Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card



Similar documents
Intel Atom Processor E3800 Product Family

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

USE OF FLOW NETWORK MODELING (FNM) FOR THE DESIGN OF AIR-COOLED SERVERS

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

STANDARD EXTRUDED HEAT SINKS

Temperature-Aware Design of Printed Circuit Boards

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

Thermal Management of Electronic Devices used in Automotive Safety A DoE approach

/12/$ IEEE 1488

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

Shrinking a power supply and the challenge to maintain high reliability.

Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems

Everline Module Application Note: Round LED Module Thermal Management

imaginit.com/autodeskcfd Scalable, robust fluid flow and thermal simulation solution

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Accurate Air Flow Measurement in Electronics Cooling

Thinking Outside the Box Server Design for Data Center Optimization

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS

NEC Micro Modular Server Introduction. NEC November 18,2014

RESPONSE TIME INDEX OF SPRINKLERS

Intel Core 2 Duo Mobile Processors on 45-nm process for Embedded Applications

Surface Mount Technology cooling for high volumes applications by: Cesare Capriz Aavid Thermalloy via XXV Aprile 32 Cadriano (BO) ITALY

Intel 875P Chipset. Thermal/Mechanical Design Guidelines For the Intel 82875P Memory Controller Hub (MCH) April Document Number:

FloEFD TM. Concurrent CFD for Creo Parametric.

Intel Quark SoC X1000

DirectFET TM - A Proprietary New Source Mounted Power Package for Board Mounted Power

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

Intel Desktop Board DG45FC

Accelerating Data Compression with Intel Multi-Core Processors

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

HUAWEI Tecal E6000 Blade Server

Reducing Data Center Energy Consumption

WANic 800 & or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

DESIGN AND SIMULATION OF LITHIUM- ION BATTERY THERMAL MANAGEMENT SYSTEM FOR MILD HYBRID VEHICLE APPLICATION

Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling

THERMAL ANALYSIS. Overview

Natural Convection. Buoyancy force

Using CFD for optimal thermal management and cooling design in data centers

Application Server Platform Architecture. IEI Application Server Platform for Communication Appliance

Intel Desktop Board DQ45CB

SOLIDWORKS SIMULATION GET DESIGN INSIGHTS TO DRIVE MARKET WINNING INNOVATION

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

The Advantages of Multi-Port Network Adapters in an SWsoft Virtual Environment

Intel Processors in Industrial Control and Automation Applications Top-to-bottom processing solutions from the enterprise to the factory floor

Flat, foldable cable.

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

Power Dissipation Considerations in High Precision Vishay Sfernice Thin Film Chips Resistors and Arrays (P, PRA etc.) (High Temperature Applications)

HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT

Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling

Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres

Deliver More Applications for More Users

Effect of Rack Server Population on Temperatures in Data Centers

Medical and Healthcare Embedded Computing Platforms

How To Calculate Thermal Resistance On A Pb (Plastipo)

Intel RAID SSD Cache Controller RCS25ZB040

2.1 The performance of bus air conditioning system is evaluated in the following operating conditions

Board Specification. Tesla C1060 Computing Processor Board. September 2008 BD _v03

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

Cisco UCS B-Series M2 Blade Servers

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Reliability of Air Moving Fans, and Their Impact on System Reliability. A White Paper from the Experts in Business-Critical Continuity TM

Application Note SigC667x-64 Cards Power and Thermal Evaluation

Easy-to-Use CFD for Electronics Design. Thermal Design in Half the Time

Application Server V240 Platform

How To Build A Cisco Uniden Computing System

Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge

CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems

LED HEATSINKS Spotlight / Tracklight HighBay / LowBay Reflector ring & Housing Customized Heatsinks

Performance Across the Generations: Processor and Interconnect Technologies

Router Architectures

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Thermal Management for Low Cost Consumer Products

The MAX5 Advantage: Clients Benefit running Microsoft SQL Server Data Warehouse (Workloads) on IBM BladeCenter HX5 with IBM MAX5.

