Opiates in Urine by SAMHSA GC/MS



Similar documents
Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

How To Test For Contamination In Large Volume Water

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Oasis HLB Cartridges and 96-Well Plates

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

Innovative vs Traditional

Cannabis Analysis: Potency Testing Identification and Quantification of THC and CBD by GC/FID and GC/MS

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

SCREENING FOR THE PRESENCE OF PARA-METHYLTHIOAMPHETAMINE IN URINE BY SOME COMMERCIAL IMMUNOASSAYS AND CONFIRMATION BY GC/MS

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

CORESTA RECOMMENDED METHOD N 72

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Tandem mass spectrometry: a helpful tool in hair analysis for the forensic expert

SOLID PHASE EXTRACTION APPLICATIONS MANUAL

Analytical Test Report

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Interlaboratory Studies on the Analysis of Hair for Drugs of Abuse: Results from the Fourth Exercise

Analyzing Small Molecules by EI and GC-MS. July 2014

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

Clarus 580 Gas Chromatograph

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Protocol: HPLC (amino acids)

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

The basic division explosives for forensic purposes is shown in Fig. 1

Expectations for GC-MS Lab

Analysis of Liquid Samples on the Agilent GC-MS

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Practical Aspects of Drug Testing in Human Hair

Analysis of Drugs by using the Ultra Inert Inlet Liners with Wool

Technical Note. Introduction. Edward J. Cone. Lance Presley, Michael Lehrer, William Seiter, and Melissa Smith

GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

AppNote 6/2011. Determination of Pain Management Drugs using Automated Disposable Pipette Extraction and LC-MS/MS KEYWORDS ABSTRACT

Chromium Speciation in Drinking Water by LC-ICP-MS

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

Pennsylvania Hospital & Surgery Center ADMINISTRATIVE POLICY MANUAL

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

FATAL INTOXICATION BY CIBENZOLINE (CIPRALAN )

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

Purification of reaction mixtures using flash chromatography.

Confirmation by Triple Quadrupole LC/MS/MS for HHS-compliant Workplace Urine Drug Testing

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

SCION SQ Series GC-MS

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

ORGANIC SAMPLE PREPARATION

SUCRALOSE. White to off-white, practically odourless crystalline powder

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Forensic Drug Testing For Opiates. V. Urine Testing for Heroin, Morphine, and Codeine With Commercial Opiate Immunoassays

CLEAN-UP PROCESS FOR MASS SPECTRAL STUDY OF AMPHETAMINES IN PUTREFIED BODY MATERIALS

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Analysis of Phthalate Esters in Children's Toys Using GC-MS

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

The Use of Hydrogen Carrier Gas for GC/MS

Hillsborough Community College - Ybor City Campus 1025C Laboratory Exercise 9: Testing Urine for the Presence of Drugs Introduction

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Transcription:

application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Opiates in Urine by SAMHSA GC/MS Introduction The United States Department of Health and Human Services (DHHS), Substance Abuse and Mental Health Services Administration (SAMHSA) regulates urine drug testing programs in the mandatory guidelines for the Federal Workplace Drug Testing Program. These Mandatory Guidelines require a laboratory to conduct two analytical tests before a urine specimen can be reported positive for a drug, the initial drug test and the confirmatory drug test. The initial drug test is performed by immunoassay screening for the five drug classes (i.e., amphetamines, cocaine, opiates, phencyclidine, and marijuana). Examples of immunoassay screening would include radioimmunoassay (RIA), enzyme immunoassay (EIA, EMIT) or others. Samples found positive to the immunoassay screening are subjected to a second confirmatory test by chromatographic separation and identification by mass spectrometry. SAMHSA defines the method quantification cutoff level as 2000 ng/ml each for codeine and morphine. If morphine is detected above 2000 ng/ml, then an additional quantification for 6-acetylmorphine is suggested. 6-AM is a unique metabolite indicating the use of heroin. 6-AM cutoff level is 10 ng/ml.

