DATA SHEET MITEL 00 IP Communications Platform Providing feature-rich IP communication and advanced user applications to corporate local and wide area networks Controllers 00 CX / CXi 00 MXe II Standard 00 MXe II Expanded 00 MXe Server 00 AX Maximum number of devices including software agents 1 150 50 1,500 5,000 00 Maximum number of IP phones 00 1,00 5,000 Maximum number of SIP devices / users 00 1,000,000 Maximum ACD Agents 5 50 50 50 50 Maximum 5550 IP consoles Maximum number of analog phones 150 50 50 Shipped with: 1 Dual DSP module AMB Hard Disk Drive Power Supply 10 Echo Cancellers 1 Quad DSP module AMB Hard Disk Drive Power Supply 6 Echo Cancellers 1 Quad DSP module AMB Hard Disk Drive Power Supply Echo Cancellers 1 Quad DSP module RAID Controller Dual HDD Drives Dual Power Supplies 56 Echo Cancellers 1 Quad DSP module Flash Drive Power Supply Echo Cancellers 1//5 Engineering rules apply / For low traffic solutions, like Hospitality systems, up to a maximum of 576 devices will be supported, analog devices and up to IP devices. For systems of this size please refer to Mitel system engineering
DATA SHEET Controllers (cont d) 00 CX / CXi 00 MXe II Standard 00 MXe II Expanded 00 MXe Server 00 AX Available MMC Slots 6 5 MMC Slots for: Quad CIM Single T1 / E1 Quad BRI Dual and Quad DSP and DSP II Dual FIM Quad CIM Single and Dual T1 / E1 Quad BRI, Quad DSP, DSP II, Echo Canceller Dual FIM, Quad CIM Single and Dual T1 / E1, Quad BRI, Quad DSP, DSP II, Echo Canceller Quad DSP, DSP II Echo Canceller Single and Dual T1 / E1 Quad BRI Quad DSP, DSP II, Echo Canceller Maximum embedded T1 / E1 digital trunk modules 1 Maximum embedded BRI modules 1 10 / / 0 MB Ethernet ports See CXi Controller Data connectivity section (10 / Base T only) Maximum Dual DSP Modules 1 6 Maximum Quad DSP or (DSP II Modules) 1 (1) () () () 7 (1) Maximum Echo Canceller Channels 6 6 19 56 Maximum G.79a compression channels (DSP II =, Quad DSP =, Dual DSP = ) 6 with DSP II with Dual DSP 19 56 6 Maximum T channels Maximum number of NSU s (R NSU only) Maximum number of digital links (except BRI) Maximum Embedded BRI interfaces ( channels per interface) 1 1 Maximum number of Dual FIM modules 1 Dual FIM can be used to connect: NSU, DSU, Peripheral Cabinets, Triple FIM card and SX00 Bay NSU, DSU, Peripheral Cabinets, Triple FIM card and SX00 Bay R NSU Analog Main Board 6 LS trunks 9 ONS ports 6 LS trunks ONS ports 6 LS trunks ONS ports Analog Option Board 6 LS trunks ONS ports Analog Line card slots 10 1 6/7 Engineering rules apply Includes Music-on-Hold (1 source supported), Paging (1 paging zone), System Fail Transfer ( circuits) 9 Analog trunks support CLASS Signaling for North America and Latin America 10 The Analog Line card is available in two variants; the ONS circuit card and the LS trunks and 1 ONS extension card. Note the +1 Card supports SFT circuits. MITEL DATA SHEET 00 IP COMMUNICATIONS PLATFORM
