3" Real Time Quad Monitor with Camera System MODEL NO.: QSM-300 CTRAST BRIGHT VOLUME EXIT MENU AUTO PIP CH CH 3 CH POWER Complete Ready- to- use, Easy-to-manage, Commercialized Package Set. Real Time High Resolution Quad TINSE06---00 PRINTED IN CHINA
Specification Contents Monitor Power Input: DC V, A Picture Tube: 3 " diagonal 90D deflection Hi-Bias CRT. Resolution: 380 lines min. Band Width: 8Mhz+/-5db. Video Input: 0.5~.5v pp 75 ohm. Video Output: +/-0.3 v pp. Power Consumption: W(approx.)DCV in. Cable Connector: Pin DIN jack for cameras. AV Input/Output: RCA Jack Operation Temperature: -0 C ~ +50 C. Dimension: 330 x 300 x 30 mm. Unit Weight: 6. kgs Camera Pick-up Device: /3" CCD/CMOS image sensor. Picture Element: 50(H) x 9 (V) EIA. CCD 500(H) x 58 (V) CCIR. CCD 50(H) x 9 (V) EIA. CMOS 68(H) x 58 (V) CCIR. CMOS Horizontal Resolution: 350 lines Light Sensitivity: 0. LUX. Power Consumption:.W max for CCD 0.6W max for CMOS Operation Temperature: -0 ~ +50 C. Dimension: 8 x 8 x 03 mm. Unit Weight: 30 g. Location of Controls ~3. Installation / Connection ~5 3. Operation / Setting 6~. Specification
DC V IN V IN PUT A V A V-HOLD Front Location of controls Rear EXIT/PIP FUNCTI : There are three mode in PIP function. picture in picture 00 / /30 3:35:36 3. sequence picture in picture 00 / /30 3:35:36 0 9 8 7 6 5 3 Front : 3 5 6 7. Power Switch: Push the switch for power or OFF.. /up Switch: To select camera No. or as an UP function switch in manual setting mode. 3. /down Switch: To select camera No. or as a DOWN function switch in manual setting mode.. 5. 6. /right Switch: To select camera No.3 or as a RIGHT function switch in manual setting mode. /left Switch: To select camera No. or as a LEFT function switch in manual setting mode. Quad Function Switch: To select quad mode display... picture in picture 00 / /30 3:35:36 When press " EXIT/PIP " key once: The main picture is "" and the second picture is "". Press " EXIT/PIP " key again: and will appear on. ~ 3. Press" EXIT/PIP "key again: will get into "sequence picture in picture " model.the PIP screen will change between available channel and switch time will follow the swither time of auto function
3./right to increase second in switch time mode. Or set the skipped channel on../left to decrease second in switch time mode. Or set the skipped channel off. Alarm setup and video loss record: ALARM SETUP AUTO ADJUST AUTO SWITCHER TIME :05 SEC QUAD VIDEO LOSS RECORD Set to Position for any channel you would like to come with alarm function, then the monitor will alarm automatically for 30 seconds when there is video loss from any channel at position. It wil stop for 30 minutes when pushing only function key but will alarm again after that only unless you solve the "video loss " problem or reset that channel to "OFF" It will record the time and channel number of " video loss " and keep up to 0 records. ALARM CHANNEL INDICATOR VIDEO LOSS RECORD 00 /0 / 3:35:6 00 /0 / 3:35:6 00 /0 / 3:35:6 00 /0 / 3:35: 00 /0 / 3:35: 00 /0 / 3:35: 00 /0 / 3:35: 00 /0 / 3:35:36 00 /0 / 3:35:37 00 /0 / 3:35:6 PUSH (ERASE ),MENU (EXIT) KEY *The L3 indicate the active alarm channel, if the CH set to on position and without signal input, the channel no will be flash all the time. 7. 8. 9. 0... Rear: 3.. 5. 6. 