PT/EQA STANDARDS AND GUIDELINES: QUALITY AND RELIABILITY OF TEST ITEMS

Similar documents
General and statistical principles for certification of RM ISO Guide 35 and Guide 34

Certifying Reference Materials to ISO Guide 34

Reference Materials for Environmental Performance Testing Dr Steve Wood Head of Regulatory and Legislative Services. ISPRA 25 June 2009

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

Methods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

Proficiency testing schemes on determination of radioactivity in food and environmental samples organized by the NAEA, Poland

Performance and advantages of qnmr measurements

Interlaboratory studies

There is a need for a coordinating role by the Commission supported by the Framework programme, to facilitate and harmonise those developments.

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

IAEA-TECDOC Development and use of reference materials and quality control materials

Control Charts and Trend Analysis for ISO Speakers: New York State Food Laboratory s Quality Assurance Team

1. PURPOSE To provide a written procedure for laboratory proficiency testing requirements and reporting.

ISO and SANAS guidelines for use of reference materials and PT scheme participation Shadrack Phophi

Validation of measurement procedures

Training Programme. Laboratory Quality Manager and Laboratory Assessor November Vienna, Austria

Guide to Method Validation for Quantitative Analysis in Chemical Testing Laboratories

NVLAP Assessor Training. Assessor Qualification & Training Requirements

OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

NABL NATIONAL ACCREDITATION

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

R103 - GENERAL REQUIREMENTS: PROFICIENCY TESTING FOR ISO/IEC LABORATORIES

The age of competence: an update on the international laboratory accreditation scene for veterinary testing laboratories

USE OF REFERENCE MATERIALS IN THE LABORATORY

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

Procedure for Equipment Calibration and Maintenance

SHORT-TERM STABILITY TEST FOR URANIUM SOIL CANDIDATE A REFERENCE MATERIAL

The Fitness for Purpose of Analytical Methods. A Laboratory Guide to Method Validation and Related Topics

List of EA Publications. And International. Documents

TRACEABILITY. Commercially available single-element solutions are used. of Single-Element Calibration Solutions

RULES FOR THE PARTICIPATION IN INTER- LABORATORY COMPARISONS AND PROFICIENCY TESTING SCHEMES

Regional Environmental Protection Agency- Veneto Region LABORATORY REGIONAL DEPARTMENT

P07 CALA Application of Requirements in ISO/IEC 17025:2005 Revision 3.4 April 9, 2014

QA/QC. Standard methods in field. QA/QC in the field. QA/QC in analysis

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

SUS. Company Profile. Ulrich Nell, Feldstr.23, D Oberhausen, Tel. 0049(0)208/ Fax 0049(0)208/658536

Stimuli to the Revision Process

Definition of Minimum Performance Requirements for Analytical Methods of GMO Testing European Network of GMO Laboratories (ENGL)

Validation and Calibration. Definitions and Terminology

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

Selection, Use and Interpretation of Proficiency Testing (PT) Schemes

Preparation of Reference Materials for Analytical Quality Control in the Water Laboratories

Guidelines on the Reporting of Compliance with Specification

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

DMA-1 Direct Mercury Analyzer

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

THE INTERNATIONAL HARMONIZED PROTOCOL FOR THE PROFICIENCY TESTING OF ANALYTICAL CHEMISTRY LABORATORIES

ALACC Frequently Asked Questions (FAQs)

R221 - Specific Requirements: Forensic

International Laboratory Accreditation Cooperation. Laboratory Accreditation or ISO 9001 Certification? global trust. Testing Calibration Inspection

Proficiency Testing In A Global Analytical Environment Benefits & Challenges. AOAC September 2007

Overview of ISO for 'Biologicals'

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials

Accreditation according to ISO/IEC in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment

EffiValidation 3.0 software basic training module

EUROLAB 25 years. The role of metrology and testing to characterize materials and products. EUROLAB 25th Anniversary Seminar

DECISION LIMITS FOR THE CONFIRMATORY QUANTIFICATION OF THRESHOLD SUBSTANCES

QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES. October 2008 Revision 08

MANAGEMENT REVIEW FOR LABORATORIES AND INSPECTION BODIES

To avoid potential inspection

Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites

Terms concerned with internal quality control procedures

OLIVÉR BÁNHIDI 1. Introduction

High Level Importance: ISO Microbiology compliance

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Observations on the determination of gold in gold alloys cupellation method (Fire Assay)

How do I gain confidence in an Inspection Body? Do they need ISO 9001 certification or ISO/IEC accreditation?

