During a one-month period, a NASA



Similar documents
Zinc Whisker Contamination

ARE ZINC WHISKERS GROWING IN YOUR COMPUTER ROOM?

Data Center and Computer Room Services Specialty Services Data Center and Computer Room Products Sub-Floor Cleaning

Metal Whisker Discussion (Tin and Zinc Whiskers)

The Continuing Dangers of Tin Whiskers and Attempts to Control Them with Conformal Coating

How To Clean A Data Center

APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details)

How to Meet 24 by Forever Cooling Demands of your Data Center

MOLD REMEDIATION KEY STEPS

Re-examining the Suitability of the Raised Floor for Data Center Applications

CONTROL METHODS. There are five ways to control the release of asbestos fibers:

Server Chassis and Triplet Hardware v1.0

Mount Sinai Pediatric Environmental Health Specialty Unit WTC Asbestos Fact Sheet

Mould Mould A Basic Guide

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Asbestos WHAT TO DO? Studies of people who were exposed to high levels of asbestos in factories and shipyards, are at increased risk of:

ATS Overhead Table Shelf System INSTRUCTION MANUAL

An Informational Pamphlet. 416 South East Street Lebanon, OH 45036

Asbestos Management Program

HP Data Center Services

Technical Data Sheet

Senior Network Administrator Page 2

Guidelines for Mold Remediation (Removal)

British Columbia Institute of Technology. BCIT Safety Manual ASBESTOS MANAGEMENT

Airborne asbestos is a serious health hazard.

Data Centre and Server Room Technical Cleaning

DiscPlus DX195 and DX225 Air Disc Brakes

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

UI Procedures for Asbestos Management

Georgia Tech Aerospace Server French building Server Room. Server Room Policy Handbook: Scope, Processes and Procedure

ASBESTOS CONTROL PLAN

Asbestos Work Permit Procedures

Compaq Rack Options and Accessories. Monitors and Keyboards

Asbestos in Your Home

Packaged Terminal Air Conditioner Wall Sleeve Installation

University of Pittsburgh Safety Manual. EH&S Guideline Number: ASBESTOS

The purpose of this document is to provide guidance on the safe removal and disposal of asbestos and asbestos-containing materials.

Data Centers and Mission Critical Facilities Operations Procedures

Power and Cooling for Ultra-High Density Racks and Blade Servers

TecCrete. Data Center Flooring

Asbestos Hazards and Controls

ASBESTOS MANAGEMENT PROGRAM

Cable management for rack-mounted systems

MOLD FAQs. 1. What is mold and where does it live? 2. How can mold affect my health?

NORMI Professional Guidance for DIY Projects

Modular Access Floor for Data Center. From Rack to Row to Room to Building

INDUSTRIAL ROOFING CASE STUDY: The Advantages of Aluminized Stainless Steel. Roof Installed:

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

Eco-Friendly Homes Presentation Asbestos, Mold, and Lead-Based Paint

Installation Instructions for Alarm Module Kit A043F059

Access Server Rack Cabinet Compatibility Guide

Cable Trays Technical Instructions & Specifications

How To Care For Asbestos

IWU PHYSICAL PLANT SAFETY PROGRAM. Toxic and Hazardous Substances, Title 29 Code of Federal Regulations (CFR) Part , Subpart Z Asbestos

IMPORTANT SAFETY RULES TO FOLLOW

Cabinets 101: Configuring A Network Or Server Cabinet

Asbestos Management. 2. Introduction. Contents

Mold Response and Remediation Plan

Installation Instructions

Excerpts from EPA s Mold Remediation in Schools and Commercial Buildings

Mold Management Plan Operations & Maintenance

MOLD RESPONSE AND REMEDIATION PLAN

UBC Plant Operations Asbestos Work Procedures April 2004

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

DATA CENTRES UNDERSTANDING THE ISSUES TECHNICAL ARTICLE

City of Philadelphia Mold Remediation, Water Damage and Use of Biocides

Lead Exposure Management Plan

Colonnade Security Pipe

Fully Managed IT Support. Proactive Maintenance. Disaster Recovery. Remote Support. Service Desk. Call Centre. Fully Managed Services Guide July 2007

