Reference Manual. Pressure/Temperature Compensated Flow (P_PTComp) Version 3.1



Similar documents
Logix5000 Controllers Import/Export Project Components

Stratix 5700 Switch Configuration

Logix5000 Controllers Nonvolatile Memory Card

MicroLogix 1100 Embedded Web Server

Stratix 5700 Network Address Translation. Quick Start

Logix5000 Controllers Function Block Diagram

Logix5000 Controllers Import/Export Project Components Programming Manual. Programming Manual

Logix5000 Controllers Security

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

ControlNet Standard and High-flex Coax Cable

Hard Disk Drive (HDD)

FactoryTalk ViewPoint Quick Start Guide

Safety Function: Door Monitoring

User Manual. DeviceNet Network Configuration

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Logix5000 Controllers Security

Programming Manual Catalog Numbers 1756 ControlLogix, 1769 CompactLogix, 1789 SoftLogix, 1794 FlexLogix, PowerFlex 700S with DriveLogix

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Logix5000 Controllers Add On Instructions

CompactLogix Power Supplies Specifications

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

Logix5000 Controllers Nonvolatile Memory Card

Product Compatibility and Download Center

SHORT TRAINING COURSES

Drive Software Wizards Version 3.4

Application Technique. EtherNet/IP Socket Interface

Bimetallic Overload Relay Specifications

USB-to-Data Highway Plus Cable

Universal Serial Bus (USB) to DH-485 Interface Converter

How To Build A Rockwell Library Of Process Objects

Legacy PanelView to PanelView Plus 6 Catalog Number Conversions

DriveTools SP v5.04 Software Patch

Logix5000 Controllers I/O and Tag Data

Time Recorder Extension Module for the Dynamix 2500 Data Collector

Fiber Optic Cable Installation

Micro800 Programmable Controllers: Getting Started with CIP Client Messaging

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

1756 ControlLogix Chassis Specifications

HP UPS R1500 Generation 3

PlantPAx Process Automation System

Logix5000 Controllers Major, Minor, and I/O Faults

Parameter Settings for PowerFlex Drives Using Sine Wave Filters, dv/dt Filters, and Adjustable Voltage

High Availability and Safety solutions for Critical Processes

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PanelView Plus to PanelView Plus 6 Catalog Number Conversions

Thermal Dispersion Mass Flow

Reference Manual. Rockwell Automation Library of Logix Diagnostic Objects Version 3.5

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

CompactLogix 5370 L1 Controllers

Logix5000 Controllers

Logix5000 Controllers Information and Status

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E


ControlLogix Remote I/O Communication Module

Logix5000 Controllers Tasks, Programs, and Routines

MicroLogix 1400 Embedded Web Server

Module 1 Overview ControlLogix5000

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

for both the Verbatim Gateway and Catalyst Autodialer EtherNet Options

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

In this section we tell you how to set the fault mode selection plug, key your I/O chassis, install your module and make your wiring connections.

SCADAPack E ISaGRAF 3 User Manual

User Manual. PowerFlex 525 Embedded EtherNet/IP Adapter

Application Technique. Safety Function: Door Monitoring

Integrated Motion on the EtherNet/IP Network: Configuration and Startup

Gas Custody Transfer Calibration

SECTION CONTROL SOFTWARE

Technical Training Module ( 30 Days)

System Configuration Guide

Logix5000 Controllers Design Considerations

ControlLogix Redundancy

REMOTE MONITORING SYSTEM MATURE FIELDS UNCONVENTIONALS MONITORING SYSTEM. Solving challenges.

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

L5354 ControlNet Communications Interface

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

PowerFlex Dynamic Braking Resistor Calculator

Installation Guide. FactoryTalk Batch Material Manager Installation Guide

PITE 3921 Battery Monitoring System User Manual P V1.0

Product Bulletin. D20MX v1.40 Release Notification. GE Digital Energy. Release Notification of D20MX v1.40

INSTALLATION AND CONFIGURATION GUIDE. Rockwell Automation Publication HSE-IN025A-EN-E September 2013

Global Common Controls Software Design (GCCS-2) Course (Version 6.0)

ADM1TE 5/30A DIN rail single phase two wire energy meter

Visualization SIMATIC. Visualization. Present sample project. HMI configuration. Insert HMI device from libraries 3. Configuring HMI connection 4

PRODUCT PROFILE FEATURES

(Cat. No L3) Product Data

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

The Unique Accelabar Flow Meter

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Cisco UCS Director Payment Gateway Integration Guide, Release 4.1

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

SEMICONDUCTOR TECHNICAL DATA

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3. Simatic. Readme. Readme

Transcription:

Reference Manual Rockwell Automation Library of Process Objects: Pressure/Temperature Compensated Flow (P_PTComp) Version 3.1