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

How PCI Express Works (by Tracy V. Wilson)

Securing Computing Resources from USB Borne Viruses and Malware. White Paper

System Installation. 3-1 Socket 370 Celeron/Pentium-III Processor. Installing S370 CPU. Removing CPU. Configuring System Bus

High speed pattern streaming system based on AXIe s PCIe connectivity and synchronization mechanism

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

THE PSEUDO SINGLE ROW RADIATOR DESIGN

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Embedded PC Systems. DSMcomputer. Listen Advise Solve

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Cisco for SAP HANA Scale-Out Solution on Cisco UCS with NetApp Storage

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

Cisco MCS 7825-H2 Unified CallManager Appliance

Access Server Rack Cabinet Compatibility Guide

Structural and Thermal Fluid Simulation and CAD System Linking

Benefits of Cold Aisle Containment During Cooling Failure

Modeling Rack and Server Heat Capacity in a Physics Based Dynamic CFD Model of Data Centers. Sami Alkharabsheh, Bahgat Sammakia 10/28/2013

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Design Best Practices for Data Centers

Thermal Management of Datacenter

Application Note AN-1057

Integration of a fin experiment into the undergraduate heat transfer laboratory

Performance Comparison of Fujitsu PRIMERGY and PRIMEPOWER Servers

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

Transcription:

CASE STUDY Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card Challenge When GE Fanuc Intelligent Platforms, a leading provider of embedded computing solutions for a wide range of industries and applications, needed to determine the thermal characteristics of their new WANic 3860 Packet Processor, they turned to the experts at Advanced Thermal Solutions, Inc. (ATS). ATS is a leading electronics cooling provider which offers comprehensive thermal management analysis and design services tailored to help bring telecommunications, networking, embedded computing and other high performance electronic products to market faster, ensure their reliability and reduce development costs. The WANic 3860 Packet Processor is a high-performance 4-port Gigabit Ethernet PCI-X card which provides secure, high-speed connectivity and complex security processing with wire speed performance. It features the Cavium OCTEON 16 core 500 MHz CN3860-NSP (Network Services Processor), which needs to be kept at a junction temperature below 110 C to maintain reliable operation. R0_0409

A previous model, the WANic 3850, utilized an active heat sink for cooling the Cavium component. However, GE Intelligent Platforms design team wanted a complete and thorough thermal examination of the WANic 3860, so that a passive cooling solution could be used, offering much greater reliability, reductions in cost and implementation time. In response, ATS provided several thermal management analysis and design services for GE Fanuc Intelligent Platforms, including: 1. Thermal analysis of the PCI board design 2. CAD and Computational Fluid Dynamics (CFD) modeling, simulation and analysis 3. Rapid design and development of the prototype heat-sink 4. Wind tunnel and chassis testing and verification 1. Thermal Analysis ATS thermal management experts studied several key factors including volumetric flow rate, pressure drop and component temperature. The company s engineers started by researching and simulating the thermal characteristics of the Cavium OCTEON CN3860, DDR2 memory DIMM, and other critical components. By using this approach, analytical junction temperatures were produced for each device as well as an estimate of the airflow necessary to ensure proper cooling of the WANic card. It also reduced the number of CFD (computational fluid dynamics) iterations that needed to be performed, and validated those CFD findings. 2. CAD and CFD Modeling, Simulation and Analysis Based on the results of the thermal analysis, ATS engineers used SolidWorks 3D CAD software to produce a detailed model of the board assembly. Then they ran multiple airflow simulations, at various flow rates, using CFD software from CFDesign. The result was a detailed set of CFD images showing the airflow patterns and providing a temperature profile of the card. A CAD model of the card is shown in Figure 1. Figure 1. SolidWorks Model of the GE Fanuc WANic 3860 PCI Card.

