CLIO 8 CLIO 8 CLIO 8 CLIO 8



Similar documents
CLIO Software. Release 8.0 fw Version Standard. User's Manual

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Audiomatica s CLIO Pocket Electro-Acoustical Portable Measurement System

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Impedance 50 (75 connectors via adapters)

Getting Started with SmaartLive: Basic Measurement Setup and Procedures

FREQUENCY RESPONSE ANALYZERS

CLIO Software. Release 1.4 Version Pocket. Survival Guide

Linear Parameter Measurement (LPM)

FFT Spectrum Analyzers

RF Network Analyzer Basics

A Game of Numbers (Understanding Directivity Specifications)

VT RTA-168 Manual. A Sound Level Meter, Real Time Analyzer, Distortion Analyzer, Polarity Tester.

Direct and Reflected: Understanding the Truth with Y-S 3

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Microphone Test System

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Airborne Sound Insulation

Application Note. Introduction to. Page 1 / 10

Test for I-DEAS FEATURES APPLICATIONS A TRANSIENT POST-PROCESSING SOFTWARE FOR FIXED SAMPLE ORDER TRACKING

SignalPad Data Logging and Analysis Software

Audio Engineering Society. Convention Paper. Presented at the 118th Convention 2005 May Barcelona, Spain

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

Propagation Channel Emulator ECP_V3

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

DS-3000 series Sound and Vibration Real time Analysis System

Automotive. Aerospace. bout Us. Defense. Energy. Maritime. Education. Electronics. and more

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Sound Level Meters Nor131 & Nor132

Spectrum Analyzers. R9211Series. R9211A/9211B/9211C/9211E FFT Analyzer Series. Choice of 4 Types To Fit the Application

Waveform Monitor Audio & Loudness Logging

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis. Application Note

The completely Ethernet-based. protocol enables several imode devices to be linked, using easily-sourced. cables and components.

MICROPHONE SPECIFICATIONS EXPLAINED

TDA W Hi-Fi AUDIO POWER AMPLIFIER

Kit Watt Audio Amplifier

RECOMMENDATION ITU-R BS *,** Audio quality parameters for the performance of a high-quality sound-programme transmission chain

Aus: von Jon Risch. The New Test Signal Phi Spectral Contamination

A Network Analyzer For Active Components

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DEVELOPMENT OF DEVICES AND METHODS FOR PHASE AND AC LINEARITY MEASUREMENTS IN DIGITIZERS

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Sound absorption and acoustic surface impedance

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

11: AUDIO AMPLIFIER I. INTRODUCTION

Development and optimization of a hybrid passive/active liner for flow duct applications

Optimizing IP3 and ACPR Measurements

Price List - including VAT - Effective October US$ Pricing is excluding tax

LMS Test.Xpress Powering personal productivity

Speech Signal Processing: An Overview

One Port Network Analyzer

CBS RECORDS PROFESSIONAL SERIES CBS RECORDS CD-1 STANDARD TEST DISC

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

RightMark Audio Analyzer 6.0. User s Guide

MLSSA Acoustical Measurement System

DCP : D-Mitri Core Processor

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

DRM compatible RF Tuner Unit DRT1

W a d i a D i g i t a l

EDM SOFTWARE ENGINEERING DATA MANAGEMENT SOFTWARE

RoomMatch Utility RMU206 TECHNICAL DATA SHEET. small-format under-balcony fill loudspeaker. Key Features. Technical Specifications

PLENA matrix Digital Sound System Surprisingly Flexible. Powerful Control.

IMPORTANT SAFETY INSTRUCTIONS

Noise. CIH Review PDC March 2012

AM-1. AM-1 Setup Guide for the Polycom Video Conferencing Systems QUICK SETUP GUIDE

DRIVING LOOOONG CABLES

What Audio Engineers Should Know About Human Sound Perception. Part 2. Binaural Effects and Spatial Hearing

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

MUSC 1327 Audio Engineering I Syllabus Addendum McLennan Community College, Waco, TX

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

User Guide FFFA

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

AURA - Analysis Utility for Room Acoustics Merging EASE for sound reinforcement systems and CAESAR for room acoustics

ARTA. User Manual. Program for Impulse Response Measurement and Real Time Analysis of Spectrum and Frequency Response. Version

Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals. Introduction

How To Sell A Talan

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

B3. Short Time Fourier Transform (STFT)

Schindler 3300 / Schindler 5300 Information on noise and vibration.

