Solid Phase Extraction for Water Analysis. presented by



Similar documents
Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Oasis HLB Cartridges and 96-Well Plates

How To Test For Contamination In Large Volume Water

Bulk Materials for Preparative and Process Chromatography

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Innovative vs Traditional

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Purification of reaction mixtures using flash chromatography.

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

SPE Reference Manual & Users Guide. Reference Manual & Users Guide

A Novel Approach to Low Volume Sample Preparation

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Thermo Scientific Chromatography Columns and Consumables Your world of. chromatography

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Biocides main groups

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

ORGANIC SAMPLE PREPARATION

Affi-Prep Protein A Matrix Instruction Manual

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Sample Preparation for Forensic Toxicology and Clinical Research. Part 1: Sample Preparation Options

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Guide to Solid Phase Extraction

Sample Preparation Using Solid Phase Extraction

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

General Chromatography

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Separation by Solvent Extraction

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Agilent SampliQ Products for SPE. Improve the quality of your SPE so you can improve the quality of your analysis.

PrepTip. Reverse Phase PrepTip User Guide

Opiates in Urine by SAMHSA GC/MS

The Theory of HPLC. Gradient HPLC

Click on Table of Contents. Then type desired page number & click OK.

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Experiment 3: Extraction: Separation of an Acidic, a Basic and a Neutral Substance

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

6. ANALYTICAL METHODS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC

Optimization of SPE for Analysis of Mandelic Acid as a Biomarker of Exposure to Ethyl Benzene

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

SiliaPrep. SPE Cartridges and Well Plates

We are committed to providing with the highest quality products and services in the industry.

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

The basic division explosives for forensic purposes is shown in Fig. 1

[ DISQUE DISPERSIVE SAMPLE PREPARATION EXTRACTION PRODUCTS ] QuEChERS. Simplifed

INSTRUCTIONS Edition AC

Sorbents. [ A] [ A] aq. Strong affinity = large K D. Digital chromatography: all-or. or-nothing LC mechanism to extremes K =

105 Adopted:

HiPer Ion Exchange Chromatography Teaching Kit

Chromatography...Oh Yeah!

Chapter 6. Solution, Acids and Bases

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

CORESTA RECOMMENDED METHOD N 72

Chapter 13 Solution Dynamics. An Introduction to Chemistry by Mark Bishop

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

E. Marenna a, E. Santacesaria b, P. Pernice a, M. Di Serio b, A. Aronne a

AG 501-X8 and Bio-Rex MSZ 501(D) Mixed Bed Resin Instruction Manual. Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules CA LIT205 Rev B

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

UltraClean PCR Clean-Up Kit

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

S olid Ph ase Extraction (SP E) Method:

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Training Courses 2014 HPLC GC SPE

LC-MS/MS for Chromatographers

Determination of Tricyclazole in Water Using Solid Phase Extraction and Liquid Chromatography

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Chemistry 51 Chapter 8 TYPES OF SOLUTIONS. A solution is a homogeneous mixture of two substances: a solute and a solvent.

SAMPLE PREPARATION. Your Essential Resource for Supplies

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Transcription:

Solid Phase Extraction for Water Analysis presented by Dr. Bernd Thierfelder

Outline 1. Introduction in SPE 2. Retention Mechanisms / Sorbent Selectivity 3. strata -X for Water Analysis 4. Applications of Water Analysis

1. Introduction in SPE

What is Solid Phase Extraction (SPE)? It s a very selective and effective sample preparation method. A day in the life of a scientist Collect Specimen SAMPLE PREPARATION Analysis (HPLC, GC,...) Data Handling Homogenization Dilution Weighing Settling and Decanting Centrifugation Filtration Enzymatic Hydrolysis Evaporation Protein Crash / Precipitation Liquid / Liquid Extraction Solid Phase Extraction

Three Goals of SPE Before SPE 1. Purification/Clean up After SPE 0 minutes 10 0 minutes 10 2. Concentration, e.g. from 1 Liter to 1 ml 3. Solvent Switch, e.g. from water to MeOH 1 Liter Dirty Water SPE 1 ml Concentrated Analytes

Processing Samples with a Vacuum Manifold, a pump and a waste trap Sample reservoir is connected to cartridge by a tubing and adaptor cap. Atmospheric pressure pushes water sample through cartridge and flow is controlled by stopcocks between cartridge and cover of manifold.

