Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07



Similar documents
The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

DIVISION 4300 STORM DRAINAGE

Royal Seal Gasketed Sewer Pipe

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION POLYVINYL CHLORIDE (PVC) PIPE

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

SPR PE Steel Reinforced Liner

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Section 2100-Trenching and Tunneling

pvc well casing & drop pipe

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SECTION NONREINFORCED CONCRETE SEWER PIPE

Fabricated Drainage Products

Drainage Solutions and Water Treatment / Single-wall corrugated drainage tubing is ideal for agricultural and. Durable Economical Wide range of sizes

Concrete Pipes. Concrete Pipes

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

Module 3 : Sewer Material. Lecture 3 : Sewer Material

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

Pipes and Fittings for Gravity Sewer Mains. SewerMAX

HIGH DENSITY POLYETHYLENE

Module 3: Sewer Material Lecture 3: Sewer Material

Ultra-Rib PVC Storm Sewer Pipe 8" - 30"

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Use of Corrugated HDPE Products

INDEX. Sec. No. Items Page Nos.

SECTION STORM DRAINAGE TABLE OF CONTENTS

Flowtite Jacking Pipe

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Beacon Hill Sewer District Standard Specifications

Section SEWER PIPE INSTALLATION AND TESTING

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Wastewater Capital Projects Management Standard Construction Specification

SECTION STORM DRAIN SYSTEM

PVC Gasketed & Solvent Weld Pipe

8-11 Structural Analysis and Fill Height Tables Pipe Cover Shallow Cover Installation Fill Height Tables...

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

N-12 Pipe. The high-performance future of engineered drainage

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

City of Lincoln, Nebraska STEVENS CREEK BASIN TRUNK SEWER TECHNICAL MEMORANDUM NO. 5 PIPE MATERIAL SELECTION TABLE OF CONTENTS

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

SANITARY SEWER SPECIFICATIONS

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

X Planning X Quality X Maintenance & Operations

Pipeline Replacement using Relining

SECTION 603 SANITARY SEWER FORCE MAINS

CHAPTER 6 - SANITARY SEWER

Haviland Drainage Products Co. Box 97 Haviland, Ohio Ph. (419) Fax (419)

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Volume III: PVC Solvent. Weld BDS Sewer & Drain Piping Systems. Mechanical Technical Manual Series

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

HYLINER AKS HDPE LINING

CHAPTER 850 PHYSICAL STANDARDS

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications

Carlon Bore-Gard and Boreable Multi-Gard Raceway

SECTION POLYVINYL CHLORIDE (PVC) PIPE

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

SECTION 724 PIPE CULVERTS

ITD Pipe Materials Selection & Specification Procedures. July 2011

Ridgistorm-XL - the latest innovative

CULVERT AND STORM SEWER PIPE MATERIAL POLICY ON FEDERALLY FUNDED LOCAL AGENCY PROJECTS UPDATED March 2013

OAR52 A-1 (September, 1981)

Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe

Nebraska Department of Roads Drainage and Erosion Control Manual December 2011 Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY

SECTION 5: SANITARY SEWER SYSTEM DESIGN

SECTION STORM DRAINAGE SYSTEM

SECTION SANITARY SEWER PIPE

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

02780 LINER FOR SEWER REHABILITATION

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

SUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*

Corrosion protection linings. Issue 1

Let Us Give Utilities the Respect that they Deserve.

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Section 402. STORM SEWERS

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

Sewer Line Rehabilitation

SECTION BUILDING SEWERS. B. Connection of building sanitary drainage system to municipal sewers.

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 21

HDPE Drainage Products

ABOUT US ABOUT PE THE DEFINITION OF POLYETHYLENE

Transcription:

Sanitary Sewer Pipe

Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness during installation and simplified field fabrication. With over 100 years of experience, Hancor products have an established reputation for quality and performance! Now that reputation is available in sanitary sewer pipe. Ten years of field trials, research and development have resulted in a High Density Polyethylene (HDPE) sanitary pipe that is a cost-effective alternative to traditional materials. Because a watertight joint is critical in sanitary applications to prevent water infiltration and sewer exfiltration, the Hancor patented reinforced bell-and-spigot design is necessary. The joint has been field proven in watertight storm drainage, low head pressure applications, and sanitary sewer applications. To meet the deeper burial depths of sanitary sewer lines, a flexible pipe provides the best structural system. In fact, the high performance resins that SaniTite utilizes are 100% virgin HDPE Material and are designed for a minimum 100 year design life. Available in sizes from 24" to 60", SaniTite is ideal for industrial and municipal sanitary trunk and transmission lines. 100 Year Design Life Patented Bell-and-Spigot watertight Joint

Hancor Sanitite Sewer PIPE SPECIFICATION Scope This specification describes 24" - 60" (600-1500mm) Hancor SaniTite Pipe for use in gravity flow applications, such as industrial wastewater and municipal sanitary sewers. Pipe Requirements Hancor SaniTite Pipe shall have smooth interior and annular exterior corrugations. 24" - 60" (600-1500mm) pipe diameters shall meet all the requirements of ASTM F2306. Hydraulics A Manning s coefficient of not less than 0.012 shall be used for design. Joint Performance Pipe shall be joined with the Hancor SaniTite composite joint meeting or exceeding the short-term test requirements of ASTM D3212. 24" - 60" (600-1500mm) diameters shall have a reinforced bell-and-spigot. The reinforced bell shall include bell reinforcement by means of multiple ceramic polmer wraps installed by the manufacturer. The spigot shall have two gaskets which can be fully inserted into the bell. Hancor Service: Hancor representatives and engineers are committed to providing you with the answers to all your questions, including specifications, installation, backfill recommendations and more. Gaskets shall be made of polyisoprene meeting the requirements of ASTM F477. Gaskets shall be installed by the pipe manufacturer and covered with a removable wrap to ensure the gasket is free from debris. A joint lubricant available from the manufacturer shall be used on the gasket and bell during assembly. SaniTite Joint

