Technical & Production information. Updated 13.03.2015 Venue Address: Conservatoriumplein Kortrijk (near Station Kortrijk) For Busses/Nightliners we need to reserve parking space. Please advance your parking situation with the production manager at least a week before the show. Office Address: Muziekcentrum Track* Conservatoriumplein 1 8500 Kortrijk T. +32.56.370.644 F. +32.56.372.644 E. info@dekreun.be Web: www.dekreun.be Contact Information: Production Manager: Mich Decruyenaere T. +32.56.370.644 M. +32.486.659.711 E. mich@dekreun.be Sound/Lights/Video: Hein Devos M. +32.498.124.222 E. hein@dekreun.be Venue Capacity: 600 Main Hall (incl. Balcony, Foyer) 250 Main Hall Seated (Rental seats.) 800 Full capacity (only for Parties, incl. outdoor space) 90 Roof Top 120 Foyer Only +47
Stage: STAGE SIZE: 8,60 meters wide x 5,5 meters deep HEIGHT: 0,80 meters CLEARANCE: 6 meters FLYING FACILITIES: 3 x manual flying loads: 250kg / Speakers are also flown. ELECTRIC POWER: lights 125A, 3 x 380 volts + neutral + earth sound 32A, 3 x 380 volts + neutral + earth backline 16 amps. Sound: Line-Array Speakers : 8x Martin Audio W8LM (2 balcony) + 2x Martin Audio W8LMD (downfill) Sub Cabinets: 4x Martin Audio WS218X Sub 2x18 (Front loaded) Amps: 2 x Crest CA18 (2x1800W) (Lo+Top) + 1 x Powersoft (2 x 3600W on 2ohm) K6 Speaker Management: XTA 448 processing FOH Console: Midas Verona 400TP 32CH Mono / 8 Stereo / 8 Bus / 8 Aux. Outboard: 8 x Comp BSS DPR404 4 x Gate BSS DPR 504 APEX GX-230 30 bands graph EQ TC D-Two delay TC M 2000 + M 4000 Yamaha SPX 2000 Tascam CD/MD player Monitoring: 8 x 2-way wedges, 1 Drumfill. 1 x powersoft M50Q (1250W/ch) + 2 x amps Crest CA9 (900W) 6 x XTA 30 bands graph EQ Microphones Dynamic Audix OM7 (1) Audix OM5 (2) Electrovoice RE20 (1) Audio Technica ATM4041 (3) Audix VX-5 (1) Shure Bèta 52 (1) Shure SM57 (5) Shure SM58 (3) Sennheiser MD421 (1) Sennheiser E604 (3) Sennheiser E606 (1) Beyerdynamic M88 (1) D.I. s Radial J48 active D.I. (8) Radial JDI passive stereo D.I. (1) Sound Foyer: In the Foyer we have a High Power 4x Martin Audio 3-Way 12 speaker system + 2 x 15 Sub cabinets. Powered by Powersoft Digam L series amplifiers. Sound Lounge: The artist Lounge also has a speaker system where you can choose between your ipod, the local classical radio or even the main hall.