SPE of Aqueous Samples Example: A green sample containing a blue (non-polar) and yellow (polar) dye can be separated with SPE. Sample Matrix Contaminants Target Analyze(s) green dye yellow = hydrophilic blue = hydrophobic (polar) (non-polar)

Steps of SPE 1a. 1b. 2. 3. 4. Condition Equilbrate Load sample Wash Elute The two steps remove air and wet phase; phase is extended to its max. level. Analytes are retained by the sorbent. Contaminants are washed off the phase. Analytes are eluted from the phase.

2. Retention Mechanisms / ete t o ec a s s / Sorbent Selectivity

SPE of Analytes from Water Analytes in Water SPE Phase must have a high h retentivity ti it towards analytes. Interactions must be stronger than analyte s solubility in water. Water

Retention Mechanism Hydrophobic / Non-Polar / Reversed Phase Typical phases: C18, C8, Phenyl, Polymers (i.e. PSDVB, strata-x) Most common for aqueous samples / Huge difference in polarity between phase and water. Organic compounds interact with organic solid phase due to their organic frame.

Retention Mechanism Hydrophilic / Polar / Normal Phase Typical phases: Silica, Florisil, NH 2, CN In most cases used for strong organic and non-aqueous environmental samples like hexane.

Retention Mechanism Ion Exchange Ionic interactions Typical phases: SCX, WCX, SAX, WAX (NH 2 ), strata-x-c, -X-CW, -X-AW Can be used for aqueous environmental samples if just a specific ionic class of analytes has to be extracted. Adjusting appropriate ph for load and elution step is necessary.

Matrix Polarity of sample and solid phase must be opposed. Liquid Phase / Sample Aqueous: Water, biological fluids, aqueous homogenates Organic: Non-polar organic solvents Solid Phase Non-Polar C18, C8, Phenyl, SDB, strata-x Polar Silica, Florisil, NH 2, CN Ion Exchange Aqueous or Organic SCX, WCX, SAX, WAX, strata-x-c, -X-CW, -X-AW

Sorbent Selectivity Selection of sorbent dependent on analyte and sample matrix. These sorbents have a single retention mechanism. Most common RP phases Classic Sorbents Most common NP phases SDB Polymer C18E C18U C8 Phenyl CN NH 2 Si FL-PR SCX, WCX, SAX Non-polar Reversed Phase Sorbents for organic compounds in aqueous environmental samples, e.g. surface water. Polar Normal Phase Sorbents for polar organic compounds in organic solvents e.g. organic soil extracts. Ionic IEX Sorbents for specific ionic compounds from aqueous or organic samples.

Sorbent Selectivity Question: Can a sorbent have more than one retention mechansim? Multiple Modes Mixed Phases: Hydrophobic + Ion exchange Typical phases: strata Screen C and strata Screen A Universal : Hydrophobic + Hydrophilic Typical phases: modified polymers such as strata-x Universal : Hydrophobic + Hydrophilic + Ion exchange Typical phases: modified polymers such as strata-x-c(w), -AW

3. strata-x for Water Analysis

Modern Polymer Sorbents strata-x / strata-x-c(w) / strata-x-aw strata-x: strata-x-c: strata-x-cw: strata-x-aw: hydrophobic and hydrophilic retention mechanism for neutral non-polar and polar compounds strata-x + strong cation exchange for bases strata-x + weak cation exchange for strong bases strata-x + weak anion exchange for acids 33 µm and 100 µm particles with large surface area > 800m 2 /g / 500m 2 /g ph stability 1-1414

