SAA Simulator. Instruction Manual. Revision 0



Similar documents
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Config software for D2 systems USER S MANUAL

Printer Driver Installation Manual

BMV-602 Data Link Manual

Copyright 1999 by EPSON America, Inc. 3/99 Torrance, California, USA

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide

NortechCommander Software Operating Manual MAN R6

InventoryControl for use with QuoteWerks Quick Start Guide

Volume AGKSOFT. Ruby VeriFone Back Office Software. Ruby VeriFone Guide

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

Road Sensor Control Software for Retroreflectometer LTL - XL

Animated Lighting Software Overview

Microsoft Access Rollup Procedure for Microsoft Office Click on Blank Database and name it something appropriate.

DriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186

IMPORTANT! CPD 8424R1

QUICK GUIDE FOR. Installing Nokia Connectivity Cable Drivers

ReturnStar HDD Lock V3.0 User Manual

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

LifeSize Networker Installation Guide

FN:PCMCSET-M1.DOC. PCMCSET SOFTWARE for ATS Master Clocks System Clocks and Displays

TE100-P21/TEW-P21G Windows 7 Installation Instruction

A-Series Data Loggers PRODUCT MANUAL

ChipScope Pro Tutorial

hp digital home networking wireless USB network adapter hn210w quick start guide

USB Driver Installation for Windows XP

Avigilon Control Center 5 System Integration Guide. for Jacques IP Audio Intercom System

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Installing Global Logger USB Drivers

Productivity Software Features

Machine Edition USB Hardware License Key did not get recognize inside Virtual Machine

Example Program for Crestron - Setup Guide -

Wire Manager. for Business Online Banking Quick Reference Guide

Checkmate 5.3.1: Hosted Solution Setup August 7, 2009

Raptor-CAN User Manual

AN220 USB DRIVER CUSTOMIZATION

Connecting your Omega/BetaPAT PLUS to a PC via a USB

ABUS WIRELESS ALARM SYSTEM

ClickCall. User Guide. Please read this manual carefully before operation. Retain it for future reference.

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Avigilon Control Center 5 System Integration Guide. Video and Event Viewer for Lenel OnGuard

Installing the Gerber P2C Plotter USB Driver

Installation Guide for LynxClient

Operating Instruction MEW01652 Revision -

FX-BTCVT Bluetooth Commissioning Converter Commissioning Guide

VM-4 USB Desktop Audio Device Installation Guide

VM-8 USB Desktop Audio Device Installation Guide

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Basic Use of the SPC Feature on 1100R+/H+ Testers

Sending SMS Messages and s

Connecting your Blackberry to Aliant Hosted Exchange. Instructions for connecting Blackberry hand-held devices to Aliant Hosted Exchange

Title Page. Installation Guide. PowerChute plus Version for Windows 95

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

F9 Integration Manager

Operating Instructions

AXIS 5810 A Bluetooth Print Plug. Quick Start

SIGNiX: Digital Signature Service

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

Installation & Configuration Guide User Provisioning Service 2.0

SA-9600 Surface Area Software Manual

OASIS Application Note

Caller ID Tracker Summit Computer Networks, Inc.

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

User Guide for Payroll Service (APS+)

WeatherLink for Emergency Response Teams Addendum

Series 2000 Audit and Calibration Users Guide

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

Payment Processing Frequently Asked Questions. Microsoft Dynamics RMS

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

BCD TC-100 Table of Contents

Getting Started with CardScan. Chapter

AN220 USB DRIVER CUSTOMIZATION

RSA Authentication Manager 7.1 Basic Exercises

VinNOW/TSYS Integration Setup. Overview

Infinity C Reference Guide

Temperature & Humidity SMS Alert Controller

InQFlow. Administrator Guide. March 2009 Constellation HomeBuilder Systems, Inc. All right reserved

DIAL-UP DATA. User s Guide

USB Guide Port Adapter User Manual Model GPUSB

Connecting instruments serially to your computer

Elite MicroPrint. CDR / DVDR Inkjet Printing. Hardware Installation and Setup Guide

Scheduling Data Import from Avaya Communication Manager into Avaya Softconsole MasterDirectory

Corrosion Data Management Software Version 3.1.3

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Vicon Flash Upgrade Software

User Manual. (updated December 15, 2014) Information in this document is subject to change without notice.

