-controlled power supplies and battery chargers

Power products and systems. Intelligent solutions for power distribution Zone concept

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

SENTRON Switching and Protection Devices Air Circuit Breakers

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Choosing for tranquility

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

The Low-Voltage Switchboard that Sets New Standards

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

8146/5 Series Breaker Panelboards

Transcription:

Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility and cost-efficiency. Type-tested components, compatible products and standardized interfaces are the special features of our ENERGOLINE family. The ENERGOLINE brand is emblematic of power, dynamics and strength properties that our products demonstrate on a daily basis in countless applications. 8PU Premium Premium quality for all low voltage applications MV Energy The energizer of medium voltage up to 17,5kV ENERGOLINE is more than just quality products made in Germany. ENERGOLINE is, first and foremost, our employees, and their dedication, creativity and passion. POWER DYNAMIC PASSION COMMITMENT CREATIVITY 2

Introducing our products Safely reliable The INDUSTRIAL SWITCHGEAR SYSTEM provides a well-engineered standard product with a type-tested, factory-assembled, air-insulated medium voltage switchgear that can be flexibly used in the networks of public utility companies, public-sector energy companies and industrial companies. It can be used universally as a ring cable switchgear system as well as for complex power distribution. The MV Energy medium voltage switchgear can be employed wherever medium voltage power has to be distributed safely and economically. It is able to carry out every switching, separation, distribution and control function required of a switchgear system. Proven design principles, the latest in innovation, flexible modular solutions and continuous type and arc fault testing guarantee appropriate use and the highest degree of reliability and cost-effectiveness. With its wide spectrum of slide-in and fixed-mounted options, the system can be used for all types of applications in the areas of energy supply, energy distribution, power stations, process industries and infrastructure. Series:» R12 up to 12 kv 3.150 A 40 ka» R17,5 up to 17,5 kv 3.150 A 40 ka Our portfolio includes various designs that can easily be combined with one another:» Vacuum circuit breakers using fixed-mounted and slide-in technology» Vacuum contactor using fixed-mounted and slide-in technology» Switch disconnectors using fixed-mounted technology» Measuring fields Today, resistance to arc faults is an important and, in many applications, an imperative requirement of modern INDUSTRIAL SWITCHGEAR SYSTEM. Your advantages at a glance:» Air-insulated medium voltage switchgear, metal-clad, indoor installation» More economical and higher fl exibility thanks to the modular system» Type-tested in accordance with all major international standards» Various design options that can be fl exibly combined» Single or dual busbar system» The highest degree in personal and system protection through arc fault testing, IAC AFRL 40 ka, 1s» Partition class PM: metal partitioning between all devices, busbar and cable compartments» High-quality measuring, control and protection systems ensure reliable operation that can be designed to meet technical and customer requirements» Use of communication-specifi c components» Can be optionally equipped with a certifi ed pressure» Routine factory testing in accordance with VDE/EN/IEC standards and specifi c customer requirements All of our switch cabinets are certified in accordance with IEC 62271-200 and fulfil, without exception, the criteria required by arc fault testing. The medium voltage switchgear MV Energy is IAC qualified which serves as proof that it is safe for both personnel and the equipment itself. The switch cabinets are furnished with all of the equipment, locking mechanisms and accessories necessary to ensure a high level of personal and system safety and reliability. 3

