Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version



Similar documents
SITRANS F flowmeters SITRANS F M

Electromagnetic Flow Meter

How To Use A Flowmeter

INSTALLATION, OPERATION & MAINTENANCE MANUAL

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Butterfly Valves PN 6/10/16 for flanged connection

Plastic tube flowmeters Series PT/PS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Digital inductive conductivity transmitter

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

The Unique Accelabar Flow Meter

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

G670 Intermittent Pilot Ignition Controls

Build your own flowmeter

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

CRN A-F-G-E-HQQE 3x400D 50 HZ

System 8. ü ( System 8

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Bypass level indicator With magnetic display Model BNA

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

ATS Overhead Table Shelf System INSTRUCTION MANUAL

IFC 070 Technical Datasheet

ELECTROMAGNETIC FLOWMETER COMPACT

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Rosemount 8700 Series

Toroidal Conductivity Sensor

Materials : Cast iron body

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

SJT / SJM / SJP Large Vertical Pumps

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Series description: Wilo-Yonos MAXO

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Maintenance and Instruction Manual. December 2011 Rev. 01 Page 1 of 12

Operating Instructions Drill rig DRU160

Inductive sensor NI10-M18-Y1X-H1141

Series DFMT Digital Paddlewheel Flowmeter

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

Fluxi 2000/TZ Turbine Gas Meter

! WARNING. Before using product, read and understand instructions.

Series 510 Submersible Level Transmitters

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

OPTIMASS 6000 Technical Datasheet

Mounting Instructions. Torque Transducer. A en

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Trouble Shooting. Pump

Installation, Maintenance, & Repair Series 4000B/LF4000B

2- and 3-port valves with flanged connections, PN 10

81000 Series Aluminum Gate Valve Installation and Repair Manual

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Flow Measurement Options for Pipeline and Open Channel Flow

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Vertical selfpriming Side-Channel Pumps Type WPV

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ALMATEC Series CX CX 10 CX 130

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

VAD. Variable Area Desuperheaters

Flow switches Series AD/VH

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

VAD Variable Area Desuperheaters

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Installation and safety instructions for AC/DC built-in devices

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Operating Instructions for Plastic Flow Meter. Model: KSK

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

AC Electric Motors best practice

OPTIMASS 1400 Technical Datasheet

Air Eliminators and Combination Air Eliminators Strainers

Self-operated Temperature Regulators Temperature Regulator Type 1u

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Hydraulic Control Solutions

Operation Manual. Diaphragm pumps 1-headed MPC 301 E

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

MFP14, MFP14S and MFP14SS Automatic Pumps

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

SunMaxx Solar Filling Station Operating Instructions

Series description: Wilo-Yonos MAXO-D

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Operation & Maintenance Manual

Instruction Manual Differential Pressure Transmitter

Safety at a high level!

sealed close coupled pumps

Transcription:

instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory and NOT a safety accessory as defined in the 97/23/EC directive, Article 1, paragraph 2.1.3. R-MI-FlomidFX Rev.: 0 English version

WORKING PRINCIPLE The Flomid electromagnetic flowmeters, are based on Faraday s induction law. When an electrically conductive liquid flows through a magnetic field, perpendicular to the flow direction, it induces a voltage V m, proportional to the liquid velocity. Two electrodes in contact with the liquid and positioned perpendicular to the magnetic field, sense this voltage V m. V m = B v m D Where: V m = Measured voltage in the electrodes. B = Magnetic flux density v m = Average liquid velocity D = Pipe diameter. RECEPTION The FLOMID electromagnetic flowmeters are supplied conveniently packed for transport together with their instruction manual for installation and operation. All the flowmeters have been verified in our calibration rigs to obtain the factor Fc for each sensor. Disassembly Unpack the instrument carefully, removing any remains of the packing from the inside of the sensor. Do not remove the grease from the neck that couples to the electronics housing. Storage temperature Sensors linings of : PTFE and PVDF -20ºC... +60ºC PP and EBONITE -5ºC... +50ºC HANDLING It should always be done with care and without knocks. The large diameter sensors have rings for holding the elevation elements. If the flowmeter is held using slings, these should hold on the sensor and not on the electronics housing (see the drawing). 2

INSTALLATION This should be made in a point that guarantees that the pipe is always completely full. Avoid high points of the pipes where air pockets usually form, or pipes with falling flow where vacuums can form. Partially full pipes can produce important reading errors. Flow rate measurement with open discharge makes it necessary to install the flowmeter in a pipe section with a siphon which avoids stagnation of air in the sensor. Sensor position The most adequate position is with the electrodes in a horizontal plane. In this way, deposits of particles on the electrodes are avoided. Straight pipe sections Are necessary before and after the sensor. The minimum distances are the following: Upstream : 5 DN Downstream : 3 DN In installations with turbulent flow it may be necessary to increase these distances. Mixtures If liquids of different conductivities are mixed it is necessary to install the sensor a minimum of 30 DN from the point of mixture in order to obtain a uniform conductivity of the liquid and stabilize the readings. If this distance is less, the readings may be unstable. 3