Advantages of strata-x Series es Simplicity: One method approach High & reproducible recoveries for acids, bases and neutrals Can be used for all kinds of environmental aqueous samples High ph stability (ph 1-14) High capacity lower solvent consumption Resistant to de-conditioning Clean = LC/MS and GC/MS friendly

strata-x simplifies Method Development Step 1 Step 2 Step 3 Step 4 Condition 5mL of methanol. Equilibrate with 5mL water Load sample Wash impurities with 5mL of a 5% methanol solution in water Elute analyte with 3-5mL of methanol! Method based on a 200mg sorbent bed mass

4. Applications cato sof Water Analysis ayss

Multiresidue solid phase extraction of 16 pesticides from groundwater coupled with high-performance liquid chromatography * SPE Method Sorbent: strata-x, 200mg/6mL Conditioning: 10mL dichloromethane Load: 10mL acetontrile 10mL water 1L water sample Wash: water/methanol (95:5 v/v) Elution: 5mL acetonitrile 5mL methanol * Talanta 71 (2007) 25 30, Angelo Antonio D Archivio, Maria Fanelli, Pietro Mazzeo, Fabrizio Ruggieri Universit`a degli Studi di L Aquila, Dipartimento di Chimica, Ingegneria Chimica e Materiali, Via Vetoio, 67010 Coppito, L Aquila, Italy

Solid phase extraction of pesticides from surface water * SPE Method Sorbent: strata-x, 200mg/6mL Conditioning: 3x 1mL MeOH/ACN (1:1, v/v) 3x 2mL water Load: 1L water sample (+ 0.5g NaCl) Dry: 1h nitrogen stream Elution: 3x 1mL MeOH/ACN (1:1, v/v) Pesticides Recovery [%] RSD [%] n = 4 Set value [ng/l] Desethylsimazin 85 5,8 100 2,6-Dichlorbenzamid 84 5,9 100 Ethidimuron 86 4,9 200 Chloridazon 86 3,6 50 Desethylatrazin 87 6,5 100 Desethylsebuthylazin 84 4,9 100 Bromacil 77 5,1 200 Simazin 84 7,1 100 Metribuzin 76 7,9 200 Desethylterbuthylazin 82 6,7 100 Metabenzthiazuron 82 5,4 50 Chlortoluron 83 4,5 50 Atrazin 82 9,0 100 Diuron 81 5,6 100 Isoproturon 81 5,5 100 Metazachlor 78 6,7 100 Terbumeton 77 9,1 100 Sebuthylazin 83 5,5 50 Propazin 79 10,3 50 Dimefuron 79 1,9 100 Terbuthylazin 78 9,0 100 Triadimenol 84 0,9 100 Epoxiconazol 80 2,6 200 Terbutryn 77 6,3 100 Metolachlor 71 16,2 200 Propiconazol 81 4,1 200 Kresoxim-methyl 79 3,5 100 * By courtesy of Mr. Cornelius Schmidt-Leistner from the Bayerisches Landesamt für Wasserwirtschaft in Munich.

Determination of selected human pharmaceutical compounds in effluent and surface water samples by high-performance liquid chromatography * SPE Method Sorbent: strata-x, 200mg/6mL Conditioning: 3x 2mL methanol 3x 2mL water 3x 2mL water, ph 3 Load: 1L water sample, ph 3 Dry: vacuum aspiration Elution: 3x 2mL methanol * Journal of Chromatography A, 1015 (2003) 129 141, Martin J. Hilton, Kevin V. Thomas Centre for Environment, Fisheries and Aquaculture Science (CEFAS), Burnham Laboratory, Remembrance Avenue, Burnham on Crouch, Essex CM0 8HA, UK

Quantification of β-lactam antibiotics in urine and wipe samples from environmental and biological monitoring by SPE and LC-MS/MS Institute of Energy and Environmental Technology (IUTA), D-47229 Duisburg, Germany

Thank kyou for your attention strata-x is a trademark of Phenomenex Inc. Florisil is a registered trademark of U.S. Silica Company.