SOFTWARE SERVICE BULLETIN

Data Analysis Software

Table of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10

Quick Installation Guide Network Management Card

Password Reset Feature Quick Start Guide

HP USB Smartcard CCID Keyboard. User Guide

ROYAL REGISTERLINK USER'S GUIDE

TheFinancialEdge. Fast! Guide

Signature Center Getting Started Guide

TimeValue Software Due Date Tracking and Task Management Software

Transcription:

Instruction Manual SAA Simulator Revision 0 Measurand Inc. 2111 Hanwell Rd. Fredericton, NB, Canada E3C 1M7 tel: 506-462-9119 fax: 506-462-9095 Email: SAAsupport@measurand.com http://www.measurand.com Copyright 2015

This page was left blank intentionally.

SAA Simulator Notices Measurand shall have no liability for incidental or consequential damages of any kind arising out of the sale, installation, or use of its products. Please read this document and any notes and instructions carefully before proceeding with installation and operation. The information herein is subject to change without prior notification. ShapeAccelArray (SAA) is covered by patents including: 6127672, 6563107, 7296363, WO 02/055958, WO 98/41815, 5352039, 2427421 and others pending. Measurand Software is copyrighted. Any unauthorized use is strictly prohibited. In addition to this manual, a prerequisite to installing and using the SAA is to study the SAA Description & Installation Manual and any other manuals covering hardware or software relevant to use of SAAs in your particular installation. All Measurand manuals are available through our website (http://www.measurandgeotechnical.com/software.html) or through SAASuite. Revisions No: 0 February 2015 i

This page was left blank intentionally. ii February 2015

Table of Contents SAA Simulator Table of Contents... iii List of Figures... iv 1. Introduction... 1 1.1 Description...1 2. Using SAASim... 2 2.1 SAACR_FileGenerator & LoggerNet...2 A. Troubleshooting... 5 B. Wiring Diagrams... 7 C. Support (Help)... 8 C.1 Online Documents...8 C.2 Online Tutorial Videos...8 C.3 Online Software Downloads...8 C.4 Sales...8 February 2015 iii

List of Figures Figure 1.1: SAASim.... 1 Figure 2.1: SAASim connected to two SAA232s in an Earth Station with a CR800 Logger.... 2 Figure 2.2: The SAA232 with SAA1 (Serial Number 67091) must be connected to COM Port 1 on this Earth Station while the SAA232 with SAA2 (Serial Number 62189) must be connected to COM Port 2 on this Earth Station.... 3 Figure 2.3: These settings are for Auto Conversion and can be changed.... 3 Figure A. 1: Opened as a comma delimited file.... 5 Figure A. 2: Can open several SAA.cal files at once.... 5 Figure A. 3: Where 'View Pro' can be found in LoggerNet.... 6 Figure A. 4: The data as seen in 'View Pro'.... 6 Figure B. 1: SAASim Harness wiring.... 7 Figure B. 2: SAASim Data Logger wiring.... 7 iv February 2015

SAA Simulator 1. Introduction Figure 1.1: SAASim. Measurand s SAA Simulator (SAASim) was designed and developed to provide a low cost accessory to verify Data Logger programs. The SAASim simulates one to many SAAs allowing customer program verification when physical SAAs are not available. SAASIM simulates models 1, 2, and 3 SAAs as well as magnetometers and Measurand PZs. It is not uncommon for the purchased SAAs to be in the field while the Data Logger or Earth Station are at the office waiting to be setup. The SAASim allows the Earth Station or Data Logger to be verified for the specific SAAs before going out to the field. 1.1 Description The SAASim comes with five 5-pin terminal blocks representing up to 5 SAAs. If more SAAs need to be simulated, then more simulators will be needed or more wires can be added to the SAASim wiring harness. When using an SAA232 or SAAFPU only one 5-pin terminal block is required. When using an SAA232-5, all 5-pin terminal blocks can be used at once. When there are several SAA232-5s for one setup then more SAASims or expanding the current SAASim will be required. Contact Measurand for further information on expanding the current SAASim. Measurand encourages the practice of labeling all SAA232s and SAA232-5 channels with the SAA Serial Numbers as they were setup in the Software. For further assistance with Measurand Applications and Utilities please review the SAA Software manual available on Measurand s website. February 2015 1