Spetec Laminar Flow Systems. Operating Instructions

Stachybotrys chartarum a mold that may be found in water-damaged homes

Mobile Data Power Model: MDP-25

Fact Sheet on Asbestos

Mechanical Systems Competency 1.20

August Toronto Catholic District School Board Catholic Education Centre 80 Sheppard Avenue East North York, Ontario M2N 6E8

Wire Rope Extender Lanyard

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Aluminum versus Copper Conductors

DCA Data Centre Anti-Contamination Guide V1.3

Technology Corporation

Tyan Computer. Transport PX22. Service Engineer s Manual

Guidelines for Cleaning Staff on Managing Mould Growth in State Buildings

DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION

GeekDesk Max Instructions for Assembly & Use

File: Spill Response Plan for Hazard Chemicals and Mercury Spills. Orig. Date: 12/01/2005 Review Date: January Review Date: March 2010

DEFECTS IN SHEET ROOFING THAT IMITATES ROOF TILES AS A RESULT OF THEIR ANCHORAGE

Arbor Heights Indoor Air Quality Investigation Interim Report

Mold Questions and Answers Questions and Answers on Stachybotrys chartarum and other molds

Fungal Assessment. Smith Recreation Community Centre 1019 Hwy 2A, Smith, Alberta

Rack Hygiene. Data Center White Paper. Executive Summary

The art of the possible.

STANDARD OPERATING PROCEDURES FOR MOLD REMEDIATION

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

University of Nevada, Reno Facilities Services Department STANDARD OPERATING PROCEDURE. Facilities Maintenance Services

SECTION HEAT PUMPS

HP UPS R1500 Generation 3

Select Radiators Installation Guide

ASBESTOS AWARENESS IN THE WORKPLACE. This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation.

Transcription:

Are unexplained short circuits plaguing electronic equipment? If it s operating in a raised-floor data center, zinc whiskers growing from the floor tiles could be the cause. Jay Brusse and Michael Sampson Zinc Whiskers: Hidden Cause of Equipment Failure During a one-month period, a NASA data center experienced at least 18 catastrophic power supply failures in newly installed mass memory storage devices. The ensuing failure investigation determined that the causes of failure were electrical short circuits. But what had prompted such repeated short circuits in modern, typically reliable systems? The investigation concluded that for many years small metallic filaments, practically invisible to the unaided eye, had been growing from the underside of the raised floor tiles and floor support structures. Maintenance activity to install the new equipment dislodged many of these conductive filaments, which were then distributed throughout the data center by the forcedair cooling systems. Many of these particles were drawn into the equipment power supplies, where they bridged exposed conductors, causing electrical failures. Only then did the data center managers become acquainted with the phenomenon scientists call zinc whiskers. If you manage a data center, especially one that sits on a raised floor, zinc whiskers might eventually have an impact on your operations. Inside Resources Potential Health Hazards? WHAT ARE ZINC WHISKERS? Zinc whiskers, as the name implies, are tiny hair-like filaments of zinc that actually grow from certain zinc-coated metal surfaces. Figure 1 shows zinc whiskers, which are typically less than a few millimeters long and only a few thousandths of a millimeter wide. Because of their miniscule dimensions, zinc whiskers can be extremely difficult to see without magnification and proper illumination. The whisker formation process consists of an unpredictable incubation period typically lasting months or even years without any growth at all followed by a period of growth at rates as high as 1 mm/year. Many zinc-coated surfaces may never grow whiskers. Unfortunately, accelerated techniques do not currently exist to predict if, when, and to what extent a zinc-coated surface will produce zinc whiskers. Despite the first identification of zinc whiskers in the 1940s, their precise growth mechanism remains unknown today. In the decades since, research aimed specifically at the zinc whisker phenomenon has been limited. However, during this same time, researchers have written more than 100 reports or studies about tin whisker formation, a process that many agree is closely related to the zinc whisker phenomenon. Even with the large effort to study tin whiskers, identification of their growth mechanism(s) has also remained elusive. The NASA Goddard Tin Whisker (and Other Metal Whisker) Web site (http://nepp.nasa.gov/whisker) lists many of the available reference materials on the subject of tin and zinc whisker formation. 1520-9202/04/$20.00 2004 IEEE Published by the IEEE Computer Society November December 2004 IT Pro 43

