System Assessment Capabilities for Fossil Fuel Power Stations

Similar documents
Technical Services. Technical Services. LifeCycle Advantage. Educational Services. Consulting. Technology Advantage

Engineering and Technical Services

Capabilities Overview

Power Recovery Turbines

Fire Protection Pumps

Pumps for CO 2 Capture, Transportation and Storage

Asset Management and Optimization

Aftermarket Parts and Services

Education and Training

Equipment Performance Monitoring

A CASE STUDY: PERFORMANCE AND ACCEPTANCE TEST OF A POWER AND DESALINATION PLANT. Keywords : Power Plant, Boiler Capacity, Electrical Power

Steam Turbine Concepts for the Future Volatile Power Market

QL Series Vertical, Double-Suction, Twin-Volute Turbine Pumps

Steam System Best Practices Condensate System Piping

4 th EU Sout Africa Clean Coal Working Group Meeting

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

Pump Division MNR MND. Absorber Recirculation Pumps. Bulletin PS (E)

Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler

Proven Utility Solutions from John Zink Hamworthy Combustion.

The Technology and Business of Power Andrew Valencia, P.E. Lower Colorado River Authority

SOLARPACES: Development of an integrated solar thermal power plant training simulator

DE-TOP User s Manual. Version 2.0 Beta

C. starting positive displacement pumps with the discharge valve closed.

Recommended Practice for Software Acquisition

OROT RABIN POWER STATION UNITS x 350 MW

DESIGN CHALLENGES AND OPERATIONAL EXPERIENCE OF A MEGA MED SEAWATER DESALINATION PLANT IN TIANJIN

CHAPTER 9: WATER HEATING

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

Mechanical Engineering Technician- Plant Technician

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Backup Fuel Oil System Decommissioning & Restoration Plan

10 Nuclear Power Reactors Figure 10.1

COGENERATION. This section briefly describes the main features of the cogeneration system or a Combined Heat & Power (CHP) system. 36 Units.

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

EFFICIENT ENERGY SUPPLY (ELECTRICITY AND DISTRICT HEAT) FOR THE CITY OF LINZ

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

UTILITIES AND ENERGY MANAGEMENT

Mechanical Seal Piping Plans

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

Study of a Supercritical CO2 Power Cycle Application in a Cogeneration Power Plant

Supporting Service Solutions

SRS: THE STANDARDIZED REPOWERING SOLUTION FOR 300MW STEAM POWER PLANTS IN RUSSIA. Matthias Fränkle Siemens Power Generation (PG), Germany

PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS

Concentrated Solar Power. Parabolic Trough Power Tower

POWER GENERATION: GAS TURBINES, CO- GENERATION, COMBINED CYCLE PLANTS, WIND POWER GENERATION, AND SOLAR POWER:

Quik Lining Systems Heater Owners Guide

HVAC System Optimization

English version. Manual for Determination of Combined Heat and Power (CHP)

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Layout Planning of Waste-to-Energy Plants

FULL ELECTRICAL LNG PLANTS: HIGHEST AVAILABILITY AND ENERGY EFFICIENCY THROUGH OVERALL SYSTEM DESIGN

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

The Piping System Model a New Life Cycle Document. Elements of the Piping System Model

Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Element D Services Plumbing

Steam and hot water boiler systems for industrial and municipal power generation Dr.-Ing. Wolfgang Sobbe VKK Standardkessel Köthen GmbH

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

CSP-gas hybrid plants: Cost effective and fully dispatchable integration of CSP into the electricity mix

How To Clean Up A Reactor Water Cleanup

presents Hydraulic Separation Beyond Primary / Secondary Piping

Natural Gas Conversions of Existing Coal-Fired Boilers

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Cooking at the Speed of light!

Classification and Qualification STANDARDS

Efficiency Metrics for CHP Systems: Total System and Effective Electric Efficiencies

Printing and Publishing Energy Savings Guide

Steam Generation Solutions

SAMPLE CHAPTERS UNESCO EOLSS

Ship Propulsion/Electric Power Hybrid System Recovering Waste Heat of Marine Diesel Engine

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design

Real-time Monitoring Platform to Improve the Drinking Water Network Efficiency

Condensing Boiler Efficiency

VARIABLE VOLUME / VARIABLE SPEED SYSTEMS APPLICATIONS

Loviisa 3 unique possibility for large scale CHP generation and CO 2 reductions. Nici Bergroth, Fortum Oyj FORS-seminar