Reliability produces satisfaction Equipment and switchgear accessories The medium voltage switchgear MV Energy can be fitted with a large range of devices for switching, controlling, measuring and protecting. Slide-in vacuum circuit breakers The circuit breakers are mounted on the slide-ins and can be withdrawn. The procedure can be carried out with a closed door. Control and signal leads are connected to a low voltage compartment by a plug.» Switching units preferably from ABB, Siemens and TAVRIDA Other manufacturers available upon request. Slide-in vacuum contactors The vacuum contactor is mounted on the slide-in and can be withdrawn. The procedure can be carried out with a closed door. Control and signal leads are connected to the low voltage compartment by a plug.» Switching units preferably from ABB and Siemens Switch disconnectors The permanently installed switch disconnector is designed for switching and protecting the ring line or transformers (in connection with HV fuse links for short circuit protection) or for current-free switching. Each unit can be designed with an earthing switch with a making capacity for grounding wires.» Switching units preferably from ABB and TAVRIDA Current transformers Cast resin contactor transformers are used for feeding the measuring and protection devices. Their thin design enables switch cabinets up to B = 650 mm.» Preferably from ABB, ELEQ, Ritz or according to customer requirements Voltage converters The single-pole voltage converters are permanently installed or can be mounted on a slide-in trolley. Their thin design enables switch cabinets up to B = 650 mm.» Preferably from ABB, ELEQ, Ritz or in accordance to customer requirements Earthing switches Every incoming feeder cubicle and outgoing feeder panel can be delivered with a quick earth electrode for grounding wires and busbars that is protected against switch-on. These can be operated using a manually operated or motor driven bevel-gear that is either mechanically or electronically locked» to the circuit breaker slide-in unit and/or» to the door of the cable terminal compartment. The position of the earthing switch can be checked via a window in the door. Surge arresters There is sufficient room in the cable terminal compartment for surge protection. Cable terminal Depending on the current, up to 8 cables per phase can be connected. The power cable is fed from below, or, upon request, from above as well. Optional accessories» Transport trolley for circuit breakers» Lifting equipment for the shutters» Crank for circuit breaker slide-in unit» Switching lever for earthing switch» Double bit keys, or keys for a profile cylinder» Installation material/unit screw connection/crank for mech. release 4 Detail drawing of an incoming or outgoing panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Side frame Low voltage compartment Circuit breaker compartment Metal shutter Vacuum circuit breaker Swing handle lock Door handle Window Cable terminal compartment Earthing switch Current transformer Contact isolator Busbars Insulating bushing Pressure release fl ap Optional: voltage converter and surge arrester Provided by the customer: Foundation-levelling rails/frames

Mechanical layout Functional compartments Every unit consists of four functional compartments:» Busbar compartment (1),» Cable terminal compartment (2),» Switchgear compartment (3),» and Low voltage compartment (4). MV Energy Access from the front The functional compartments are separated both physically and electrically from one another by partitioning and isolating distances. This allows the functional compartments or units to remain live even though other functional compartments are open. 4 Busbar compartment The busbar compartment contains the busbar system which is connected to the upper fixed contacts of the switchgears via branch connections. The busbars are made of electrolyte copper. The busbar compartment of each unit is separated from its neighbouring unit. 3 X 1 Cable terminal compartment In the cable terminal compartment, the power cable is connected to the lower fixed contacts of the switchgears (e.g. circuit breakers) via a branch connection system. The branch connections are made of electrolyte copper. The cable terminal compartment is designed for the optional installation of a three-pole earthing switch, three surge arresters and three current/voltage transformers. The cable terminal compartment is closed off with a floor panel. Depending on the rated voltage, size of the unit and the cross-section of the cable, up to eight 1 or 3 pole cables can be connected. 2 MV Energy Access from the front Switchgear compartment The switchgear compartment contains the insulating bushings with the permanent contacts for connecting the switchgears to the busbars and the terminal compartment. The bushings are made of cast resin and are shielded by the metal shutters. The metal shutters function automatically during the movement of the switchgears from the deployed position to the service position and vice versa. 4 1 1 4 Low voltage compartment The low voltage compartment contains all of the control and protection devices and the wiring of the components. 3 Pressure Our fault arc resistant switchgear systems normally have a pressure to discharge gases in the unlikely event of an arc fault. This is located over the switch cabinets and is installed along the entire system X 5

