EKOS Cart. Instructions for Use



Similar documents
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

How To Use A Power Supply Unit (Upu)

BC Pro UPS System Standby UPS System

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Model #: SMART2200CRMXL

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Internet Office UPS System Standby UPS for PCs, workstations and more

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

esata External Storage

Online UPS. PowerWalker VFI 1000R/1U

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Uninterruptible Power Supply

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

350, 500, 650 and 1000 MODELS

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

User s Manual AURORA 1.2K/2.2K

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Installation and Operation Back-UPS 1250, 1300, 1500

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Dehumidifier Users manual. For Models: DH45S DH65S

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

User Manual 1K/2K/3K Online UPS

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

USER MANUAL Online UPS 1K/2K/3K Rack

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Powerware 5110 UPS User s manual

750VA/1000VA/1500VA 100/120/230VAC 2U

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Residential Gateway (RG) Battery Backup

USER MANUAL Online UPS 1K/2K/3K

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Back-UPS Pro 1300/1500 Installation and Operation

MAJORSINE Power Inverter

Advantium 2 Plus Alarm

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Internet Office 500VA Tower Standby 120V UPS with USB port

Installation and Operation

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Line Interactive UPS

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

BroadBand PowerShield. User Manual

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

3000W Power Inverter

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000/1500 VA. 100/120/230 Vac. Rack Mount 2U

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

Portable Air Conditioner

Preface. Manual Revisions

Zip40 Charging Cart. User's Guide. Components. Tools Needed ENGLISH. For the latest User Installation Guide please visit:

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

10000HXL31/15000HXL31/20000HXL31

Single Day Alarm Clock with. Bluetooth and USB Play-through

Residential Gateway (RG) Battery Backup REV B

Medical Computer Cart

USER S MANUAL HSC-24A

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

StorTrends 3400 Hardware Guide for Onsite Support

Important Safeguards

Home Solar Kit Owner s Manual. Model: HS

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Home Gateway. User s Installation Guide. In This Guide

BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Instructions & Safety Information Models A220-20D and A220-20L Version 2

HP UPS R1500 Generation 3

How To Use A Power Supply Unit (Upland)

Cambridge Electric Infared Fireplace User Manual

IMPORTANT SAFETY INSTRUCTIONS

User Manual (English)

User Manual. English. APC Smart-UPS RT. 8000/10000 VA Vac Tower/Rack-Mount 6U Uninterruptible Power Supply

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Evolution Digital HD Set-Top Box Important Safety Instructions

Transcription:

EKOS Cart Instructions for Use EKOS Corporation 11911 North Creek Parkway South Bothell, WA 98011 USA (425) 415-3100 (tel) (425) 415-3102 (fax) info@ekoscorp.com (e-mail) - 1-4913-002 REV E

Intended Use The EKOS System Cart is intended for use exclusively with EKOS Control Systems. Hazard Warnings TIPPING HAZARD - Do not tip the Cart more than 10 degrees. TIPPING HAZARD - Never operate the Cart without battery properly installed. EXPLOSION HAZARD Never store or operate the Cart in the presence of flammable gasses. EXPLOSION HAZARD Do not use spray cleaners while the battery is operating. ELECTRICAL HAZARD The battery does not require maintenance. There are no user-serviceable parts inside. Only qualified personnel should service the Battery. Proper Use Warnings Leave the Battery plugged into a wall outlet and charging except for mobile operation. The Cart is intended for use with an EKOS Control Unit. Do not connect any other devices to the Battery. Do not spill liquids on the Battery. Electrical failure may occur. Do not leave the Battery discharged for an extended period of time. It will suffer permanent damage. Do not plug the Battery into itself; this will damage the Battery. Do not block cooling fan vents on rear of Battery. Only connect the Battery plug to Hospital Grade wall sockets. Do not set heavy objects on the handle or Control Unit tray. Do not use extension cords. - 2-4913-002 REV E

Infusion Pump Mounts EKOS Control Unit Accessory Basket Battery Figure 1: EKOS System Cart Front Figure 2: Battery Rear - 3-4913-002 REV E

