On behalf of: Deutsche Steinzeug Cremer & Breuer AG Servaisstraße 53347 Alfter-Witterschlick



Similar documents
Photocatalyst Activity Indicator Ink for medium activity self-cleaning films such as glass. First Working Draft

UV Induced Wetting of 2 by Water

The photoionization detector (PID) utilizes ultraviolet

Waste Air Cleaning System. Effective reduction of: Pollutants Odours Solvent emissions

A Look at Accelerated Photostability Testing for Packaged Food and Drinks

Supplementary Information for. Nitric oxide emission during the reductive heterogeneous photocatalysis of aqueous nitrate

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

Experience. The Atlas Difference.

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

Solar energy Solar technology in endurance testing

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

Indoor Air Comfort Test Report

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

FRAUNHOFER INSTITUTe For

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

STABILITY TESTING: PHOTOSTABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS

FINESORB Surface Area. as or more than m 2 /g. Distribution of Pore nm. Degas & Analysis Up to 12 Degas & 6 Analysis Station

Using Assigned Protection Factors (APFs) for Respirator Selection Use with Chapter WAC, Respirators

Power Resistor for Mounting onto a Heatsink Thick Film Technology

ICH Q1B Guideline. Photostability Testing of New Drug Substances and Products

Spectrophotometer - Milton Roy Spectronic 21D or equivalent.

MAKING A BETTER MARK WITH INK JET As substrates, industry regulations and customer demands change, fluids are also evolving

Design qualification and type approval of PV modules

File M C2 - Document DE/1 - Page 1/5 TEST REPORT. This document is a translation in the lab of original report M Document DE/2 in french

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Preliminary Comments

ICC Recommendations for Color Measurement

TAIYO PSR-4000 AUS703

Dew-Point Measurement Solutions

Accelerated Aging and Life Time Prediction for Solar Concentrators

Photocatalyst, the new generation of environmental purification

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

CONSERVATION AND LIGHTING

Federal Institute for Materials Research and Testing

Keywords: Torque, calibration, uncertainty, torque tools, torque testers. Contents

POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES

Double Coated Urethane Foam Tapes

SMD PTC - Nickel Thin Film Linear Thermistors

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

Ces deux analyseurs permettent le contrôle de la qualité de l eau et des effluents.

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.

Technically speaking, THE WHITEST WHITE

DATA SHEET CHIP RESISTORS RT Series 1%; 0.5%; 0.25%; 0.1%

AMBIENT AIR QUALITY MONITORING SYSTEM. Air Quality Monitoring... Easier. Faster. Better.

PROPOSED ADDENDA TO EPA/AUTO PROTOCOL FOR COMPLIANCE ASSURANCE MONITORING

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Supporting Information

We bring quality to light. ISP Series Integrating Spheres

TC50 High Precision Power Thin Film chip resistors (RoHS compliant Halogen Free) Size 1206, 0805, 0603

SUCRALOSE. White to off-white, practically odourless crystalline powder

Dimensional Change Characteristics for Printed Circuit Board Films

Are these noise cancelling devices needed to make your chiller quiet??

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

Appendix 5 Overview of requirements in English

Light and Radiation Techniques for Airbag System Testing Burkhard Severon K.H.Steuernagel Lichttechnik GmbH

Research on the Transport and Chemistry of Fission Products in Primary Circuit and Containment Conditions at VTT

BEHAVIOR OF ASPHALTS. in the PRODUCTION OF ASPHALTIC CONCRETE. Project HR-107 Iowa Highway Research Board

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability.

Application Requirement

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Do UV Nail Lamps Emit Unsafe Levels of Ultraviolet Light?

presented by Neal Leddy CMA Analytical Workshop 2012 SURFACE AREA AND POROSITY

How To Use An Irius Pid Detector

The Limitations of Hand-held XRF Analyzers as a Quantitative Tool for Measuring Heavy Metal Pesticides on Art Objects. By Özge Gençay Üstün

Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile

AQUADA UV Eliminate Bacteria in Your Drinking Water!

The atomic packing factor is defined as the ratio of sphere volume to the total unit cell volume, or APF = V S V C. = 2(sphere volume) = 2 = V C = 4R

Metrological features of a beta absorption particulate air monitor operating with wireless communication system

Republic of Panama Superintendency of Banks

Basic Properties and Application of Auto Enamels

No. STSE-CW2163B <Cat.No > SPECIFICATIONS FOR NICHIA WHITE LED MODEL : NSPW315BS NICHIA CORPORATION -0-

Analysis of Chlorine, Bromine and Iodine in Water using ICP-AES

AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin)

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

How To Choose A Total Organic Carbon Analyzer

A NOVEL APPROACH FOR CHARACTERIZING CARBON CATALYSTS BY TAP EXPERIMENTS

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

ß-CYCLODEXTRIN SYNONYMS

THE MAINTENANCE FACTOR FOR LED LIGHTING

SOLAR CELLS From light to electricity

Cartridge Change Schedule

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Owner s Manual

Gas sensors for greenhouse measurements

What is Solar Control?