DATA CENTERS hardware (such as nuts, bolts, washers, equipment racks, housings, and rails). Recently, however, the most frequently reported source appears to be the zinc-plated underside of the raised-access floor tiles and the support structures (pedestals and stringers) commonly used in computer data centers. Figure 2 shows a typical raised-access floor system. Raised-floor tiles, pedestals, and stringers are often constructed from steel to provide adequate strength.a thin zinc coating from electroplating or hot dip galvanization (HDG) is commonly applied to protect the steel from corrosion. This thin zinc film is at risk for forming zinc whiskers over time. Figure 2b shows one type of access floor tile known to form zinc whiskers. Figure 3 shows the tile s underside; a high-intensity light held parallel to the surface reveals what appear to be fuzzy dust-like formations. Closer examination reveals that the dust-like appearance is actually millions of zinc whiskers shown magnified in Figure 1. Many of these whiskers are 1 mm or more in length. Investigators have reported many cases of zinc whiskers growing on zinc-electroplated structures, and some report that HDG coatings are WHERE DO ZINC WHISKERS GROW? Zinc whisker growth has been documented on a wide immune to the whisker phenomenon. However, we have range of zinc-coated materials including electrical com- recently seen one report citing evidence of zinc whiskers ponents (such as electromagnetic relays) and mechanical (some as long as 0.3 mm after one year in service) growing on floor tiles and support structures that the manufacturer advertised as HDG. So we recfigure 2. Typical raised-access floor system. ommend caution when using any zinc coating in applications where zinc whiskers could pose a hazard. In the case of the NASA data center, investigators observed whisker densities on the order of millions per single floor tile (each with an area of 4 square feet). At the time of the equipment failures, these zinc-electroplated floor tiles were approximately 10 years old. Zinc whiskers on the under(b) (a) side of raised-floor structures might seem to be a long disa data center floor system with one tile up, permitting a view of the supporttance from electronic systems ing pedestals and stringers; such a raised-floor arrangement facilitates underthat operate above the floor. floor cable routing. The subfloor space also serves as an air plenum (a). In this However, the NASA review top and side view of one type of floor tile (b), cutting a tile reveals a vinyl top determined that routine mainsurface attached to a 1 inch thick wood fiber core. The core has a thin sheet of tenance activities in the data zinc-electroplated steel attached to its bottom and sides. center including the lifting, sliding, and reinstalling of access Figure 1. Zinc whiskers (here, magnified 100 ) growing on the underside of a raised-access floor tile. 44 IT Pro November December 2004

floor tiles and the pulling of electrical cable in the subfloor space could dislodge whiskers. Because of a whisker s small size and weight, the subfloor, forced-air cooling system can easily redistribute whiskers throughout the facility. For efficient cooling, the forced-air system typically pressurizes the subfloor space with chilled air. Perforated floor tiles and air vents provide channels through which the cool air and along with it, zinc whiskers can pass into the above-floor space. Ultimately, many whiskers can pass into the electronic hardware through vents and fans on the equipment. Once inside the equipment, zinc whiskers can cause various electrical failures, ranging from intermittent to permanent short circuits. Whisker debris can also become a physical impediment to moving parts or obscure optical surfaces and sensors within some equipment (such as disk or tape drives). Figure 4 shows a graphical representation of this zinc whisker failure mechanism. Figure 3. Underside of the zincelectroplated-steel floor tile in Figure 2b. The sparkling dust-like surface is actually millions of zinc whiskers shown magnified in Figure 1. WHEN TO SUSPECT A ZINC WHISKER ATTACK A review of the published literature and discussions with several other affected organizations have revealed the following common attributes of most zinc-whisker-caused failures in data centers: Inexplicable system failures began concurrent with (or within weeks of) maintenance activities requiring the handling of or impacts to floor tiles. Power supply failures are the most obvious because of the impact they have on system operation. However, failures of other electronic systems (logic cards, motherboards, memory devices, and so on) can also occur with less obvious but potentially serious effects. Newer equipment seems to be more susceptible to failure than older equipment. Equipment located adjacent to floor vents seems more susceptible to failure. Users might not thoroughly investigate periodic or intermittent system failures unless permanent hardware failures begin to occur or substantial system downtime occurs. Invoking service contracts and warranties sometimes means that problem investigation stops as soon as the vendor supplies replacement equipment. Figure 4. Zinc whisker failure mechanism in a raised floor setting. 4 Whisker debris distributed throughout data center (through perforated tiles or vents) Dimensions are not to scale 2 Air flow 5 Bumping or sliding floor structures can dislodge whiskers 1 Whisker debris drawn into equipment causes short circuits 3 Whiskers grow beneath floor from zinc-plated structures (tiles, pedestals, and stringers) Forced-air system recirculates whisker debris November December 2004 IT Pro 45