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Labels may also be on or inside the equipment to provide specific precautions. SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Allen-Bradley, Rockwell Software, Rockwell Automation, RSLogix, Logix5000, FactoryTalk, and PlantPAx are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Table of Contents Preface Software Compatibility and Content Revisions....................... 5 Additional Resources............................................... 5 Pressure/Temperature Compensated Flow (P_PTComp) Guidelines......................................................... 7 Functional Description............................................. 8 Required Files..................................................... 8 Controller Code................................................... 9 Pressure/Temperature Compensated Flow Input Structure................................................ 9 Pressure/Temperature Compensated Flow Output Structure............................................. 10 Pressure/Temperature Compensated Flow Local Configuration Tags..................................... 10 Operations...................................................... 11 Modes....................................................... 11 Alarms...................................................... 11 Simulation................................................... 11 Execution.................................................... 11 Programming Example........................................... 12 Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014 3

Table of Contents Notes: 4 Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014

Preface This document is updated throughout for version 3.1 of the Rockwell Automation Library of Process Objects. Changes for this revision are marked by change bars, as shown in the right margin. Software Compatibility and Content Revisions Table 1 - Summary of Changes Topic Changed title from 'PlantPAx Library of Process Objects' to 'Rockwell Automation Library of Process Objects' Changed version of Rockwell Automation Library of Process Objects from 3.0 to 3.1 5, 8 Changed reference to Knowledgebase Answer ID 62682 to Product Compatibility and Download Center Input Parameters table - added 'Alias For' column and aliases 9 Output Parameters table: added 'Err-' parameter description to bullet list added 'Alias For' column Operations - added Simulation section 11 Page Front Cover 5 10 For the latest compatible software information and to download the Rockwell Automation Library, see the Product Compatibility and Download Center at http://www.rockwellautomation.com/rockwellautomation/support/pcdc.page. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource PlantPAx Process Automation System Selection Guide, publication PROCES-SG001 PlantPAx Process Automation System Reference Manual, publication PROCES-RM001 Rockwell Automation Library of Process Objects, publication PROCES-RM002 FactoryTalk View Machine Edition User Manual, publication VIEWME-UM004 FactoryTalk View Site Edition User Manual, publication VIEWSE-UM006 Logix5000 Controllers Add-On Instructions Programming Manual, publication 1756-PM010 Rockwell Automation Library of Process Objects: Basic Analog Input (P_AIn) Reference Manual, publication SYSLIB-RM001 Description Provides information to assist with equipment procurement for your PlantPAx system. Provides characterized recommendations for implementing your PlantPAx system. Provides general considerations for the PlantPAx system library of process objects. Provides details on how to use this software package for creating an automation application. Provides details on how to use this software package for developing and running human-machine interface (HMI) applications that can involve multiple users and servers, distributed over a network. Provides information for designing, configuring, and programming Add-On Instructions. Provides details on the P_AIn instruction for a Logix-based controller. You can view or download publications at http:/www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014 5

Preface Notes: 6 Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014

Pressure/Temperature Compensated Flow (P_PTComp) Add-On Instruction The Pressure/Temperature Compensated Flow (P_PTComp) Add-On Instruction is used to calculate a flow at standard temperature and pressure, essentially a mass flow rate, given a volumetric flow rate or differential pressure measurement. This instruction also requires measurements of the actual temperature and pressure of the flowing gas. Guidelines Use this instruction in these situations: You are measuring the flow of a gas, or the differential pressure of a gas that behaves (approximately) as an Ideal Gas across a flow element such as an orifice plate. You are measuring the temperature and pressure of the gas. You want to express the flow as a Flow at Standard Temperature and Pressure (STP), such as Standard Cubic Feet per Minute (SCFM). Do not use this instruction in these situations: You are measuring the flow of steam. You need to use the methods defined by ASME (or other standard or authority having jurisdiction), including the use of steam tables, to determine the properties of the steam to accurately calculate a mass flow. You are measuring the flow of natural gas. You need to use the methods defined by AGA (or other standard or authority having jurisdiction), to accurately calculate a mass flow. You are measuring the flow of solids or liquids, or of gases that do not behave (approximately) as an Ideal Gas. The P_PTComp Instruction uses the Ideal Gas Law (PV = nrt) to calculate flow at standard conditions. Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014 7

