SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES



Similar documents
UDSA - UDSBD unit heater

ECOCIAT. Domestic hot water heat recovery unit

SIOUX HYBRID WATER HEATER

LG Electronics AE Company, Commercial Air Conditioning

Hot Water. Heat pump water heaters. Residential and Commercial R410a

HEAVY DUTY STORAGE GAS

FOREWORD LEGEND FUEL TYPE MMD Equipment

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Cooling kw Heating kw

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Electric Flow Boiler

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

RPV - RP - RA air handling units

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

Daikin Altherma hybrid heat pump. The natural combination

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Session 2: Hot Water Supply

Conlift1, Conlift2, Conlift2 ph+

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Daikin Altherma Hybrid Heat Pump

SWIMMING POOL HEAT PUMP Owners Manual

We have been working in an ideal climate for thirty years.

- White Paper - Data Centre Cooling. Best Practice

High-efficient gas boiler CompactGas

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

york air-conditioning products Residential & VRF News 2015

The Complete Air Conditioning Guide

Daikin Altherma Hybrid Heat Pump

Link-Up. Solid Fuel Association Guide to Central Heating.

HIGH QUALITY COMPONENTS

PRODUCT CATALOGUE

Top Technology for Industry, Agriculture, Business and Communities

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Daikin Altherma Hybrid Heat Pump

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

HP switch LP switch Discharge thermo Comp. Surface thermo

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Screw Compressors ESM Fixed Speed & VS Variable Speed

Continuous flow direct water heating for potable hot water

Product Overview Benefits

Commercial Gas Furnace Upflow

Energy Efficiency HOSPITALITY.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Half the cost Half the carbon

Meaco 30L and Meaco 40L dehumidifier instruction manual

Condensing Boiler Efficiency

Material test chamber with mechanical convection

Instructions for designing heating systems.

Portable Air Conditioner

TECHNICAL SPECIFICATION TYPE ATESO ALFA

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

ELECTRIC CENTRAL HEATING FLOW BOILER

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Operating instructions

FTQ. Daikin Inverter Ducted Heat Pump

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Important Safeguards

The natural ombination

Endless Hot Water 24/7

Incubator with mechanical convection

Energy Efficiency. Bars & RestauRants.

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

HVAC Systems: Overview

Hybrid heat pumps. saving energy and reducing carbon emissions

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

Refrigeration Compressed Air Dryer Buran Ultrapulse

Versati Air to Water Heat Pump

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

FULL DC INVERTER SYSTEMS

Vaillant s plain English guide to. simple, concise and precise

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Magnum Mobile Generator MMG55 Specifications

USER S MANUAL HSC-24A

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Technical data. Danfoss DHP-A

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

MEMBRANE VACUUM MINI PUMPS

The kva RAnge

KONRAD. Hybrid Fancoil Series

Itho Products for Hot and Boiling water. product-

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Data Center Components Overview

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

MovinCool Office Pro Series. The Portable Spot Cooling Solution

AIR DEHUMIDIFYING Condensation drying for industry and trade

Waste Oil Handling, Spill Containment & Lighting

E. Fowler & Sons Ltd.

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Transcription:

SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES Electric, IDF, Gas & Oil Fired Technology Heating Capacity 2.0-2,000kW

ICS Cool Energy Hire Division The hire division of ICS Cool Energy is your 24/7 temperature solutions provider, offering a leading range of temperature control equipment. ICS Cool Energy work alongside their customers to recommend the most energy and cost-effective solutions available on either a shortterm, long-term or permanent basis throughout the UK. Whilst specialising in temperature control rental, ICS Cool Energy also has a great selection of portable heating solutions ideally suited for office, warehouse and industrial requirements. The range is ideally suited for providing supplementary winter heat for a host of requirements. In many cases customers are working to very tight deadlines. In order to meet these urgent requirements, ICS Cool Energy hold a large number of units in stock, which are available for same day rental or purchase where required. To support customers further a network of Rental Application Engineers can support customers with on-site technical advice without any obligation. Just call to arrange a visit on 0800 774 7410. 2