Basic variant Vacuum circuit breakers The circuit breakers are mounted on the slide-in and can be withdrawn. The procedure can be carried out with a closed door. Control and signal leads are connected to the low voltage compartment by a plug.» Switchgear preferably from Siemens, ABB, TAVRIDA Other manufacturers available upon request.» Slide-in technology» Fixed-mounted technology» Type tested as per IEC 62271-200 / VDE 0671 part 200 up to 12 kv; 3.150 A; 40 ka up to 17,5 kv; 3.150 A; 40 ka» Arc fault tested PM / LSC 2B / IAC AFRL 40 ka; 1 s Rated current 12 kv 17,5 kv 31,5 ka 630 A...1250A 31,5 ka 1600 A...3150 A 40 ka* 1250 A...3150 A Height 2200 mm 2200 mm 2200 mm Height with defl ector plates Height with pressure 2500 mm 2500 mm 2500 mm 2600 mm 2600 mm 2800 mm Width 650/800 mm 800/1000 mm 800/1000 mm 12 kv 17,5 kv 1260 mm 1260 mm * Generator circuit breaker switchgear with ABB VD4G-50 are also possible. Vacuum contactors with HV fuses The vacuum contactor is mounted on the slide-in and can be withdrawn. The procedure can be carried out with a closed door. Control and signal leads are connected to the low voltage compartment by a plug.» Switchgear preferably from Siemens, ABB» Slide-in technology» Fixed-mounted technology» Type tested as per IEC 62271-200 / VDE 0671 part 200 up to 12 kv; 3.150 A; 31,5 ka» Arc fault tested PM / LSC 2B / IAC AFRL 31,5 ka; 1 s Rated current 12 kv 630 A...1250 A 1600 A...2500 A Height 2200 mm 2200 mm Height with defl ector plates Height with pressure 2500 mm 2500 mm 2600 mm 2600 mm Width 650/800 mm 800 mm 12 kv 1260 mm 1260 mm 6

Basic variant Load break switch The fixed-mounted switch disconnector is made for switching and protecting the ring line or transformers (in connection with HV fuse links for short circuit protection) or for current-free switching. Each unit can be designed with an earthing switch with a making capacity for grounding wires.» Switchgear preferably from ABB, Areva» Fixed-mounted technology» Type tested as per IEC 62271-200 / VDE 0671 part 200 up to 17,5 kv; 2.500 A; 25 ka» Arc fault tested PM / LSC 2A / IAC AFRL 31,5 ka; 1 s Options» Load break switch as ring line / branch connection» Load break switch with HV fuse as transformer or outgoing feeder» Separate earthing switch or in combination with load break switch Rated current 12 kv 17,5 kv 630 A...1250 A 630 A...1250 A 1600 A...3150 A 1600 A...3150 A Height 2200 mm 2200 mm Height with defl ector plates Height with pressure 2500 mm 2500 mm 2600 mm 2600 mm Width 650/800 mm 800/1000 mm 12 kv 17,5 kv 1260 mm 1260 mm Measuring field» Slide-in technology» Fixed-mounted technology» Type tested as per IEC 62271-200 / VDE 0671 part 200 up to 17,5 kv; 3.150 A; 40 ka; 1 s» Arc fault tested PM / LSC 2A / IAC AFRL 40 ka; 1 s Options» Fuse-voltage converter combination using slide-in or fixed-mounted technology» Current transformer using fixed-mounted technology Rated current 12 kv 17,5 kv 31,5 ka 630 A...1250 A 31,5 ka 1600 A...3150 A 40 ka 1250 A...3150 A Height 2200 mm 2200 mm 2200 mm Height with defl ector plates Height with pressure 2500 mm 2500 mm 2500 mm 2600 mm 2600 mm 2800 mm Width 650/800 mm 800 mm 800 mm 12 kv 17,5 kv 1260 mm 1260 mm 7