Pressure/Temperature Compensated Flow (P_PTComp) Functional Description The P_PTComp Add-On Instruction is intended as a calculation function only, between other blocks, and no HMI components are provided. If a faceplate and/or alarms are needed, the calculated output from the instruction can be sent to a P_AIn (analog input) Instruction for alarming and display. The P_PTComp Instruction provides the following capabilities: Takes as its primary input either a volumetric flow rate or a differential pressure across a flow element, such as an orifice plate or pitot tube. When a differential pressure is used, the P_PTComp instruction allows configuration of the volumetric flow rate for a given differential pressure. Accepts a temperature in common units (Fahrenheit or Celsius degrees) or in absolute units (Rankine degrees or Kelvins). Accepts a pressure in common units (PSIG, kpa Gauge, or MPa Gauge) or in absolute units (PSIA, kpa Absolute, MPa Absolute). Has user-configurable standard conditions, such as 14.696 PSIA and 60 F, or 101.325 kpa and 0 C. Determines flow at the specified standard conditions by using the Ideal Gas Law (PV = nrt) to adjust from the given temperature and pressure to the standard temperature and pressure. Required Files The P_PTComp_3_1-00_AOI.L5X Add-On Instruction, must be imported into the controller project to use the instruction in the project. The service release number (boldfaced) can change as service revisions are created. The import file is available from the Product Compatibility and Download Center at http://www.rockwellautomation.com/rockwellautomation/support/pcdc.page. There are no visualization files because the P_PTComp object does has no display elements or faceplates. 8 Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014

Pressure/Temperature Compensated Flow (P_PTComp) Controller Code This section describes the parameters of this Add-On Instruction. Pressure/Temperature Compensated Flow Input Structure Table 2 - P_PTComp Input Parameters Input parameters include the following: Input data elements (Inp_) are typically used to connect field inputs from I/O modules or signals from other objects. Configuration data elements (Cfg_) are used to set configurable capabilities and features of the instruction. Input Parameter Data Type Alias For Default Description EnableIn BOOL None 1 Ladder Diagram: If the rung-in condition is true, the instruction s Logic routine executes. If the rungin condition is false, the instruction s EnableInFalse routine executes. Function Block Diagram: If true, or not connected, the instruction s Logic routine executes. If the parameter is exposed as a pin and wired, and the pin is false, the instruction s EnableInFalse routine executes. Structured Text: No effect. The instruction s Logic routine executes. Inp_T_Act REAL 0.0 Actual (measured) temperature, can be absolute or common units (for example, Fahrenheit or Celsius). Inp_P_Act REAL 0.0 Actual (measured) pressure, can be absolute or common units (for example, PSIG). Inp_DP_Act REAL 0.0 Actual (measured) differential pressure (for example, WC). InP_F_Act REAL 0.0 Actual (measured) uncompensated flow in volumetric units (for example, CFM). Cfg_LoFlowCutoff REAL 0.0 If Out_Flow is less than this cutoff value, it is shown as 0.0. Cfg_T_Std REAL 0.0 Standard temperature in Inp_T_Act units (for example, Fahrenheit or Celsius). Cfg_P_Std REAL 0.0 Standard pressure in Inp_P_Act units (for example, PSIG). Cfg_T_Offset REAL 273.15 Zero input-units temperature in absolute units (for example, R or K). Cfg_P_Offset REAL 14.696 Zero input-units pressure in absolute units (for example, PSIA). Cfg_DP_Ref REAL 100.0 Reference (full-scale) differential pressure (for example, WC). Cfg_F_Ref REAL 1.0 Reference flow in volumetric units (for example, CFM) at Reference DP. Cfg_UseDP BOOL 0 1 = Use Inp_DP_Act (square root curve) to calculate flow. 0 = Use Inp_F_Act (linear). Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014 9

Pressure/Temperature Compensated Flow (P_PTComp) Pressure/Temperature Compensated Flow Output Structure Table 3 - P_PTComp Output Parameters Output parameters include the following: Output data elements (Out_) are the primary outputs of the instruction, typically used by hardware output modules; however, they can be used by other application logic. Status data elements (Sts_) are bit outputs of the instruction for use by the HMI. Status bits also can be used by other application logic. Error data elements (Err_) are bit outputs of the instruction used to indicate the reason for a configuration error. Output Parameter Data Type Alias For Description EnableOut BOOL None Enable Output: The EnableOut signal is not manipulated by this instruction. Its output state always reflects EnableIn Input state. Out_Flow REAL Compensated flow (at standard temperature and pressure: mass flow). Sts_Err BOOL 1 = Invalid configuration, see Err_bits. Err_T_Std BOOL 1 = Invalid standard temperature (T_Std + T_Offset must be > 0.0). Err_P_Std BOOL 1 = Invalid standard pressure (P_Std + P_Offset must be >0.0). Err_DP_Ref BOOL 1 = Invalid reference differential pressure (must be > 0.0 if DP used). Err_F_Ref BOOL 1 = Invalid reference flow (at reference DP) (must be > 0.0 if DP used). P_PTComp BOOL Unique parameter name for auto-discovery. Table 4 - P_PTComp Local Configuration Tags Tag Name Data Type Default Description Pressure/Temperature Compensated Flow Local Configuration Tags Configuration parameters that are arrayed, string, or structure data types cannot be configured as parameters for Add-On Instructions. Configuration parameters of these types appear as local tags to the Add-On Instruction. Local tags can be configured with RSLogix 5000 software by opening the Instruction Logic of the Add-On Instruction instance and then opening the Data Monitor on a local tag. These parameters cannot be modified by using controller logic or RSLogix 5000 software export/import functionality. The P_PTComp instruction does not include visualization elements (global objects or faceplates). However, these local configuration tags for descriptive strings are provided for use in custom visualization elements if desired. Cfg_Desc STRING_40 Pressure/ temperature compensated flow Cfg_Label STRING_20 Flow at standard conditions Description for display on HMI. This string is shown in the title bar of the faceplate. Label for graphic symbol displayed on HMI. This string appears on the graphic symbol. Cfg_Tag STRING_20 P_PTComp Tagname for display on HMI. This string is shown in the title bar of the faceplate. 10 Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014