FAQ s Performance Q. How much heating do I get from a single portable heating unit? A. We can offer units from as little as 2kW to create a comfortable environment for 2 people in one office. Q. If we have insufficient units will they work and control the office temperature? A. For best results in all weather conditions the correct number of portable heating units should be used. If fewer are installed then on the coldest days the office or warehouse temperature will drop. Q. How much maintenance do these units need once installed? A. There is a basic weekly maintenance procedure involving simply making sure that the air inlets are free from obstruction and dust, which needs to be carried out to ensure the unit works to its full potential. Q. How much noise do the portable units make? A. Most portable heating units have a choice of fan speeds or are completely silent. At the highest speed the fan noise would normally be lost in the background noise of a busy office. At lower speeds the unit is scarcely audible. Location, Installation & Services Q. Where should we position the portable heating units? A. You will need to position heaters in an uncluttered area away from obstructions and not too close to the area to be heated. Q. What size is the air exhaust? A. This can range from 125mm in diameter and up to 250mm diameter. Q. What power supply is needed for portable heating units? A. A standard 13amp supply and standard plug is needed for our smaller 2kW units, and an extension lead can be used if one is not available close by. Our larger 13-42kW would require a 3phase power supply. Our engineers would be happy to discuss this with you. Q. How much power do these units use? A. Approximately 100% of the heating kw value of each unit. Q. Does a temporary heater/heating unit run all the time? A. No. There is an integral thermostat, which turns off and on the unit when the required room temperature is reached. 3

4

Contents Office Heating Solutions 2.0kW Convector Heater 7 2.0kW Portable Radiator 8 12kW Electric Fan Heater 9 20kW Electric Fan Heater 10 Warehouse Heating Solutions Electric Warehouse Heaters 3kW 13 Electric Warehouse Heater 9kW 14 Electric Warehouse Heater 22kW 15 Electric Warehouse Heater 42kW 16 129kW Rooftop Unit 17 Industrial Heating and Hot Water Hot Water Packages (HWP) 19 20kW Hot Water Package 20 40kW Hot Water Package 21 150kW Hot Water Package 22 300kW Hot Water Package 23 600kW Hot Water Package 24 1,000kW Hot Water Package 25 2,000kW Hot Water Package 26 Air Handling units for HWP s 27 70kW Indirect Fired Heater 28 110kW Indirect Fired Heater 29 200kW Indirect Fired Heater 30 910 Litre Fuel Cube 31 2900 Litre Fuel Cube 32 5

Office Heating Solutions ICS Cool Energy s hire division offer a range of portable heaters ready for hire which are the fastest and most convenient way to provide local heat to your business, event or commercial environment. ICS Cool Energy offer a portable electric range which are quick and easy to install and effectively manage cold spots throughout an office or continuous chills in receptions areas and customer/public spaces where doors are regularly opened. Not only are units light weight, quiet and portable but they simply plug in with a standard 13amp plug socket and work instantly. 6

Convector Heater 2.0kW Features This compact portable convector heater with integral thermostat, is easy to operate and small enough to conveniently fit in small areas, ideal for offices, retail outlets and workplaces. The ICS Cool Energy 2.0kW unit has 3 heat settings and operates from a standard 13amp single-phase supply and has a adjustable thermostat to help safely manage the heat in a specific area. In addition to this, the unit is entirely portable and has a carry handle. This allows for easy movement when cleaning around the lightweight unit. Dimensions mm (L)520 x (W)425 x (H)585 Weight Kg 2.9 Heat kw 2.0 Heat Settings - 3 Current consumption Amps 11 Power supply - 220/240/1/50 (1.5mm 2 ) Max power absorbed kw 2.0 Power coections - 13 amp standard plug Operating Costs (based on 11p/kW/hr) Low = 9p Med =14p High =22p Safety cut out Carry handle Yes Yes 7

Portable Radiator 2.0kW Features This compact portable oil-filled radiator with integral thermostat, is easy to operate and small enough to conveniently fit in small areas, ideal for offices, retail outlets and workplaces. The ICS Cool Energy s 2.0kW unit has 3 heat settings and has been designed for a fast rental installation. The unit operates from a standard 13amp single-phase supply and has an adjustable thermostat to help safely manage the heat in a specific area. In addition to this, the unit is entirely portable and has a carry handle. This allows for easy movement when cleaning around the lightweight unit. Dimensions mm (L)245 x (W)420 x (H)630 Weight Kg 15.4 Heat kw 2.0 Heat Settings - 3 Current consumption Amps 11 Power supply - 220/240/1/50 (1.5mm 2 ) Max power absorbed kw 2.0 Powercoections - 13 amp standard plug Castors Adjustable thermostat Safety cut out Carry handle Yes Yes Yes Yes 8