I. STEAM GENERATION, BOILER TYPES

Power Generation Service Life Cycle Management for Power Plants

Advanced Monitoring and Diagnostics:

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

Performance Analysis of Thermal Power Station: Case Study of Egbin Power Station, Nigeria

MODELBASED DIAGNOSTICS, MAINTENANCE ON DEMAND AND DECISION SUPPORT ON BOILERS

HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, DC June 16, 2011

AE BIO SOLAR AE BIO SOLAR HYBRID PLANT SOLAR/BIOMASS ADESSO ENERGIA SRL HYBRID PLANT SOLAR/BIOMASS THE BEGINNING OF A NEW ENERGY PRESENTATION

Senoko Power Station CCP2 performance increase with focus on efficiency. Answers for energy.

Integrated Performance and Condition Monitoring at DuPont

Energy Efficiency in Steam Systems

Upper Occoquan Service Authority Centreville, Virginia A Case Study

Committed to make a better world

Low grade thermal energy sources and uses from the process industry in the UK

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Sample - Existing Building Commissioning Plan

Transcription:

System Assessment Capabilities for Fossil Fuel Power Stations Technical Services LifeCycle Advantage Educational Services Consulting Technology Advantage

The mission of Flowserve Technical Services is to help power station operators optimize unit performance and maximize profitability. This is accomplished by a team of more than 150 design and applications engineers stationed around the world. Comprehensive system assessments using advanced data collection tools and methods coupled with sophisticated modeling techniques provide the blueprint by: Identifying opportunities to reduce energy usage of major systems and critical equipment Diagnosing the root cause(s) of underperforming systems and premature equipment failure, regardless of OEM or type Identifying opportunities to improve operator safety Developing solutions for chronically problematic equipment using life cycle cost (LCC) projections 2

System Assessment Capabilities for Fossil Fuel Power Stations A Systems Approach Flowserve Technical Services is fully committed to maximizing station profitability by reducing the total life cycle costs of pumping systems. And while boiler-feed and circulating water pumps are critical components of any power station, Technical Services recognizes that no pump operates in isolation. It is part of a system with myriad other components, all with crucial roles in achieving optimal plant efficiency and availability. That s why Technical Services is system driven rather than component driven. Through this holistic approach, a truly effective solution can be implemented. Assessments by Technical Services can help plant operators optimize unit performance by identifying deficiencies in systems such as: Feed water Circulating water Auxiliaries Feed Water System Assessments Over a station s life, perhaps no single power plant system can impact plant efficiency more than the feed water system. Numerous factors varying plant output, degradation of equipment and system modifications lead to inefficient plant operation along with increased maintenance costs and, ultimately, reduced profits. One example of this is the case of a main power turbine re-rate. Many power generating facilities re-rate their main power turbine with the expectation of a 5% to 10% increase in plant load rating. Once the re-rated turbine is up and running, however, they struggle to meet the proposed output. Often, the problem is not with the new turbine but with the condition of the systems that support it. In these cases it is common to find the original operational requirements of the supporting condensate pumps, high-pressure feed pumps, booster pumps, heater drain pumps and heater systems are no longer appropriately sized for the re-rated system. Technical Services understands that to truly change a plant s output a complete system evaluation must be conducted. To that end, these experts analyze all systems and equipment in the steam cycle, focusing on energy and hydraulic optimization with the most advanced monitoring, diagnostic, modeling and analytical tools. 3

