SEMINAR 23: Data Center and IT Equipment Liquid Cooling: Performance Capabilities, Implementation and Emerging Technologies



Similar documents
Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL

Guide to Minimizing Compressor-based Cooling in Data Centers

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

DC Pro Assessment Tools. November 14, 2010

Data Center Environments

Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings

HPC TCO: Cooling and Computer Room Efficiency

Elements of Energy Efficiency in Data Centre Cooling Architecture

Data Center Energy Efficiency. SC07 Birds of a Feather November, 2007 Bill Tschudi wftschudi@lbl.gov

Improving Data Center Efficiency with Rack or Row Cooling Devices:

University of St Andrews. Energy Efficient Data Centre Cooling

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

The Effect of Data Centre Environment on IT Reliability & Energy Consumption

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

Typical Air Cooled Data Centre Compared to Iceotope s Liquid Cooled Solution

European Code of Conduct for Data Centre. Presentation of the Awards 2014

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

SURVEY RESULTS: DATA CENTER ECONOMIZER USE

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Managing Data Centre Heat Issues

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

AIRAH Presentation April 30 th 2014

Oil Submersion Cooling for Todayʼs Data Centers. An analysis of the technology and its business implications

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Analysis of data centre cooling energy efficiency

Variable-Speed Fan Retrofits for Computer-Room Air Conditioners

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Data Center Leadership In the DOE Better Buildings Challenge

IBM Portable Modular Data Center Overview for Critical Facilities Round Table

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

How does solar air conditioning work?

Low GWP Replacements for R404A in Commercial Refrigeration Applications

DataCenter 2020: first results for energy-optimization at existing data centers

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

Warehouse-scale Design Reaches Retail Colocation High Density, Modern And Green

A Paradigm Shift in Data Center Sustainability Going Beyond Aisle Containment and Economization

Reducing Data Center Energy Consumption

Submersion Cooling Evaluation

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How To Find A Sweet Spot Operating Temperature For A Data Center

Green ICT: Consistent Actions to Reduce Energy Consumption

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Improving Data Center Energy Efficiency Through Environmental Optimization

The New Data Center Cooling Paradigm The Tiered Approach

Chiller-less Facilities: They May Be Closer Than You Think

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

News in Data Center Cooling

Alfa Laval Abatigo. Redefining adiabatic cooling

Increasing Energ y Efficiency In Data Centers

Specialty Environment Design Mission Critical Facilities

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Data Center RD&D at EPRI

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

Guidance for Calculation of Efficiency (PUE) in Data Centers

Data Centers. Comparing Data Center & Computer Thermal Design

The Different Types of Air Conditioning Equipment for IT Environments

The Pros and Cons of Modular Systems

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

How To Improve Energy Efficiency In A Data Center

Air Conditioning 101. STN Presentation AC101

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

Recommendation For Incorporating Data Center Specific Sustainability Best Practices into EO13514 Implementation

European Code of Conduct for Data Centre. Presentation of the Awards 2016

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

How To Run A Data Center Efficiently

How To Understand Evaporator

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

STULZ Water-Side Economizer Solutions

Smarter Data Centers. Integrated Data Center Service Management

Transcription:

Michael K Pa+erson, PhD, PE, DCEP Intel Corpora7on michael.k.pa+erson@intel.com SEMINAR 23: Data Center and IT Equipment Liquid Cooling: Performance Capabilities, Implementation and Emerging Technologies Considerations of Non-Conventional Liquid Cooling Immersion Technologies 1

Learning Objectives Understand the basic implementation differences and thermal performance advantages of liquid cooled ITE. Describe the performance and density advantages of liquid cooled ITE and understand the trends in ITE highlighting the limitations of current cooling solutions as well as why liquid cooling is being implemented. Introduce the ASHRAE liquid cooling classes and the impact these classes have on the data center design. Demonstrate liquid cooling using real world case studies to understand the advantages and challenges of implementing liquid cooling. ASHRAE is a Registered Provider with The American Ins9tute of Architects Con9nuing Educa9on Systems. Credit earned on comple9on of this program will be reported to ASHRAE Records for AIA members. Cer9ficates of Comple9on for non- AIA members are available on request. This program is registered with the AIA/ASHRAE for con7nuing professional educa7on. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construc7on or any method or manner of handling, using, distribu7ng, or dealing in any material or product. Ques7ons related to specific materials, methods, and services will be addressed at the conclusion of this presenta7on.