Figure 2. SolidWorks Images of the ATS-725 maxiflow Heat Sink Along with its CFD Simulation and Prototype. 3. Rapid Prototype Design and Manufacture Using the data from the initial analytical and CFD studies, ATS designed a high-performance heat sink (ATS-725), based on the company s patented maxiflow flared fin architecture that, when installed, would adequately cool the Cavium CN3860 package and ensure proper performance of the WANic PCI card. ATS maxiflow heat sinks feature a low profile, spread fin array to maximize their surface area for more effective convection (air) cooling. In the case of the WANic PCI card, the ATS-725 heat sink was found to keep the junction temperature of Cavium CN3860 at or below acceptable levels with an airflow of 1.39 m/s (275 LFM) or greater within a PCI card slot, at an ambient air temperature of 55 C. The design team then had heat sink samples fabricated at ATS manufacturing facility in Norwood, MA, USA. As part of the design process, ATS tests heat sinks in its thermal fluids laboratory, using sophisticated equipment such as its CWT-100 series open-loop wind tunnel, to verify any analytical or computational simulation results. 4. Wind Tunnel Testing and Verification As part of the design process, ATS tests heat sinks in its thermal fluids laboratory, using sophisticated equipment such as its CWT-100 series open-loop wind tunnel, to verify any analytical or computational simulation results. When the ATS-725 was tested, elements in the open-loop wind tunnel were arranged to simulate the PCI slot conditions, thus validating CFD testing. Test findings also produced the heat sink s thermal resistance and pressure drop characteristics. The analytical design of the ATS-725 passive heat sink for cooling the Cavium CN3860 was the initial phase of the WANic card thermal characterization. Because of the complexity of the heat transfer from the Cavium component to the ambient, ATS performed further testing of the maxiflow heat sink installed on the WANic card, and inside an Intel SR2400 server chassis, under several test conditions. Thermocouples and ATS ATVS-2020, Automatic Temperature and Velocity Scanner, multi-channel, hot-wire anemometer system were used to measure case temperature as well as approach air velocity. Sample chassis and instruments are shown in Figure 3.

Figure 3. An Intel SR2400 Server Chassis (Left) and an ATS ATVS-2020 Automatic Temperature and Velocity Scanner (Right) Were Used to Test the ATS-725 Heat Sink Performance on a WANic 3860 Card. For one validation test, a sample WANic card was installed in the chassis and variable airflow. Component temperatures were recorded over a range of airflow levels to produce a thermal resistance graph. In a separate test, the WANic card was modeled in CAD and simulated with CFD. The PCB was modeled as a standard 12 layer board with bulk thermal properties as follows: a thermal conductivity of 85.66 W/m-K in the X and Y directions, thermal conductivity of 0.33 W/m-K in the Z direction, 432.54 kg/m3 density, and 837.00 J/kg-K specific heat. The results of these two testing methods showed close agreement, with an error of 2-13% from 0.5-3 m/s (100-600 LFM) air velocity. A final stage of testing included CFD simulation of the complete WANic card, including the ATS-725 heat sink. This simulation also showed close agreement with the chassis testing. CFD results showed a consistently higher thermal resistance of 2-13%, and this was mainly due to a lack of radiation heat transfer in the simulation. Once the base simulation was correlated with experimental results, future scenarios could be investigated within CFD to predict processor upgrade thermal performance. Figure 4 shows the CFD simulation and the final heat sink designed. Figure 4. CFD Simulation of the GE Fanuc Intelligent Platform s WANic Packet Processor PCI Card with the ATS-725 maxiflow Heat Sink Installed, Along Side a Sample Card.

Solution ATS Thermal Management Analysis & Design Services produced valuable analytical, computational and experimental data that allowed for a high-performance, optimized passive heat sink solution to be designed for the card s ideal operating conditions. Thermal Resistance ( C/W) 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 0 0.5 1 1.5 2 2.5 3 3.5 Air Velocity (m/s) CFD Simulation Chassis Testing Figure 5. The Results of CFD Simulations and Chassis Testing of the ATS 725 maxiflowtm Heat Sink. GE Fanuc Recommends and Airflow of at least 275 LFM if a Passive Heat Sink is Used 900,000 852,639 800,000 700,000 600,000 500,000 400,000 300,000 200,000 100,000 0 30,574 Mean Time Between Failure (Hours) Active HS with 12V Fan ATS-725 Passive maxiflow HS Figure 6. Comparison of Cooling Solutions for the GE Intelligent Platforms WANic 3860 Card In Terms of Mean Time Between Failures Not only did the ATS-725 maxiflow TM heat sink solution offer significant cost savings but it also provided 27 times the reliability of the active solution. As a result of the collaboration between GE Fanuc Intelligent Platforms design team and ATS thermal management experts, the company was able to quickly introduce the new card to the market with cost savings and increased reliability. Visit www.qats.com or call 781-769-2800 to learn more about ATS Thermal Management Analysis & Design Services.