Electric Fan Heater 12kW Features This compact, portable and powerful heater features an integral thermostat and a powerful airflow rate of 1200m 3 /hr. The unit is simple to operate and compact in design making it suitable for both small and large offices as well as industrial workspaces. ICS Cool Energy s 12kW heater offers a high level of durability, operating from a 16amp plug whilst remaining completely portable and lightweight. Dimensions mm (H)444 x (W)390 x (D)382 Weight Kg 15 Heat kw 12.7 Airflow Rate m 3 /hr 12,000 Temp Increase ΔT 48 C Power Supply - 400v 16a 3ph Heat Capacity Btu s 43332 Max Heat Capacity kcal 1111 Sound @3m 55dB(A) Safety Cut Out Thermostat Carry Handle Yes Yes Yes 9

Electric Fan Heater 20kW Features This compact, portable and powerful heater features an integral thermostat and a powerful airflow rate of 1850m 3 /hr. The unit is simple to operate and compact in design making it suitable for both small and large offices as well as industrial workspaces and warehouse heating requirements. ICS Cool Energy s 20kW heater offers a high level of durability, operating from a 32amp plug whilst remaining completely portable and lightweight in design. Dimensions mm (H)460 x (W)290 x (D)483 Weight Kg 20 Heat kw 20 Airflow Rate m 3 /hr 1850 Temp Increase ΔT 50 C Power Supply - 400v 32a 3ph Heat Capacity Btu s 68240 Max Heat Capacity kcal 17497 Sound @3m 60dB(A) Safety Cut Out Yes Thermostat Carry Handle Yes Yes 10

11

Warehouse Heating Solutions ICS Cool Energy s hire division offer portable electric range (3kW 42kW) of plug and use units to help provide safe heat and are ideal for warming office areas, shops, stores, marquee structures, industrial workplaces and where there is a need for localised heating fast. These systems are quick and easy to install and effectively manage cold spots throughout a warehouse or factory area. Heat is instantly and easily achieved; they simply plug in with a standard 13amp plug socket and work instantly. Furthermore units within the warehouse heating range are light weight, quiet and portable. 12

Warehouse Heater 3kW Electric Warehouse Heater Features ICS Cool Energy s electric heating range is entirely portable and fast to install, providing heat within seconds. ICS Cool Energy s rental heaters are available in four duties 3kW, 9kW, 22kW, and 42kW the systems are ideally suited to heat warehouses, production and storage areas. All units within this range are free -standing unit and offer a consistently high level of air flow directing warm air to specific areas by utilising air ducts situated in the front of the unit. Dimensions mm (H)360 x (W)300 x (D)330 Weight Kg 10 Air flow rate m 3 /hr 423 Pressure Pa 80 Fan Type - Radial Heat Capacity kw 3 MaxHeatCapacity kcal 2,625 Temp Increase ΔT 40 C Supply - 230v 50hz Max Current A 12 Sound @3m 45dB(A) Spigot Φ 200mm Mobility - Portable Thermostat - Optional Overtemp Protection - Yes PhaseProtection - N/A Max Ducting m N/A Effective Area m 3 72 ft 3 2,534 Castors - Yes Plug Size & Type - 13A BS1363 13

Warehouse Heater 9kW Electric Warehouse Heater Dimensions mm (H)380x(W)30x(D)450 Weight Kg 18 Air flow rate m 3 /hr 1,017 Pressure Pa 400 Fan Type - BC Impellor Heat Capacity kw 9 MaxHeatCapacity kcal 12,161 Temp Increase ΔT 49 C Supply - 400v 50hz Max Current A 12 Sound @3m 55dB(A) Spigot Φ 200mm Mobility - Portable Thermostat - Optional Overtemp Protection - Yes PhaseProtection - No Max Ducting m 15 Effective Area m 3 102 ft 3 3,590 Castors - Yes Plug Size & Type - 5 Pin 16A BS4343 14

