M-Bus-Logger Data Logger



Similar documents
AMTRON E-30 Compact heat and cooling meter

Quick Connect. quick - simple - efficient.

PCS0100en Persy Control Services B.V. Netherlands

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Polyphase kwh Electricity Meter

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Telephone- and leased line modem for industrial applications TD-36

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Maximum Demand Control

M-Bus Network Installation Notes

Flexible Counter Series in DIN size 24 x 48 mm

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

A project to optimise quality and energy efficiency must include metering

3-phase, bidirectional energy meter

Application/Connection Examples

Documentation. M-Bus 130-mbx

HYDRUS ULTRASONIC METER

Multifunction devices

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Current Monitoring Kit QUICK START GUIDE

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Rack mounted telephone- and leased line modem for industrial applications

Remote Monitoring and REC 501 Control Unit Product Guide

Inwall 4 Input / 4 Output Module

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Frequency selective monitoring and logging of environmental electromagnetic fields

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

BUSINESS SYSTEMS MONITORING

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

650W Single Output Power Supply

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

USB-500 Series Low-Cost Data Loggers and Accessories

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Voltage Regulator SPAU 341 C. Product Guide

ZC-24DO CANopen I/O Module: 24 Digital Outputs

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

USB-500/600 Series Low-Cost Data Loggers and Accessories

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Modular I/O System Analog and Digital Interface Modules

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

EARTH LEAKAGE PROTECTION: CONTENTS

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

ELCOMPONENT LTD. User Manual

MOUNTING AND OPERATING INSTRUCTIONS

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

OZW30. Central Unit SYNERGYR

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

CONFIGURABLE SAFETY RELAYS

The multi-functional integrator Supercal 531

Duct Humidity Transmitter

Current Monitoring Kit

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

II Intelligent PC/CAN Interface. Manual

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Physical Specifications (Custom design available.)

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Remote Meter Reading via M-Bus by Klaus-Peter Richter, Energy Management Product Manager GOSSEN METRAWATT GMBH

Preset Counter signo 721

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

DS 600. A contact free flux gate based current measurement sensor 600A rms

Waveguide Access Point WGA631. Product Guide

DMX2PWM 9 Channel Dimmer Setup Manual

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

NC-12 Modbus Application

SURGE PROTECTIVE DEVICES

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

4-Channel Thermometer / Datalogger

PHONE MANAGER INDEX. page

MINI MCR-SL-R-UI(-SP)

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

is then retained absolutely without interruption.

HARTING mcon 1000 Introduction and features

M3 ORANGE single-slot Cradle. User Guide. Product Number: A-1CR-US0D-030-R00, A-1CR-U0ED-030-R00. Compatible Device(s): M3 ORANGE

Z-TWS4. Multifunction Straton / LINUX Controller.

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

UPS Network Interface. Quick InstallationGuide

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Disturbance Recoder SPCR 8C27. Product Guide

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

CONFIGURABLE SAFETY RELAYS

Transcription:

Data Logger User Manual Doc.-No.: E102312514074 Bär Industrie-Elektronik GmbH Rathsbergstr. 23 D-90411 Nürnberg Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com

COPYRIGHT Copyright 2014 BÄR Industrie-Elektronik GmbH. All rights, including those originating from translation, (re)-printing and copying of this document or parts thereof are reserved. No part of this manual may be copied or distributed by electronic, mechanic, photographic or indeed any other means without prior written consent of BÄR Industrie-Elektronik GmbH. All names of products or companies contained in this document may be trademarks or trade names of their respective owners. Note Based on its policies, BÄR Industrie-Elektronik GmbH develops and improves their products on an ongoing basis. In consequence, BÄR Industrie-Elektronik GmbH preserve the right to modify and improve the software and hardware products described in this document. Specifications and other information contained in this document can change without prior notice. This document does not cover all functions in all possible detail or variations that may be encountered during installation, maintenance and usage of the software. Under no circumstances whatsoever will BÄR Industrie-Elektronik GmbH accept any liability for mistakes in this document or for any sub sequential damage arising from installation or usage of the software. BÄR Industrie-Elektronik GmbH preserves the right to modify or withdraw this document at any time without prior announcement. BÄR Industrie-Elektronik GmbH does not accept any responsibility or liability for the installation, usage, maintenance or support of third party products. Printed in Germany 2

