WAVELET WATER QUALITY MONITORING KIT

Similar documents
FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

! WARNING. Before using product, read and understand instructions.

SunMaxx Solar Filling Station Operating Instructions

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Networkfleet 3500 Product Line Installation Guide

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Submersion/Insertion Toroidal Sensor

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Toroidal Conductivity Sensor

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

PCS300 Universal IP Reporting Module V1.0

Chapter2. Installation

Fiberstars Lighted Laminar Flow Fountain Installation Manual

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

AZEK Rail Install Guide

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

Open Channel Diffusers

RadianceRail Installation Guide

INSTALLATION INSTRUCTIONS BL-8704

the stainless steel water-heater for your woodstove USER S MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

INSTALLATION INSTRUCTIONS MK-8704

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Please keep this manual for f uture reference.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

with installation dynafact boost GAUGE this manual is for use with systems

ENAiKOON ultrasonic fuel-level sensor

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

MAC FAUCETS. Owner s Manual. Models: FA444

Installation Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Installation Instructions

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

Portable Air Conditioner

FG MOISTURE MONITOR Installation & Operation Manual

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

XL PREMIUM OIL COOLER KIT

GEET Fuel Processor Plans

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Back-Up Camera Installation Guide

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

SECURITY SYSTEM SMART SIREN KIT

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

1998½-2007 Dodge Ram 5.9L Cummins

Morrison Bros. Co. General Product Specifications

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Select Radiators Installation Guide

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

SECTION DUCTILE IRON PIPE AND FITTINGS

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Installer s Guide 18-AH39D1-13

2-Way Wireless Indoor Siren Installation Guide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Ocean Engineering Technical Data Sheet Stuffing Tubes

Guidelines for Earthquake Bracing of Residential Water Heaters

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Submersion/Insertion Toroidal Sensor

SMS Alarm. User Manual

Air Sleeve Maintenance

Complete System Shelter

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Installation Guide. GPS vehicle security, recovery and location awareness

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

EZ-Steer Assisted Steering System

Your safety and the safety of others are very important.

Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit

IMPORTANT DOCUMENTATION DO NOT DISCARD!

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Advantium 2 Plus Alarm

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Installation Instructions

Bathroom Installation Guide

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Transcription:

AYYEKA Rethink Water Monitoring WAVELET WATER QUALITY MONITORING KIT ON OFF QUICK START GUIDE AYYEKA

IMPORTANT! Use with pressure applications up to 145 PSI. Contact AYYEKA SUPPORT center for technical support at +1 (310) 876-8040. ALWAYS COORDINATE Wavelet Water Quality Monitoring Kit installation with the local water company before starting installation works, which should be completed by trained and authorized personnel. The WARRANTY offered by Ayyeka covers only Ayyeka supplied hardware and software for the duration of the warranty period as per the warranty terms and conditions.! AYYEKA IS NOT LIABLE for damage or injury as a result of handling, installation or maintenance of its supplied systems. 2G cellular network signal. DO NOT THROW AWAY away the Wavelet Water Quality Monitoring Kit, as it contains a lithium battery. Please dispose of properly. 1

SITE REQUIREMENTS & PREPARATION 1. Required site conditions: Minimum pipe diameter of 4 inches. Chlorinated drinking water in steel pipes. 0 145 psi is the operational pressure range. Maximum peak pressure is 435 psi. Water temperature range of 32 104 F. Minimum water velocity of 0.1 ft/sec. 2G cellular network signal. Sensor must be wet before being connected to the Wavelet. If the sensor is installed in intermittent water flow (turning on/off), its lifetime will be drastically decreased. 2

2. Prepare the site: SITE PREPARATION Prepare 2 NPT ball valve that is fixed perpendicular to the pipe surface and 45 to the ground. The maximum height from the interior of the pipe to the top of the ball valve is 6 inches. Ball Valve 90 45 Max. 6 Height To avoid turbulence and air bubbles, install ball valve as close to the middle of the pipe span and as far from pipe bends or equipment as possible. pump After fixing the ball valve to the pipe, ensure that the internal diameter of the hole punched for installation of the sensor is at least 1.7 inches. 1.7 diameter for insertion of water quality sensor 2 ball valve 4 diameter pipe 3