TI 313 (1.0 EN) d&b Remote network - Integration

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

Dirac Live & the RS20i

RoomMatch Utility RMU105 TECHNICAL DATA SHEET. ultra-compact foreground/fill loudspeaker. Key Features. Technical Specifications

Outperform. Bryston is pleased to announce the HT Series Loudspeaker System

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Swept Sine Chirps for Measuring Impulse Response

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Two year Claritycap research programme finally answers an audio capacitors influence on sound quality.

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

SMARTPHONE AS NOISE LEVEL METER? Jacopo Fogola, Stefano Masera, Vincenzo Bevacqua Environmental Protection Agency - Piedmont Region, Turin, Italy

SESSION ACOUSTIC DI USER S GUIDE

RF Measurements Using a Modular Digitizer

Features, Benefits, and Operation

Transcription:

CLIO 8, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure: - electrical networks - electronic equipment - loudspeaker systems - telephones & hearing aids - environmental noise - rooms acoustics - quality of production lines CLIO 8 runs on a standard PC computer driving the measurement hardware and accessories supplied by Audiomatica; the power, precision and reliability of the resulting instrument is 100% warranted. CLIO 8 is a new design based on a huge work which is the synthesis of more than 16 years experience and excellence in electro-acoustic measurement systems and gives you all the power and flexibility you need. CLIO 8 refines all the well established measurement techniques already implemented in the CLIO system while adding several new functionality.

CLIO 8 MAIN SOFTWARE RELEASES AND VERSIONS CLIO 8 comes in different releases to run the proper Audiomatica analyzer hardware. CLIO 8: Controls the SC-02 + PB4281 PCI/USB Audio Interface (18 bit @ 48kHz). CLIO 8 FW: Controls the FW-01 Firewire Audio Interface (24 bit @ 192kHz). CLIO 8 comes also in different versions up to Quality Control Version for state-of-the-art testing and controlling a production line CLIO 8 MEASUREMENT TECHNIQUES Compared to other measurement systems, CLIO 8 concentrates the power of many different instruments into a single one. Three different measurement techniques are available for system identification and characterization: MLS & LogChirp analysis using either pseudo-random noise or logarithmic chirps as stimuli Sinusoidal Sweeps using sinusoidal signals FFT, RTA and Live Transfer Function letting you the choice of any stimulus, even live music. While other instruments offer one single possible measurement choice, CLIO 8 gives you three alternatives permitting to view the physical phenomenon like frequency response, impedance or other parameters, from three different points of view. The final result will be then validated by the consistency of these measurements: as any expert technician knows, this is the correct approach that should always be adopted. The following specialized control panels are dedicated to other specific measurements: Sound Level Meter a IEC61672 integrating sound level meter with Leq and frequency analysis Linearity and Distortion measures the non linear behavior of an electronic equipment Interactive L-C-R Bridge permits passive components measurement on the fly Wow&Flutter Meter with time and frequency analysis Frequency Counter Beyond measured results you get sophisticated post-processing tools for: Thiele&Small Parameters for loudspeaker characterization ISO 3382 Acoustical Parameters for rooms and auditoria characterization Waterfall plots to evaluate sound decay as 3D or Color graphs Directivity analysis for loudspeaker characterization as Color maps, Circular or 3D plots Wavelet analysis for joint time-frequency loudspeaker characterization Using all the aforementioned measuring and post-processing techniques it is possible to tailor powerful Quality Control scripts that will manage and identify any production line of electronic or electro-acoustic devices. MLS & LOG CHIRP ANALYSIS CLIO 8 implements linear systems measurement with the well established MLS analysis technique now enriched by the possibility of using Logarithmic Chirps. The result is the system s impulse response measurement, by means of sophisticated algorithms; this lets you perform accurate anechoic analysis of loudspeakers and room acoustics evaluation. The measurement is highly accurate and extremely fast to execute; the data recorded by the computer, can be instantly analyzed or stored for later processing. What MLS & LogChirp analysis gives you: Frequency response Phase response, minimum and excess. Group Delay Impedance measurement Step response Energy-Time curve (ETC) Schroeder reverberant decay Impulse response Frequency response The actual software release permits, among other features, the following: Sequence length from 4k to 256k points Input signal autorange for optimum signal to noise ratio

