Florida Energy Efficiency Code For Building Construction



Similar documents
APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1

HVAC Simplified Approach Option

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

CALCS-PLUS Florida Building Code Energy Conservation Glitch Supplement

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Glossary of Heating, Ventilation and Air Conditioning Terms

RELEASE NOTES EG USA 3.0.0

IECC Compliance Guide for Homes in Virginia

Condensing Boiler Efficiency

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

Energy Efficiency in Industrial HVAC Systems

Energy Efficiency HOSPITALITY.

2014 British Columbia Building Code Changes

Exhibit IV Approved Measures List. Page 1 of 5

Be SMART Home Application

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Commercial Energy Efficiency Program. Save money, reduce energy use and earn incentives. Save money, reduce energy use and qualify for incentives

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Heating & Cooling Efficiency

energy-saving checklist a guide for rental property owners

2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT

Glossary of HVAC Terms

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

Home Management Checklist: Spring

Air Conditioning Sign-Off Sheet

Training for Building Technicians: Energy Efficiency & Sustainability (BEST) Program. Seminar Outline & Sample BEST Exam Questions

ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

City of Elk River BASEMENT Office Use Only

Center for Energy Education Laboratory

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Sample Customer 123 Conservation Way TAMPA FL Tracking Number:

Mechanical, Plumbing, and Fire Protection Conditions

HVAC Systems in Schools & Commercial Buildings and Radon

2009 IECC Update. Scope. Content. International Energy Conservation Code

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

780 CMR Part IV Energy Conservation. ENERGY EFFICIENCY (Note: Chapter 61 is unique to Massachusetts)

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Innovent LASER Packaged Fresh Air Conditioning Units

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Potential of Energy Efficiency and Renewable Energy Savings To Impact Florida s Projected Energy Use in 2014

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

2013 BUILDING ENERGY EFFICIENCY STANDARDS

PLAN SUBMITTAL INFORMATION

City of St. Charles Basement Finish or Remodel

How To Design An Hvac Design For A Stick Built Home

Lesson 36 Selection Of Air Conditioning Systems

This report presents the findings and recommendations of the assessment of energy use and

Cost-Effective, Energy-Efficient Home Improvements for Florida Homes August 8, 2012

Comparison of 2006 IECC and 2009 IECC Commercial Energy Code Requirements for Kansas City, MO

Botetourt County, Virginia. Frequently Asked Questions

SECTION MORTUARY REFRIGERATORS

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Building Condition Assessment Report

Chapter 2: Foundations

CHARLOTTE COUNTY Community Development Department

Category Measure Minimum Efficiency / Certification Requirements

Energy Efficiency. Bars & RestauRants.

PROPERTY INSPECTION REPORT

Sustainable Design and Energy-Efficient Building Techniques for Existing Housing

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study

101 Low-Cost /No-Cost. Home Energy-Saving Measures

How To Get A Building Permit In Florida

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Heating Load HERS: Calcs Duct Seal and Test (h), (m)1-3 & 11

BUILDING SAFETY UNIT

Installation Questions

Home inspectors are not mold inspectors, however they do inspect for defects that

WHEN IS A PERMIT REQUIRED?

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V Water II Heat Recovery VRF System)

Energy Efficiency in Buildings

BVCAA inc HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015

Crawford Inspection Services C.C.B. #

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

USER S MANUAL HSC-24A

Tips on Saving Energy in Your Business

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

COMPREHENSIVE PROPERTY INSPECTIONS

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

6 Ceiling fans! Although they only use about as. 8 Redecorate. Hang lighter colored curtains

Transcription:

Florida Energy iciency Code For Building Construction EnergyGauge Summit Fla/Com-2010, ective Date: March 15, 2012 -- Form 506-2010 Total Building Performance Method for Commercial Buildings PROJECT SUMMARY Short Desc: RefProj Description: New Project Owner: Enter Owner's name here Address1: 1234 Any Street City: Anywhere Address2: Enter Address here State: FL Zip: 12345 Class: New Finished building Jurisdiction: ALACHUA COUNTY, ALACHUA COUNTY, FL (111000) Conditioned Area: 10000 SF Conditioned & UnConditioned Area: 10000 SF No of Stories: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 50 If different, write in: Page 1 of 8

Compliance Summary Component Criteria Result Gross Energy Cost (in $) 5,005.0 8,885.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report Page 2 of 8

CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: John Doe Date: Building Official: Date: I certify that this building is in compliance with the FLorida Energy iciency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*) that the system design is in compliance with the Florida Energy iciency Code Architect: Electrical er: Lighting er: Mechanical er: Plumbing er: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Page 3 of 8

Building End Uses 1) Proposed 2) Baseline Total 347.80 $5,005 744.30 $11,107 ELECTRICITY(MBtu/kWh/$) AREA LIGHTS MISC EQUIPMT PUMPS & MISC SPACE COOL VENT FANS NATURAL-GAS(MBtu/therm/$ ) SPACE HEAT 301.00 88193 $4,771 15.70 4594 $249 100.00 29302 $1,585 0.20 45 $2 131.50 38539 $2,085 53.60 15713 $850 46.80 468 $234 46.80 468 $234 677.00 198349 $10,770 146.30 42873 $2,328 100.00 29302 $1,591 0.20 45 $2 274.50 80428 $4,367 156.00 45701 $2,482 67.30 673 $337 67.30 673 $337 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 45.1% PASSES Page 4 of 8

Description Category External Lighting Compliance Tradable? Allowance (W/Unit) Area or Length or No. of Units (Sqft or ft) ELPA (W) Ext Light 1 Uncovered Parking Areas -- Yes 0.15 1,000.0 150 40 Parking lots and Drives Ext Light 2 Internally illuminated exit signs No 5.00 8.0 40 35 Ext Light 3 Uncovered Parking Areas -- Parking lots and Drives Yes 0.15 CLP (W) Tradable Surfaces: 40 (W) Allowance for Tradable: 159.5 (W) All External Lighting: 75 (W) Complicance check includes a 5% excess allowance of 9.50(W) Ext Light 3 -- Does not meet control requirements of Type: <2><3> Project: RefProj Lighting Controls Compliance Acronym Ashrae ID Description Area (sq.ft) CP Min CP Compliance Pr0Zo1Sp1 14 Classroom/Lecture Hall 10,000 5 4 PASSES PASSES Page 5 of 8

System Report Compliance Pr0Sy2 System 2 Constant Volume Packaged System No. of Units 1 Component Category Capacity Criteria IPLV IPLV Criteria Compliance Cooling System Air Conditioners Air Cooled 240000 to 760000 Btu/h Cooling Capacity Heating System Warm Air Gas Furnace >= Air Handling System -Supply 225000 Btu/h Air Handler (Supply) - Constant Volume 15.00 9.30 9.50 95.00 80.00 PASSES 0.50 0.90 PASSES Plant Compliance Description Installed No Size Min IPLV Min IPLV Category Comp liance None Project: RefProj Water Heater Compliance Description Type Category Min Loss Max Loss Comp liance Water Heater 2 Electric water heater <= 12 [kw] 0.93 Water Heater 3 Electric water heater <= 12 [kw] 0.93 Page 6 of 8

Piping System Compliance Category Pipe Dia [inches] Is Runout? Operating Ins Cond Temp [Btu-in/hr [F].SF.F] Ins Thick [in] Req Ins Thick [in] Compliance Heating System (Steam, Steam Condensate, & Hot Water) 0.25 False 105.00 0.28 0.00 0.50 Page 7 of 8

Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge FlaCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows & Doors 502.3.2 Glazed swinging entrance & revolving doors: max. 1.0 cfm/ft²; all other products: 0.3 cfm/ft² Joints/Cracks 502.3.3 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling Cavity 502.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls HVAC iciency 503.2.3 Minimum efficiencies: Tables 503.2.3(1)-(8) HVAC Controls 503.2.4 Zone controls prevent reheat (exceptions); separate thermostatic control per zone; Ventilation 503.2.5 Outdoor air supply & exhaust ducts shall have dampers that automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and have been performed HVAC Ducts 503.2.7 Air ducts, fittings, mechanical equipment & plenum chambers shall be mechanically attached, sealed, insulated & installed per Table 503.2.7.2. Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s) tested & balanced. Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water. In accordance with Table 503.2.8. Water Heaters 504 Performance requirements in accordance with Table 504.2. Heat trap required. Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce heat loss on heated pools; Time switch (exceptions); readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met Lighting Controls 505.2, 502.3 Automatic control required for interior lighting in buildings >5,000 s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluorescent lamps>30w Page 8 of 8