Warehouse Heater 22kW Electric Warehouse Heater Dimensions mm (H)570 x (W)400 x (D)520 Weight Kg 36 Air flow rate m 3 /hr 2,034 Pressure Pa 400 Fan Type - BC Impellor Heat Capacity kw 22 MaxHeatCapacity kcal 25,284 Temp Increase ΔT 55 C Supply - 400v 50hz Max Current A 22 Sound @3m 57dB(A) Spigot Φ 250mm Mobility - Portable Thermostat - Optional Overtemp Protection - Yes PhaseProtection - No Max Ducting m 20 Effective Area m 3 696 ft 3 24,500 Castors - Yes Plug Size & Type - 5 Pin 32A BS4343 15

Warehouse Heater 42kW Electric Warehouse Heater Dimensions mm (H)1000 x (W)700 x (D)1100 Weight Kg 130 Air flow rate m 3 /hr 4,000 Pressure Pa 600 Fan Type - Radial Heat Capacity kw 21/42 MaxHeatCapacity kcal 36,745 Temp Increase ΔT 60 C Supply - 400v 50hz Max Current A 62 Sound @3m 73dB(A) Spigot Φ 500mm Mobility - Portable Thermostat - Optional Overtemp Protection - Yes PhaseProtection - Yes Max Ducting m 30 Effective Area m 3 1,008 ft 3 235,482 Castors - Yes Plug Size & Type - 5 Pin 63A BS4343 16

Rooftop Unit 129kW Ventilation Unit/ Air Conditioning/Heat Pump Features Cool RTH 115 HP is a ventilation unit with integrated chiller and heat pump providing ventilation through flexible ducting which can be installed into a pre-existing site distribution networks. The system is suitable for installation on rooftops and load bearing floors and is designed for external positioning. The heat pump chiller can be used for exhaust and recirculation and where required controlled by an external thermostat. The large fan enables a powerful air movement of 18,000 m 3 /h which can offer heating as well as cooling thanks to the chiller/heat pump combination. This 129kW compact ventilation unit, with its high pressure circuit, provides the best conditions for many types of air-conditioning applications. With 4 adapters (2x supply, 2x outside air) for 500 mm air hoses a consistent distribution of air is ensured. Plug & Play - Set up, power supply, manufacture, coect air hoses - simply air conditioning. Dimensions Weight NominalCooling Capacity (L)2.330 x (W)2.330 x (H)2.420 mm 1.960 Kg 129kW at 35 C ambient temperature and35 Creturnairtemperature NominalHeating 105kW at 0 C ambient temperature and18 Creturnairtemperature Compressor 2 Cooling Circuits 1 Air Flow Max. 18,000 m 3 /h (frequency controlled) ExternalPressure 80 350 Pa Power Maximum Operating Current Electrical Coection Sound Pressure Level 400 V / 50 Hz / 3 Ph 94 A* CEE 125 A 63 db (A) @ 10 m when operating at full load * If a Residual Current Device (RCD) is used, it has to be RCD type B (AC-DC sensitive). Manufacturers data. subject to change without notice / fig. similar. 17

Industrial Heating and Hot Water Packages ICS Cool Energy s hire division offer a powerful range of industrial hot water packages from 3kW to 2,000kW these systems are especially suited to building refurbishments or to replace systems during services or breakdowns. ICS Cool Energy s hire units offer emergency boiler replacements on either long or short term basis to suit a sites needs. The rental system offer the latest environmentally-friendly option of ruing off Bio-Fuel or, alternatively, Standard Diesel Fuel or Gas, furthermore all equipment is supplied with internal or external fully-bunded fuel tanks to ensure you or your clients site is safe from a fuel spillage. 18

Hot Water Packages Features ICS Cool Energy s rental hot water packages are housed within a steel container enabling external siting and increased protection from environmental elements. The container also aides with portability as the unit can easily be positioned with a fork-lift unit and coected to a customers system, ensuring a fast rental set-up. The compact system is powerful in design offering low pressure hot water for demanding requirements. The units feature a group pump with mixer and motor as well as a double walled stainless steel waste gas chimney (approx 1m from the top edge of the container as shown above). The unit is designed for reliable and safe operation with flexible hoses resistant up to 7Bar pressure and resistant to temperatures up to 100 o C. Furthermore the unit features safety devices and system protection. Other features within the unit include, a diaphragm expansion tank and frost protection. 19

