Combustion Dynamics Instrumentation



Similar documents
9000 Series Accelerometers Specifications

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

and Accelerometers

Low Frequency Velocity Sensor

Vibration, Shock, and Acceleration

Model 601A02. Low-cost Industrial ICP Accelerometer. Installation and Operating Manual

Product Overview 9100D

A full spectrum of custom cables

ACCELEROMETER SELECTION CONSIDERATIONS Charge and ICP Integrated Circuit Piezoelectric

Velomitor Piezo-velocity Sensor

W-14 FAQ MACHINERY MONITORING

Echo Wireless Vibration Monitoring System

IMVIB. Online vibration monitoring for Ariel compressors

Proximity Transmitters and Seismic Vibration Transmitters

Acoustic Measurement Sensors & Instrumentation

Dynamic Pressure Charge Amplifier

On-line Machine Condition Monitoring [The CMS System]

VIBRATION SWITCHES SOLID STATE

Electronic Pressure Switch EDS 3000

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

The Do s and Don ts of Pressure Transducers

Troubleshooting accelerometer installations

NetScanner System. Toronto: , Montreal: , Toll Free: ,

WHITE PAPER. Driveshaft/Axle On-track Torque Measurement Continuous high speed torque measurements for vehicle performance testing.

PRODUCT CATALOG FTQ-200F SENSORS FOR LOAD, TORQUE, STRAIN, AND DYNAMIC FORCE

Intelligent Vibration Monitoring

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Torque Transducers MEASURING ELECTRONIC

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Transponder for GainMaker Amplifiers

How To Use A Detector 2

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Typical Aluminum GFM Mass Flow Meter

Top Technology for Industry, Agriculture, Business and Communities

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

Horns. Buzzers , Compressed air horns Disc-type horns Electric twin-tone horns 6.08

Product Information Sheet UH28CS-12kV Hi Pot Tester

Digital Controllers ACTUATOR COMPATABILITY

Rack mounted telephone- and leased line modem for industrial applications

MAJORSINE Power Inverter

Adjustment functions for both span and shift have been incorporated

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Micro Motion 3098 Gas Specific Gravity Meter

Heating oven with mechanical convection

Telephone- and leased line modem for industrial applications TD-36

Material test chamber with mechanical convection

Incubator with mechanical convection

SEMICONDUCTOR TECHNICAL DATA

ALARMLINE ANALOGUE Linear Heat Detection System

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Practical On-Line Vibration Monitoring for Papermachines

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Enhancing Business Performance using Integrated Visibility and Big Data

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

NEW. EVEN MORE data acquisition and test stand automation

Fiber Optic Distributed Temperature Sensor (B-DTS)

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

PRODUCT INFORMATION. Range of HUMS and Engine-monitoring Accelerometers Type , , 4523, 8345 and 8347-C.

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

PERF10 Rubidium Atomic Clock

Repeaters and Mimics Data Sheet

Product Data. Brüel & Kjær B. DeltaTron Range

4 Posiflow Proportional Solenoid Valves

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Process Alarm Solutions

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

Heating oven with mechanical control

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

TECHNICAL SPECIFICATION TYPE ATESO ALFA

Technical and Sales Information. Diesel Glow Plugs

Ultrasound Condition Monitoring

From process monitoring to vibration analysis

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Differential-Hall-Effect based Sensors Series A5S

Analog Servo Drive 25A8

Pressure transmitter For general industrial applications Model A-10

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Stainless Steel Dissolved Oxygen Electrodes

How To Power A Schen

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

SKF Machine Condition Transmitters (MCT) Series

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Transcription:

www.imi-sensors.com Combustion Dynamics Instrumentation For the Most Demanding Gas Turbine Measurement & Monitoring Requirements

IMI Sensors: A Leader in Combustion Measurement & Gas Turbine Monitoring For More Than 40 Years, PCB has specialized in the design and manufacture of innovative sensors and measurement systems for the gas turbine market. Spanning more than four decades, our expertise in combustion dynamics instrumentation has met the industry s most demanding requirements for dynamic combustion measurement and turbine engine monitoring. With the move toward increased fuel efficiency and lower exhaust emissions, today s gas turbine engines are based on technological innovation yet also bring potential problems. Burning a leaner flame keeps NOx emissions low but at the same time increases instability (combustion dynamics) in the gas turbine engine. This instability can damage components in the combustion chamber such as nozzles, baskets, and transition pieces, as well as downstream components such as blades, resulting in downtime and loss of revenue. IMI s instrumentation is designed to detect and measure dynamic pressure spikes, pulsations and surges in gas turbine engines. Our pressure sensors have three basic applications for detecting and measuring dynamic pressure phenomena and combustion instability in gas turbine engines: Remote Sensors Close Coupled Sensors On-Turbine Instability Sensors As the gas turbine industry has changed so has our technology. New lean burn and dry low NOx emission designs have made operating temperatures up to 1000 F a reality. IMI s instrumentation is ideally suited to detect and measure dynamic pressure for gas turbine engines in extreme heat environments. 2

