EndoWorld GYN 37-1-E/11-2011. TROPHYscope CAMPO Compact Hysteroscope



Similar documents
Transvaginal Endoscopy TVE GYN /2015-E

GYN /2016-E HYSTEROMAT E.A.S.I. Endoscopic Automatic System for Irrigation

GYN /2015-E. GynTrainer. the virtual platform for diverse and risk-free training of gynecological diagnosis and therapy

HF Electrosurgery Unit AUTOCON II 80 UNITS /2014-E

Fiber Optic Light Cables

Implementation of hysteroscopy in an infertility clinic: The one-stop uterine diagnosis and treatment

A Guide to Hysteroscopy. Patient Education

Mobile Video Cystoscopy from KARL STORZ

HAND INSTRUMENTS. HiQ+ Monopolar Hand Instruments Needle Holders Suction and Irrigation Monopolar HF Electrodes. THE HiQ+ SERIES

Highlights Telepresence. Imaging Systems, Documentation, Illumination, Equipment Carts Edition, Quarter 1

Gynecology TRUCLEAR. Hysteroscopes/ Cytourethroscopes, Hysteroscopic Sheaths and Laparoscopes. Hysteroscopic Morcellator

C-MAC S Video Laryngoscope

Laparoscopic Obesity Surgery

VET /2016-E TELE PACK VET X LED. The Complete Mobile Endoscopic Video and Documentation System

67273 EN V40/14 NOUVAG AG, all rights reserved Subject to change. Laparoscopic Hysterectomy Morcellator

A Revolution in Transurethral Treatment Concepts

Treating heavy menstrual bleeding caused by fibroids or polyps

MyoSure Hysteroscopic Tissue Removal System MyoSure XL Tissue Removal Device Instructions for Use

CAVALLO/CAPPABIANCA Set

KARL STORZ SILVER SCOPE Series

Highlights Edition, Quarter 3. Navigation

Laparoscopy and Hysteroscopy

A potential treatment for your abnormal uterine bleeding

EndoWorld AN 9-6-E/ C-MAC. The new generation of KARL STORZ Video Laryngoscopes: BOEDEKER-DÖRGES Video Laryngoscopes. New! D-BLADE. New!

Visceral surgery with ultrasonic technology by Söring: quick and with minimal bleeding.

CHAPTER 10 Uterine Synechiae

POST MENOPAUSAL BLEEDING CHECKLIST. Ultrasound. Information folder given to patient. Booking form faxed/ ed

A report of 300 cases using vacuum aspiration for the termination of pregnancy

Office hysteroscopy, transvaginal ultrasound and endometrial histology: a comparison in infertile patients

MIN Set. Instruments for Minimally Invasive Neurosurgery. Aesculap Neurosurgery

MANUAL OF HYSTEROSCOPY DIAGNOSTIC, OPERATIVE AND OFFICE HYSTEROSCOPY

Out-patient hysteroscopy. Information for patients

Lecture 2 Advanced Hysteroscopic Surgery

The position of hysteroscopy in current fertility practice is under debate.

Varian Brachytherapy Applicators and Accessories

Outpatient hysteroscopy

Standard Operating Procedure

The forceps are available in addition to the standard models (s. catalogue of electrosurgical accessories).

Reproductive Health Group

Uterine fibroids (Leiomyoma)

Clinical Interruption of Pregnancy (Medical/Surgical Abortion)

Surgical scissors and forceps Product List

HEINE Veterinary ENT diagnostic instruments

ERBEJET 2. The versatility of waterjet surgery: ERBEJET 2 with hybrid instruments WATERJET SURGERY

Hemostasis Solutions Boston Scientific is committed to improving patient care in the management of gastrointestinal bleeding.

UROLOGIE UROLOGY.

Tracheal Stent System

INSTRUMENT & ACCESSORY CATALOG

VAAFT: Video-Assisted Anal Fistula Treatment

Treatment of Maxillary Sinusitis Using the SinuSys Vent-Os Sinus Dilation System

Abnormal Uterine Bleeding

Abnormal Uterine Bleeding FAQ Sheet

The following chapter is called The Role of Endoscopy, Laparoscopy, and Hysteroscopy in Infertility.

Zak³ad Doœwiadczalno - Produkcyjny Optoelektroniki OPTEC s.c. OPTEC. Since 1988 CHIRURGIA. optec.pl

TECHNO PACK T LED. Now with MULTIPOINT 3.0 measuring software! The Latest Generation of the TECHNO PACK Product Range

Manufactured by: ETHICON Women s Health & Urology A Division of ETHICON, INC. Somerville, NJ USA

Step-by-Step Insertion Instructions

Role of Hysteroscopy and Laparoscopy in Evaluation of Abnormal Uterine Bleeding

GYNAECOLOGY. Ahmed Mohamed Abbas*, Mohamed Khalaf*, Abd El-Aziz E. Tammam**, Ahmed H. Abdellah**, Ahmed Mwafy**. Introduction ABSTRACT

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

MOVIEtube CR. Cinematography Rig. Setup Camera Sony PDW-F3 (MTCR-P-10-01) Version / English

LASER INSTRUMENTATION

Hip Arthroscopy Product Guide

Instruction manual EAR SET 1 EAR SET 4

The Captivator II Snares are the first line of stiff and rounded snares available in multiple sizes with both a hot and cold snaring indication.

