BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!



Similar documents
- GFRP pipe liners - UV curing technology - TQM - Total Quality Management

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Introduction to Pressure Pipe Rehabilitation with CIPP

epros DrainLiner Program

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

GENERAL SPECIFICATIONS AND GUIDELINES FOR INSTALLATION MASTERLINER CURED-IN-PLACE PIPE SYSTEMS

INSTALLATION OF INSITUFORM LINER

SECTION NONREINFORCED CONCRETE SEWER PIPE

SIGRAFLEX . Properties. Applications

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

PRESSURE PIPE REHABILIATION CIPP TECHNOLOGIES

Rainwater going astray. EPROPOX FC30 epoxy resin system to be prepared for a rainy day

Rehabilitation or Replacement? That Is The Question

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Flowtite Jacking Pipe

Competition moves up to the test winner

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

ElastoFlake & ElastoTec

02780 LINER FOR SEWER REHABILITATION

Section 2320 Cured-In-Place Pipe Lining

Puddle Flange. FRANK Puddle Flange

IS THAT LINER THICK ENOUGH?

Sewer network renovation using glass-fiber reinforced (GRP) pipe liners

Oil and Gas Pipeline Design, Maintenance and Repair

PP MASTERTM S T I F F N E S S S N 1 2 R I N G THE NEW POLYPROPYLENE SEWER PIPE SYSTEM

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

TRELLEBORG INDUSTRIAL SOLUTIONS. MtH practice Part 2 EXPERT AUDIENCE WAS PATENTLY CONVINCED IN MUNICH

Pressure Pipe and Sewer Renovation

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Pipeline Replacement using Relining

CURED-IN-PLACE PIPE MINIMIZING RISK BY DEFECT CODING

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

U-LINER AC NEW AND UNIQUE ADHESIVE PE-LINER FOR DOMESTIC CONNECTIONS. Construction Automotive Industry

REPAIRS TO DAMAGED SEWERS

CHARACTERIZATION OF HIGH PRESSURE RTM PROCESSES FOR MANUFACTURING OF HIGH PERFORMANCE COMPOSITES

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

SA Pipe Relining is dedicated to finding simple, non intrusive

REHABILITATION OR REPLACEMENT? THAT IS THE QUESTION

SS 201 Linings for Circular Non Man Entry Pipes

Mold Preventing I nterior System

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

The KLINGERexpert 5.2.1

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Comparison of Steel Tubes and Thermoplastic Hoses in Umbilical Service

WATERPROOFING OF WET ROOMS

Meeting the Challenge of Pipeline Emergency Repair

Tubular solutions for the Solar Power Industry Rise in success with precision

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Lateral Connection repair in main sewer pipes DIBt Z Z Z Z

Water Main Lining A Sustainable Alternative to Open Cut Replacement

building applications copper - redefined

UVDB empowered by Achilles

Grooved gaskets. Types of gaskets

Green Thread Product Data

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

GRP Pipe systems. for Water, Sewage and Industrial Applications

PAAM COMMERCIAL PRIVATE LIMITED

SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES

Sterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos

THE ECOLOGICAL IMPLICATIONS OF TRENCHLESS PIPE REHABILITATION

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Concrete Pipes. Concrete Pipes

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Reinforcement HUESKER. HaTelit. Engineering with geosynthetics

EI- MH TO MH LINER

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Structural Lining for Water Mains. Presenters: Stephen Marcino, PE and Micah Blate, EIT (JMT)

SKER HUESKER HUESKER geogrid HUESKER HUESKER for HUESKERHUES SKER HUESKER HUESKER HUESKERHUES SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES

Culvert Rehabilitation Practices

Series 4000 Fiberglass Pipe and Fittings

Polyurea Coatings in Secondary Containment with National Technical Approval. Jürgen Magner Kiwa Polymer Institut Flörsheim / Germany

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Summary 7/11/2012. Michigan Water Environment Association 2012 Annual Conference Boyne Mountain Resort

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

SEKISUI SPR CONSTRUCTION PIPE SYSTEMS FOR THE NEXT GENERATIONS

How To Repair A Steel Pier With A Watertight Frame

Transcription:

BKP Berolina Polyester GmbH & Co. KG Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

Berolina-Liner System The Berolina-Liner System sets new standards in pipe rehabilitation. With the Berolina-Liner System, BKP has developed an innovative procedure which is very successful on the market for the efficient and economical rehabilitation of gravity pipes. The Berolina-Liner is a resin-impregnated tube that is fed through a manhole into the pipe to be renovated. The liner is cured in place thereby sealing the pipe against leakage. In addition, the- Berolina-Liner structurally reinforces the piping system. This process avoids the need for extensive excavation and only a marginal, short-term disturbance of the infrastructure around the rehabilitation site is necessary. The energy requirement for production, transport and installation of the liner is extremely small in comparison with traditional procedures. Compared to competing systems, the Berolina-Liner System is noted for a markedly reduced CO 2 emission during installation and the curing process. The Berolina-Liner System is completed by installation equipment specially optimized for the Berolina-Liner. This is offered by BKP in different adjusted variants according to clients specifications. Tailor-made equipment variants make the application of the Berolina-Liner System possible at nearly any location globally Environmental Consciousness Carbon CO2-Verbrauch emission in pro100 kg per Meter 100 m Curing Aushärtung process Wasser Water Dampf Steam UV-Light The Berolina-Liner is cured by using UV-light. This process is temperatureindependent and causes far less CO 2 emissions than other curing methods. This advantage is, in turn, multiplied by the short installation times, without the need for extensive trenching and disturbance to the economic and social infrastructure. This is inexpensive and protects our environment. Durchmesser-mm ID (mm)

Liner Structure The unique tube structure is integrated to the outstanding quality and versatile applicability of the Berolina-Liner System. The Berolina-Liner consists of corrosion-resistant fiberglass complexes and/or polyester felts impregnated with high-grade polyester resin or vinylester resin which are arranged in an overlapping and displaced manner in relation to each other. With its variable stretching property, the seamlessly produced Berolina-Liner fits optimally into any profile, especially circular and oval profiles of diameters between 150 mm and 1,600 mm (6-63 ). Cross-section transitions or profile transitions pose no problems for the Berolina-Liner. The continuous fiber orientation in the circumference direction optimizes the power flow without impairing the stretching. The fiberglass arranged along the lengthwise direction of the Berolina-Liner enables the absorption of all draw-in forces occurring during the liner installation. Only slight wall thicknesses are necessary due to the best mechanical parameters. Through these, cross-section loss is reduced to a minimum following the pipe rehabilitation. BKP produces the Berolina-Liner with a protective inner film and a UV-proof outer film. The Berolina-Liners are delivered wet-out and ready to install, guaranteed and usable without loss of quality up to 6 months at normal room temperature. The Berolina-Liners are continuously produced and can also be built in extremely long sections (up to 400 m) at a stretch. R ing E-module Wall thickness GRP vs. synthetic fibre (long-term ring stiffness, 5,000 N/m² (0.73 psi / 5,000 Pa)) 24 Characteristics GRP (Berolina-Liner) Synthetic fibre / polyester resin 21 18 15 12 9 Mininum wall thickness (mm) Synthetic fibre GRP (Berolina-Liner) 6 Diameter of host pipe (mm) 3 200 250 300 350 400 450 500 550 600 650 The values of the Berolina-Liner, established by the TÜV (German Technical Monitoring Association) and the Institute for Pipeline Construction at the Fachhochschule Oldenburg Ring E-module at least 10,000 N/mm² (1,450,000 psi / 10,000 MPa), tension E-module approx. 14,000 N/mm² (2,030,500 psi / 14,000 MPa)