Controllers 00 CX / CXi 00 MXe II Standard 00 MXe II Expanded 00 MXe Server 00 AX Maximum number of CIM connected ASU s 1 1 Maximum fiber connected peripheral nodes (with peripheral expander) 6 (1) 6 (1) Maximum number of fiber and copper connected SX00 Bays 7 7 Tone generators Tone detector circuits ET Channels 6 6 11 56 1 DTMF Receivers 19 IP Networking maximum IP trunks between controllers 00 00 00 00 00 IP Networking total max IP trunks SIP trunking total maximum SIP trunks SIP trunking max SIP trunks between peers 00 00 00 00 00 Maximum controllers in a cluster 1 STP and RSTP Embedded Voicemail ports as standard 0 0 Maximum embedded voicemail ports 1 0 0 0 Maximum mailboxes 750 750 750 750 Storage hours 50 50 50 70 Maximum messages per mailbox 11 Supports up to 19 ET channels when used in a Trunking Gateway configuration. 1 Supporting conference, music on hold and paging functions only. 1 Up to controllers can be clustered as a single system to support over 65,000 IP ports. Mitel s System Data Synchronization technology is used to enable feature transparency across a cluster of controllers. 1 Requires DSP on CX, and CXi and an additional GB flash drive on AX Controller. IP COMMUNICATIONS PLATFORM MITEL DATA SHEET
DATA SHEET Mitel 00 CXi Controller Data Connectivity Integral -port powered L 10 / Ethernet switch Has additional 10 / / 0 Ethernet uplink port Provides connection to additional switch ports and router Also has WAN port that is an Internet Gateway WAN port provides connection to an ISP for Internet access (e.g., DSL or cable) WAN port provides NAT and firewall capabilities WAN port does not support IP networking Use external router for IP networking Same as you would with a CX, MXe, AX Controller Embedded ACD 1,11 agent IDs Maximum of 50 total logged-in agents paths agent groups (500 agent IDs per group) Embedded Wireless Phones SpectraLink 0.11b* or Mitel IP-DECT wireless phones supported 0.11b or IP-DECT access points supported Custom integration with SpectraLink and IP-DECT MiNet wireless phones * 0.11b access points must be SpectraLink SVP compliant SIP Trunking Supports G.711 and G.79 compression SIP Trunking license required for each SIP channel Supports RFCs - RFC 61 SIP Session Initiation Protocol - RFC 6 Reliability of provisional responses in Session Initiation Protocol (SIP) - RFC 6 Locating SIP servers - RFC 6 An offer answer model with session description protocol - RFC 515 The Session Initiation Protocol (SIP) refer method - RFC 976 The SIP info method - RFC 5 Private extensions to the Session Initiation Protocol (SIP) - RFC 11 The MD5 message digest algorithm - RFC RTP payload for DTMF digits, telephony tones and telephony signals (section.10) SIP Line Side Supports G.711 and G.79 compression SIP Line license required for each SIP device connection Supports RFCs - RFC 11 The MD5 message digest algorithm - RFC 976 The SIP info method - RFC 61 SIP Session Initiation Protocol - RFC 6 Reliability of provisional responses in SIP - RFC 6 Locating SIP Servers - RFC 65 Specific event notification - RFC 11 The Session Initiation Protocol update method - RFC 515 The Session Initiation Protocol refer method - RFC 91 The Session Initiation Protocol replaces header - RFC 0 Session timers in the Session Initiation Protocol - RFC 60 A Session Initiation Protocol event package for registrations - RFC A message summary and message waiting indication event package SIP - RFC 7 SDP: Session description protocol - RFC 6 An offer / answer model with SDP - RFC RTP payload for DTMF digits, telephony tones and telephony signals MITEL DATA SHEET 00 IP COMMUNICATIONS PLATFORM
