Georgia Association of Home Inspectors



Similar documents
South Carolina Home Inspector Standards of Practice

BUILDING SAFETY UNIT

PDmB, Inc. Definitions

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Pre-Drywall Inspection Report

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

Uniform Construction Code (UCC) Building Permit Application Package

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

License Requirements for Persons Engaging in the Business of Inspection Practice:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

I NI NP R Inspected Items

South Carolina Home Inspector Standards of Practice

Applications for building permits will not be reviewed until all of the required information has been submitted.

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/20/2009)

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

HOME INSPECTOR STANDARDS OF PRACTICE

Development Services City of Lawrence, KS

Structure Survey Findings:

Chapter 6 ROOF-CEILING SYSTEMS

Self-Home Inspection Checklist

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

HV AC CODE CHECKLISTS

HEDDERMAN ENGINEERING, INC Carrie Cove Ct., Spring, TX , fax

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

GENERAL ELECTRICAL REQUIREMENTS

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

October 5, 2015 Dear Client,

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

Inspecton Report. Property Address:

Mark Cramer Inspection Services, Inc.

GENERAL WIRING RULES FOR HOUSES

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

POST AND FRAME STRUCTURES (Pole Barns)

Vision Home Inspection

How To Make A House Safe

Inspection Tech. (330) Inspected By: Aaron Westerburg

Does Wall Township require an inspection by the building department on resale of a home?

Propery Inspection Report

Residential Code Requirements

The Uniform Building Inspection Report Condensed

GENERAL INFORMATION FOR RESIDENTIAL CONSTRUCTION ( IF APPLIES )

HOMEOWNER S PERMIT GUIDE

INFORMATION BULLETIN NO.

Inspection Item COMMENTS

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

Typical Finished Basement Details

The purpose of this document is to provide standards for persons requesting or subject to County building inspections.

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

City of Elk River BASEMENT Office Use Only

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

BUILDING PERMIT SPECIFICATIONS

INSPECTION GUIDELINES

COMPREHENSIVE PROPERTY INSPECTIONS

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

Building Code Inspections and Fees

2010 Residential Water Heater Replacement Check List

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Total Home Inspection Checklist

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Home Inspection Report

2009 IRC CODE CHANGES

Residential Deck Safety, Construction, and Repair

Single Family Residential Basement Finish

RRIO Checklist. Use of checklist: Definitions: Limitations

RESIDENTIAL SITE INSPECTIONS

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

HOME INSPECTION CHECKLIST

Building Permits: When are they required?

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Residential Electrical Inspection. Checklist

Building, Plumbing, Electrical and Residential Water and Sewer Inspection Requirements

HomeSpec REPORT SUMMARY

Home Inspection Report

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Residential Plan Routing Information

October 6, (B) the vantage point from which the crawl space was inspected; and

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

PROPERTY INSPECTION REPORT

Typical Finished Basement Details

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

Basement Development Construction requirements for the development of basements in residential dwellings.

City of Oviedo Commercial Shell Building Permit Application Guidelines

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

Basic Requirements for Residential Plan Review _

Residential Foundations and Basements

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

PROPERTY INSPECTION REPORT

Solar Panel Installations

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

PLAN SUBMITTAL INFORMATION

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Botetourt County, Virginia. Residential Information Handout

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Transcription:

Georgia Association of Home Inspectors Standards of Practice for Framing Inspections OVERVIEW The purpose of the GAHI (Georgia Association of Home Inspectors) Standards of Practice for Framing Inspections is to establish a uniform guide for performing inspections of construction in one and two family dwellings. The Standards are intended to set minimum requirements for inspecting, reporting and describing conditions that affect the property and human safety. The Standards define and clarify terms, procedures, scope and conditions and limitations as they relate to a GAHI approved inspection and report. GAHI is proud that these are the most rigorous requirements of any home inspection organization in the United States. PURPOSE The purpose of the GAHI Framing Inspection is to reduce the public s risk by providing a general inspection of the conditions of the structure as they exist at the time of the inspection and to attempt to identify areas where substandard or deficient construction has the potential for future damage or injury. The purpose of the GAHI Framing Inspection is to supply a written summary describing the inspection findings. SCOPE The scope of the GAHI Framing Inspection is a visual inspection, with limited use of mechanical instruments and should not be considered exhaustive. Due to time consideration it is a general inspection of visible conditions. The inspection is limited to readily accessible areas of the grounds and building components. Systems and conditions that are not within the scope of the inspection include, but are not limited to environmental hazards, pest infestation, portable appliances, security systems, telephone systems, audio equipment, intercom systems, timers, fire or lawn sprinklers, swimming pools, spas, jetted tubs, tennis courts, playground or other recreational equipment, solar heating systems, below ground septic or drainage systems, water wells, zoning ordinances, building code conformity, or any item considered to be cosmetic in nature. Any comments about these systems and conditions are informational only and do not represent an inspection. The GAHI inspector takes no position on property value nor makes any representation as to advisability of purchase or suitability of use of the property. INSPECTOR QUALIFICATIONS GAHI recommends that only Code Certified Inspectors be retained to perform this type of inspection. GAHI Code Inspectors have demonstrated extensive knowledge of Framing Inspections by passing the International CodeCouncil approved One and Two Family Dweling Inspection examination. ICC writes building codes for residential construction in the United States. These codes have been adopted into law by the State of Georgia and many others. GAHI Inspectors have also demonstrated knowledge of construction by passing GAHI s other required exams. Page 1 of 10

Finally, each GAHI Certified Inspector is required to have performed at least 250 home inspections according to the GAHI Standards of Practice and maintain GAHI approved continuing education. WARRANTIES AND GUARANTEES The GAHI inspection report is not intended to be used as a guarantee or warranty, expressed or implied, regarding adequacy, performance, or condition of any inspected building, improvement, mechanical system or appliance. STANDARDS OF PRACTICE The following Standards provide guidelines for the GAHI inspector. The guidelines outline what the GAHI inspector should observe, identify, inspect and describe. The guidelines provide the minimum contents of a written report and are not intended to limit the GAHI inspector from performing additional inspection services. Consult the Glossary for the definition of the intended use of words. Words not included in the Glossary should be defined using Webster s Dictionary. A framing inspection is commonly made after the roof, masonry, all framing, firestopping, draftstopping and bracing are in place and after the plumbing, mechanical and electrical rough inspections are approved. We intend to base our inspections on this Standard. Different designs, types of construction and situations may necessitate that other items be inspected. GENERAL LIMITATIONS The inspector is not required to: 1. Perform any task or access any area that may place him or her in danger. 2. Perform any task that may cause damage to the structure or contents. 3. Dismantle any item by other than means provided for the end user. 4. Move any items. 5. Perform Engineering or Cost Estimates. 6. Determine the life expectancy of any component or system. 7. Perform efficiency or performance evaluation of equipment or systems. 8. Inspect any item or system not specifically required by these Standards. GENERAL REQUIREMENTS The inspector is required to report: 1. Observed items that may be a threat to human safety. 2. Observed failure of any item or system. 3. Observed conditions that may lead to potential problems. 4. Observed items or systems that are not complete. 5. Observed items that appear to be in used condition. 6. Why any item required by these standards was not reported on. 7. The GAHI inspector is not required to perform code inspections; however, should the inspector choose to cite code deficiencies, the inspector must identify the code by year and section for the permit year of the house. The GAHI Inspector should describe the materials used and report on the condition and/or any deficiencies in the following areas of the structure. Page 2 of 10