Control valves or stop cocks should always be installed downstream from the sensor to assure that the pipe is always full of liquid. Pumps should be mounted upstream from the sensor to avoid the suction part of the pump (vacuum) that could damage the sensor liner (see the table on page 8). If there is a point where the difference in level is greater than 5 m an air inlet valve should be installed after the sensor to avoid a vacuum effect that could damage the sensor liner (see the table on page 8). Reduction of the DN In installations where, for reasons of the flow rate to be measured, a sensor of a smaller DN than the pipe DN must be mounted, the reduction must be done with an angle smaller than 4º to avoid turbulences that can give false readings. If the reduction angle is greater then the straight pipe sections indicated on the previous page must be respected. α < 4º α α > 4º α 4

Vibrations Vibrations of the pipes should be avoided by anchoring the pipe before and after the sensor. The vibration level should be less than 2.2 g in the range of 20-150 Hz according to IEC 068-2-34. Magnetic fields Strong magnetic fields close to the sensor should be avoided. Temperature In open air installations it is recommended to install a protection to avoid direct sun light on the flowmeter. With thermally insulated pipes DO NOT insulate the sensor. High temperatures can damage it. The maximum liquid temperatures are shown on page 8. MOUNTING Parallelism The maximum parallelism error must be less than 0.5 mm (Lmax Lmin 0,5 mm). Gasket position For the sandwich mounting sensors, to avoid leakage into the inside of the sensor one must make sure that the rubber gasket (A) (drawing on the following page) is fitted into the stainless steel ring so that it will be pressed directly on the plastic liner. If the rubber gasket seals against the stainless steel ring then the liquid pressure will force liquid into the interior of the sensor causing irreparable damage. 5

Tightening torque The tightening torque for the flange bolts should not exceed 32 Nm for working pressures of 16 bar maximum. This tightening torque should be applied to sandwich mounting (Flomid 0FX) and also to DIN, ANSI, JIS etc. flange mounting sensors for the same working pressure of 16 bar. The maximum tightening torque varies in function of the nominal pressure (PN) of the sensor. The tightening of the bolts should be uniform, following the sequence shown in the drawings and depending on the number of flange bolts. SENSOR EARTH CONNECTION (only for sandwich and flange mounting sensors ) To obtain correct operation the sensor should have its functional earth connected to a point that is in direct contact with the liquid to be metered. The earth cables should assure a good electrical contact. To obtain this, they should be well screwed down and with a good contact on both sides of the sensor. It is important to eliminate paint or coverings that act as insulation of the connection. The functional earth connection should be used exclusively for the sensor given that parasitic signals caused by other electrical equipment connected to this earth can cause malfunction of the sensor. In the case that there are high voltage differences between different earth points, this will cause currents that may give problems in the readings (empty pipe indication). In these cases, do not connect the functional earth to the protective earth of the mains. 6

The connection of the functional earth should be made as follows: A) In the case of metallic pipes without internal lining connect the earth cables to the counterflanges. B) In the case of metallic pipes with internal lining or plastic pipes, connect the earth cables to the earth disks, supplied on demand. METALLIC PIPES METALLIC PIPES Without internal lining With internal lining or PLASTIC PIPES EARTH DISKS The earth disks are necessary when the installation is with plastic pipes or metallic pipes with an internal insulating lining (PTFE, PVDF, PP EBONITE etc.). The earth disks are supplied in two versions: METALLIC, in the form of a disk in stainless steel EN 1.4404 (AISI316L), for liquids compatible with this material. PLASTIC, that have an electrode to make the contact with the liquid. The materials (plastic and metal) depend on the product to be metered. The electrodes can be EN 1.4404, Hastelloy C, Titanium, Zirconium, etc.. MAINTENANCE It is recommended to clean the electrodes in installations where incrustations or appreciable sedimentations can occur. Cleaning can be done using liquid detergents and medium hard brushes. 7

TEMPERATURE, PRESSURE and VACUUM LIMITS WARRANTY Tecfluid S.A. GUARANTEES ALL ITS PRODUCTS FOR A PERIOD OF 24 MONTHS, after consignment, against all defects in materials and workmanship. This warranty does not cover failures which can be imputed to misuse, use in an application different to that specified in the order, the result of service or modification by un-authorized persons, bad handling or accident. This warranty is limited to cover the repair or replacement defective parts which have not been damaged by misuse. This warranty is limited to the repair of the equipment and all further and eventually following damages are not covered by this warranty. Any consignment of equipment to our factory or distributor must be previously authorised. The consignment should be done with the equipment well packed, clean of any liquids, grease or hazardous materials. Tecfluid S.A. will not accept any responsibility for damage done during transport. Together with the equipment, a note should be enclosed indicating the failure observed, the name, address and telephone number of the sender. Bosmanskamp 30, 4191 MV Geldermalsen Tel. +31 (0) 345 596 000 Fax +31 (0) 345 596 001 www.adinco.nl info@adinco.nl