Selectable analysis window Manual or continuous programmable time average Loop function with continuous measurement Mathematical operations on data in memory Automatic merge between near and far field Selectable smoothing (1/2 to 1/12 of octave) SINUSOIDAL ANALYSIS CLIO 8 executes sinusoidal analysis with a digital filtering of input signal to achieve the highest noise-immunity; in this way you add the power of the PC to the most traditional frequency analysis. The sinusoidal technique is oriented to: Frequency response Phase response Continuous and stepped sweeps Frequency resolution from 1/3 to 1/48 oct. Impedance measurement 2nd, 3rd, 4th, 5th harmonic and THD plot vs. frequency Gating system with auto-delay for quasi-anechoic measurements FFT, RTA & LIVE TRANSFER FUNCTION These measurements are implemented with an interactive control panel that permits the simultaneous display of time and frequency domains. Three operating modes: Narrowband FFT Octave bands RTA LIVE transfer function The main features are: Two channels measurement and display Internal trigger with programmable delay FFT from 256 points up to 128k points Linear or exponential averaging Max hold and min hold functions Linear or logarithmic frequency axis 1/3 octave or 1/6 octave RTA display Equal Loudness Contours display Frequency smoothing With FFT it is possible to easily execute bursted distortion measurements delivering, for a definable short period of time, very high power to the load. MULTI-METER & SIGNAL GENERATOR This multi-meter control panel is a real-time, interactive, measuring instrument giving the following functionality: SPL Meter (dbspl, dba, dbc) Millivoltmeter (V, dbv, dbu, dbr) Frequency Counter (Hz) Distortion meter: THD and IMD (%, db) L-C-R Bridge (H, uf, Ohm) Crest Factor Fast and Slow integration The programmable signal generator is capable of Sinusoidal response + harmonics Narrowband FFT Octave bands RTA LIVE transfer function Multimeter and signal generator

the following functions or signals generation: Sinusoids with burst and FFT bin round Two sinusoids Multitones All Tones Linear or Logarithmic Chirps MLS (Maximum Length Sequences) White noise Pink noise Wave files (.wav) playback and save IMPEDANCE MEASUREMENTS AND THIELE&SMALL PARAMETERS The impedance measurements can be done with a direct connection to the analyzing hardware or with an external amplifier and a sensing resistor both in constant current or constant voltage configurations; the evaluation of speaker parameters uses the added-mass or known-volume methods and least square error routines. WATERFALL AND DIRECTIVITY The Waterfall and Directivity post processing routines give CLIO 8 the possibility of making 3D or Color plots by adding a third dimension (time or degrees) to classical amplitude-frequency graphs. Impedance and T&S parameters Waterfall Color Waterfall Waterfalls are used to characterize the anechoic sound decay of a loudspeaker or the sound decay in a room. The Waterfall post processing permits the following 3-D or Color types of analysis: Cumulative spectral decay (CSD) Energy Time Frequency (ETF) Directivity analysis characterizes the radiation of a loudspeaker versus vertical or horizontal angle. The Directivity post processing permits the following analysis: 3-D directivity (waterfall like) Color map directivity Classical polar plots WAVELET ANALYSIS The Wavelet Analysis tool allows to post-process impulse responses and to create color plots of the energy of the signal versus time and frequency. The tool is similar to the Energy Time Frequency analysis but, since it is based on wavelet transform Directivity color map Circular polar plots Wavelet