Pressure/Temperature Compensated Flow (P_PTComp) Operations Modes The P_PTComp Add-On Instruction performs only calculations and does not have modes or contain a P_Mode instruction instance. Alarms The P_PTComp Add-On Instruction does not generate any alarms. To provide High-High, High, Low, and/or Low-Low threshold alarms for any of the variables (volumetric flow or differential pressure, temperature, pressure or the calculated Flow at Standard Conditions), use a P_AIn Analog Input instruction for each such variable. Refer to the Process Add-On Instructions and Graphics: Basic Analog Input (P_AIn) Reference Manual, publication SYSLIB-RM001, for more information. Simulation The P_PTComp Add-On Instruction does not have simulation capability. Execution The following table explains the handling of instruction execution conditions. Condition EnableIn False (false rung) Powerup (prescan, first scan) Postscan Description No EnableInFalse logic is provided. The Instruction maintains its last state when EnableIn is false. No Pre-scan or First Scan logic is provided. The P_PTComp instruction simply performs its calculation every scan when EnableIn is true. No SFC Postscan logic is provided. Refer to the Logix5000 Controllers Add-On Instructions Programming Manual, publication 1756-PM010, for more information. Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014 11

Pressure/Temperature Compensated Flow (P_PTComp) Programming Example This example uses the P_PTComp instruction to determine the flow rate of compressed nitrogen at a standard pressure and flow. This can provide a more accurate measurement for custody transfer or control calculations where there is variability in environmental conditions and the flow transmitter is not capable of performing the compensation. In this case, we have a measurement of flow from a dp-transmitter. The transmitter is providing the controller with a value that has been scaled to volumetric flow but not compensated for environmental temperature and pressure. We also have temperature and pressure measurements from where the flow is measured. In this example, the desired standard pressure and flow is 0 psig and 15 C. The measured temperature, pressure, and flow are connected into the P_PTComp instruction to the inputs Inp_T_Act, Inp_P_Act, and Inp_F_Act. In this example, these values are in units of degrees C, psig, and m 3 /hr. 12 Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014

Pressure/Temperature Compensated Flow (P_PTComp) Set Cfg_T_Std and Cfg_P_Std to 15 and 0, respectively, for the desired standard temperature and pressure. Cfg_T_Offset is left at its default of 273.15 to represent 0 C in absolute units K (if using Fahrenheit, set this to 459.67 F). Cfg_P_Offset is left at its default of 14.696 defining the value of 0 psi gauge pressure in absolute pressure. Cfg_UseDP is left at its default of 0, indicating we are using Inp_F_Act as the flow input as the flow transmitter is providing flow in volumetric units. The output of P_PTComp is then connected to a P_AIn Instruction. The output is a compensated volumetric flow at standard temperature and pressure. The P_AIn could scale this flow to mass flow if desired. The local configuration tags Cfg_Desc, Cfg_Label, and Cfg_Tag are not required to be set. The P_PTComp instruction does not include visualization elements (global objects or faceplates). However, these string parameters are provided for use in custom visualization elements if desired. Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014 13

Pressure/Temperature Compensated Flow (P_PTComp) Notes: 14 Rockwell Automation Publication SYSLIB-RM032C-EN-P - August 2014

Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support you can find technical and application notes, sample code, and links to software service packs. You can also visit our Support Center at https://rockwellautomation.custhelp.com/ for software updates, support chats and forums, technical information, FAQs, and to sign up for product notification updates. In addition, we offer multiple support programs for installation, configuration, and troubleshooting. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/services/online-phone. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Canada Use the Worldwide Locator at http://www.rockwellautomation.com/rockwellautomation/support/overview.page, or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to help ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication SYSLIB-RM032C-EN-P - August 2014 Supersedes Publication SYSLIB-RM032B-EN-P - September 2013 Copyright 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.