DATA CENTERS 46 IT Pro November December 2004 Resources Are Zinc Whiskers Growing in Your Computer Room? R. Hill, Data Clean Corp.; http://www.dataclean.com/pdf/ zincwhiskers3.pdf. Testing Your Mettle: Zinc Whiskers in the Data Center, B. Brown, Network World, Nov. 2004, http://www. nwfusion.com/news/2004/110104widernetwhiskers.html Pesky Whiskers Zap PCs in Secretary of State s Office, Aldo Svaldi, The Denver Post, 1 July 2004, pp. C-01. Precautions Against Zinc Whiskers, Compaq Corp., Power Requirements for Non-Stop Himalaya Servers 429905-001, http://h71033.www7.hp.com/techpubs/pdf/power_ Requirements/TPSEC05.pdf. What Nasty Little Things Are Lurking Inside Your Data Center? S. Tucker, Unisys World Monthly, Nov. 2002; http://www.unisysworld.com/monthly/2002/11/whiskers. shtml. Zinc Whisker Abatement, Worldwide Environmental Services; http://www.wes.net/field_engineering_services-zinc_ whisker_detail.htm. Zinc Whiskers: Could Zinc Whiskers Be Impacting Your Electronics? J. Brusse, Apr. 2003; http:// nepp.nasa.gov/ whisker/reference/tech_papers/brusse2003-zinc-whisker- Awareness.pdf. Zinc Whisker Contamination: A Paper on the Effect and Abatement of Zinc Whiskers in Data Processing Centers, D. Loman, HP Services; http://www.dataclean.com/pdf/ ZincWhiskerWhitePaper.pdf. Zinc Whiskers Growing on Raised Floor Tiles are Causing Conductive Contamination Failures and Equipment Shutdowns, The Uptime Institute; http://www.upsite.com/ TUIpages/tuiflashzinc.html. Zinc Whiskers on Floor Tiles, Infinite Access Floors; http://www.accessfloors.com.au/zincwhiskers.htm. Zinc Whisker Induced Failures in Electronic Systems, ERA Technology, Winter 2003, http://www.era.co.uk/ news/rfa_feature_06.asp. Whisker Alert, Japan Electronics & Information Technology Industries Association (JEITA), Jan. 2002; http:// it.jeita.or.jp/infosys/info/whisker/ (in Japanese). Failure investigations (and corrective action) frequently consider electrical power spikes or inadequate cooling as the problem sources before identifying zinc whiskers as a suspect. Techniques for investigating these other causes might involve significant handling of floor tiles and can actually generate additional whisker-induced problems. Most data center managers have never heard of zinc whiskers until the problem affects their systems. CAUSES FOR RENEWED INTEREST During the course of this problem investigation, engineers supporting NASA Goddard Space Flight Center learned that numerous organizations (financial, engineering, educational, governmental, and so on) have experienced problems with zinc whiskers, as the Resources sidebar indicates. Several factors appear to contribute to the apparent increase in reported failures: Continuous miniaturization of electronic components. Technological advances have led to more densely packed circuitry and tighter spacing between conductors. As a result, smaller conductive particles can now cause short circuits. Reduction in circuit voltages and currents. Many newer electronic systems operate at lower voltages and currents. Energy available from these components might not be sufficient to melt a zinc whisker, resulting in increased risk for permanent shorts. Age of existing floor structures. Many facilities have zinc-electroplated floor structures that are 10,20,or 30 years old or more.thus,where zinc-electroplated floor structures are in use, whiskers have had time to grow to lengths capable of bridging exposed conductor spacings in most modern electronic systems. Increased maintenance and upgrade activity in raised-floor facilities. Any activity in the raised-floor facility that involves handling or moving floor structures can potentially dislodge zinc whiskers, if the structures are already infested with these growths. In today s high-technology environment, it is more commonplace for computing facilities to undergo regular maintenance activity to perform tasks such as adding or removing hardware; repositioning or reconfiguring the equipment; or general troubleshooting. Other concerns, such as those we discuss in the Potential Health Hazards? sidebar could also become a problem. REMEDIATION The affected NASA data center implemented some short-term corrective actions while evaluating long-term solutions to its zinc whisker problem. The short-term corrective actions included replacing the affected power supplies; the new power supplies came with a protective insulating compound that coats most of the exposed electronic circuitry. This coating will minimize (not necessar-

ily prevent) the risk of future power supply short circuits from zinc whisker debris. The affected data center also reduced activities that require the significant handling of floor tiles. For long-term solutions, NASA is evaluating proposals from industry professionals that include, but are not limited to the carefully planned and controlled removal of all affected or suspicious tiles and support structures, while protecting equipment and personnel; thorough cleaning of the data center environment, using vacuums with HEPA (highefficiency particulate air) filters to remove as much whisker debris as possible; and the installation of replacement floor structures that are not prone to zinc whisker formation, including all-aluminum or steel structures with conductive epoxy powder coatings or paints instead of zinc for corrosion protection. Simply washing whisker-infested materials is not an effective long-term remedy.whiskers can grow back.and though cleaning and then coating whisker-prone surfaces might work, whiskers could possibly grow through some conformal coatings, depending on their properties and thicknesses. Long term testing is certainly needed to validate such remediation approaches. Data center managers should take zinc whisker identification, detection, and mitigation seriously. Improper procedures could produce additional hazards and failures. Rather than attempt to conduct these activities alone, organizations at risk for zinc-whisker-related problems should seek expert advice. Possible information sources include the suppliers of electronic hardware; the original supplier of the floor structures; professional data center cleaning or disaster recovery companies; and professionals in medicine, or occupational health and safety. We encourage data center managers to review equipment maintenance records as well as the equipment selfdiagnostic fault logs for abnormally high failure rates. Such trends, especially if concurrent with floor-handling activities, could indicate an active zinc whisker problem. Unfortunately, this zinc whisker failure mechanism appears to be quite widespread, while awareness by facility or data center management personnel appears to be rather limited. We hope this report will help other organizations to identify a potentially serious hazard before they experience problems. Potential Health Hazards? Our investigation of the NASA data center raised concerns about potential health hazards from zinc whisker exposure. NASA is still reviewing this issue, but our initial research did not identify any specific studies or published guidance. Several sources discuss the toxicity of zinc in other forms, particularly zinc oxide in the form of granules, powder, fumes, and dust. In these forms, zinc seems generally benign when inhaled or swallowed, except in very high concentrations. Inhalation of zinc fumes can have more serious effects. Various informal reports on zinc whiskers suggest no health implications from exposure; however, these reports lack cited references from medical or occupational-health professionals. Other research suggests that the shape of airborne fibers can be an important factor regarding the potential pathologic effects on the lung, specifically a length-to-width ratio of 100 to 1 or greater. Zinc whiskers commonly exceed this ratio. Michael Sampson is the manager of the NASA Electronic Parts and Packaging Program. Contact him at michael.j. sampson@nasa.gov. For further information on this or any other computing topic, visit our Digital Library at http://www.computer. org/publications/dlib. We acknowledge the NASA EEE Parts Assurance Group (NEPAG) for its support in investigating tin and zinc metal whisker formations. We also thank Henning Leidecker (NASA Goddard) and Jong Kadesch (Orbital Sciences Corp.) for their invaluable participation on our metal whisker investigation team at the NASA Goddard Space Flight Center. Jay Brusse is a senior components engineer at QSS Group Inc. in Greenbelt, Maryland. Contact him at jay.a.brusse.1@ gsfc.nasa.gov. November December 2005 IT Pro 47