FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS



Similar documents
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

Notes. Material 1. Appropriate Flammable Liquids

RISK MANAGEMENT QUARTERLY BUILDING REPORT Fire Safety Self -Inspection Checklist

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

General Fire Code Requirements Within Commercial Tenant Spaces

FIRE SAFETY ONLINE TRAINING

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Flammable and Combustible Liquids. Slide 1 (of 23)

Spray Booth Guideline

Sample Written Program. For. Flammable Liquids

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Winnipeg Fire Department Fire Prevention Branch

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

ADMINISTRATIVE SERVICES MANUAL

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

An inventory of hazardous materials used in your workplace will prove useful.

Laboratory Safety and Environmental Health Assessment Program

SAFETY SELF-INSPECTION PROGRAM

Name Of Occupancy Date. Yes No Describe

Safety and Health Office WORKPLACE SAFETY CHECKLIST

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

Texas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08)

Errata has been identified as follows:

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Fire Safety Requirements for Child Care Centre

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Important Ontario Fire Code Information for Building Owners in the City of Windsor

FLA S FIRE SAFETY INITIATIVE

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

Town of Bellingham Fire Department

Quality Assurance Calendar Maintenance Responsible Party Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

FIRE RISK ASSESSMENT

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Overview of Hotel Fire Safety Requirements

Commercial Fire Inspections

HOT WORK PERMIT PROGRAM TRAINING. John Braun

A. Fire Protection Plan. B. Access and Parking

Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment)

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Fire Prevention Plan for Flynn Hall 1648 Musketeer Drive

For use by landlords of small premises Premises Address

Emergency Evacuation Plan: 232 King St.

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

CANTON FIRE DEPARTMENT

Course of Construction Questionnaire

Fire Safety Log Book

Table of Contents CHAPTER 11 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR CHILD CARE CENTERS

EXAMPLE EMERGENCY ACTION PLAN FOR SMALL BUSINESSES

OSHA Office of Training and Education 1

Monthly Inspection Checklists

UNIVERSITY OF TOLEDO

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):

Fire Prevention Plan for Commons 1655 Musketeer Drive

TCC Fire Regulations Exhibits & Displays in Public Buildings

Flammable Liquids 29 CFR

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

Disaster Prevention and Protection Checklist

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Commercial Kitchen Fire Safety

How To Write A Fire Risk Assessment

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Safety Inspections and Sample Safety Inspection Checklists

How To Check If A Building Is Safe For A Disabled Person

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

FLORIDA A&M UNIVERSITY FIRE SAFETY AND EMERGENCY GUIDELINES FOR RESIDENT ADVISORS AND RESIDENT ASSISTANTS

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rules

FIRE RISK ASSESSMENT. The Workplace Fire Precautions Legislation

FIRE SAFETY HANDBOOK

Fire Safety Risk Assessment Checklist for Residential Care Premises

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Health Care Facilities

CHILD CARE CENTER INFORMATION SHEET

Environment of Care Fire Safety Management Plan 2014

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

St. John s University

Automatic fire-extinguishing systems for commercial cooking

FIRE SAFETY PLAN FOR SMALL ASSEMBLY FACILITIES

NORTH BIRMINGHAM ACADEMY

Restaurant & café guide

Minnesota State Department of Public Safety

Fire Safety PROCEDURES January 2011

TOWN OF DAVIE BUSINESS TAX RECEIPT 6591 ORANGE DRIVE DAVIE, FLORIDA PHONE: FAX:

For use by landlords of small premises Premises Address

The terms hazard and risk are often used, which we define as the following:

STCC Contractor/Vendor Rules and Regulations

SCHOOL SELF-INSPECTION FORM

Orange County Fire Rescue Division Fire Loss Management Bureau 109 East Church Street Lower Level Orlando, Florida

Fire Safety In High Rise Building

Transcription:

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS The attached self-inspection form is intended for staff use at regular, frequent intervals. It should not take the place of two other vital measures - the thorough, objective, periodic inspection of the cultural institution by municipal fire inspectors or by fire safety specialists, and the regular inspection, testing and maintenance of fire detection and extinguishing installations by specialists. Cultural institutions vary widely in character. t all of the points to be inspected apply in every case. By striking out those that obviously do not fit local circumstances, a cultural institution can tailor this form to its specific needs. These self-inspections should do more than disclose conditions of negligence that could be the source of fire or that might result in greater damage and, possibly, loss of life in the event of fire. The primary purpose is to secure the correction of these conditions. Therefore it is imperative that all questions answered be referred to the responsible department or staff member. Then it becomes an important function of management to make sure that corrective action has been taken.