instead of Fourier Transform, does not suffer from a fixed time-frequency resolution. Leq ANALYSIS With the Leq Analysis control panel it is possible to execute real-time capture and level measurement of any kind of signal present at CLIO s input. The behaviour of the instrument closely resemble that of a graphical level recorder plus direct-todisk data capture. When analyzing an acoustical event this control panel gives you complete informations about the equivalent continuous sound level (Leq) and related quantities according to IEC 61672 standard; if used together the FFT frequency analysis you get a complete integrating sound level meter. ACOUSTICAL PARAMETERS With the Acoustical Parameters control panel it is possible to evaluate the acoustical behaviour of a room and carry out sophisticated post processing of a measured impulse response to calculate the acoustical parameters as defined by the ISO 3382 standard. These quantities describe the behaviour of auditoria, concert halls and are applicable to any room intended for speech or music reproduction. LINEARITY AND DISTORTION Linearity and Distortion analysis is a complete tool to inspect the non linear behavior of any electronic equipment as power amplifiers or preamplifiers. Up to 1250W/8Ohm (higher with external attenuator) THD vs. input or output SMPTE, DIN, CCIFF Intermodulation DUT s gain and deviation from linearity Leq analysis ISO 3382 Acoustical Parameters Distortion vs. output power WOW & FLUTTER ANALYSIS CLIO 8 executes Wow & Flutter analysis measuring the frequency modulation that follows instantaneous speed variations due to mechanical imperfections in analog recording or playback devices. IEC and NAB standards Time and frequency display CLIO 8 USER INTERFACE The various control panels give you the impression of facing a real instrument. The software displays multiple curves giving you powerful editing capabilities together import and export facilities as a link to simulation programs. Featuring: Measurement session management with snapshot of current desktop ASCII data output Enhanced Metafile, Bitmap, PNG, GIF, JPEG graphics export Linearity analysis Wow & Flutter

QUALITY CONTROL The Quality Control software extension for CLIO 8 is a powerful suite for executing state of the art production line testing. CLIO 8 QC implements all the measurement techniques found in the standard software adding a versatile script processor that handles the test sequence most appropriate for your needs. CLIO 8 QC is able to test the production of loudspeakers, drivers, microphones, amplifiers and any other electroacoustic device. CLIO 8 QC can interact with external hardware or production line controllers in addition to PC peripherals, computer networks or with custom written software to implement a fully automatic line. CLIO 8 QC is also able to behave as a TCP/IP measurement server to implement your custom written code. Some of the measurements possible: Frequency response using MLS, LogChirp or Sinusoidal Sweep Impedance response using MLS, LogChirp or Sinusoidal Sweep Rub & Buzz detection Polarity Single harmonic or THD response with Sinusoidal Sweep Narrowband FFT analysis with definable stimulus T&S parameters Sensitivity Frequency THD IMD Noise POWERFUL HARDWARE CONTROL The key feature of the CLIO System running CLIO 8 is the precision, laboratory grade, hardware control that gives you complete, instant access to all the measurement parameters and let you easily interact via software to adapt your measurement interface to any environmental need; using CLIO you get results that are 100% warranted by the hardware interface built by Audiomatica. Separate inputs management and control Free running Peak Meter to monitor input signal Input polarity control 0.1dB output level control Output DC voltage control (only SC-02) CLIO 8 also integrates the software control for external hardware: Model 1, 2, 3 and 4 Amplifier & SwitchBox Turntables General Purpose I/O bits PC REQUIREMENTS CLIO 8 FW: Pentium IV, Windows XP or Vista CLIO 8: Pentium III, Windows 2000 or XP AUDIOMATICA VIA MANFREDI 12-50136 FIRENZE-ITALY TEL:+39-0556599036-FAX:+39-0556503772 E-MAIL: info@audiomatica.com WEB:www.audiomatica.com,www.cliosystem.com ELECTRICAL & ACOUSTICAL TESTS