ISO/IEC ACCREDITATION REQUIREMENTS FOR CALIBRATION LABORATORIES

A commitment to quality and continuous improvement

Federal Institute for Materials Research and Testing

Basic Steps to Establish ISO/IEC Compliant Testing Laboratories

Contents. Abstract...i. Committee Membership... iii. Foreword... vii. 1 Scope...1

DHI DANETV Test Centre Quality Manual

4.2 Bias, Standards and Standardization

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

EA-4/18 - guidance on the level and frequency of proficiency testing participation. Guidance on the level

MILESTONE H E L P I N G C H E M I S T S

How to Verify Performance Specifications

DATA FOR PUBLIC HEALTH DECISION MAKING

Performance Standard for Organisations Undertaking Radioanalytical Testing of Environmental and Waste Waters. Environment Agency July 2015 Version 2

American Association for Laboratory Accreditation

TEST REPORT: SIEVERS M-SERIES PERFORMANCE SPECIFICATIONS

LAB 37 Edition 3 June 2013

PTA proficiency testing for metal testing laboratories

Quality Assurance/Quality Control in Acid Deposition Monitoring

CERTIFICATION REPORT

ISO How to Meet. Requirements for Method Verification. Prepared by:

Lifecycle Management of Analytical Procedures; What is it all about? Jane Weitzel Independent Consultant

Appendix H: Probability of Detection (POD) as a Statistical Model for the Validation of Qualitative Methods

Transcription:

PT/EQA STANDARDS AND GUIDELINES: QUALITY AND RELIABILITY OF TEST ITEMS Maria Belli Istituto Superiore per la Protezione e la Ricerca Ambientale (former APAT)

ISPRA activities production and characterization of matrix reference materials methods development and harmonization organization of Proficiency testing organization of collaborative studies for method validation

Test material/test item IUPAC The International Harmonized Protocol for the proficiency testing of (chemical) Analytical Laboratories - 1993 does not define specifically the Test materials, but reports RM and CRM definitions as given by ISO REMCO IUPAC The International Harmonized Protocol for the proficiency testing of (chemical) Analytical Laboratories 2006 cross-refers to ISO standard definitions. It is given a definition for Distribution unit a packaged portion of the test material that is sent to participant laboratories

Test Item material or artefact presented to the participating laboratory for the purpose of proficiency testing ISO Guide 43-1:1997 a sample, product, artefact, piece of equipment or measurement standard sent to one or more participants in a proficiency testing scheme ILAC G13:2007

Test Item sample, product, artefact, reference material, piece of equipment, measurement standard or data set provided to one or more participants, or submitted by participants, in a proficiency testing round ISO-IEC CD 17043: March 2008

Test item in analytical chemistry RM family (Measurement Standards - ISO/IEC guide 99) in-house RMs, RMs QCMs, PCMs CRMs, CALs H. Emons et. al., 2006, AQUAL 10, 576 Certified reference materials, calibrators

Quality of test items Matrix matching Homogeneity Stability Assigned values

Test item - Matrix matching 1993 Pure & Appl. Chem. Vol.65 n 9 (IUPAC Protocol) Qualitative definition 2008 ISO/IEC CD 17043

Matrix Matching Matrix proficiency test items should, were practicable, have the same or nearly the same matrix as routine test materials in order to simulate the measurement process as close as possible ILAC-G13:2007

Commutability ISO Guide 99 gives the definition of commutability of reference material ISO Dguide 34 reports a method to assess commutability of reference material: If the ratio between the results on reference material with 2 measurement procedures is the same as the ratio for routine samples, the reference material is commutable

Commutability ARPA FVG (ng/m3) 7 5 3 PAH in PM10 Benzo[a]pyrene (ng/m3) Procedures CRM ratio GC-MS/HPLC BCR 535 sediment GC-MS/HPLC BCR088 sludge 1.6 1.3 GC-MS/HPLC NIST1650b 0.6 1-1 y=0.7409x-0.2048 1 3 5 7 9 ISPRA (ng/m3) Procedures ratio GC-MS/HPLC 1.7±0.2