OUTPATIENT HYSTEROSCOPY SERVICES JASMINE SUITE

Coaxial Cable Products Guide. Connectivity for Business-Critical Continuity

Cost-Effectiveness of Office Hysteroscopy for Abnormal Uterine Bleeding

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Captivator II. Single-Use Snares

FIEGERT~ ENDDTECH "-----/ GYN

EXHIBIT C BOSTON SCIENTIFIC PRODUCTS AVAILABLE FOR NIH BRAIN INITIATIVE Page 1 of 9

Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations

Endoscope Optics. Chapter Introduction

STARLINN. Novacon Pioneers a New Telescope Profile. Here we have an absolutely new product all over the world! A new way of seeing!

Designed by Endoscopists, Refined by Nurses & Techs An Intuitive Endoscopic Electrosurgical Platform

Rack Installation Instructions

Hysteroscopy Findings in Failed IVF and its Influence on Pregnancy Outcome

Incubator with mechanical convection

Many roads lead to a perfect impression...

Hysteroscopy (Out Patient, Day Case or In Patient)

16/32 Channel 1U Rack Mount CCTV Power Supply

Making Wiring Easier Push-in Terminal Blocks for Modular Machine Designs

Office Visits. Breast

Zimmer DeNovo NT Natural Tissue Graft

Aspira* Peritoneal Drainage Catheter

BRUDER LAPAROSCOPY BRUDER 5 MM Ø LAPAROSCOPIC INSTRUMENTS BRUDER MULTI-FUNCTIONAL STYLE LAPAROSCOPIC INSTRUMENT

COUNTRYMAN E6 OMNIDIRECTIONAL EARSET MICROPHONE

Driver Pant 8 and antenna switcher Ant 8. User manual

Innovation for optimized outcomes

BOUGIES/DILATORS. Dilators

Magnetic Anchor for More Effective Endoscopic Mucosal Resection

EARLY PREGNANCY LOSS A Patient Guide to Treatment

Best Practice & Research Clinical Obstetrics and Gynaecology

Instruments and accessories

Diagnostic and Operative Hysteroscopy Joint RCOG/BSGE Meeting

Why Expanded Beam types are essential in military and other harsh environment applications

Transcription:

EndoWorld GYN 37-1-E/11-2011 TROPHYscope CAMPO Compact Hysteroscope

TROPHYscope CAMPO Compact Hysteroscope Foreword The new TROPHYSCOPE, CAMPO Compact Hysteroscope, is specially designed for office hysteroscopy in an ambulatory environment, offering the highest comfort to the patient and the physician. The TROPHYSCOPE is based on a 2 mm Hr rod lens telescope with integrated inflow channel. This design already permits a diagnostic hysteroscopy. The TROPHYSCOPE has a very thin outer diameter of only 2.9 mm which is very advantageous for the examination of infertility patients and nullipara, as well as postmenopausal patients. Dilation of the cervical canal is usually not necessary at all. Furthermore, it exhibits improved stability and flow characteristics. Additionally, the light transmission has been improved by augmenting the quantity of the light fibers in order to guarantee an excellent picture quality of the telescope even with its small diameter. This thin and compact hysteroscope does not require any assembling in its single-flow version. The specially designed instrument tip along with the comfortable length of the instrument provides easy instrument handling. It facilitates an atraumatic passage through the cervical canal into the uterine cavity and reduces the risk of traumatizing the endometrium. There is no risk that the view will be obscured by the sticking of tissue to the instrument tip. An innovative feature of this hysteroscope is that it can be loaded with an accessory sheath in an active and passive position. There are currently two accessory sheaths available: a continuous-flow sheath and an operating continuous-flow sheath with a 5 Fr. working channel.

2 3 In its passive position, the continuous-flow sheath will not enlarge the instrument s diameter for the diagnostic procedure, but can be activated if needed. With a simple push on the button and a movement distally, the cervix is gently dilated with the help of the sheath. The continuous-flow sheath or the operative sheath can be locked in the active position during the examination, thus providing supplementary functions such as continuous-flow or application of a semiflexible 5 Fr. instrument (operative sheath), without the need to remove the hysteroscope. Moreover, the operating sheath offers the opportunity to carry out minor operative interventions such as biopsies, polyp resection or septum dissection. The system will provide huge opportunities in the future to perform accessory activities like hysteroscopic guided embryo transfer or posthysteroscopic endometrial sampling using the outer sheath as a suction curette. For office use the compatibility of this instrument with a biodegradable high level disinfection agent like TRISTEL FUSE offers the possibility to reuse the instrument within a few minutes and makes the procedure accessible for every office gynecologist, ambulatory unit or IVF-center. Dr. Rudi Campo Medical Director LIFE Leuven, Belgium.