Basic variant Combi-cabinet» Fixed-mounted technology» Type tested as per IEC 62271-200 / VDE 0671 part 200 up to 24 kv; 3.150 A; 31,5 ka» Arc fault tested PM / LSC 2A / IAC AFRL 31,5 ka; 1 s Variants» Vacuum circuit breaker» Vacuum contactor fuse combinations» Voltage converter measurement slide-ins» Current transformer» Measuring sets Rated current 12kV 630 A...1250 A 1600 A...3150 A Height 2200 mm 2200 mm Height with defl ector plates Height with pressure 2500 mm 2500 mm 2600 mm 2600 mm Width 650/800 mm 800/1000 mm 12kV 1260 mm 1260 mm Dual busbar systems» Fixed-mounted technology» Type tested as per IEC 62271-200 / VDE 0671 Teil 200 up to 12 kv; 2500 A; 31,5 ka» Native current 4000 A; 40,0 ka (as per VDE 0101) Variants» Vacuum circuit breaker» Vacuum contactor fuse combinations» Voltage converter measurement slide-ins» Current transformer» Measuring sets 1700 2000 Rated current 12kV 630 A...1250 A 1600 A...3150 A Height 3000 mm 3000 mm Height with defl ector plates 3400 mm 3400 mm 3000 Height with pressure 3600 mm 3600 mm Width 750 mm 1000 mm 12kV 1700 mm 2000 mm 8

High operational safety Mechanical locks The switch cabinets are provided with all of the necessary locking mechanisms to allow for the highest level of reliability and safety for personnel and equipment. Standard safety features» The circuit breakers can only be switched in operating or disconnected position.» The slide-in can only be moved between the operating and the disconnected position when the circuit breaker is switched off. Optional safety features» The slide-in can only be switched from the disconnected to the operating position when the control cable is plugged in.» The control cable can only be unplugged in the disconnected position.» The slide-in can only be switched to operating position if the earthing switch is turned off.» The door of the switchgear compartment can only be opened if the slide-in is in the disconnected position. The shutters are located in front of the contact isolators.» The door of the cable terminal compartment can only be opened if the earthing switch is turned on. The lock can be unlocked using a reset bolt.» The shutter can be locked.» The doors of the switchgear and cable terminal compartment can be locked (optionally with a double bit key or profile cylinder).» When in closed position, all of the doors can be locked with swing handle locks. Lock Pressure release flaps / pressure in accordance with IEC 62271-200 Pressure release and pressure All functional compartments, with the exception of the low voltage compartment, have their own pressure release on the roof of the switch cabinet. Any excess pressure within the switch cabinets as a result of an internal arc fault will open the corresponding pressure release flap. The following options are available depending on the current and ambient temperature:» Smooth pressure release flap up to 1.250 A» Vented pressure release flap > 1.250 A, Diagonal discharge plates for stand alone units These will open in the case of a fault and limit the rise in pressure in the switch cabinet. Ceiling height > 3.000 mm For stand alone units, gases are discharged through 300 mm diagonal deflector plates (on both sides and on the side). Vertical deflector plates on the side of the switchgear conduct the gases out of the switch cabinet when wall mounted. Ceiling height < 3.000 mm The pressure leads outside or to subordinate rooms not accessible by the public (e.g. transformer room) and is closed with a pressure release flap. The optional pressure runs the entire length of the switchgear. 9