Homogeneity APAT RM014 - Ni between bottles homogeneity Homogeneity study results are affected by: measurement repeatability between bottles variability

Homogeneity Study Standards and Guidelines requirements Standards/Guidelines IUPAC Harm. Protocol (1993) ISO Guide 43-1:1997 ISO 13528:2005 Statistical methods in PT IUPAC Harm. Protocol (2006) ILAC G13:08/2007 How* 10 test items - 2 replicates ANOVA s bb /σ PT <0.3 Cross reference to IUPAC (1993) 10 test items - 2 replicates s bb /σ PT <0.3 10 test items - 2 replicates σ 2 samp <F 1 0.3σ2 PT +F 2 s2 an ANOVA to obtain σ 2 samp e s2 an Recommendation σ an /σ PT <0.5 Where appropriate * Measurements in repeatability conditions

Homogeneity Study Standards and Guidelines requirements Standards/Guidelines ISO/IEC CD 17043:2008 Conformity assessment General requirement for PT ISO Guide 35:2006 RM- General and Statistical principles for certification ISO DGuide 34:2008 General requirements for the competence of RM producers ISO CD Guide 80:2008 Guidance for production of RM for precision control (PCMs) How* As above, but cross reference to ISO 13528 IUPAC (2006), ISO Guide 34 and ISO Guide 35 10 or more test items 3 replicates - ANOVA to assess the uncertainty contribution for residual heterogeneity Always RM producers shall carry out homogeneity study in compliance with ISO 17025 10 test items 2 replicates ANOVA to assess homogeneity between bottles *measurements in repeatability conditions are always required

APAT RM014 Ni homogeneity Before the PT ISO Guide 35:2006 400 After the PT APAT - RM014 - Nichel 71 Valore di riferimento : 256 ± 8 mg/kg Incertezza estesa con k=2 HF+HCl+HNO3 HNO3+HF HCl+HNO3+H2O2/HClO4 HCl+HNO3 HNO3 HNO3+H2O2/HClO4 11 u bb =1.2 µg/g mg/kg 300 200 6 59 52 7 46 144812 63 67 31 68 4 4935 58 37 2 72 1 57 253 7430 55 3242 54 66 3 6170 28602134562462 3327 39 9 36 51 4717 73 65 8 26 64 22 75 5 20 20 11 20 41 29 50 100 40 13 0 Laboratorio σ PT =31.8 µg/g U bb <9.5 µg/g ISO 13528:2005

Stability Stability study results are affected by: measurement repeatability between bottles variability

Stability Study Standards and Guidelines requirements Standards/Guidelines IUPAC Harm. Protocol (1993) ISO Guide 43-1:1997 ISO 13528:2005 Statistical methods in PT IUPAC Harm. Protocol (2006) ILAC G13:08/2007 How* Stability of the matrix and analytes must be determined Where possible the coordinator should provide evidence of stability of the test items during the PT Test items of the hom. test 3 2 replicates measured at the end of PT x mh -y ms 0.3σ PT Isochronous stability study for the PT period Where appropriate * Measurements in repeatability conditions

Stability Study Standards and Standards/Guidelines ISO/IEC CD 17043:2008 Conformity assessment General requirement for PT ISO Guide 35:2006 RM- General and Statistical principles for certification Guidelines requirements How* As above, but cross reference to ISO 13528 IUPAC (2006), ISO Guide 34 and ISO Guide 35 Short term stability by isochronous; long term stability by classical method ISO DGuide 34:2008 General requirements for the competence of RM producers ISO CD Guide 80:2008 Guidance for production of RM for precision control (PCMs) Always RM producers shall carry out stability study in compliance with ISO 17025 isochronous method * Measurements in repeatability conditions

APAT RM014 stability Isochronous method 3 months Effects at +20 C Reference group at 18 C Measurements under repeatability condition By Linear Regression b n t s b 1 0,95; 2 b 1 = slope; s(b 1 ) = slope uncertainty; t 0,95 = t-student. ( 1 )

Assigned values All standards and guidelines agree on methods to determine the assigned values and their associated uncertainties: Reference values Consensus from participants Consensus from expert laboratories By formulation

Conclusions Production of test items is not an easy activity Laboratories in charge for their preparation shall demonstrate competence in the measurement of properties being determined Is the ISO 17025 accreditation enough for test items production?