Acknowledgements Robin Steinbrecher & Dev Kulkarni (Intel), Michael Ellsworth & Dustin W Demetriou (IBM), Jason Matteson (Lenovo), Thomas Howe (ANL) DoD ESTCP* Bill Tschudi & Henry Coles Lawrence Berkeley National Laboratory Tim McCann SGI Jeanie Osburn US Naval Research Laboratory Ozan Tutunoglu - Schneider Electric Phil Tuma 3M * ESTCP: Environmental Security Technology Certification Program 3

Overview Immersion cooling types Compare and contrast immersion and direct liquid cooling Immersion Cooling Benefits Immersion Cooling Challenges Case Study Opportunities and Next Steps for Immersion 4

Immersion cooling fluid properties & types Characteristics Dielectric Thermal / Fluid Properties Engineered Fluids Two Phase Single Phase Oils Types 5

Immersion in use Engineered Fluids Oil 6

Immersion Benefits Cools everything in the bath Selectable fluid temperatures Low PUE and ITUE Free cooling opportunity Heat recovery opportunity Platform design options Do very little (e.g. TIM changes, seal hard drives, boiling enhancement, thermal management changes) Go wild (current form-factors driven by airflow path, many opportunities exist for denser, cheaper designs) 7

Immersion Challenges Material compatibility Fluid costs Engineered Fluids expensive Evaporative loss minimization critical to TCO Oils reasonable Service Model Platform management Platform configuration Warranty 8

Qualitative Comparisons Immersion - Oil Disclaimer: Immersion Engr Fluids Direct Liquid Liq Air Combo Air Comments The values on this slide are solely the Thermal Performance ++ +++ ++ + 0 Two- phase advantages opinions of the presenter, are site Serviceability - - - - - - - - 0 Oil messy, 2 phase evaporates CapEx IT/Facility +/++ - -?/+++ - - /++ - /- - 0 Fluid cost dependent, and likely never agreed to OpEx IT/Facility ++/+++ ++?/+++ ++/++ +/+ 0 Fluid replacement cost Efficiency PUE/ITUE ++/+++ +++/+++ ++/+++ 0/+ 0 Several good choices by a large group. Reliability IT/Facility +++/++ ++/++ +/++ - - /- 0 Lower = good, stable = good Op7miza7on - Efficiency ++ +++ + 0 0 Reduce leakage, reduce ITUE The key message is that EACH SITE Op7miza7on - Performance ++ +++ ++ + 0 Higher speeds w/ cooler chips Energy Reuse Poten7al ++ +++ ++ + 0 % removed & quality of heat must consider all these factors in Water Savings ++ +++ ++ 0 0 Free cooling w/o evapora7on High density in Legacy DC ++ + + +++ 0 Ease of adding to older DC their decisions and do their own Applica7on in new DC +++ +++ +++ - 0 Two flavors of cooling suffers Market Ready/Risk - - - - - - - 0 Will change with 7me analysis. There is no best answer for Noise +++ +++ +++ + 0 Ahhhh, thank you Air Corrosion +++ +++ + + 0 Direct s7ll exposes IT to air 0 = baseline + = be+er - = worse 9