Lights: Controls: 1 x Chamsys MQ100 Expert + Extra Wing - 2 DMX-outputs (+ 2 spare to stage) Front Lights: 6x PAR64 MFL + 4x PAR WFL with barndoors + 4x PAR64 MFL from balcony Stagelight: 3 Trusses on trolleys with manual chain hoists. 6 x PR Lighting PR XL250 18Ch mode 8x LED Par WFL RGBW + 4x LED Par NAR RGB. 12 x Showtec Active Sunstrip Blinder (750W). 4x 6-BAR PAR 64 CP61 + 10x PAR 64 CP61 + 10x Floorcan PAR 64 4x Audience blinder 2-Lite 36CH dimmer for rigged stage light - 12CH dimmer for floorlights 1x Look Unique 2.1 Hazer Extra Power connections on stage (upstage): Stage Right: 1x Cee 32A + 2x Cee 16A Stage Left: 1x Cee 63A + 1x Cee 32A + 2x Cee 16A 2 DMX boosters 3P + 5P XLR Do not hesitate to contact us for a recent light plot. Video Capturing / Audio Recording: De Kreun captures all concerts on HD solid state camera s. We have 3 camera s at our disposal, all are operated by our personnel. We use those images to stream parts of each concert on our website, of course with permission of the artist. As a bonus you can obtain the raw footage of the 3 camera positions for free, in uncompressed HD, subject to have a portable storage with you so we can transfer the files (files are approx. 30Gb in total for video), or we can send a compressed compilation of the footage afterwards. Video Equipment: 3 x PMWEX1R XDCAM EX Full HD Memory Camcorders. Panasonic AWs Live Switcher. Blackmagic Multibridge Pro + Extreme. Contact Video Recording: pieter@dekreun.be Multitrack Audio Recording Equipment: 32 Channels Recording Apogee Symphony I/O + AD16X Converter. Mac Pro. Radial Passive Mic Splitters. Several additional Mic Pre s: API/Neve/Universal Audio. Ambience Microphones (DPA)+ Shotgun microphones. Additional Studio Mics (Schoeps, Royer, Mojave, Heil Sound, Josephson,...) on demand. Contact for Mutitrack Audio Recording: hein@dekreun.be Video Playback / Projections: Please inform us in advance if projections are needed. Our projections will be 16:9 due to the width of our screen. Screen width will be around 7m. Height approx. 4m. Standard Timing: Get in time: please advise exact arrival time to venue production manager (4 pm) Doors: 8 pm Support on Stage: 8.20 pm Main Artist on stage: 9.20 pm (9.00 PM if no support) Curfew: 11.30 PM Wifi / Internet: Free Wifi network available in Artist lounge/kitchen area and in Foyer. There is also a fully patchable FTP network available thru the whole building. Non-Smoking policy: Smoking is strictly forbidden in all areas of the venue! This includes the backstage area and Artist lounge. For artists there is the possibility to smoke on the roof top.
Additional Information (Production): Standard timing : Get in + load in headlining act : 16.00 pm Soundcheck headlining act : 16.30-17.30 pm Get in support act : 17.00 pm Soundcheck support act : 18.00-19.00 pm Doors : 20.00 pm Support on Stage: 8.30 pm Headlining act on stage: 9.30 pm (9.00 pm if no support) Curfew: 11.00 pm Get in time: please advise exact arrival time to venue production manager if it does not match the standard timing. We try to maintain a 11.00 pm curfew as people who come by public transport are able to get trains back to their destinations. Backstage: There is only on backstage area in the venue. The backstage is equipped with a kitchen, shower and WIFI (please ask the production manager as for passwords). Standard, catering is served in the backstage area. Food is prepared fresh and with respect for local products and suppliers If you like what u have eaten, thank the chef! ;) Sound restriction : Belgian sound restriction legislation from 01/01/2013 onwards : max soundlevel at FOH position: 100 dba Leq 60 minutes and 102dbA Leq 15 minutes. These restrictions can (and will) be checked by official city services at any moment. Violations of this legislation might cause us to loose our licence, which would be quite disastrous for us aswell as for the bands playing here. The promotor, the production manager or the local sound engineer has the right to intervene when bands do not respect these restrictions. We do hope u understand. Thanks a lot.
FloorPlan First Floor/ Main Hall Second Floor / Balcony Rooftop
Directions to the venue:. From Ghent/NL/DE: Take E17 exit2 (Hoog-Kortrijk) Keep right at the fork. Follow the signs: Kortrijk-Centrum / Panorama. Continue on the N323 (Condédreef), at the third red lights, you turn right onto the N43 (Aalbeeksesteenweg). Go straight at the roundabout. Go right at Conservatoriumplein and keep right. After 200m you will see the venue on your left side. From Lille/FR: Take E17 exit2 (Kortrijk Zuid) and follow signs for R8. Keep right at the fork. Follow the signs: Kortrijk-Centrum / Panorama. Continue on the N323 (Condédreef), at the third red lights, you turn right onto the N43 (Aalbeeksesteenweg). Go straight at the roundabout. Go right at Conservatoriumplein and keep right. After 200m you will see the venue on your left side.