The general procedure for drug confirmatory test in urine follows the 7 steps listed below: 1. Add a deuterated internal standard to the urine. 2. Adjust urine ph. 3. Hydrolyze urine (opiates and cannabinoids only). 4. Extract drugs from urine using solid phase extraction (SPE), evaporate to dryness. 5. Derivitize the extract (except for PCP), evaporate to dryness. 6. Reconstitute extract into organic solvent. 7. Inject 1-3 µl into gas chromatograph/mass spectrometer for identification and quantitation using three ion ratio reporting software. Glassware All glassware, including autosampler vials and low volume vial inserts must be silanized to prevent adsorption of sample. Soak all glassware in 10% DMDCS/Toluene for 10 min. Rinse in methanol, rinse in hexane, air dry. Reagents list Beta-glucuronidase Sodium Hydroxide Hydrochloric Acid (conc.) Acetic Acid, 100 mm = 2.86 ml glacial acetic acid diluted to 500 ml DI water Phosphate buffer, 100 mm ph6 = 1.7 g Na 2HPO 4 + 12.14 g Na 2PO 4 dilute to 1000 ml with DI water. Adjust to ph6 with 100 mm Na 2HPO 4 (raises ph) or 100 mm Na 2HPO 4 (lowers ph). Methylene Chloride/Isopropanol/Ammonium Hydroxide (78:20:2) extraction solvent = 40 ml IP-OH + 4 ml con NH 4OH + 156 ml MeCl 2. Make fresh daily. Drug standards and deuterated internal standards are available from Cerillant (Round Rock, TX). Internal standard: d3-codeine, d3-morphine, d3-6-acetylmorphine. Instrumentation Gas Chromatograph: PerkinElmer Clarus 680 GC Injector: Capillary injector using pressure pulsed splitless injection, 250 C. Injection port liner: Siltek with wool (Cat No. N6502010). GC Column: Elite-5 (5%Phenyl/95% Methyl Silicone) 12 m x.200 mm x 0.33 µm (Cat No. N9316110). Helium carrier 2 ml/min GC oven: Start temperature 100 C hold for 0.5 min, then 20 C/min to 310 C hold 4 min. Pressure pulsed, splitless injection This procedure raises the injector pressure during the injection process to put more sample onto the column in a narrow band and then reduces the carrier gas to normal operational linear gas velocity for chromatography. This is accomplished with timed events such as the following: CAR2 set to 5 ml/min at -0.71 min (raise pressure before injection). SPL2 set to 0 at -0.70 min (splitless injection). CAR2 set to 2 ml/min at 0.7 min (operating flow after injection). SPL2 set to 50 at 0.8 min (open split vent after injection). Mass Spectrometer PerkinElmer SQ8 MS, 270 L/sec turbomolecular pump, EI mode. All data is collected in selected ion monitoring mode (SIM) acquiring 20-30 msec per ion. A primary ion is used for identification and quantitation while 2 additional ions are used for confirmation of identification. Three ion ratio chromatograms must all apex within ±2 scans of standard retention time. Ion ratios must fall within ±20% of standard ratios. Deuterated internal standards may use only 2 ions, a primary ion and only 1 confirmation ion. 2