Technical Services Determines Cause of Circulating Water System Inefficiency The Challenge: A multi-unit power station located on a large river suspected the circulating water system supplying Units 1 and 2 was operating inefficiently, resulting in derated performance. Consequently, the station s profitability was negatively impacted. The Assessment: Flowserve engineers conducted a thorough assessment of the system which consisted of four vertical pumps operating in parallel. These pumps provide water to the Unit 1 and 2 condensers, condensate coolers, jacket water coolers and raw water pumps. Outlet to River 1A 1B 2A 2B U1 Cond U1 Cond Cool Raw Water U2 Cond Cool Using non-invasive flow monitoring instrumentation and stateof-the-art wireless technology, Flowserve engineers collected high-resolution data under various operational scenarios. A hydraulic study was performed from which a highly accurate model was developed. Validated with actual field data, this model was used to evaluate the system s response to multiple variables. Flowserve Technical Services engineers determined: U2 Cond Unequal flow distribution existed throughout the system. Flow to the Unit 1 condenser was greater than design in all field test scenarios. Flow to the Unit 2 condenser only reached design level when four pumps were in operation. A significant reduction of flow to both condensers occurred during periods of low river elevation. Low-flow caused increased condenser backpressure in both units, compromising unit power generation during low river level conditions. The Solution: To correct the flow imbalance, Flowserve recommended two circulating water pump trains be retrofitted with higher speed motors to provide greater capacity when the river is low. The hydraulic model was used to verify that two higher speed motors the client already owned would provide the necessary increase in pump capacity. The resulting increase in flow would also reduce the condenser backpressure and improve steam cycle efficiency, increasing station profitability. Circulating Water System Assessments The thermal efficiency of a fossil power plant is largely determined by the pressure of the condenser to which the main power turbine is exhausting. When the actual condenser backpressure is above the design value, steam cycle efficiency declines, resulting in a net loss in power produced. Increased condenser backpressure can be caused by any of several factors, including fouling, poor pump performance, low source water level and air leakage. And while reducing condenser backpressure may seem straightforward, there are numerous pitfalls that must be recognized and avoided when engineering changes to this system. For example, increasing the circulating water flow rate may indeed reduce the condenser backpressure but it may also reduce pump efficiency and cause premature condenser tube failure due to velocity erosion. Technical Services engineers use advanced hydraulic modeling tools and life cycle costing methodologies to evaluate system modifications using actual performance data. They then develop corrective action plans that maximize plant output without compromising equipment efficiency or component mean time between repair (MTBR). Assessments by Flowserve Technical Services can help plant operators identify and rectify the root causes of problems such as: Low circulating water capacity Inefficient condenser performance High condenser backpressure Low component MTBR 4

System Assessment Capabilities for Fossil Fuel Power Stations Auxiliary System Assessments Frequently overlooked, auxiliary systems are integral to a station s overall performance. Flue gas desulfurization systems, heater drain systems, boiler circulating water systems, closed cooling water systems and the like are critical in supporting the primary plant systems and, therefore, need to perform well and efficiently. Technical Services brings the same level of expertise, practical know-how and state-of-the-art technology to optimizing auxiliary systems as they do the feed water and circulating water systems. Comprehensive systems assessments can: Optimize system and component performance Improve system and component efficiency Increase component MTBR Reduce operations and maintenance (O&M) costs The Assessment Process The life cycle of a well-engineered utility pump can easily exceed 35 years. Over time, however, changing operating conditions coupled with equipment degradation can result in their operating far off best efficiency point (BEP). Pump reliability and efficiency are negatively affected and system performance suffers. The impact also extends to the bottom line, where increased maintenance and operating costs can significantly depress plant profitability. Increasing plant profitability is no easy task though. Maximizing unit power generation is key and to do this the performance of the system and all its components must be optimized. Focusing efforts on any single piece of equipment may provide some relief, but the results are marginal at best and typically short lived. Meaningful and lasting improvements can be achieved only by analyzing the system as a whole. Technical Services five-step assessment process has proved highly successful in optimizing the thermal efficiency and increasing the profitability of conventional coal fired units and cogeneration facilities alike. 1. Evaluate symptoms of deficient equipment or underperforming systems by forensically auditing current process parameters, maintenance history and operational demands. 2. Implement a testing methodology utilizing proprietary and non-proprietary collection hardware and software tools to generate actionable data. 3. Analyze data, technical documentation and interviews to delineate root cause solutions. 4. Generate a comprehensive report with recommendations supported by life cycle cost analysis that enables the customer to achieve operational and reliability goals. 5. Provide continued technical and commercial support to secure sustainable and measurable results. 5

Knowledgeable People With Powerful Tools In addition to their pump expertise, Technical Services engineers have extensive experience with power plant systems and process applications. These credentials are augmented with state-of-theart monitoring, diagnostic and modeling technologies, including proprietary Flowserve engineering software and evaluation methods. The result is actionable information that plant operators can use to optimize system performance. Acquiring the Data Performing an in-depth analysis of any fossil fuel power plant system requires the collection of a large amount of historical information and actual current performance data. Experienced Flowserve Technical Services engineers perform extensive on-site audits to define pump reliability issues and maintenance history, operating issues and possible system and component design weaknesses. This is accomplished in part by interviewing power plant staff and by collecting historical data like maintenance files, design and construction data. Technical Services engineers also conduct comprehensive field testing to establish actual performance data. This testing may include the company s proprietary IPS Wireless monitoring and diagnostics hardware and software. Data including pressure, temperature, mass flow, etc., can be recorded in real time at various unit loads. This data is used to validate high-resolution thermodynamic and hydraulic models which are used to identify system deficiencies and predict changes in system performance. The Right Tools for the Job Flowserve engineers use numerous analytical tools for system assessments, including: Powerful elimination schemes (rather than truth tables) to diagnose root cause for vibration-pulsation problems A 48-channel vibro-elastic data acquisition system to allow signature analysis, ODS, field model analysis, etc. Water-steam cycle thermodynamic modeling software Software to model steady state and transient pipe flow in complex pump systems Hydraulic design CFD analysis, flow visualization, energy optimization, erosion modeling, etc. 6