7. Auto Function Switch: To select AUTO function display. Menu Function Switch: To get into the function setting mode. Exit/PIP Function Switch: To select Picture In Picture function in normal mode or QUIT function key in setting mode. Volume Control: To adjust the VOLUME level. Bright Control: To adjust the BRIGHT level. Contrast Control: To adjust CTRAST ratio of the picture. /// Input Jack: These input jacks receive video and audio signal from the cameras and supply the DC power to cameras. DC Input Jack: Connect to a V DC power supply or AC/DC adaptor. AV Input Jack: For input video and audio signal to the monitor. If you plug an RCA plug to this jack, then, the switch of the RCA will disconnect the camera signal automatically until you take off the RCA plug. AV Output Jack: Output the video and audio signal for VCR/DVR recording. V-Hold Control: If the picture rolls up or down, adjust the control to fix it 0 3
DC V IN IN PUT V A V A V-HOLD Monitor Unit Installation / Connection Use the provided cables to connect the cameras & monitor shown as below, install the plug of the AC/DC Adaptor to the DC jack of the unit, plug the adaptor into a standard wall outlet.. Press the /up key or /dowm key to move the cursor up or down.. Press the /right or /left to move the cursor right or left. BRIGHT ADJUST - -3 - - 0 + + + 3+ 3 Camera Unit Attach the camera onto the pedestal using the screw provided and tighten using a screwdriver. Tighten the thumb screw when the desired camera angle attained. Time/date adjust: To set the correct time refer to the local time and date. Press:./UP key to increase the number of time/date../down key to decrease number of time/date 3./RIGHT to move the cursor to right direction../left to move the cursor to left direction. Auto adjust: To adjust the auto switcher time from -60 second and to set the camera skipped for auto sequence switcher. Press:./UP to move the cursor up../down to move the cursor down. 9
Contrast adjust: DATE TIME DISPLAY MODE To adjust contrast level of each camera, better all at the same level..press the /UP key or /DOWN key to move the cursor up or down.. Press the /RIGHTor /LEFT to move the cursor right or left. Audio/Video output for recording: The Video and Audio output jacks can be connectted to the RCA type of A/V input jacks on your VCR or DVR for recording Audio/Video input for display: Plug A/V signal from VCR or other signal source into the monitor with RCA type cable. The switch of RCA jack will disconnect the signals from cameras automatically, until you take off the RCA plug VCR REAR VIEW OF MITOR V-HOLD INPUT DC VIDEO AUDIO VIDEO AUDIO V IN CTRAST ADJUST - -3 - - 0 + + + 3+ INPUT AUDIO VIDEO AUDIO VIDEO Bright adjust: To adjust bright level of each camera, better all at the same level 8 5
. Operation /Setting POWER SWITCH: Push the switch to turn on the monitor..- keys: Use ~ to get any single camera in full screen display from ~. 3.QUAD key: Use the QUAD to get quad display..auto key: Use the AUTO to get Auto switching function from QUAD---- except there is any channel set to OFF in SKIP mode or no camera signal input. 5.MENU key: Use the MENU to get into the setting mode, the setting manual will appear on the screen as bleow * Use /up or /down key to select item -7,then press MENU again to get into the item when the hand-marker stops at that item. Press MENU key and then EXIT/PIP key to quit. Camera title: You can rename the camera title, as you want. the factory setting is -..Press /UP key can move the cursor from left to right..press /DOWN key can move the cursor from up to lower position. 3.Press /RIGHT or /LEFT key to select each character of camera name. CAMERA TITLE SYSTEM SETUP.CAMERA TITLE.DISPLAY MODE 3.CTRAST ADJUST.BRIGHTNESS ADJUST 5.TIME/DATE ADJUST 6.AUTO ADJUST 7.ALARM SETUP Display mode: To set date/time and each camera title of - ``on or `` off..press the /up key and /down key to move the hand-marker up or down.. Press the or to set ``on or `` off. 6 7