Temperature-Aware Design of Printed Circuit Boards



Similar documents
Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card

Application Note: PCB Design By: Wei-Lung Ho

Trace Layer Import for Printed Circuit Boards Under Icepak

POWER FORUM, BOLOGNA

Intel Atom Processor E3800 Product Family

Balancing the Electrical and Mechanical Requirements of Flexible Circuits. Mark Finstad, Applications Engineering Manager, Minco

Development of a Design & Manufacturing Environment for Reliable and Cost-Effective PCB Embedding Technology

IIB. Complete PCB Design Using OrCAD Capture and PCB Editor. Kraig Mitzner. ~»* ' AMSTERDAM BOSTON HEIDELBERG LONDON ^ i H

Shrinking a power supply and the challenge to maintain high reliability.

Embedding components within PCB substrates

AC-DC Converter Application Guidelines

Surface Mount Technology cooling for high volumes applications by: Cesare Capriz Aavid Thermalloy via XXV Aprile 32 Cadriano (BO) ITALY

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

Rigid-Flex Technology: Mainstream Use but More Complex Designs by John Isaac October 1, 2007

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Automating Inter-Layer In-Design Checks in Rigid-Flex PCBs

Grounding Demystified

Agenda. Who we are What we do How we serve the BPO Industry

Using CFD for optimal thermal management and cooling design in data centers

PADS PCB Design Solutions

(English version) CNPS9500 AT

Cisco Data Center Facilities Assessment Service

Thermal Management for Low Cost Consumer Products

DirectFET TM - A Proprietary New Source Mounted Power Package for Board Mounted Power

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Figure 1 FPGA Growth and Usage Trends

Data Centers. Comparing Data Center & Computer Thermal Design

Accelerometer and Gyroscope Design Guidelines

LO5: Understand commercial circuit manufacture

The Evolution of ICT: PCB Technologies, Test Philosophies, and Manufacturing Business Models Are Driving In-Circuit Test Evolution and Innovations

APC APPLICATION NOTE #92

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Alpha CPU and Clock Design Evolution

Analog Servo Drive 25A8

Dealing with Thermal Issues in Data Center Universal Aisle Containment

BUILD VERSUS BUY. Understanding the Total Cost of Embedded Design.

LDS WLED Matrix Driver with Boost Converter FEATURES APPLICATION DESCRIPTION TYPICAL APPLICATION CIRCUIT

LDO03C/LDO06C/LDO10C

Prototyping Printed Circuit Boards

Graser User Conference Only

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

Technical Article. Multi-phase DC-DC PMIC: the efficient, space-saving choice for today s application processors. Peter Kammerlander

HSD High Speed Data interconnection

Metallized Particle Interconnect A simple solution for high-speed, high-bandwidth applications

Allegro Design Authoring

Element D Services Heating, Ventilating, and Air Conditioning

Thermal Simulation of a Power Electronics Cold Plate with a Parametric Design Study

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

MID, Flexible Circuits or Printed Circuit Boards? Technology Selection Based on Virtual Prototypes. 1 MID Congress 2010

Simulation and Design of Printed Circuit Boards Utilizing Novel Embedded Capacitance Material

HDA

Virtual Data Centre Design A blueprint for success

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

ILX Lightwave Corporation

What is surface mount?

Power Noise Analysis of Large-Scale Printed Circuit Boards

CS4525 Power Calculator

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

PADS PCB Design Solutions

Using Simulation to Improve Data Center Efficiency

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Mini-ITX Addendum Version 2.0 To the microatx Motherboard Interface Specification Version 1.2. October 2010

Article from Micrel. A new approach to the challenge of powering cellular M2M modems By Anthony Pele Senior Field Applications Engineer, Micrel

A NEAR FIELD INJECTION MODEL FOR SUSCEPTIBILITY PREDICTION IN INTEGRATED CIRCUITS

AU-110 racking guide NBXPN: 023

CLA LF: Surface Mount Limiter Diode

A Program for PCB Estimation with Altium Designer

CADSTAR Training Centre >>>

Great Lakes Data Room Case Study

Data Center Infrastructure Management. Experience the inner calm that comes with successful data center management.