Field Pipe and Joint Performance Testing To assure watertightness, field performance verification may be accomplished by testing in accordance with ASTM F1417 or ASTM C969. Appropriate safety precautions must be used when field-testing any pipe material. For long runs of pipe, joint to joint testing should be considered. Fittings Couplings, elbows, reducers, tees, wyes, laterals and other fittings shall be capable of withstanding all operating conditions when installed. Fittings may be molded or fabricated. Fabricated fittings shall be welded at all accessible interior and exterior junctions. Material requirements Pipe shall be made of virgin polyethylene resins that conform to ASTM F2306. The pipe shall be made of a material meeting the requirements of cell classification 435400C or higher in accordance with ASTM D3350. Average NCLS test specimen results must exceed 24 hours with no test result less than 17 hours. Features and Benefits Patented reinforced bell-and-spigot maintains a sure seal pipe joint. HS-25 (Highway traffic loads) rated with minimal cover. Tough, high impact resistant HDPE, for less breakage than conventional sewer products. Available in 20.5' (6.24m) lengths for shallow burial and shorter lengths to accommodate trench boxes. Lightweight, easy to handle, easily cut in field. Bell-and-spigot joint for ease and speed of connection. High UV resistance for hassle-free site storage. Smooth liner for greater hydraulics. Installation Installation shall be in accordance with ASTM D2321, with the exception that minimum depth for backfill over the top of the pipe shall be 1 ft. (0.3 m), for 24" - 48" (600-1200mm) diameters, and 2 ft. (0.6 m) for 60" (1500mm) diameter. Pipe Dimensions Pipe dimensions shall be as shown in Table 1 below: Nominal Diameter, in. (mm) Pipe I.D., in. (mm) 24 (600) 36 (900) 48 (1200) 60 (1500) Pipe O.D., in. (mm) 27.1 (719) 41.7 (1059) 53.6 (1361) 66.3 (1684) Inner Liner Thickness minimum in. (mm) 0.07 (1.8) 0.095 (2.4) 0.105 (2.7) 0.105 (2.7) Min. Pipe Stiffness minimum pii (KN/m 2 ) 34 (235) 22 (150) 18 (125) 14 (95) *Values provided are for reference purposes only. *Check with sales representative for availablity by region.

High Performance Engineered Materials Hancor SaniTite pipe is made from virgin High Density Polyethylene (HDPE) material, which is arguably the best material to withstand abrasion, and corrosive attacks from acidic and alkaline soils as well as the harsh chemicals found in industrial waste and municipal sewers. Alternate materials such as PVC compounds manufactured in accordance with ASTM D1784 are allowed to use fillers (typically crushed limestone), which reduce the virgin component s long-term strength properties and impact strength capability. HDPE specifications have no allowance for fillers or recycled material when conforming to ASTM D3350. Virgin material assures the physical properties meet the minimum classification of 435400C as defined and described in ASTM D3350. This assures impact strength and long-term service life for the tough, real world environment of sanitary sewer. Advanced Engineered Joint Performance The Hancor patented composite joint system is used to assure long-term watertightness. Joint tightness exceeds the minimum requirement of ASTM D3212. The composite jointing system not only meets the laboratory test of ASTM D3212 but has been shown to provide continuous watertight performance for the over 100-year life of the system. At the heart of success for the jointing system is the reinforced bell-and-spigot technology. Contractor s Choice for Construction High performance HDPE assures owners and contractors of the structural integrity of the Hancor SaniTite pipe. This all adds up to a more installation friendly pipe. Quality Engineering and Manufacturing Hancor sanitary sewer pipe uses state-of-the-art seamless construction with annular corrugations which provide superb structural integrity. Some manufacturers use helically wrapped thermoplastic pipe technology, which provides opportunity for seam separation and splitting. Additionally, Hancor sanitary sewer pipe has integral bells and spigots formed by continuous extrusion without the use of postproduction welding. This tough, highly engineered product is constructed with higher performance material built to withstand the rigors of the installed environment and handle impacts well in excess of its rivals. Outstanding Hydraulics in Real Applications Hancor sewer pipe is a dual wall product with a smooth waterway. Advanced material technology in combination with co-extruded liners translate into smooth liners. With most EPA design criteria dictating a Manning s coefficient consistent with that of RCP, HDPE offers a smooth liner. Typical inservice field conditions result in a design Manning s coefficient of not greater than 0.012. complete line of fittings and accessories In addition to a superb pipe product, Hancor offers a complete line of fittings, manhole connection adapters, and accessories.

Direct Contact Customer Service 888-FOR PIPE (367-7473) Fax 888-FAX PIPE (329-7473) 24 hours a day Electronic Media Web Site Find market- and application-specific information and the latest industry news at our On-Line Pipeline www.hancor.com Hancor Terms and Conditions of Sale are available on the Hancor web site, www.hancor.com 401 Olive St., Findlay, OH 45840 Hancor and SaniTite are a registered trademarks of Hancor, Inc. 2008 Hancor, Inc. 2890 1160/1108