2. Using SAASim There are several related uses for the SAASim. Its primary function is to allow for the setup, testing and verification of LoggerNet and SAACR_FileGenerator. In turn, this allows for the testing of the auto recording and conversion. SAACR_DataChecker can be used to verify good data is received with the LoggerNet setup. The SAASim can also be used to practice using Measurand s Applications and Utilities without using real data. 2.1 SAACR_FileGenerator & LoggerNet Have the Earth Station connected to a PC. Plug an SAASim 5-pin terminal block into both SAA232s as shown. The SAASim will work with any setup available from Measurand. Figure 2.1: SAASim connected to two SAA232s in an Earth Station with a CR800 Logger. 1. Open SAACR_FileGenerator and create a file for the two SAAs. Check the COM ports, the Data Logger type (for this example: CR800). Physically label where the specific SAAs are setup to be read from so that in the field the appropriate SAA is connected to the appropriate SAA232. In the field, if the wrong SAA is connected to any of the SAA232s then no data will be recorded. If the SAAs are already installed then it is vital to know what SAA is where. 2 February 2015

SAA Simulator Figure 2.2: The SAA232 with SAA1 (Serial Number 67091) must be connected to COM Port 1 on this Earth Station while the SAA232 with SAA2 (Serial Number 62189) must be connected to COM Port 2 on this Earth Station. 2. Click Generate File, name the file and click OK. 3. Now continue to the SAACR_Raw2DataConfigurator tab. The SAAs from the previous screen are already inserted. Don t forget! The Data Logger Name entered here MUST be the same name given to this CR Data Logger in LoggerNet. (Step 4) Complete filling out the information and click Generate Config File. Figure 2.3: These settings are for Auto Conversion and can be changed. February 2015 3

4. Open LoggerNet. (For assistance see SAA Software Manual Section 4) Setup the CR Data Logger. Compile the Main Program created in SAACR_FileGenerator. Upload program files to the CR Data Logger. File Management. 5. Test data collection from the CR Data Logger. SAA Software Manual Section 4.2.1 6. Test the Automated Data Collection. SAA Software Manual Section 4.2.2 7. Setup and test Automated Data Conversion. SAA Software Manual Section 4.2.4 4 February 2015

SAA Simulator A. Troubleshooting Due to the SAASim s nature, if any issues arise they would be from the Hardware or Software setup. The SAASim is unable to provide bad or no data. To check that data is being captured by the Data Logger, the.dat file can be reviewed in either a spreadsheet program, SAACR_DataChecker (SAA Software Manual Appendix B) or LoggerNet s View Pro. In a spreadsheet, all of the column data for the SAA segments should be non-zero, except those segments that include magnetometer data. Figure A. 1: Opened as a comma delimited file. In SAACR_DataChecker, there should be colored columns, no black. If the SAA contains one or more magnetometers, make sure that the Hide Magnetometer Data checkbox is checked as the data from magnetometers typically contains some zero values. Figure A. 2: Can open several SAA.cal files at once. If there are zeros (or black lines) in the SAACR_DataChecker view, check the Hardware setup and then check the Software setup. In LoggerNet s View Pro, as in the spreadsheet, there should be no zeros for all segments without magnetometers. February 2015 5

Figure A. 3: Where 'View Pro' can be found in LoggerNet. Figure A. 4: The data as seen in 'View Pro'. 6 February 2015

SAA Simulator B. Wiring Diagrams Figure B. 1: SAASim Harness wiring. Figure B. 2: SAASim Data Logger wiring. February 2015 7

C. Support (Help) For support with Measurand products, please contact us: Measurand Inc. 2111 Hanwell Road Fredericton, New Brunswick Canada E3C 1M7 Phone: 506-462-9119 Fax: 506-462-9095 Website: www.measurand.com Email: saasupport@measurand.com C.1 Online Documents The following link goes to Measurand s website where Hardware and Software Manuals as well as Product Specifications can be downloaded. http://www.measurandgeotechnical.com/support_documents.html C.2 Online Tutorial Videos The following link goes to Measurand s website where training videos for software and hardware use and installation are available. http://www.measurandgeotechnical.com/support_tutorial_videos.html C.3 Online Software Downloads The following link goes to Measurand s website where SAASuite and other applications / utilities can be downloaded. http://www.measurandgeotechnical.com/software.html C.4 Sales Contact: Chris Gairns Email: SAASales@measurand.com 8 February 2015