EIGHT STEPS FOR ENSURING PCB DESIGN SUCCESS DANIT ATAR AND ALEX GRANGE, MENTOR GRAPHICS

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

L293B L293E PUSH-PULL FOUR CHANNEL DRIVERS. OUTPUT CURRENT 1A PER CHANNEL PEAK OUTPUT CURRENT 2A PER CHANNEL (non repetitive) INHIBIT FACILITY

TEL: +44 (0) FAX: +44 (0)

Programming Matters. MLC NAND Reliability and Best Practices for Data Retention. Data I/O Corporation. Anthony Ambrose President & CEO

Discontinued Product For Reference Only

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

MASW TB. GaAs SPST Switch, Absorptive, Single Supply, DC-4.0 GHz. Features. Pin Configuration 1,2,3,4. Description. Ordering Information

PIN IN PASTE APPLICATION NOTE.

FM Radio Transmitter & Receiver Modules

Your guide to Buying an Industrial-grade Computer or a Server

Cisco Nexus 7000 Series.

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Ultra Reliable Embedded Computing

Pololu DRV8835 Dual Motor Driver Shield for Arduino

DATA CENTER ASSESSMENT SERVICES

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Cisco Nexus 7000 Series

Cable management for rack-mounted systems

How to avoid Layout and Assembly got chas with advanced packages

Last Time Buy. Deadline for receipt of LAST TIME BUY orders: April 30, 2011

Multilevel Socket Technologies

Transcription:

Temperature-Aware Design of Printed Circuit Boards Co-design of PCBs for electrical, mechanical and thermal engineers Based on EDA Design for Manufacturing Flows CDNLive 2007 Dirk Niemeier Support Manager Flomerics Ltd.

AGENDA Drivers for temperature - aware design Impact on PCB design Making the Allegro design flow temperature - aware Case Study Summary & Conclusions

Drivers for Temperature Aware Design Market forces Functionality Performance Time to market Product requirements Form factor Parts count Speed Physical design challenges Packaging/ thermal density Signal sensitivity Design margin Design quality Temperature aware design Cost $

Product Requirements Designs are complex High transmission speeds High PCB layer count High pin count ASICs Embedded passives Daughter cards Extensive heat sinking Design margins are small, risk is high Performance, reliability are compromised 80-90% of nets are constrained, restricting component placement Heat sinks are large and complex, requiring placement flexibility Design closure is difficult and costly Signal integrity, thermal & component placement requirements clash Co-design is critical Performance is being impacted

Physical Design Challenges: Five Year Thermal Density Trends* Datacenter Rack System/PCB IC/package 900% *Flomerics customer survey data 500% 300% 100%

Temp. Analysis The Next Logical Step Physical Design Challenges: Industry Perspective FLO/EMC EMC Physical Functional FLO/PCB Signal Integrity Temperature Temperature Signal Integrity Temperature Temperature Signal Integrity Routing Routing Routing Routing ~ 100MHz ~ 1 GHz ~ 10 GHz 1995 2000 2006 2010

Physical Design Challenges Components @ 120 ºC PCB power densities are reaching 1.5 W/in 2 for high speed applications At this level, the PCB has reached its heat sinking limit Thermally unworkable designs are common 20% of Flomerics customers have reached this threshold and the percentage is rising The industry in general can see the approaching threshold PCB at 1.5 W/in 2, 1 m/s

How Effective is a PCB as a Heat Sink? 15 x 8 PCB, 180 W, 1 m/s airflow Temperatures Temperatures increase increase as as power power dissipation dissipation areas areas shrink shrink Power dissipated on 12 small components Power evenly dissipated

How Effective is a PCB as a Heat Sink? 15 x 8 PCB, 180 W, 1 m/s airflow Heat Heat sinks sinks solve solve the the thermal thermal problem problem without without impacting impacting layout layout Heat sinks added

How Effective is a PCB as a Heat Sink? High High temperatures temperatures due due to to high high power power density density components components 15 x 8 PCB, 180 W, 1 m/s airflow Heat Heat sinking sinking is is to to more more complex complex Real world PCB Idealized PCB

Heat Sink Design Issues at the Threshold Over-sized heat sink Multicomponent heat sinks Interferences are common, heat sinks are heavy Heat sinks must be mounted to the PCB Assembly is more complicated Components may run hot

LOGIC DEFINITION Traditional PCB Design *3-5 days response time Footprint library Mechanical packaging Floor Floor planning and and constraints Thermal design PCB design PCB design

Traditional PCB Design Thermal Solution Design Requirements Junction temperature Shock and vibration Cost Mechanical fit Parts availability System level performance