Special benefits of the TROPHYscope CAMPO Compact Hysteroscope Since the inflow channel has been combined with the 2 mm 30 Hr telescope, an improved stability can be provided permitting furthermore an extended working length of the hysteroscope. Thanks to the 2 mm rod lens Hr telescope and to the improved increased light transmission characteristics a brilliant picture quality is achieved. The thin outer diameter of only 2.9 mm of the TROPHYSCOPE, CAMPO Compact Hysteroscope, (without continuous-flow or operative sheath) makes an examination of the uterine cavity without dilation of the cervix easily possible. This is very advantageous especially for infertility patients. Thus it can be used without anesthesia. Gentle insertion into the cervical canal is facilitated due to the atraumatic tip and the specially shaped sheath of the hysteroscope. In order to have a continuous-flow and the possibility to carry out minor operative interventions simultaneously, an operating sheath is available which is applicable with the well-known 5 Fr. instruments. The TROPHYSCOPE, CAMPO Compact Hysteroscope, is compatible with the high level disinfectant TRISTEL FUSE which enables sterilization within a few minutes. This is especially ideal for office gynecologists. Innovative sliding mechanism of the accessory sheaths Passive position: the continuous-flow or operative sheath is positioned at the rear position of the TROPHYSCOPE (proximally). Active position: the continuous-flow or operative sheath is positioned at the front, the active position of the TROPHYSCOPE (distally).

4 5 Application of the continuous-flow sheath A diagnostic hysteroscopy can be carried out with the TROPHYSCOPE examining the uterine cavity with the continuous-flow sheath being positioned at the rear position. The distal end of the TROPHYSCOPE has an outer diameter of only 2.9 mm and a newly designed tip configuration makes a very atraumatic insertion possible. During the examination the outer sheath can be pushed forward into the active position guided by the telescope to create a continuous-flow to lower the discomfort or to enlarge the total instrument diameter in case of major fluid leakage through the cervix. It is not necessary to remove the instrument and reinsert it again. Even with the continuous-flow sheath being in the active position the TROPHYSCOPE is still very atraumatic with an outer diameter of only 3.7 mm.

Application of the operative sheath A diagnostic hysteroscopy can be carried out with the TROPHYSCOPE examining the uterine cavity with the operative sheath being positioned at the rear position. In its passive position this sheath will not enlarge the instrument diameter (2.9 mm) for the diagnostic procedure, but can be activated if needed. In case of bleeding or if pathologies are discovered during the examination, the sheath can be pushed forward sliding over the telescope until it locks into the active position. The dilation of the cervical canal is therefore progressive and less traumatic. Thanks to the integrated 5 Fr. working channel of the operative sheath there is the opportunity to carry out minor operative interventions such as septum dissection, polyp resection etc. With the operative sheath being positioned at the active position the TROPHYSCOPE exhibits an outer diameter of 4.4 mm.

6 7 Recommended Set 26008 BAC TROPHYscope CAMPO Compact Hysteroscope, Hr, 30, size 2.9 mm, length 24 cm, with irrigation connection, for use with continuous-flow sheath 26152 DA or operative sheath 26152 DB 26152 DA Continuous-Flow Sheath, size 3.7 mm, length 18 cm, with suction connection, for use with the TROPHYSCOPE 26008 BAC 26152 DB Operating Sheath, size 4.4 mm, length 16 cm, with working channel for semi-rigid 5 Fr. instruments, with suction connection, for use with the TROPHYSCOPE 26008 BAC 26159 SHW Scissors, pointed, single action jaws, semirigid, 5 Fr., length 34 cm 26159 UHW Biopsy and Grasping Forceps, double action jaws, semirigid, 5 Fr., length 34 cm 26159 BE Bipolar Dissection Electrode, semirigid, 5 Fr., length 36 cm 26159 GC GORDTS/CAMPO Bipolar Ball Electrode, semirigid, 5 Fr., length 36 cm 26159 H HESSELING Tenaculum Grasping Forceps, double action jaws, semirigid, 5 Fr., length 34 cm 26176 LE Bipolar High Frequency Cord to KARL STORZ Coagulator 26021 B/C/D, 860021 B/C/D, 27810 B/C/D, 28810 B/C/D AUTOCON system (50, 200, 350) and Erbe-Coagulator, T- and ICC-series, length 300 cm 495 NT Fiber Optic Light Cable, size 2.5 mm, length 180 cm

www.karlstorz.com EndoWorld KARL STORZ GmbH & Co. KG Mittelstraße 8, 78532 Tuttlingen, Germany Postbox 230, 78503 Tuttlingen, Germany Phone: +49 (0)7461 708-0 Fax: +49 (0)7461 708-105 E-Mail: info@karlstorz.de www.karlstorz.com KARL STORZ Endoscopy-America, Inc. 2151 East Grand Avenue El Segundo, CA 90245-5017, USA Phone: +1 424 218-8100 Phone toll free: 800 421-0837 (US only) Fax: +1 424 218-8525 Fax toll free: 800 321-1304 (US only) E-Mail: info@ksea.com EW GYN 37-1-E/11-2011