Gas Turbine Combustor On-Turbine Instability Sensor Remote Sensor (located outside of turbine room) Close Coupled Sensor Infinite Coil Sensor Placement Diagram The diagram above shows a typical setting for a gas turbine in a power generation plant. Shown within the illustration are the three standard methods of measuring pressure; Remote, Close Coupled, and On-Turbine Instability Sensor (OTIS). The red bullets indicate the location of the actual sensor for each different method. 3

Remote Sensors These pressure sensors have either a portable or permanent configuration. Portable systems consist of pressure sensors that are connected to sensing lines running to some or all of the combustors. Similar to the portable systems, permanent systems provide sensors mounted outside the turbine enclosure. The sensors are then connected through sensing lines (tubing) to each combustor. Because of the long sensing lines involved, the ability to purge condensation is required. There are advantages to this simple, low-cost approach. Because the sensors are mounted outside the turbine enclosure, the conditions the sensors must endure are relatively mild, thus allowing for the use of less expensive sensors with longer life expectancy. In addition, these sensors can be serviced while the turbine is online. Sensor Enclosure Pressure Sensor (Series 102 or Series 121) Infinite Coil Tube Length approx. 10 m Series 102 +275 ºF / +135 ºC ICP Pressure Sensor Sensitivities from 10 to 100 mv/psi (1.45 to 14.5 mv/kpa) Measurement range 50 to 5000 psi 316 stainless steel diaphragm 3/8-24 UNF fitting 003CXX Cabling Low Noise, Teflon, Coaxial Cable 10-32 Coaxial Plug to BNC Plug Series 121 +250 ºF / +121 ºC ICP Pressure Sensor Sensitivities from 10 to 100 mv/psi (1.45 to 14.5 mv/kpa) Measurement range 50 to 500 psi 316 stainless steel diaphraghm 1/4 NPT fitting 052BRXXXAC Cabling Polyurethane, Twisted Pair Cable Composite 2-Socket MIL to BNC Plug 4

Close Coupled Sensors Close coupled sensors permanently mounted to a gas turbine are ideal for monitoring combustion dynamics (instability). Operating at a wider frequency range than remote sensors, the high sensitivity and higher-temperature capability of these sensors allow for precision measurement in turbine locations where the application of other instrumentation is not possible. Close coupling of the sensors to the combustor enables the measurement and detection of dynamic pressure phenomena such as high-frequency events that can cause damage to downstream components such as blades. Like the portable and permanent remote sensors, close coupled sensors also require a purging system to eliminate condensation. Infinite Coil Pressure Sensor (Series 171) Tube Length approx. 5 m Combustor Gas Turbine Series 171 +500 ºF / +260 ºC High Sensitivity Pressure Sensor Measurement range: 10 psi (68.9 kpa) Sensitivity: (±20%) 1100 pc/psi (160 pc/kpa) 2-pin connector, 1-1/8-12 UNF-2A port Weight: 6.5 oz (185 gm) Model 422E55/D +250 ºF / +121 ºC Slim In-Line Charge Amplifier Output voltage: (at specified measurement range) ±5 Vpk Sensitivity: (±2.5%) (charge conversion) 0.5 mv/pc Frequency range (±5%) 0.5 Hz to 100 khz Housing material: stainless steel 045ERXXXAC Cabling Low noise, Teflon, Twisted Pair Cable 2-Socket MIL to BNC Plug 5

On-Turbine Instability Sensor (OTIS) High-temperature sensors directly mounted to the combustor basket provide 24/7, consistent, reliable combustion dynamics data monitoring so that tuning changes can be made at anytime. On Turbine Instability Sensors allow for diagnostics, part fatigue analysis, and the ability to continuously monitor and control emissions. The higher frequency capability of the OTIS sensors enable the use of auto-tuning and on-line diagnostic monitoring systems. In addition, these sensors provide an output that can easily connect to legacy combustion dynamics monitoring systems. By having sensors directly mounted to the combustor, operators save time during combustion analysis. Charge Amplifier (Series 422M182) (located outside turbine room) 045M19 Cable to Charge Amplifier Enclosure Length approx. 10 m Series 176 High Temp Pressure Sensor Combustor Signal Sent to Control Room Inner Wall of Can Series 176 +986 ºF / +530 ºC High Temp Pressure Sensor Sensitivities to 17 pc/psi Measurement range 20 psi 045M19 Cabling Low noise, Teflon Cable, 2-socket 7/16 MIL to 2-Socket MIL-C-5015 Series 422M182 Charge Amplifier Sensitivity 4 mv/pc Frequency Ranges from 2 Hz to 30 khz 052BRXXXAC Cabling Polyurethane Cable, Composite 2-Socket MIL to BNC Plug Series 176 +986 ºF / +530 ºC High Temp Pressure Sensor Sensitivities to 17 pc/psi Measurement range 20 psi 045M19 Cabling Low noise, Teflon Cable, 2-socket 7/16 MIL to 2-Socket MIL-C-5015 Series 495B30 Differential Charge Amplifier Sensitivity 9 µa/pc Frequency ranges from 60 Hz to 10 khz 052ACXXXAD Polyurethane Cable, BNC Plug to Pig Tails Series 682A70 Galvanic Isolator Sensitivity 1 V/mA Frequency range from 0.16 6