Hot Water Package 20kW Features The unit features: Integrated frost protection Operating temperature of 20-80 (90) C 3 Stage heating: 3/11/19kW 3 different power supply options: 230V16A, 400V16A, 400V32A Units are equipped with advanced safety features including membrane expansion tank, pump temperature controller, safety temperature limiter, safety valve and residual current protection switch Dimensions mm (W)600 x (D)550 x (H)1,220 Weight (including trolley) kg 55 Heating Capacity kw 3kW (1) / 11kW (2) / 19kW (3) Temperature Range C 20 80 C Control - Digital Circulation Pump - 2 m 3 / h Type of Heating Pump - GHN 25/60 Heating Coection - DN25/ 1 Camlock DN25 Volume of Expansion Tank Litre 10 System Safety Rating - IP 54 Recommended Operating Pressure Bar 1.5 2.0 Bar (Safety Valve is 3.0 Bar) Power Supply - 230 V / 50 Hz / 1 ~ (1) 400 V / 50 Hz / 3 ~ (2 & 3) Electrical Coection - Standard Plug (1) / CEE 16A (2) / CEE 32A (3) 20

Hot Water Package 40kW Features The unit features: Integrated frost protection Operating temperature of 20-80 (90) C 3 Stage heating: 8/16/40kW n n Units are equipped with advanced safety features including membrane expansion tank, pump temperature controller, safety temperature limiter, safety valve and residual current protection switch Dimensions mm (W)670 x (D)550 x (H)1,260 Weight (including trolley) kg 63 Heating Capacity kw 8 kw (1)/ 16 kw (2)/ 40 kw (3) Temperature Range C 20 80 C Control - Digital Circulation Pump - 2 m 3 / h Type of Heating Pump - GHN 25/70 Heating Coection - DN25/ 1 Camlock DN25 Volume of Expansion Tank Litre 12 System Safety Rating - IP 54 Recommended Operating Pressure Bar 1.5 2.0Bar(SafetyValveis3.0Bar) Power Supply - 400 V / 50 Hz / 3 ~ (1, 2& 3) Electrical Coection - CEE 16A (1)/ CEE 32A (2)/ CEE 63A (3) 21

Hot Water Package 150kW 6 4 1 2 Swing door with revolving rod closure Heat Container 1 3 4 Hatch to inspect gases Chimney 2 3 5 6 Forklift Pockets ISO Corners for lifting 5 Dimensions mm (W)1,650x(D)2,550 x (H)2,800 Weight Tons 2 (approx.) Heating Power kw 150 Heating Mode o C 20-90 Temperature (in flow/ return flow) o C 90 / 70 WaterCoections - 2 /DN50 RegulationControl o C 20-90 (105) High-Efficiency Pump Low-Temperature Boiler - 22/8-9 Oil Burner - 50-100% Oil Tank Container Litre 1 x 1,000 Safety Valve Bar 3 MAG Capacity Litre 200 Power Supply - 230V/50Hz/1phase Electrical Supply - CCE 16 A 22

Hot Water Package 300kW 6 4 1 2 Swing door with revolving rod closure Heat Container 1 3 4 Hatch to inspect gases Chimney 2 3 5 6 Forklift Pockets ISO Corners for lifting 5 Dimensions mm (W)1,650x(D)2,400 x (H)2,400 Weight Tons 2 (approx.) Heating Power kw 300 Heating Mode o C 20-90 Temperature (in flow/ return flow) o C 90/70 WaterCoections - 2 /DN50 Regulation control o C 20-90 (105) High-Efficiency Pump Low-Temperature Boiler - 50/1-9 Oil Burner - 50-100% Oil Tank Container Litre 1 x 1,000 Safety Valve Bar 3 MAG Capacity Litre 200 Power Supply - 230V/50Hz/1phase Electrical Supply - CCE 16 A 23