FRAMING INSPECTION Roof / Ceiling Construction (Chapter 8-IRC) Components of roof/ceiling construction fastened per appropriate- Table R602.3(1) Rafter spans Tables per R802.5.1(1) thru R802.5.1(9) Grade marks on rafters per R404.2.1 Allowable deflection of structural members per Table R301.7 Ends of rafters to bear on 1 ½ of wood or metal or 3 on masonry- R802.6 Cutting and notching of rafters- R 802.7 Boring of holes in rafters- R802.7 Framing around openings/headers- R802.9 Attic ventilation- R806.1 thru R806.3 Bracing of trusses (trusses require engineer s design) (any truss supporting equipment must be designed for such)- R802.10 Altered or damaged trusses (repairs require design by engineer or truss manufacturer)- R802.10.4 Trusses must be connected to wall plate with connectors (not nailed) R802.10.5 Roof purlins, struts and bracing where required- R802.5.1 Roof bracing to load bearing wall or beam- R802.3 Depth of ridge board not less than end cut of rafter- R802.3 Lower rafter ties where required (when ceiling joist not nailed to rafters to form a continuous tie between exterior walls, rafter ties required on every rafter; collar ties every 4 ft).- R802.3.1 Hip and valley rafters supported at ridge or designed to carry specific load- R802.3 Hip and valey rafters not less than 2 nominal thickness and not less in depth than end cut of rafter- R802.3 Ceiling joist spans Table R802.4(1) thru R802.5(6) Grade marks on ceiling joists- R404.2.1 Ends of ceiling joists to bear 1 ½ on wood or metal, or 3 on masonry- R802.6 Cutting and notching of ceiling joists- R802.7 Boring of holes in ceiling joists- R802.7 Cathedral ceilings rafters ends supported on bearing walls attached to ridge beam capable of supporting imposed roof loads (may require engineer s design)- R802.3.1 Ceiling joists used to resist rafter thrust lapped minimum 3 or buted and atached in manner to resist such thrust- R803.3.2 Page 3 of 10

Lateral bracing of rafters and ceiling joists where required- R802.8, R802.8.1 Bridging of rafters and ceiling joists where required- 802.8, 802.8.1 Roof tie downs where required- R802.11 Walls Components of wall construction fastened per appropriate Table R602.3(1) Grade marks on studs #3 standard or stud grade (see code exceptions) R602.1, R602.3 Allowable deflection of structural members per Table- R301.7 Studs over 10 may require engineer s design- R602.3.1, Bearing wall studs spaced and sized per Table- R603.3.1,Table R602.3(5) Exterior wall top plates doubled and joints spaced properly- R602.3.2 Interior load bearing partitions constructed, framed and fireblocked as specified for exterior walls- R602.8, R314.8 Drilling and notching of studs- R602.6 Drilling and notching of top plates- R602.6.1 Headers (#2 grade lumber) sized per (header tables not for use with concentrated loads engineer s design required)- Table R502.5(1) Fireblocking required- R602.8 Cripple walls framed and braced properly- R602.9, R602.10.2 Exterior and foundation wall panels framed and braced per Table- Seismic Zone B- R602.10.3, Table R602.10.3, 602.10.4, 602.10.5 Anchor bolts/straps installed and spaced correctly- R403.1.6 Exterior wals within 3 of property line must be no less than one hour fire resistive rated- R302.1, Table R302.1 Minimum size window openings required in bedrooms- R310.1 Masonry veneers greater than 40 pounds per square foot not to be supported by wood construction unless by design- R703.7 Floors Components of floor construction fastened per Table- 505.3.1(1) Floor joist spans Tables R502.3.1 Grade marks on floor joists- R 502.1 Allowable deflection of structural members Table- R301.7 Floor joists, beams and girders capable of accommodating all loads imposed- R501.2 Page 4 of 10

Floor joists under parallel or perpendicular bearing partitions sized to accommodate loads imposed- R502.4 Floor joists to bear on 1 ½ of wood or metal, 3 on masonry- R502.6 Floor joists lapped appropriately- R502.6.1 Floor joists framed into the side of wood girder supported appropriately (hangers or ledgers)- R502.6.2 Cutting and notching of floor joists- R502.8.1 Boring of holes in floor joists- R502.8.1 Floor joists supported laterally at ends- R502.7 Bridging where required- R502.7 Framing of openings and required header and trimmer joists and approved hangers- R502.10 Posts, beams and girder construction require positive connection to ensure against uplift and lateral displacement- R502.9 Floor trusses designed by engineer- R502.11 Draftstopping required- R502.12 Grade marks on floor sheathing and installed and fastened per- R503.2 General Protection against decay of joists, sill plates, siding, wall sheathing, studs, etc. where applicable due to clearances- R319 Minimum headroom at stairs- R314.3 Minimum ceiling heights- R311.5.2 Chimneys and Fireplaces Masonry chimney minimum clearance to combustibles, 2 for interior clearances, 1 for chimney located entirely outside the exterior walls- R1001.11 Chimney crickets sized appropriately- R1003.20 Chimney height- R1003.9 Factory built fireplaces installed from combustible material permanufacturer sinstallation instructions Required firestopping installed at floor and ceiling penetrations-r1003.19 Page 5 of 10