High Temperature Accelerometers for Gas Turbine Monitoring Vibration monitoring of gas turbines can provide crucial information to diagnose potential problems, leading to an increase in uptime and a decrease in unplanned maintenance, catastrophic failures and accidents. Innovations in high temperature accelerometer technology for gas turbine monitoring now enable vibration measurement in extreme heat environments up to +1200 F (+649 C). IMI s high-temp accelerometers come in a variety of frequencies, temperature ranges, and configurations. Integral charge amplifiers allow for use with standard data acquisition equipment. Series HT62X +325 ºF / +163 ºC Model 622A01 ICP Accelerometer with High Temperature Range Option Sensitivity: (±5%) 100 mv/g (10.2 mv/(m/s²)) Frequency Range: (±3dB) 12 to 480000 cpm (0.2 to 8000 Hz) Measurement Range: ±50 g (±490 m/s²) Electrical Connector: 2-Pin MIL-C-5015 Series 612 +500 ºF / +260 ºC High Temperature Industrial Charge Accelerometer Sensitivity: (±10%) 26 pc/g (2.6 pc/(m/s²)) Temperature Range: (Operating) -65 to +500 F (-54 to +260 C) Electrical Connector: 2-Pin MIL-C-5015 Electrical Connection Position: Top IMI s high temperature accelerometers interface directly with handheld data collectors for both permanent mount and route based applications. Series 600A13 +900 ºF / +482 ºC Very High Temperature Accelerometer Kit Sensitivity: (±5%) 100.0 mv/g (10.2 mv/(m/s²)) Frequency Range: (±5%) 282 to 240000 cpm (4.7 to 4000 Hz) Measurement Range: (Peak) ±50 g (±490 m/s²) Mounting: Through Holes (3) Series 357C90 +1200 ºF / +649 ºC Charge Output Accelerometer, Integral 10-ft Hardline Cable Sensitivity: (±10%) 5 pc/g (.51 pc/(m/s²)) Measurement Range: ±1000 g pk (±9800 m/s² pk) Frequency Range: (±5%) 2.5 khz Electrical Connector: Integral Hardline Cable 7

About IMI Sensors IMI Sensors, a division of PCB Piezotronics, Inc., is dedicated to addressing the machinery vibration sensing needs for condition monitoring, predictive maintenance, and process control requirements. All IMI sensors and vibration switches are designed to withstand the rigors of harsh industrial environments. Included are sensors that interface directly with vibration data collectors and analysis equipment, as well as process monitoring equipment, PLC, DCS, alarm, and SCADA systems. For more information about IMI Sensors please call us anytime at 800-959-4464, or visit www.imi-sensors.com. PCB Piezotronics, Inc. is a global leader in the design and manufacture of force, torque, load, strain, pressure, acoustic and vibration sensors, as well as the pioneer of ICP technology. This instrumentation is used for test, measurement, monitoring, and feedback control requirements in automotive, aerospace, industrial, R&D, military, educational, commercial, and OEM applications. From ready-to-ship stock products, to custom-made specials, PCB proudly stands behind all products with services customers value most, including 24-hour customer support, a strategic global distribution network, and the industry s only commitment to Total Customer Satisfaction. For more information about PCB visit www.pcb.com. 3425 Walden Avenue, Depew, NY 14043-2495 USA Toll-Free in USA 800-959-4464 24-hour SensorLine SM 716-684-0003 Fax 716-684-3823 E-mail imi@pcb.com Web Site www.imi-sensors.com ISO 9001 CERTIFIED A2LA ACCREDITED to ISO 17025 2010 PCB Group, Inc. In the interest of constant product improvement, specifications are subject to change without notice. PCB, ICP, and IMI with associated logos are registered trademarks of PCB Group. SensorLine is a service mark of PCB Group. All other trademarks are property of their respective owners. IMI-GasTurbine-1110 Printed in U.S.A.