Qualitative Comparisons Immersion - Oil Immersion Engr Fluids Direct Liquid Liq Air Combo Air Comments Thermal Performance ++ +++ +++ + 0 Two- phase advantages Serviceability - - - - - - - - 0 Oil messy, 2 phase evaporates CapEx IT/Facility +/++ - -?/+++ - - /++ - /- - 0 Fluid cost OpEx IT/Facility ++/+++ ++?/+++ ++/++ +/+ 0 Fluid replacement cost Efficiency PUE/ITUE ++/+++ +++/+++ ++/+++ 0/+ 0 Several good choices Reliability IT/Facility +++/++ ++/++ +/++ - - /- 0 Lower = good, stable = good Op7miza7on - Efficiency ++ +++ + 0 0 Reduce leakage, reduce ITUE Op7miza7on - Performance ++ +++ ++ + 0 Higher speeds w/ cooler chips Energy Reuse Poten7al ++ +++ ++ + 0 % removed & quality of heat Water Savings ++ +++ ++ 0 0 Free cooling w/o evapora7on High density in Legacy DC ++ + + +++ 0 Ease of adding to older DC Applica7on in new DC +++ +++ +++ - 0 Two flavors of cooling suffers Market Ready/Risk - - - - - - - 0 Will change with 7me Noise +++ +++ +++ + 0 Ahhhh, thank you Air Corrosion +++ +++ + + 0 Direct s7ll exposes IT to air 0 = baseline + = be+er - = worse 10

Case Study: Open bath liquid immersion cooling using engineered fluids Vapor Condenser Boiling Liquid Server Tank Facility Wall Facility Water Pump Dry Tower Ambient as high as 55 C IT Power Cooling Power = Pump + Fan q Goal is to evaluate energy savings poten7al using immersion 11

Cooling temperatures Immersion systems can cool at relatively high cooling temperatures 49 C & 61 C boiling point options depending on fluid Both are cool compared to chip temperatures Dry coolers (no water use J ) can condense engineered fluids easily in most climates Cooler temperature can drive performance OR warmer temperature can optimize energy re-use Case study using 49 C 12

OFF IDLE LINPACK RUN Immersion Demonstra7on 13

Insert Movie Here 14

Energy Performance PUE cooling = IT+TankControls+DryCoolerFan+LoopPump /IT ITUE cooling = IT+internalITcooling/IT TUE cooling =ITUE PUE 15

Initial Results PUE cooling = IT+TankControls+DryCoolerFan+LoopPump /IT PUE cooling = 20.930+0.0719+0.144+0.254 /20.930 = 1.022* ITUE cooling = IT+internalITcooling/IT = 1.00 TUE cooling =ITUE PUE=1.022 We are up and running, and seeing energy benefits * Current results using fixed speed (100%) fans and pumps 16

Immersion cooling eliminates compressor based systems Eliminate chillers and CRAC units Eliminate cooling towers & evapora7ve water loss Reduce number of pumps Eliminate server fans More hours of Free cooling Simplified controls Reduced maintenance cost Cooling systems can be much simpler 17

Case Study Expected Benefits Capital cost savings Improved reliability Elimination of potential points of failure Temperature stability improving reliability Energy savings (IT and infrastructure) Enables high density computing and close interconnection of processors In the future, electronics can be optimized for immersion for even better performance More potential for heat reuse Additional applications e.g. aviation, military 18

Immersion Next Steps Complete the DoD Evaluation Performance & TCO Continue to explore chemical compatibilities Evaluate other issues Signal Integrity Optical interconnect Track market adoption and performance Consider immersion-optimized platforms What new designs might this enable? 19

Conclusions General Immersion cooling can offer a wide range of new design opportunities and optimizations Work continues to explore how to bring it more mainstream Case Study Engineered fluids are well suited to the high density of HPC Minimizing fluid loss will be very important to TCO success We expect learn a lot around system design and material issues in our test 20

Bibliography DoD ESTCP Web Site, https://www.serdp-estcp.org/program-areas/energyand-water/energy/conservation-and-efficiency/ EW-201347 LBNL Website, datacenters.lbl.gov Patterson, M.K. and Best, C., Seminar: Oil Immersion Cooling and Reductions In Data Center Energy Use, ASHRAE 2012 Annual Meeting, San Antonio, Texas Sorell, V., Tuma, P., Newcombe, L., Liquid Cooling in Data Centers, Part 2, ASHRAE Trans., Report 3460, July 3, 2013. 21

Questions? Michael K Patterson michael.k.patterson@intel.com 22