Digital Trunk Connectivity Universal NSU (MXe II Controller) Connects to controller via a FIM link A second NSU can be daisy chained from the first NSU via CIM (allows two NSUs per FIM link) Each NSU supports two digital links Both links in an NSU must run the same protocol (T1-D or MSDN / DPNSS or PRI / QSIG) Supports: CAS (T1-D) digital E&M, digital CO, digital DID, IDA-P T CCS Primary Rate ISDN, XNET over PRI, QSIG, MSDN / DPNSS 1 QSIG, Euro ISDN, XNET over PRI, DASSII, MSDN / DPNSS R NSU (MXe II and 00 AX Controller) Each R NSU supports two links Connects to controller via a FIM link A second NSU can be daisy chained from the first NSU via CIM (allows two NSUs per FIM link) Dual Embedded Digital Trunk Module (MXe II / AX) Each module has two E1/T1 trunk interfaces (links) Provides PRI / QSIG / T1-D / DASS II / DPNSS / IDA-P protocol through the controller (no NSU required) Each interface can run a different protocol, either PRI, QSIG, or T1-D Single Embedded Digital Trunk Module (CX / CXi / MXe II / AX Controllers) Each module has a single E1 / T1 trunk interface (link) Provides PRI / QSIG / T1-D / DASS II / DPNSS / IDA-P protocol through the controller (no NSU required) Resiliency (switches to secondary controller) Does not support: Min / Max, NFAS, D-Channel Backup or TDM XNET (Hybrid XNET is supported) Embedded BRI Module (CX / CXi / MXe II / AX Controllers) The Embedded BRI module has four Basic Rate Circuits (total 6kbs channels) Each channel may be configured as either a: T (trunk) interface for links from a BRI Central Office (CO) S (subscriber) interface for connecting up to eight BRI devices. Note: S interfaces support only basic call features such as calling number display for BRI devices (BRI call handling such as Hold or Transfer are not supported). BRI devices are not line powered from the embedded BRI module. Note: This module does not support U interfaces. Does not support: Min / Max, NFAS, D-Channel Backup or TDM XNET (Hybrid XNET is supported) IP COMMUNICATIONS PLATFORM MITEL DATA SHEET 5
DATA SHEET Dimensions Height 00 Controller Analog Services Network Services Peripheral Cabinet Unit (ASU) Unit (NSU) CX / CXi / MXe II / MXe Server.5 in (.9 cm) (U) AX 1.5 in (9.90 cm) (7U) ASU 1.75 in (.5 cm) (1U) ASU II. in (. cm) (U) 1.75 in (.5 cm) (1U) 19.0 in (.0 cm) Width CX/CXi/MXe II/MXe Server 17.75 in (5.1 cm) 19 rack mountable AX 17. in (.0 cm) 17.75 in (5.1 cm) (19 rack mountable) 17.75 in (5.1 cm) (19 rack mountable) 1.0 in (5. cm) Depth CX / CXi.5 in (1.9 cm) MXe II / MXe Server 0.5 in. (51. cm) AX 1.7 in (5. cm) ASU 15.5 in (9. cm) ASU II 1. in (. cm) 15.5 in (9. cm) 19.0 in (.0cm) Weight CX / CXi 19. lb (.9 kg) MXe II lb. (1.7 kg) MXe Server lb (15 kg) AX 9.70 Ib. (1.01 kg) ASU 10.61 lb. (.1 kg) ASU II 1.1 lb. (6. kg).1 lb (.7 kg) 71. lb (.6 kg) Operational Environment Temperature 00 Controller Analog Services Network Services Peripheral Cabinet Unit (ASU and ASU II) Use (NSU) 0 to 1 F ( to 50 C) 0 to 1 F ( to 50 C) 0 to 1 F ( to 50 C) 0 to 1 F ( to 50 C) Humidity 5%-95% relative humidity, noncondensing 5%-95% relative humidity, noncondensing 5%-95% relative humidity, noncondensing 5%-95% relative humidity, noncondensing Max Heat Dissipation fully loaded CX / CXi 170 BTUs per hour MXe II 750 BTUs per hour MXe Server 0 BTUs per hour AX 10 BTUs per hour ASU 170 BTUs per hour ASU II 60 BTUs per hour 60 BTUs per hour 7 BTUs per hour Air Flow 6 cubic ft/min at maximum output of fans AX 110 cubic ft 150 cubic ft/min at maximum output of fans Acoustic Emissions Max 50dBA continuous, 75dBA intermittent (<10% duty cycle) Max 50dBA continuous, 75dBA intermittent (<10% duty cycle) Conversion factors: One watt is equal to.1 BTUs per hour. One ton of refrigeration is equal to 1 BTUs per hour or.5 Kilowatts, and 0.75 kilowatt-hour is equal to one ton of refrigeration. 6 MITEL DATA SHEET 00 IP COMMUNICATIONS PLATFORM