GETTING STARTED! Pipe Wrench 1x Bucket 1x Thread Seal Tape 1x Wavelet Water Quality Monitoring Kit 1 Sensor Cable 2 Water Quality Sensor 1x 1x 3 Wavelet Device 4 Gasket 1x 1x 5 Pipe Fitting 6 Zip Ties, Screws, and Anchors 1x 4 2x 4x 4x

NOTE: Special Installation Locations Weak Cellular Service Locations: If the Wavelet is installed in an area with weak cellular reception, activate the Wavelet and place in the intended intallation location with closed doors/access hatch. Log into home.ayyeka.com to ensure that GSM signal has been recently updated in the last few minutes. Underground/Indoor Wavelet Installations: Before installation, activate the GPS outside by turning on the Wavelet (see step 10). Wait for at least 8 minutes, then log in to the user interface at home.ayyeka.com to confirm updated location on the map. 5

WATER QUALITY SENSOR PREPARATION 1 Place tip of sensor in water for 30 minutes prior to installation.! CAUTION: Sensor should never be connected to the Wavelet device while dry. Do not yet connect the sensor to the Wavelet device. Only connect once the sensor is wet and installed in the pipe. 6

2 Choose proper installation configuration and location, taking into account cable length. Pipe Mounted Wall Mounted AYYEKA AYYEKA Do Not Install Upside Down AYYEKA 7

ON OFF 3 Wrap thread seal tape onto the pipe fitting, and screw it tightly into the valve with the pipe wrench. 4 Put the gasket onto the neck of the sensor. 8

ON OFF 5 While the valve is closed, thread the sensor into the pipe fitting up to ¼ BELOW the white stripe marking on the sensor.! CAUTION: Be careful not to apply too much force with the wrench. Going beyond the bottom of the white line will irreversibly BREAK the sensor. 1/4 clearance below white stripe 9

6 Open valve completely. Water will spray, which can be mitigated by holding a towel around the base of the sensor connection to the pipe fitting. ON OFF 7 Thread the sensor all the way until the gasket is sealed to prevent water leakage. ON OFF 10

WAVELET ACTIVATION 8 Connect cable to the Wavelet. Screw until tightly fastened. 9 Remove cap from top of sensor. Connect opposite end of cable to the sensor. B A ON OFF 11

10 Remove screws to open the back panel of the Wavelet device. Activate the Wavelet by sliding the switch to the ON position. Wavelet will then initiate a 20 minute online test mode. OFF ON 11 Access the Ayyeka user interface at home.ayyeka.com using your log-in credentials. Expect data to appear between 10-20 minutes after the online test mode is complete. 12

Water Quality Kit Water Quality Kit ppm ppm 57.49 psi 57.49 psi minutes ago minutes ago 3 ago minutes ago 85.8 F minutes ago minutes ago Water Quality Kit Water Quality Kit 57.49 psi 85.8 F ppm ppm 24 hours ago 24 hours 24 ago hours ago 24 hours ago 24 ago 24 24 12 The screen display should resemble the following: Water Quality Kit Water Quality Kit Water Quality Kit Water Quality Kit ppm ago ppm ppm minutes ago ppm 24 hours ago minutes ago 24 hours 24 ago hours ago 3 24 hours ago ago 24 ago 57.49 psi ago 57.49 psi 24 85.8 57.49 Fpsi ago 85.8 F 24 If Wavelet is transmitting properly, you have completed the installation successfully and can begin collecting and viewing your data! If data does not transmit properly, change the Wavelet installation location and activate again. If the problem persists, contact support@ayyeka.com or +1 (310) 876-8040 for assistance. 13

13 Screw the back panel of the Wavelet back on to the device according to the numbering scheme. Then, secure the Wavelet to its location. 4x 4x Wall Mounted 2x Pipe Mounted Your Wavelet Water Quality Kit is now successfully installed! 14

AYYEKA QUESTIONS? www.ayyeka.com support@ayyeka.com +1 (310) 876-8040