Description The EKOS System Cart (Fig 1 & 2) includes a shelf for mounting the EKOS Control Unit, a Battery, and a tray for holding cables and Instructions for Use. Two casters have locks. Up to two infusion pumps may be mounted in three different locations. The Battery can provide power to the EKOS Control Unit for up to an hour of operation. Directions for Stationary Use 1) Lock two front casters. 2) Plug the Battery into a power outlet. The BATTERY CHARGE LIGHT will be illuminated. 3) Plug the Control Unit into the Battery. 4) Press the POWER button for two seconds to Turn the Battery ON. (Alarm will beep once.) Directions for Mobile Use 5) Unlock two front casters. 6) Unplug the BATTERY from the power outlet and store the cable in the Accessory Basket. An alarm will sound (four beeps followed by a brief silence, repeating) indicating that the BATTERY is unplugged. This alarm can be silenced using the MUTE/TEST button. NOTE: If the alarm cannot be silenced using the MUTE/TEST button, a low Battery condition is indicated and the Battery must be charged before use. 7) After mobile use, plug the Battery into a power outlet. Keep the Battery plugged in at all times, except during mobile use, to keep the Battery fully charged. - 4-4913-002 REV E

Battery Control Buttons and Indicators POWER Button: To turn the BATTERY ON press and hold the POWER button for two seconds. The alarm will beep once. To turn the BATTERY OFF press and hold the POWER button for one second. The alarm will beep once. MUTE Button: Press to mute BATTERY alarms. POWER: Green light illuminates continuously when BATTERY is ON and plugged in. LIGHT flashes and an alarm sounds (4 short beeps followed by a pause) to indicate the BATTERY is operating. VOLTAGE CORRECTION: Green light illuminates continuously whenever BATTERY is automatically correcting high or low voltage inputs. BATTERY will emit a slight clicking noise. No action is required. OUTPUT LOAD LEVEL: Red LIGHT (continuous or flashing) - remove any devices other than the EKOS Control Unit that are attached to the Battery. If LIGHT remains red, plug the BATTERY into a hospital power outlet. BATTERY CHARGE: Red means Battery is beginning to charge; yellow means Battery is half charged; green indicates Battery is charged. Red light with continuous alarm indicates Battery is nearly discharged. Shut down is imminent. Plug into hospital power outlet immediately. BATTERY WARNING: Red light and intermittent alarm mean Battery needs to be recharged. Allow BATTERY to recharge continuously for 12 hours. If Light or Alarm continues, contact EKOS Corporation for service or replacement. - 5-4913-002 REV E

Cleaning Wipe down all surfaces with cleaning materials per standard hospital operating procedures. Extended Storage To store Battery, recharge once every 3 months for 12 hours. If Batteries discharge for an extended period of time, they will suffer permanent damage. Service Some indications that service is necessary for the Battery are: 1. A fully charged BATTERY will not operate the EKOS Control Unit for 1 hour of mobile use. 2. The Battery Charge or Battery Warning lights remain red after full charge. 3. Continuous alarms on a fully charged system which cannot be silenced by use of the MUTE button. Check that the BATTERY System s circuit breaker is not tripped. Circuit breaker If the problem continues, contact EKOS. A service technician will ask for the BATTERY model number, serial number and purchase date and will attempt to correct the problem over the phone. Battery Replacement Under normal conditions the Battery will last 3 to 6 years. Do not attempt to replace it. Call EKOS for repair, replacement parts and/or instructions. - 6-4913-002 REV E

SYSTEM OVERVIEW BATTERY SPECIFICATIONS Line isolation: Prevents shock to users and sensitive electronic equipment Overload protection: Resettable circuit breaker Battery recharge rate: 2-4 hours to 90% Best electrical service: 15A, 120V, 60 Hz Leakage current: Less than 300 microamps Typical battery lifespan: 3-6 years Operating Temperature: +32 to +104 F Storage Temperature: +5 to +122 F Relative Humidity: 0 to 95%, non-condensing Unit weight (lbs): 45.2 Material of construction: PVC Switches: 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions Front panel LEDs: battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning Alarms: Audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone) Cooling method: via rear-exit fan Input connection type: NEMA 5-15P Hospital Grade Input cord: 6 ft., 14 gauge Outlet type: Back panel grounding lug Certifications: NEMA 5-15R Hospital Grade output receptacles UL1778 (USA, Series AGSM1200PSR3HG), UL 60601-1, cul (Canada), FCC Class A (emissions). AC surge suppression conforms to IEEE 587 / ANSI C62.41 specifications EKOS Corporation 11911 North Creek Parkway South Bothell, WA 98011 USA (425) 415-3100 (tel) (425) 415-3102 (fax) (888) EKOS HELP (888) 356-7435 info@ekoscorp.com (e-mail) - 7-4913-002 REV E