System Input Power Requirements Input / Disconnect 00 Controller Analog Services Network Services Peripheral Cabinet Unit (ASU and ASU II) Use (NSU) IEC0-C1 Class 1 AC Receptacle Receptacles on AX and MXe II / MXe II Server with redundant power IEC0-C1 Class 1 AC Receptacle IEC0-C1 Class 1 AC Receptacle IEC0-C1 Class 1 AC Receptacle Input Voltage / Frequency Rating -0 VAC 50 / 60 Hz -0 VAC 50 / 60 Hz -0 VAC 50 / 60 Hz 10-10 VAC 50 / 60 Hz MP91AA PSU Variant00-0 VAC 50/60 Hz MP91AD PSU Variant Input Power CX / CXi 50 W MXe II 00 W MXe II Expanded 50 W MXe II Server 00 W AX 00 W ASU 75 W max ASU II 15 W max Universal NSU 0 W R NSU 0 W 00 W typical (ONS and DNI Mix) 00 W typical (all DNI) 50 W Max (input surge, all DNI) AC Source 90-6 VAC 90-6 VAC 90-6 VAC 10-1 VAC MP91AA 17-6 Hz MP91AD Frequency Range 7-6 Hz 67-6 Hz 67-6 Hz 7-6 Hz IP COMMUNICATIONS PLATFORM MITEL DATA SHEET 7
Glossary ACD Automatic Call Distribution ASU Analog Services Unit BRI Basic Rate Interface BTU British Thermal Unit CAS Channel Associated Signaling CCS Common Channel Signaling CIM Copper Interface Module CLASS Custom Local Access Signaling Services DASSII Digital Access Signaling System # DID / DDI Direct Inward Dial / Direct Dial In DNI Digital Network Interface DPNSS Digital Private Network Signaling System DSP Digital Signal Processor DTMF Dual Tone Multi-Frequency FIM Fiber Interface Module IP Internet Protocol Integrated 00 A 00 controller that manages both telephones and external call routing ISDN Integrated Services Digital Network LS Loop Start Trunk MMC MITEL Mezzanine Card MOH Music on Hold MSDN Mitel Superswitch Digital Network NFAS NSU OPS PRI QSIG RSTP SIP STP T Non-Facilities Associated Signaling Network Services Unit Off Premises, long loop analog PBX ports Primary Rate Interface, ISDN Q Signaling Protocol Rapid Spanning Tree Protocol Session Initiation Protocol Spanning Tree Protocol ITU protocol to send FAX transmission accross networks Trunking Gateway A 00 controller used specifically to land PSTN trunks and route them onto a user gateway User Gateway A 00 controller / server used specifically to manage and control telephones. External traffic is routed via a Trunking Gateway VM Voice Mail XNET Switched Networking Global Headquarters U.S. EMEA CALA Asia Pacific Tel: +1(61) 59-1 Fax: +1(61) 59-7 Tel: +1(0) 961-9000 Fax: +1(0) 961-170 Tel: +(0)191-0000 Fax: +(0)191-000 Tel: +1(61) 59-1 Fax: +1(61) 59-75 Tel: +5 50 970 Fax: +5 50 9 www.mitel.com For more information on our worldwide office locations, visit our website at www.mitel.com/offices THIS DOCUMENT IS PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. The information furnished in this document, believed by Mitel to be accurate as of the date of its publication, is subject to change without notice. Mitel assumes no responsibility for any errors or omissions in this document and shall have no obligation to you as a result of having made this document available to you or based upon the information it contains. M MITEL (design) is a registered trademark of Mitel Networks Corporation. All other products and services are the registered trademarks of their respective holders. Copyright 009, Mitel Networks Corporation. All Rights Reserved. GD _5 PN 571RK-EN