Certified safety Maximum protection for equipment and personnel The medium voltage switchgear MV Energy a component of the ENERGOLINE product range, is a complete, type-tested, air insulated switchgear system whose physical properties, have been verified in operating and fault situations in accredited testing institutes in accordance with IEC 62271-200 requirements. arc fault test of a medium voltage switchgear with pressure Type testing» Proof of compliance with high temperature limit» Proof of impact resistance and short-circuit strength» Proof of the AC voltage testing of the main and auxiliary circuits» Proof of short circuit making and breaking capacity of the switchgears» Proof of the making capacity of the earthing switch» Proof of mechanical functionality» Proof of IP protection class» Testing under arc fault conditions Accessibility and operational availability The set-up of the switchgear systems is in accordance with the LSC2B- PM classification as per IEC 62271-200: All compartments can be opened without tools. Locks allow access only when the corresponding medium voltage parts are turned off and are grounded. Busbar, cable and switchgear compartments are partitioned. Other functional compartments and units can remain live even if the main circuit compartment is open. Routine factory testing before delivery As a general rule, every switch cabinet undergoes routing factory testing before it is delivered:» Inspection of the switchgears and wiring,» Conformity with the approved documentation,» Electrical functional testing,» Insulation testing,» Mechanical switching run,» Resistance measurement of the main circuit. In addition of the structural arc fault protection, we also offer solutions for active arc fault protection from all conventional system providers. Principles in accordance with IEC 62271-200 / VDE 0671-200:2008-03 Partition classes PM Metal cladding Operational availability IAC classifi cation MV Energy PI LSC1 LSC2A LSC2B Accessibility A B C FRL IAC A FRL 40 ka, 1s Covered with insulating material The busbars and thus the entire switchgear system must be switched off. The busbars and adjacent switch cabinets can remain live. Other switch cabinets, the busbars and all cable compartments can remain in operation Metal encapsulated switchgear that can only be accessed by electrical professionals Metal encapsulated switchgear with unrestricted accessibility, also for the public. Systems mounted on a mast. Access from the front (F = front), from the side (L = lateral) and from behind (R = rear) Our switchgear offers the best personal protection thanks to the verifi able arc fault qualifi cation IAC A FRL up to 40 ka and one second arc duration. 10

Technical data Standards and directives Switchgear Medium voltage switchgear systems Part 200: Metal encapsulated AC switchgear systems for rated voltages above 1 kv and up to and including 52 kv (IEC 17C/421/CD:2007) DIN IEC 62271-200; VDE 0671-200:2008-03 Devices Earthing switches Circuit breakers High voltage AC current contactors Switch disconnectors DIN IEC 62271-102/A1; (VDE 0671-102/A1:2009-02) IEC 62271-100; EN 62271-100 IEC 60470; EN 60470: IEC 60265-1; DIN EN 60265-1 Electrical parameters Rated voltages Rated voltage U r Rated power frequency withstand voltage U d Rated lightning impulse withstand voltage U p Rated frequency 12 kv / 17,5 kv 28 kv / 38 kv 75 kv /95 kv 50/60 Hz Rated currents Rated currents Rated breaking capacity I SC Rated peak current I p Rated short-time withstand current I k Rated duration of short-time withstand current t k Busbars Branch connections 12 kv bis 40 ka 17,5 kv bis 40 ka up to 80 ka / 63 ka up to 31,5 ka; 40 ka / 25 ka up to 3 s up to 3.150 A /2.500 A 630 A, 1.250 A, 1.600 A, 2.000 A, 2.500 A Mechanical parameters Cabinet measurements Cabinets and support frames Height Width 2.200 mm 1) 650, 800, 1.000 mm 1.260, 1.450 mm 2) Customized adjustments possible Protection classes In accordance with IEC 60529, EN 60529 IP 20 to IP 4X Surface protection Coating as per DIN 43656, Standard coating thickness Support frames, sendzimir galvanized Encasement Epoxy polyester powder 65 µm RAL 7035(upon request) RAL 7035( upon request ) Special colours and double coating available Ambient conditions Rated properties Ambient temperature Relative humidity Maximum elevation -5... +40 C 95 % 1.000 m mean sea level 1) with defl ector plates +300 mm with pressure + 400 mm (31,5 kv) and + 600 mm (40 ka) 2) for doors and rearplate 2x30 mm = 60 mm 11

Directions FEAG Sangerhausen GmbH Gewerbegebiet "Helme-Park" Stiftsweg 1 06526 Sangerhausen Fon.: +49 (0)3464/558-30 Fax: +49 (0)3464/558-410 E-Mail info@feag-sgh.de Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. FEAG Sangerhausen GmbH does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. w w w. e n e r g o l i n e. d e w w w. f e a g - s g h. d e