Table of Contents 1 General... 4 1.1 M-Bus... 4 1.2 M-Bus Structure... 4 1.3 Communication... 5 2 M-Bus-Logger... 6 2.1 Pulse inputs... 7 2.2 LED-Displays... 8 2.3 Parameterization... 8 2.4 Data Storage... 9 3 Technical Data... 10 3.1 Dimensions... 11 3

1 General 1.1 M-Bus The M-Bus system is a data transmission system for acquiring, evaluating, optimizing and controlling energy and process data. Modular components permit networking of a large number of different energy meters and computer-controlled terminals. The high degree of noise immunity, even in noisy environments, ensures reliably and error-free measured value transmission. Via modem interfaces, it is also possible to cover large distances to connect modular expansions or complex substation systems. The M-Bus system is the system preferred by operators supplying numerous consumers (e.g. industry and technology parks, trade fairs, building managements, etc.). 1.2 M-Bus Structure An M-Bus system consists of user specifically configurable and task specific system components and different repeaters that are grouped together in one or more segments via a simple twisted-pair cable. The structure of an M-Bus segment can be designed as a: Star structure Linear structure Tree structure Figure 1, M-Bus segment 4

Each segment is terminated with a repeater and connects up to 250 terminals. Repeaters can be cascaded, i.e. segments can brunch to lower level segments. The control centre of an M-Bus system is formed by the M-Bus master. It consists of an M-Bus repeater connected to a normal commercially available PC. Figure 2, M-Bus structure 1.3 Communication Data transfer at the M-Bus is executed serial as Master-Slave operation via M-Bus master or mini master with RS232 interface to PC: Figure 3, Communication A two-wire standard telephone cable (e.g. JYStY N*2*0.8 mm or better) is used as the transmission line for the M-Bus. 5

2 M-Bus-Logger The M-Bus-Logger has a modular design in top-hat rail installation. The following options are available (changeable vie parameterization software): Load profile: 4000 values ( ca. 40 day with 15 min. registration period) Billing data: for 16 resets (e.g.: 16 month-values) For both option the date will be saved by 8 digits with time stamp; Programming and data retrieval by M-Bus (according to DIN EN 1434-3); The following device types are possible: Reed-Inputs: without supply voltage, includes internal Lithium-Battery S0-Inputs, Option 1: with supply voltage 15VDC - 24VDC S0-Inputs, Option 2: with supply voltage 230VAC or 115VDC Reed-Inputs and Option 1: Option 2: Figure 4, Device type This description includes all types of the device. 6

2.1 Pulse inputs The following pulses are available: Potential-free reed pulse, voltage 2,6 to 3,6V (via M-Bus), standard S0 pulse according to DIN 43864 (only with AC or DC supply voltage), optional The register overflow happens from 2 147 483 647 (conforms to 7FFFFFFF hexadecimal) to 0. Reed-Inputs (without supply voltage) S0-Inputs Option 1: 15VDC - 24VDC S0-Inputs Option 2: 230VAC or 115VAC Mix (Option 1) Mix (Option 2) 7

2.2 LED-Displays The functions of the M-Bus-Logger are displayed by two LED s: LED Function Description M-Bus (yellow) Error (red) Dimly lit Blinking light Permanent light Flash M-Bus on-line Data communication via M-Bus Permanent error: Data error in the measurement memory (EEPROM) Action: The M-Bus-Logger must be sent to the manufacturer for service Measuring period: at the begin of new measuring period (e.g. every 15 min.) the Error-LED flashes for one second. 2.3 Parameterization The device can be programmed via the die M-Bus interface (according to DIN EN 1434-3) with the software MBusLogSet. It provides following functions: Set date, clock, baud rate, device address, register value, etc. Read configuration Read data Figure 5, Parameterization program MBusLogSet 8