ELECTRICAL ROUGH INSPECTION (Based on the National Electric Code) Service Entrance Proper clearance of overhead conductors Main disconnect readily accessible and within 6 7 of final grade Ampacity sufficient for service entrance conductors (record size) Support of service conductors Record location of main service disconnect Bonding and Grounding Verify grounding electrode installed properly Grounding electrode conductor continuous (no splices) and properly attached (Since 1/1/2006, concrete encased electrode (rebar) must be used if present in foundation Service equipment properly bonded Metallic water and gas piping, building steel properly bonded Separate bonding conductor for subpanels Metal boxes properly grounded Whirlpool pump bonding Main Electrical Panel Sufficient working space Panel not located in bathroom or clothes closet Record sizes and type of cable installed for major appliance circuits Wiring Methods and Materials Device boxes for receptacles installed on exterior front and rear, not to exceed 6 6 above grade Device box located for garage receptacle Device box located for basement receptacle Proper spacing of receptacles for habitable rooms (2 wal spaces, 6 spacing rule) Proper spacing of receptacles for kitchen counter tops (12 and wider, 2 spacing rule) Instalation of receptacle for island and peninsular counters (greater than 1 x 2 ) Receptacle provision for bathroom lavatories (one per each unless located between basins) Receptacle provision for laundry area Page 6 of 10

Provision for hallway receptacle (halway greater than 10 ) Heating and air conditioning disconnects, service receptacles, lights (in attic, crawl space and exterior) Required lighting outlets and switches Lighting at exterior entrances Support of conductors and installation of wiring method Proper identification of conductors Boxes properly located and supported Junction boxes located so as to be accessible Floor boxes suitable for use Box fill Unused openings closed Wiring protected from physical damage, stud edges, attic access NM (Romex) cable supported and secured Page 7 of 10

PLUMBING ROUGH INSPECTION (Based on International Plumbing Code) Drain, Vent and Sewer Piping Sewer cleanout installed within 10 ft. of house & since 1/1/2007 within 10 ft. of right-of-way Drains and vents sized properly Fittings installed with proper orientation for flow Cleanouts installed and accessible as required Vent termination Water Supply Piping Accessibility and location of plumbing fixtures correct Backflow preventers installed as required Since 1/1/2007 water hammer arrestors required for quick-closing valves Since 1/1/2007/ Anti-scald devices required to be installed for tubs with two lever faucets General Notching and boring according to code Protective straps (nailguards) installed (extend two inches on each side of pipe) Piping properly supported according to size, function, etc. Workmanship Page 8 of 10

Gas Piping Sized properly for appliances Properly supported Shut off valves installed as required Sediment Traps installed as required Equipment Equipment properly located and installed Clearances MECHANICAL ROUGH INSPECTION Walkway and service platform correct for attic installations Light and receptacle for attic and crawl space installations Ductwork Material approved for use Clearances Insulation and joints properly sealed Ductwork properly supported Since 1/1/2008 Duct insulation must be R-8 in attics & crawlspaces (2006 IECC) Ducts properly sealed Exhaust Systems Dryer exhaust (smooth pipe, length within requirements, etc.) Bathroom vent fans (located where required and properly terminated to outside) Terminations (hood, etc.) Combustion Air Requirements per rated input for appliances Proper installation of ducts Chimney and Gas Flues Material correct Clearances Properly sized Properly terminated through roof or wall General Condensate drain pans installed where required Page 9 of 10

Drain piping (normal and emergency) properly supported and sloped Page 10 of 10