Rehabilitation After thorough cleaning, first the gliding foil and then the Berolina-Liner are winched in the host pipe. This procedure is known as the winched in place procedure. The two ends are closed with end cans, the tube carefully inflated with approx. 0.5 bar (7.5 psi) compressed air and pressed onto the pipe wall. In this way, the outer film of the Berolina-Liner prevents contamination from soil and ground water as well as penetration of resin into the laterals. The Berolina-Liner now adapts itself positively to all changes in the cross-section and profile. Compressed air as a medium offers, among other things, the advantage that the uncured Berolina- Liner can be inspected during the drawing-in of the UV-light source with the help of a special camera. Following this, the UV-light source is ignited and drawn through the Berolina-Liner at a defined speed. The liner is thus cured through the UV-light. The inner protective film is removed afterwards. The curing takes place emission-free with sealed-off tube endings. A new pipe is created in the host pipe within the shortest period of time and without damage to the environment; it is a stable inner lining for all customary pipe materials including brick-lined ducts. The slight cross-section loss is functionally compensated by the smooth and abrasion-tight inner chemically protective liner surface of the Berolina-Liner. The curing speeds vary according to the diameter and wall thickness of the Berolina-Liner. the UV-light. The inner protective film is removed afterwards. The curing takes place emission-free with sealed-off tube endings. A new pipe is flexibility of the Berolina-Liner allow them to be detected optically. They are then cut out immediately after the curing and the Liner can be closely bound to the lateral using customary procedures. Glimpses Into The Rehabilitation Process Visit our virtual building site at

Quality Management DIBt Quality Assurance ISO 9001:2008 Approval no. PT/331/0412 Approval no. Production of the Berolina-Liner is internationally certified according to DIN EN ISO 9001:2008 and is regularly inspected by the TÜV (German Technical Monitoring Association). In order to ensure continual quality at highest level, we carry out detailed tests on every production batch. Alongside the good control system, the inspections include a constant testing of the liner by our trained production and quality control staff. Not only the production at our plant, but also the installation of the liner on-site, is subject to a detailed quality assurance inspection such as TV inspection during and after curing using a remote camera. All installation parameters are documented. Finally, the cured liner pipe is tested. The most important testing criteria: 1. External initial tests:. High pressure jetting tests according to the Hamburg Model (60 jetting processes) 10,000-hour fatigue tests Leakage test (CP308) Strain corrosion test Darmstadt tilted drain experiment Burning test 2. Internal quality monitoring prior to delivery: Functional and reactivity test Impermeability test in accordance with DIN/EN 1610 Measurement of the wall thickness Measurement of the initial annular stiffness 3-point bending test Measurement of the resin content Barcol hardness Residual styrene content 3. External quality supervision after installation: Impermeability test Measurement of the wall thickness Measurement of the initial annular stiffness 3-point bending test Measurement of the resin content Residual styrene content as well as other tests specific to the given countries. Quality First

Advantages Construction approval by the Deutsche Institut für Bautechnik (German Institute for Construction Technology), DIBt Z-42.3-336 and other international approvals Production controlled and supervised by the German Technical Monitoring Association (TÜV) at our plant in Berlin in accordance with the quality standards of DIN EN ISO 9001:2008 Worldwide ready-to-install delivery, as well as up to 6 months shelf life without loss of quality Double quality control through camera coverage of the Berolina-Liner before and after the curing Less space required in the installation of the Berolina-Liner at the construction because all the equipment relevant to the installation is stored in a truck Brief installation times due to the UV -light curing Seamless construction and smooth surface, chemical resistant inner layer Suitable for all circular and oval profiles, ID 150 mm - ID 1,600 mm (6-63 ) or other equivalent profiles Bridge-over of profile and cross-section exchanges is possible Highest mechanical parameters due to fiberglass reinforcement; for this reason, only slight wall thicknesses are necessary and there is only slight cross-section loss after the rehabilitation Selection of material according to requirements Reduction of waste products due to the curing procedure (e.g. no process water) Ordering according to stiffness classes Reduced energy requirements during production, transport and installation Complete opening of the laterals is possible immediately following the curing of the liner VELTEN BKP Berolina Polyester GmbH & Co. KG Heidering 28 16727 Velten Germany Phone: Telefax: +49 (0) 3304 2088-100 +49 (0) 3304 2088-110 e-mail: info@bkp-berolina.de A Company of For Für All alle Customary gängigen Pipe Rohrprofile Profiles 06/2015