Traditional PCB Design Attempt is made to meet cooling requirements by heat sinking based on design constraints Ref. Des. Component Power Dissipation Maximum Case Temperature ( o C) Predicted Case Temperature ( o C) Margin ( o C) U3 3 75 65.3 9.7 U4 7 75 107 32 U5 17 80 80.4 0.4 Larger heatsinks cannot be placed due to real estate problems Components are still operating above their required case temperature limit Use of Cu heatsink instead of cheaper, lighter heatsink (aluminum)

Temperature-Aware PCB Design LOGIC DEFINITION Footprint library 20-60 min response time! Floor Floor planning and and constraints Thermal design PCB design PCB design

Temperature-Aware PCB Design Bi-directional model transfer High-degree of automation Model transfer and filtering Model-set up Solver automation Results viewing and interpretation Intuitive user control Drag n Drop model modification SmartParts Intelligent modeling rules Interactive 3D viewing The time to complete the loop from SI constraints to thermal design, back to SI constraints must be completed in minutes Traditional loop response time 3-5 days Temperature aware response time 20-60 minutes

Case Study of a Temperature-Aware Design Flow

SI Constraints -> Thermal Design Constraints are set in Allegro PCB SI Launch thermal tool from within Allegro PCB SI Board Information, Component Footprints/Height etc are filtered and passed into FLO/PCB

SI Constraints -> Thermal Design Component filter allows for only the critical components to be passed

FLO/PCB User Interface: Designed for Quick Thermal Verification Four steps to model creation and analysis SmartParts 1 2 3 4 3D model Property sheet input

Layout 1 Variant Definition 1. Heatsinks added to thermally critical components Check mechanical fit 2. Proposed thermally optimized layout manually defined in thermal tool 3. Ensure that appropriate up-to-date power dissipation values are entered 4. Select the environment in which the design is to operate, e.g. card slot 5. Perform a thermal prediction and inspect results Response time: 20 minutes!

Layout 1 Variant Results Ref. Des. Component Power Dissipation Maximum Case Temperature ( o C) Predicted Case Temperature ( o C) Margin ( o C) U3 3 75 57.5 17.5 U4 7 75 80.3 5.3 U5 17 80 66 14 Temperature Contour (thru the board) Velocity Contour (3 mm above board)

Layout 2 Variant 1. Critical component moved in an attempt to decrease its case temperature 1. Check mechanical fit 2. All other settings retained 3. Perform a second thermal prediction! Response time 10 minutes

Layout Variants PCB properties Layers Copper patches Material properties (Stablecor) Thermal vias PCB layout Heat sinks Environmental conditions Airflow Air temperature

Layout 2: Results Ref. Des. Component Power Dissipation Maximum Case Temperature ( o C) Predicted Case Temperature ( o C) Margin ( o C) U3 3 75 57.2 17.8 U4 7 75 75.8 0.8 U5 17 80 66.3 13.7 Temperature Contour (thru the board) Velocity Contours (3 mm above board)

Back Annotate the Proposed Design Soft update using report generation feature EDA tool updated with thermally optimized layout from thermal tool Multiple violations found by constraint manager SI rules must be revisited The new layout can then again be passed into thermal tool, automatically updating the existing model definition

Fast Response Time 20 minutes for: Data transfer Thermal model set up Solution Results processing Report generation Back annotation Four design variants

Summary & Conclusions Temperature aware design makes SI, thermal and mechanical considerations an integral part of pre-route floor planning Enough thermal detail is considered to close the floor plan design Thermal validation can be performed by EE or ME, depending on response time requirements Thermal closure is typically the responsibility of the thermal engineer

Summary & Conclusions Temperature aware design is possible through design tool automation Bi-directional compatibility All thermal data stored in Allegro database Intuitive user interface High-degree of modeling and results processing automation Temperature aware design is interactive and dynamic as compared to traditional over the wall thermal design Common data transfer mistakes and oversights are eliminated All players are working at the same rate and are synchronized Design space for SI, mechanical and thermal closure is maximized Overall design time and effort is minimized

Summary and Conclusions Reduce risk of late-cycle redesign by fully considering thermal requirements before routing Reduce communication bottlenecks and errors between electrical and mechanical engineers Increase data reuse by leveraging the EDA database for thermal design Reduce overall design cost and increase quality by opening design space SI Thermal Mech Traditional Design space Temperature Aware