General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency lighting system operable and tested weekly? are corridors and stairways unobstructed? are fire exits unlocked and unobstructed? is safe egress uncompromised by security measures? are self-closing fire doors unobstructed and properly equipped with closing devices? are no smoking regulations strictly enforced? is housekeeping properly maintained? are cleaning supplies safely stored? are supply closets and slop sink areas clean and orderly? do temporary wiring and lighting conform to NFPA 70, National Electrical Code? do all electrical components bear the label of a testing laboratory? are electric hot plates, coffee makers and space heaters prohibited or limited to those with an appropriate automatic shut-off bearing the label of a testing laboratory? do electrical appliances have warning lights? are appliances unplugged when not in use? is rubbish removed from the building daily? is rubbish stored away from the building in closed metal containers? are stocks of flammable liquids stored away from the building? are sufficient fire extinguishers present? are extinguishers of the proper type? (See NFPA 10, Portable Fire Extinguishers.) are extinguishers properly hung and labeled?

are extinguishers properly charged and tagged with inspection tags? are sprinklers unobstructed and at least 18 in. above top of storage? are standpipe hose outlets properly marked and unobstructed? are sprinkler control valves properly labeled and unobstructed? are recorded weekly inspections made of all sprinkler control valves to make certain they are open? are dry-pipe valves (for sprinklers in areas exposed to freezing) in service, with air pressure normal? are all fire-detection and fire-suppression systems in service and tested regularly? Special Area Inspection 1. Exhibit Areas, Reading Rooms, and Study Carrels: is proper salvage equipment to protect the catalogue ready for use? are exhibit housings, partitions, platforms, and other supports of noncombustible or fire retardant materials? have exhibit installations kept fire hose outlet valves and fire alarms unobstructed and visible? Yes 2. Collections Storage Areas (book stacks, museum collections, etc.): are these areas separated by appropriate fire walls and fire doors from other occupancies? have all vertical and horizontal openings in fire barriers been adequately fire stopped? is proper salvage equipment ready for use? is first aid fire extinguishing augmented by an early warning automatic fire detection system? do fire alarms go directly to a 24/7 central monitoring station? does fire service have access to these areas? are collections protected by appropriate automatic extinguishing systems? 3. Conservation Laboratories, Restoration Shops, and Bookbinding: are flammable solvents and other chemicals properly labeled and stored in small quantities in safety storage cabinets? are flammable liquids dispensed from safety cans? are self-closing safety waste disposal receptacles available at work stations? are laboratory wastes disposed of daily with appropriate special precautions? are spray coating facilities adequately and safely ventilated? is electrical equipment in the spray area explosionproof? does the spray area have automatic fire extinguishing equipment? are employees aware of special hazards and trained in necessary precautions? is fire suppressant and personnel safety equipment appropriate for the special hazards that may be present? is entry limited to authorized persons?

4. Other Shops and Packing/Unpacking Areas: are paints, thinners, cleaning solvents and other flammable liquids properly stored in reasonable quantities in ventilated safety cabinets? are thinners and solvents dispensed from safety cans? are self-closing waste receptacles used for oily rags and other wastes liable to spontaneous heating? are flammable packing materials stored in self-closing safety containers? are power tools and machines properly grounded? do woodworking machines have proper dust collectors? are dust collector bins emptied regularly? do paint spraying facilities comply with local codes? does welding equipment meet local codes? are power tools unplugged when not in use? 5. Auditoriums and Classrooms: is safe capacity posted? is occupancy restricted to the capacity posted as safe? are standing and sitting in aisles prohibited? do furnishings and wall coverings comply with fire safety standards? does projection room meet local codes? 6. Food Services: is capacity posted? *are ranges, hoods and exhaust ducts cleaned? do exhaust ducts terminate in a safe area? are grease ducts and deep fryers equipped with automatic fire detectors and extinguishing systems? if below ground level, is area sprinklered? *te date when ranges, hoods and exhaust ducts were last cleaned. Exterior Inspection 1. Evacuation: do all exits, emergency exits, and fire escapes allow unobstructed passage to safe areas? 2. Environment: are grounds clear of accumulations of flammable material? have neighboring occupancies minimized exterior fire hazards? Yes

Yes is fire service access clear? are standpipe and sprinkler systems, siamese connections unobstructed and operable? are hydrants unobstructed? Personnel Inspection 1. Training: do all staff members know how to transmit a fire alarm? do all staff members know their assigned duty in evacuating the building? do all staff members know how and when to use portable fire extinguishers? do all staff members know their responsibilities in fire prevention? 2. Organization: has someone been designated as the facility fire protection manager? does the fire protection manager have an adequate training program in operation for himself/herself and the staff? is the written fire emergency plan up to date and properly distributed? has the fire service planned or trained for: protecting the cultural institution since the previous inspection? emergency operations (e.g., salvage, reports to authorities and news media)? te date of latest fire drill. Special Comments: Inspection made by: Title: Report reviewed by: Title: Corrective Action: Item Referred to Corrective actions completed: