Inspection Report Atlanta Strip Mall Commercial Building Property Address:



Similar documents
Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066

Inspection Report. Mr. Happy 2 flat owner. Property Address: Focal Point Home Inspection Ltd.

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL South East Building Consultants

Vision Home Inspection

Inspection Report. Mr. JOHN SMITH. Property Address: S. Main St Denver Co A Happy House Home Inspection, LLC

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN USA Drive. Morris Home Inspection Group, LLC

Home Inspection Report

PROPERTY INSPECTION REPORT

Crawford Inspection Services C.C.B. #

Inspecton Report. Property Address:

South Carolina Home Inspector Standards of Practice

Inspection Report TPCC. Property Address: 22 Touisset Road Warren RI Lane's Perfection Inspections

COMPREHENSIVE PROPERTY INSPECTIONS

Inspection Report. Property Address: St. Marks Ave. Brooklyn NY Five Borough Home Inspection, LLC. Derek Lomer

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

October 5, 2015 Dear Client,

Inspection Report. sample sample. Property Address: 333 Wild Rasberry Lane. Etowah NC. Hubert Lowe Home Inspections

Inspection Tech. (330) Inspected By: Aaron Westerburg

HOME INSPECTION REPORT

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Home Inspection Report

License Requirements for Persons Engaging in the Business of Inspection Practice:

Inspection Report. Sample Client. Property Address: XXXX N. Atolia Drive Tucson AZ House and Home

Vari Inspection Services

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)

Summary of Oregon Home Inspector Certification Law and Standards of Practice for Home Inspections

A.C.E. Home Inspection Service St. Peters, MO (636)

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Inspection Report. Prepared Exclusively For:Joe Sample. Property Address: 552 Brindway. Raleigh NC

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Inspection Report. Sample Report. Property Address: 1234 Anywhere street Phoenix AZ. Veteran Inspection Professionals

Structure Survey Findings:

I NI NP R Inspected Items

Total Home Inspection Checklist

PROPERTY INSPECTION REPORT Property Address:

Inspecting to a higher standard.

Inspection Report. Mr. John Doe. Property Address: 123 Somewhere Jacksonville FL Tabor Hill & Associates LLC

Pre-Drywall Inspection Report

SWF Home Inspections

2. What building projects are exempted? (permit not required)

Inspection Report. Joe Smith Report. Property Address: 111 Main Street St Augustine FL Eagle Eye Home Inspections

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.

Home Management Checklist: Spring

Home Inspection Report

Orlando Home Inspection Services

A Seller s Guide to the Home Inspection By

Georgia Home Inspection Services

Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL Coast to Coast Property Inspections

HOME INSPECTION CHECKLIST

Propery Inspection Report

SECTION NC HOME INSPECTOR STANDARDS OF PRACTICE AND CODE OF ETHICS

GENERAL WIRING RULES FOR HOUSES

Does Wall Township require an inspection by the building department on resale of a home?

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

Home Inspection Report

Inspection Report. Happy 2 Flat Owner. Property Address: Focal Point Home Inspection Ltd.

Home Inspection Report

INSPECTION REPORT Customer 1.0 This report was performed for the exclusive use of

Inspection Item COMMENTS

HOMEOWNER S PERMIT GUIDE

159 Morningside Avenue, Toronto

Home Inspection Report

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Building Condition Assessment Report

Real Estate Inspection Report

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

GeorgiaHomePros.com Yellow Creek Road Ball Ground, GA Inspected By: Scott Webb

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

Property Inspection Report

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

Home Maintenance Checklist

Inspection Report GINA DONIE. Property Address: 225 CONNERS AVE NAPLES FL ARCHIVISION 4D LLC

Simplify. Homeownership

GENERAL ELECTRICAL REQUIREMENTS

Transcription:

Page 1 of 25 Inspection Report Atlanta Strip Mall Property Address: Smyrna GA 30082

Page 2 of 25 South East Building Consultants Ray Thoroman Serving the entire State of Georgia 6 678-410-3005

Page 3 of 25 Table of Contents Cover Page Table of Contents Intro Page 1 Roofing, Roof Structure, Chimneys, and Attic 2 Exterior 3 Structural Components 4 Plumbing System for Building 5 Offices / Suites (duplicate using the Components bar) 6 Rest Rooms / Other (duplicate using the Components bar) 7 Electrical System for Building 8 Heating / Cooling 9 Life-Safety General Summary Invoice

Page 4 of 25 Date: 6/26/2008 Time: 9:45:00 AM Report ID: 62608 Property: Smyrna GA 30082 Customer: Atlanta Strip Mall Commercial Building Comment Key or Definitions Real Estate Professional: The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this building. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property. Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear. Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting. Not Present (NP) = This item, component or unit is not in this building or building. Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement. Age Of building: Under 10 Years Client Is Present: Yes Radon Test: No Water Test: No Mold Test: No Weather: Clear Temperature: Over 75

Page 5 of 25 1. Roofing, Roof Structure, Chimneys, and Attic IN NI NP RR 1.0 ROOF COVERINGS 1.1 ROOF FLASHINGS 1.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS 1.3 ROOF VENTILATION 1.4 ROOF DRAINAGE SYSTEMS 1.5 ROOF STRUCTURE AND ATTIC (report leak signs or condensation) 1.6 FIREWALL SEPARATION BETWEEN UNITS IN ATTIC 1.7 ATTIC INSULATION 1.8 VENTILATION FANS THERMOSTATIC CONTROLS (ATTIC) 1.9 VISIBLE ELECTRIC WIRING IN ATTIC IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Styles & Materials Viewed roof covering from: Ladder Walked roof Roof-Type: Flat Roof Covering: Roll/Selvage Chimney (exterior): None Sky Light(s): None Roof Ventilation: None found Method used to observe attic: Open attic Roof Structure: Steel trusses Not visible Ceiling Structure: Not visible Attic info: No Attic Attic Insulation: None 1.0 (1) Recommend remove all debris from roof. 1.0 Picture 1

Page 6 of 25 (2) Standing water noted at roof mostly at left rear corner of building. Leaking and further damage may occur. Recommend repair by qualified roof contractor. 1.0 Picture 2 (3) Roof covering type for building is known as rolled selvage. Average life span in Georgia is approximately 6-12 years. Some small humps or raised sections were noted and may need repair (recommend further evaluation of these areas when roof contractor makes other know defective repairs). Recommend regular evaluation of roof covering by a qualified roof contractor. 1.0 Picture 3

Page 7 of 25 (4) Rear building roof service ladder was locked. Recommend obtaining key. 1.0 Picture 4 1.1 Recommend sealing all transitions at roof such as where metal cap meets stucco cladding and where metal cap meets roof covering. Leaking may occur. Recommend repair by qualified roof contractor. 1.1 Picture 1 1.9 No Attic. Some defective wiring noted above suspended ceiling. Please see electrical section of report for repair comments.

Page 8 of 25 2. Exterior 2.0 WALL CLADDING FLASHING AND TRIM 2.1 DOORS (Exterior) 2.2 WINDOWS 2.3 FOUNDATION WALLS AND MORTAR JOINTS 2.4 2.5 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PARKING LOTS,PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) IN NI NP RR 2.6 EAVES, SOFFITS AND FASCIAS 2.7 PLUMBING WATER FAUCETS (hose bibs) 2.8 POLARITY AND GROUNDING OF RECEPTACLES ON EXTERIOR WALLS OF INSPECTED STRUCTURE IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Styles & Materials Siding Style: Cement stucco Block and mortar Siding Material: Stucco Block Exterior Entry Doors: Steel Insulated glass Appurtenance: Sidewalk Patio Driveway: Asphalt Street Parking Parking lot

Page 9 of 25 3. Structural Components 3.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) 3.1 WALLS (Structural) 3.2 COLUMNS OR PIERS 3.3 FLOORS (Structural) 3.4 CEILINGS (structural) 3.5 3.6 3.7 INSULATION UNDER FLOOR SYSTEM AND EXTERIOR WALLS VAPOR RETARDERS (ON GROUND IN CRAWLSPACE OR BASEMENT) VENTILATION OF FOUNDATION AREAS (crawlspace or basement) IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR IN NI NP RR Styles & Materials Foundation: Poured concrete Method used to observe Crawlspace: No crawlspace Floor Structure: Slab Not visible Wall Structure: Not Visible Columns or Piers: Not Visible Floor System Insulation: NONE 3.5 Or not visible.

Page 10 of 25 4. Plumbing System for Building IN NI NP RR Styles & Materials 4.0 PLUMBING DRAIN, WASTE AND VENT SYSTEMS Water Source: Public Plumbing Water PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS 4.1 Supply (into AND FIXTURES building): HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND Not visible 4.2 VENTS Plumbing Water 4.3 MAIN WATER SHUT-OFF DEVICE (Describe location) Distribution (inside building): FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior Copper 4.4 fuel storage, piping, venting, supports, leaks) Plumbing Waste: PVC 4.5 MAIN FUEL SHUT OFF (Describe Location) Plumbing 4.6 SUMP PUMP Venting: PVC IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Water Heater Power Source: Electric Water Heater Capacity: 80 Gallon (plenty) Water heater Manufacturer: BRADFORD-WHITE Water Heater Age: 2006 4.0 (1) Several drain waste lines for sinks did not have visible P-Traps. Recommend repair by licensed plumber. 4.0 Picture 1 4.0 Picture 2

Page 11 of 25 (2) Plumbing vent piping was capped off at rear roof of building. Recommend repair by licensed plumber. 4.0 Picture 3 4.1 Bottom element cover for electric water heater was not properly secured. I noted plumbing water piping for hot and cold was reversed at faucets. Cold water produced luke warm temperatures. Recommend further evaluation and repair by licensed plumber. 4.1 Picture 1

Page 12 of 25 4.2 Bottom element cover for electric water heater was not properly secured. I noted plumbing water piping for hot and cold was reversed at faucets. Cold water produced luke warm temperatures. Recommend further evaluation and repair by licensed plumber. 4.2 Picture 1 4.3 I could not locate the main shut-off for water? Please ask the current owners for the location. Recommend making main water shut-off valve readily accessible. 4.4 Gas was not turned onto building at time of inspection. I could not test any gas operated appliances for proper operation. 4.4 Picture 1 4.5 Main gas valve is located rear of building and labeled unit A.

Page 13 of 25 5. Offices / Suites (duplicate using the Components bar) 5.0 CEILINGS 5.1 WALLS 5.2 FLOORS 5.3 DOORS (REPRESENTATIVE NUMBER) 5.4 WINDOWS (REPRESENTATIVE NUMBER) 5.5 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS 5.6 OUTLETS AND WALL SWITCHES IN NI NP RR 5.7 STEPS, STAIRWAYS, BALCONIES AND RAILINGS 5.8 SMOKE DETECTORS IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Styles & Materials Ceiling Materials: Suspended ceiling panels Unfinished Wall Material: Sheetrock Floor Covering(s): VCT Tile Interior Doors: Wood Window Types: Store Front

Page 14 of 25 6. Rest Rooms / Other (duplicate using the Components bar) IN NI NP RR 6.0 CEILINGS 6.1 WALLS 6.2 FLOORS 6.3 DOORS (REPRESENTATIVE NUMBER) 6.4 WINDOWS (REPRESENTATIVE NUMBER) 6.5 PLUMBING SUPPLY, FIXTURES 6.6 PLUMBING DRAIN, WASTE AND VENT SYSTEMS 6.7 OUTLETS AND WALL SWITCHES 6.8 VENTING SYSTEMS IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Styles & Materials Ceiling Materials: Suspended ceiling panels Wall Material: Sheetrock Floor Covering(s): Tile Vinyl Bath Exhaust Fans: Fan only Dryer Power Source: 220 Electric Dryer Vent: Metal

Page 15 of 25 7. Electrical System for Building IN NI NP RR Styles & Materials Electrical Service 7.0 SERVICE ENTRANCE CONDUCTORS Conductors: Below ground SERVICE AND GROUNDING EQUIPMENT, MAIN 7.1 Aluminum OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS 208 volts BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES Panel capacity: 7.2 AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE 400 AMP Panel Type: CONNECTED DEVICES AND FIXTURES (Observed from a Circuit breakers representative number operation of ceiling fans, lighting 7.3 Electric Panel fixtures, switches and receptacles located inside the Manufacturer: house, garage, and on the dwelling's exterior walls) SQUARE D Branch wire 15 POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 and 20 AMP: FEET OF INTERIOR PLUMBING FIXTURES, AND ALL 7.4 Copper RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF Wiring Methods: INSPECTED STRUCTURE Romex OPERATION OF GFCI (GROUND FAULT CIRCUIT NM Cable 7.5 INTERRUPTERS) 7.6 LOCATION OF MAIN AND DISTRIBUTION PANELS 7.7 SMOKE DETECTORS IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR 7.1 Key for electrical access panel ( dead cover ) was noted inside. Recommend putting key in accessible place if you lock the panel cover. 7.1 Picture 1

Page 16 of 25 7.3 (1) Rear private restroom switch plate is damaged. Recommend repair by licensed electrican. 7.3 Picture 1 (2) Exposed electrical wiring noted in several areas above suspended ceiling inside building. Electrical wiring was also not properly secured. This is a safety issue. Recommend repair by licensed electrican. 7.3 Picture 2

Page 17 of 25 (3) Electrical extension cord was plugged into unit B HVAC system on roof. This extension cord is hanging unplugged at the front of your building. Recommend remove extension cord. 7.3 Picture 3 7.6 The main panel box is located in kitchen area inside. However, the main disconnect (shut-off) is outside at meter base panel ( Your unit A for your information). I was not able to open the main disconnect cover (painted shut) recommend making main disconnect accessible. 7.6 Picture 1

Page 18 of 25 8. Heating / Cooling IN NI NP RR Styles & Materials Heat Type: 8.0 HEATING EQUIPMENT Forced Air Energy Source: 8.1 PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Natural gas 8.2 COOLING AND AIR HANDLER EQUIPMENT Number of Heat Systems PRESENCE OF INSTALLED COOLING SOURCE IN EACH 8.3 (excluding wood): ROOM One 8.4 NORMAL OPERATING CONTROLS Heat System Brand: 8.5 AUTOMATIC SAFETY CONTROLS LENNOX DISTRIBUTION SYSTEMS (including fans, pumps, ducts Heating System 8.6 and piping, with supports, insulation, air filters, registers, Age: radiators, fan coil units and convectors) 2003 Ductwork: CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water Insulated 8.7 heaters or heat systems) and Non-insulated 8.8 SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove) Filter Type: 8.9 GAS/LP FIRELOGS AND FIREPLACES N/A Filter Size: IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR N/A Types of Fireplaces: None Operable Fireplaces: None Number of Woodstoves: None Cooling Equipment Type: Air conditioner unit Cooling System Age: 2003 Cooling Equipment Energy Source: Electricity Central Air Manufacturer: LENNOX Number of AC Only Units: One 8.0 Gas was not turned onto building at time of inspection. I could not test for proper operation. Recommend turning gas on and having a licensed HVAC contractor further evaluated the unit.

Page 19 of 25 8.2 Condensation piping for HVAC unit drains directly onto roof. Recommend extend piping to side of building. Further damage may occur. Recommend repair by licensed HVAC contractor. 8.2 Picture 1 8.3 HVAC piping sealed off rear building. 8.6 HVAC duct piping was not properly connected to register vents (partially closed off). Energy loss is occurring and condensation may cause damage. Recommend repair by licensed HVAC contractor. 8.6 Picture 1

Page 20 of 25 8.7 Flue piping was installed for a gas water heater, however an electrical water heater is currently being used. Some water stains/leaking was noted. Recommend removing or properly sealing off flue pipe by qualified contractor. 8.7 Picture 1

Page 21 of 25 9. Life-Safety 9.0 3 ft Clear Space around Fire Hydrants 9.1 Portable Extinguishers readily available and present 9.2 Presence of sprinkler systems 9.3 Presence of emergency lighting systems 9.4 Presence of sign over lockable exit doors '' This door must remained unlocked during business hours'' 9.5 Exterior exits 9.6 Exit signs at all exits have separate power source such as batteries 9.7 Presence of at least two exits to exterior 9.8 Inspect for fire separation doors that do not automatically shut IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace 9.4 Recommend repair. IN NI NP RR IN NI NP RR

Page 22 of 25 General Summary South East Building Consultants Serving the entire State of Georgia 6 678-410-3005 Customer Atlanta Strip Mall Address Smyrna GA 30082 The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the building. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 1. Roofing, Roof Structure, Chimneys, and Attic 1.0 ROOF COVERINGS Repair or Replace (2) Standing water noted at roof mostly at left rear corner of building. Leaking and further damage may occur. Recommend repair by qualified roof contractor. (3) Roof covering type for building is known as rolled selvage. Average life span in Georgia is approximately 6-12 years. Some small humps or raised sections were noted and may need repair (recommend further evaluation of these areas when roof contractor makes other know defective repairs). Recommend regular evaluation of roof covering by a qualified roof contractor. (4) Rear building roof service ladder was locked. Recommend obtaining key. 1.1 ROOF FLASHINGS Repair or Replace

Page 23 of 25 1. Roofing, Roof Structure, Chimneys, and Attic Recommend sealing all transitions at roof such as where metal cap meets stucco cladding and where metal cap meets roof covering. Leaking may occur. Recommend repair by qualified roof contractor. 4. Plumbing System for Building 4.0 PLUMBING DRAIN, WASTE AND VENT SYSTEMS Repair or Replace (1) Several drain waste lines for sinks did not have visible P-Traps. Recommend repair by licensed plumber. (2) Plumbing vent piping was capped off at rear roof of building. Recommend repair by licensed plumber. 4.1 PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Repair or Replace Bottom element cover for electric water heater was not properly secured. I noted plumbing water piping for hot and cold was reversed at faucets. Cold water produced luke warm temperatures. Recommend further evaluation and repair by licensed plumber. 4.2 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Repair or Replace Bottom element cover for electric water heater was not properly secured. I noted plumbing water piping for hot and cold was reversed at faucets. Cold water produced luke warm temperatures. Recommend further evaluation and repair by licensed plumber. 4.3 MAIN WATER SHUT-OFF DEVICE (Describe location) Repair or Replace I could not locate the main shut-off for water? Please ask the current owners for the location. Recommend making main water shut-off valve readily accessible. 7. Electrical System for Building 7.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Repair or Replace (1) Rear private restroom switch plate is damaged. Recommend repair by licensed electrican. (2) Exposed electrical wiring noted in several areas above suspended ceiling inside building. Electrical wiring was also not properly secured. This is a safety issue. Recommend repair by licensed electrican. (3) Electrical extension cord was plugged into unit B HVAC system on roof. This extension cord is hanging unplugged at the front of your building. Recommend remove extension cord. 8. Heating / Cooling 8.2 COOLING AND AIR HANDLER EQUIPMENT Repair or Replace

Page 24 of 25 8. Heating / Cooling Condensation piping for HVAC unit drains directly onto roof. Recommend extend piping to side of building. Further damage may occur. Recommend repair by licensed HVAC contractor. 8.6 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Repair or Replace HVAC duct piping was not properly connected to register vents (partially closed off). Energy loss is occurring and condensation may cause damage. Recommend repair by licensed HVAC contractor. 9. Life-Safety 9.4 Presence of sign over lockable exit doors '' This door must remained unlocked during business hours'' Not Present Recommend repair. Prepared Using HomeGauge http://www.homegauge.com : Licensed To Superior Home Inspections

Page 25 of 25 INVOICE South East Building Consultants Serving the entire State of Georgia 6 678-410-3005 Inspected By: Ray Thoroman Inspection Date: 6/26/2008 Report ID: 62608 Customer Info: Atlanta Strip Mall 1654 Fair Way Marietta GA 30060 Inspection Property: Smyrna GA 30082 Customer's Real Estate Professional: Inspection Fee: Service Price Amount Sub-Total Building Inspection 650.00 1 650.00 Payment Method: Check Payment Status: Paid At Time Of Inspection Note: Tax $0.00 Total Price $650.00