System Assessment Capabilities for Fossil Fuel Power Stations Hydraulic Modeling Removes Guesswork Flowserve uses sophisticated software and techniques to develop highly accurate hydraulic models of plant systems. Validated with real-time field data, these models enable Flowserve engineers and plant operators to: Analyze actual system performance Establish system head loss curves and any process variable, e.g., flow, head, velocity, pressure drop, etc., at any location within the system under various modes of operation Run what if scenarios to determine the impact of proposed modifications Develop a cost-effective action plan that achieves real and measurable improvements in the performance and profitability of the plant Thermodynamic Model Tests Efficiency Using actual performance data obtained during testing, Technical Services engineers can develop a thermodynamic model of a unit s entire steam-water cycle. This model simulates pump and system operation under various system loads. Armed with this information, Technical Services engineers and plant operators can then develop detailed corrective action plans for optimizing system performance, reducing fuel costs and increasing plant profitability. An advanced thermodynamic model also addresses with a high degree of confidence questions regarding: Changes in steam flow to the turbine and its new output, exhaust steam properties and efficiency Changes in feed water heating in terms of new turbine extraction steam flow parameters, steam pressure, turbine operating values, plant output and efficiency Changes in circulating water flow through the condenser and its effect on heat removal capability, backpressure reduction and condensate temperature Flowserve Identifies Root Cause of 30 MW Derate The Challenge: While running on a single train, a large East Coast power station experienced an unexplained 30 MW derate in its 800 MW unit. The associated loss in revenue is conservatively estimated at $470,000 per month. The Assessment: Flowserve Technical Services engineers performed a study of the feed water and LP heater drain systems. Wireless technology was employed to obtain performance data under varying unit loads, producing a high-resolution profile capable of capturing transient conditions. This data was utilized to validate a hydraulic model which was then used to evaluate the system s response to multiple variables. Analysis of the model revealed: The heater drip pump was underperforming the OEM curve by 15% due to reduced system demand. Level instability in the undersized heater drip tank caused excessive dump valves cycling to maintain the desired level. Hot water from the heater drip system was being dumped into the condenser instead of the feed water system, reducing the thermal efficiency of the unit. The Solution: Flowserve engineers recommended replacing the heater drip pump with a smaller, vertical inline model fitted with a variable frequency drive (VFD). The VFD will allow the pump to operate even at low flows, stabilizing the heater drip tank level and restoring the thermal efficiency of the unit. In addition to the revenue made on the restored 30 MW, Technical Services estimates the plant will realize energy cost savings of $1.3 million (U.S.) per year due to this change. The Maintenance and Modifications Supervisor at the plant said: Flowserve s system review has enabled us to make maintenance and operations decisions based on real data and analysis, rather than assumptions and history. 7

technical services Bulletin ISG-TS-4 (E) Printed in USA. February 2010. Flowserve Corporation To find your local Flowserve representative: For more information about Flowserve Corporation, visit www.flowserve.com or call USA 1 800 728 PUMP (7867) flowserve.com USA and Canada Flowserve Corporation 5215 North O Connor Blvd. Suite 2300 Irving, Texas 75039-5421 USA Telephone: 1 937 890 5839 Europe, Middle East, Africa Flowserve Corporation Gebouw Hagepoint Westbroek 39-51 4822 ZX Breda Netherlands Telephone: (31) 76 502 8920 Latin America Flowserve Corporation Boulevard del Cafetal Edificio Ninina, Local 7 El Cafetal - Caracas Venezuela 1061 Telephone: 58 212 985 3092 Telefax: 58 212 985 1007 Asia Pacific Flowserve Pte. Ltd. 10 Tuas Loop Singapore 637345 Telephone: 65 6771 0600 Telefax: 65 6779 4607