Evaluating Protective Coatings for Ballast Tanks

The new frontier of luxury porcelain slabs

Product Line DUST. The family of hermetic luminaires

USER GUIDE. LED Light Meter. Model LT45

In-line 3D Sputtering Coating System. Fully automated. pst line

Description of Thermal Oxidizers

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

SULFUR IMPREGNATION ON ACTIVATED CARBON FIBERS BY H 2 S OXIDATION FOR Hg REMOVAL

Transcription:

FRAUNHOFER-INSTITUTE FOR SURFACE ENGINEERING AND THIN FILMS, TEST REPORT Determination of the air purification performance of semiconducting photocayalytic materials by removing nitric oxide in accordance with ISO 22197-1 On behalf of: Deutsche Steinzeug Cremer & Breuer AG Servaisstraße Performed by: Institute for Surface Engineering and Thin Films Tobias Graumann (Graduate Chemist) Bienroder Weg 54 E, 38108 Braunschweig Tel.: 0531/2155-780, Fax: 0531/2155-900 tobias.graumann@ist.fraunhofer.de Braunschweig, 1st November 2013

1. Subject matter of the work The subject matter of this test report is the determination of the air purification performance of materials that contain a photocatalyst or have a photocatalytic film on the surface. The sample to be tested was continually exposed to the airborne pollutant nitric oxide () while being illuminated with ultraviolet light. The net amount of x removed from the sample is therefore the way of measuring photocatalytic activity, whereby a subsequent elution test to recover surface adsorbates was not performed. The work was performed based on ISO 22197-1. In deviation from this the volume flow was reduced from 3 L/min to 1 L/min. This method is suitable for photocatalytic materials which have been produced for air purification applications. This test is not suitable for calculating the other photocatalytic characteristics of photocatalytic materials, such as the water purification performance, self-cleaning, antifogging or anti-bacterial characteristics. This method solely concerns the removal of nitric oxide. 2. Overview of the tested samples For the performance of the tests, was provided with a homogenously coated felt sample with the following dimensions: 49.5±0.5 x 99.5±0.5 mm. The samples submitted by the client for testing were previously blown with nitrogen and pre-activated with UV illumination. No. Sample 1 HT coating Sample name 2 5

3. Overview of the test conditions Test procedure Test laboratory Based on ISO 22197- Test method for air-purification performance of semiconducting photocatalytic materials Part 1: Removal of nitric oxide Institute for Surface engineering and thin films Bienroder Weg 54 E 38108 Braunschweig Test period 31/10/2013 01/11/2013 Tester Tobias Graumann (graduate chemist) Description of the sample White tile with the dimensions: 49.5 x 99.5 mm Pre-treatment of sample Blown with nitrogen, UV pre-conditioning Laboratory conditions 21±2 C, 49±7% RH Test conditions 1 ppmv of nitric oxide in the test air (KW-free) at 1 L/min Temperature in the reactor: 21±1 C Air humidity in the reactor: 50±2% RH Analyzer Environment S.A., AC32M Chemiluminescence detector, no auxiliary gases, selective measurement, pre-reaction chamber for cyclical zero adjustment UV lamp (preconditioning) Philips Actinic fluorescent lamp BL TL-K 40W; 2,3 mw/cm²; Sample 1: exposure for 1 day, continual UV lamp (test) FSLED365.10_10, LED based surface radiator, 10 x 10cm, Omicron-Laserage Laserprodukte GmbH, 365 nm, 1.00 mw/cm² UV test device Deviations from the standard Ophir 3A-P-FS thermopile (Nova II), calibrated in September 2013 (Ophir Spiricon Europe GmbH) Reduction in the volume flow from 3 L/min to 1 L/min, no elution test (paragraph 8.3 ISO 22197- ) 3 5

Specific test results Graphic presentation of the test results: Sample 1: 1.0 Concentration / ppm 0.8 0.6 Adsorption phase 0.4 Degradation phase 0.2 x 2 Desorption phase 0.0 0 50 100 150 200 250 300 350 400 Time / min Tabular representation of the test results as per ISO 31-0, unit: µmol No. x adsorbed removed 2 generated x desorbed x removed Sample 1 0.0 1.7 1.3 0.0 0.4 4 5

4. Summary of the test results The photocayalytic air cleaning performance of the evaluated test specimens has been determined based on the net quantity of the removed nitric oxide (x). This has been calculated using the following formula: n x = n ads + n n 2 - n des whereby: n x n ads n n 2 = x removed from the test specimen (µmol), = x adsorbed from the test specimen (µmol), = removed from the test specimen (µmol), = 2 generated from the test specimen (µmol), n des = x desorbed from the test specimen (µmol), The net quantity of x removed, for the sample HT coating was 0.4 µmol and with the defined test parameters exhibited a photocatalytic air purification effect for the removal of nitric oxide. Braunschweig, November 2013 5 5