PFPA SIM ions: Codeine: 282,445, 446 d3-codeine: 285, 448 RT: 7.16 min Morphine: 414, 430, 577 d3-morphine: 417, 580 RT: 7.35 min 6-acetylmorphine: 414, 361, 473 d3-6-acetylmorphine: 417, 479 BSTFA SIM ions: Codeine: 371, 234, 343 d3-codeine: 374, 237 Morphine: 429, 287, 324 d3-morphine: 432, 290 Solid Phase Extraction Drugs are extracted from the urine sample matrix by solid phase extraction (SPE) with a polymeric resin cartridge. The drugs are retained as the urine is passed through the resin bed. Washing the bed can remove salts and other contaminants. Eluting the drugs off the resin bed with a stronger solvent completes the cleanup process from the urine. Extraction cartridges used were Supra-Clean SPE Columns C18-S 200 mg/3 ml 50 u (Cat No. N9306462). Hydrolysis Hydrolysis is necessary in some drugs to remove glucuronide bonding which prevents the solubility and extraction of the drug. This preparation before extraction is usually accomplished either by enzyme or acid hydrolysis of the sample. Both procedures are outlined below. Enzyme Hydrolysis Procedure Combine 3-5 ml urine sample with ISTD and 2 ml betaglucuronidase, vortex, heat 3 hours at 65 C. Cool, centrifuge, decant and keep top layer. Adjust ph to 6.0 with 700 ul 1.0 N NaOH. Acid Hydrolysis Combine 3-5 ml urine sample with ISTD and 500 ul concentrated HCl, vortex, heat 30 min at 120 C. Cool, centrifuge, decant and keep top layer. Add 1 ml 7.4 N NH 4OH, vortex. Adjust ph to 6.0 with 1-3 ml of 500 mm phosphoric acid. Experimental Extraction Procedure: 3 ml urine + ISTD. Hydrolyze sample to break glucuronide bonding. SPE column extract: Condition column with 3 ml methanol, then 3 ml DI water, then 1 ml 100 mm phosphate buffer ph6. Extract sample, wash column with 3 ml DI water, then 1 ml 100 mm Acetic Acid, then 1 ml methanol. Elute column with 3 ml Methylene chloride:isopropanol: Ammonium Hydroxide (78:20:2) into conical tube. Evaporate to dryness <50 C. Derivitize with 50 ul PFPA, add 25 ul PFPOH. Cover with N2, cap, mix, heat 70 C (20 min). Evaporate to dryness <50 C. Reconstitute in 100 µl ethyl acetate, transfer to low volume autosampler vial insert, inject 1 µl. Alternative Derivitization Procedure Reconstitute dried extract with 50 ul ethyl acetate, add 50 ul BSTFA with 1% TMCS. Cover with N2, cap, mix, heat 70 C (20 min), cool, do not evaporate, inject BSTFA solution directly. Calibration Range 10% cutoff (200 ng/ml), 40% cutoff (800 ng/ml), 100% cutoff (2000 g/ml), 125% cutoff (2500 ng/ml), 500% cutoff (10000 ng/ml), 1000% cutoff (20000 ng/ml) 3

Results Limit of Quantitation: 20 ng/ml from 1mL urine. Limit of Detection: < 2 ng/ml from 1 ml urine. Linear Correlation coefficient (R 2 ) >0.999 20 ng/ml 20000 ng/ml. Results for 6-acetylmorphine PFP 4

Conclusion The GC/MS analysis of codeine and morphine in this application has demonstrated the limit of quantitation at or below 20 ng/ml in urine a 10 fold factor lower than the limit of quantitation requirements of the Federal Workplace Drug Testing Program. Forensic and clinical laboratories can use the same method for toxicology samples in non-regulated drug testing. Fast sample throughput was increased through the use of a short GC column, fast flow rate into the mass spectrometer, very fast cooling GC oven and autosampler pre-rinsing options. The PerkinElmer SQ8 GC/MS system operating in SIM mode provided the sensitivity and spectral data necessary to generate legally defensible results. The TurboMass GC/MS software includes the reporting capability required to present three-ion-ratio data in a format that is simple and easy to understand. An example of a customizable three-ion ratio report. References 1. Disposition of Toxic Drugs and Chemicals in Man, 8th Ed, Randall C. Baselt, Biomedical Publications, 2008. 2. Mandatory Guidelines for Federal Workplace Drug Testing Programs, Fed Reg, 73: 71857 (Nov 25, 2008). 3. Mandatory Guidelines for Federal Workplace Drug Testing Programs, Fed Reg, 75: 22809 (April 30, 2010). 4. Pierce Catalog (Rockford, IL). PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2011, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009816A_01