Factory settings for M-Bus-Logger (if not differently ordered): Baud rate: 2400 Baud (8E1) Primary address: 0 Secondary address: serial number (8 digits) Option (for data storage): load profile, registration period 15 minutes 2.4 Data Storage Bus-Logger consists following components (needed for internal registration memory): Internal Lithium-Battery M-Bus voltage (active ca. 36VDC) Note: For option 1 with supply voltage (15VDC to 24VDC) is for recording of load profile the M-Bus voltage needed! Optionally supply voltage Reed-Inputs with M-Bus active Reed-Inputs without M-Bus S0-Inputs with supply voltage with M-Bus active Pulse logging (Reed): yes Load profile with time stamp: yes S0-Inputs without supply voltage with M-Bus active Pulse logging (Reed): yes Load profile with time stamp: no S0-Inputs with supply voltage without M-Bus Pulse logging (S0): yes Pulse logging (Reed): yes Load profile with time stamp: yes S0-Inputs without supply voltage without M-Bus Pulse logging (S0): no Pulse logging (Reed): yes Load profile with time stamp: yes Pulse logging (S0): yes Pulse logging (Reed): yes Load profile with time stamp: yes Pulse logging (S0): no Pulse logging (Reed): yes Load profile with time stamp: no 9

3 Technical Data Housing: top-hat rail installation Degree of protection: IP20 Dimensions: W = 35+1 mm (Option 1) or 70+2 mm (Option 2) H = 90 mm D = 58 mm Protection class: 2 Auxiliary power (M-Bus): max. 3mA via M-Bus (:= 2 M-Bus standard load) Battery: Type: Lithium 3,6V (necessary for load profile) Lifespan: ca. 8 years without M-Bus connection Supply voltage: optional (possible for S0 pulses only) None: Reed-Inputs only Option 1: 15VDC to 24VDC (S0 and Reed) Option 2: 230VAC (S0 and Reed) or 115VAC Interface: M-Bus passive (according to DIN EN 1434-3) Baud rate: 300, 2400 (default), 9600 or 19200 Baud 8E1 Software interface: According to IEC 60870-5 primary or secondary addresses Pulse inputs: No.: 2 Type: Reed (all versions) or S0 (Option 1 or 2 only) Pulse frequency: max.12hz, pulse length 40ms minimum Option: 150Hz (pulse length 0,05ms / break 5ms) Pulse input reed: Potential-free, min. 1MΩ isolation Capacity: < 2nF (incl. cable) Resistor: open > 1 MΩ close < 2kΩ Voltage: 2,6 to 3,6V Currency: ca. 11μA Pulse input S0 (Option): According to DIN 43864 Adjustment: 1..255 / 1..255 Measuring period : 1min to 24hours Real time clock: max. deviation 30 sec/month at 25 C (10ppm) Data storage: Load profile: max. 4000 values Billing data: max. 16 resets LED: 2 LED s for: Error and M-Bus Extent of delivery: - M-Bus-Logger with 2 Reed-Inputs Optional: - Power supply for AC or DC - 2 pulse inputs for S0 pulses Order-Number: 11913: 2 Reed-Inputs, without supply voltage 12405: 2 S0-Inputs, supply voltage 15VDC to 24VDC 11792: 2 S0-Inputs, supply voltage 115VAC 11821: 2 S0-Inputs, supply voltage 230VAC Accessories: - M-Bus Master / Repeater / Mini Master - Cable - Software MBusLogSet - AMR-Software (e.g. SIGLON) 10

3.1 Dimensions 11

Subject to change without notice!