Hot Water Package 600kW Dimensions mm (W)4,550x(D)2,450 x (H)2,450 Weight Tons 5 (approx.) Heating Power kw 600 Heating Mode o C 20-90 Temperature (in flow/ return flow) o C 90/70 WaterCoections - 4 /DN100 Regulation control o C 20-90 (105) Oil Burner - 50-100% Oil Tank Container Litre 1 x 4,000 Safety Valve Bar 3 MAG Capacity Litre 500 Power Supply - 400V/50Hz/3phase Electrical Supply - CEE 32A 24

Hot Water Package 1000kW Dimensions mm (W)2,450x(D)6,050 x (H)2,900 Weight Kg 6,450 Heating Power kw 1,000 Heating Mode o C 20-90 Temperature (in flow/ return flow) o C 90/70 WaterCoections - 4 /DN100 Fuel Consumption Litre/hr Max. 104 Oil Burner/ Gas burner (Turndown Ratio) - 2:1 / 6:1 Noise Level db(a) 71 Safety Valve Bar 6 Expansion Vessel Litre 800 Power Supply - 400V/50Hz/3phase Electrical Supply - CEE 63 A 25

Hot Water Package 2000kW Dimensions mm (W)2,450x(D)6,050 x (H)2,900 Weight Kg 7,150 Heating Power kw 2,000 Heating Mode o C 20-90 Temperature (in flow/ return flow) o C 90/70 WaterCoections - 4 /DN100 Fuel Consumption Litre/hr Max. 205 Oil Burner/ Gas burner (Turndown Ratio) - 2:1 / 6:1 Noise Level db(a) 71 Safety Valve Bar 6 Expansion Vessel Litre 1,500 Power Supply - 400V/50Hz/3phase Electrical Supply - CEE 63 A 26

Hot Water Package Air Handling Units Features ICS Cool Energy s hire division stock an extensive range of Air Handling systems that can be used to work alongside their hot water packages to distribute warm air throughout warehouse and industrial applications. The systems can be supplied in a range of duties from 5-150kW. All the units supply good static pressure and offer the highest levels of reliability. DutykW 7/12/30 Model Max Airflow m 3 /hr Ruing Current Noise level Length (mm) Width (mm) Height (mm) Weight (Kg) 5 Single Fan 3,240 2 (3ph) 62 1,025 820 1,010 126 25/1 10 DualDan 6,480 6 (3ph) 64 1,775 880 880 182 25/1 15 Upright 2,000 5 (1ph) 59 605 380 1,900 110 25/1 25 Upright 2,800 6 (1ph) 64 1,200 750 2,100 400 25/1 50 Upright 5,040 14 (1ph) 64 1,500 750 2,250 625 50/2 100 DualFan 27,700 6 (3ph) 66 3,050 1,253 1,376 669 50/2 150 Eco 20,000 11 (3ph) 76 2,610 1,270 2,000 695 50/2 Water Coections mm/ 27

Indirect Fired Heaters 70kW Features High pressure pump for diesel or paraffin Combustion chamber heat resistant up to 850 C 1-way pipe system prevents fuel disturbance 100% clean and dry heat Fixed outlet temperature circa 100-120 C High efficiency heat exchanger (91%) Capacity 70kW FuelConsumptionOil (l/hr) 7.0 Heated Air Flow (m3.hr) 3,800 Maximal Ventilator Back Pressure 200 Tank Capacity (l) 120 Power Coection 240V/1/50 16 Amp CEE forme 3 pin plug Outlet Cone Ø (mm) 400 Flue Coection Ø (mm) 180 Thermostat Coection YES 28

Indirect Fired Heaters 110kW Features High efficiency heat exchanger (92%) Combustion chamber heat resistant up to 850 C HP Radial fan for powerful heat distribution 100% Clean and dry heat Outlet temperature (delta T) circa 40-60 C Large heat throw Lower tray for oil containment during servicing Protection bars all around Dual voltage (110v/230v) Capacity 110kW FuelConsumptionOil (l/hr) 10.9 Heated Air Flow (m3.hr) 10,000 Maximal Ventilator Back Pressure 500 Power Coection dual voltage 1) 240V/1/50 2) 110V/1/50 Outlet Cone Ø (mm) 500 Flue Coection Ø (mm) 200 Thermostat Coection 16AmpCEEforme3 pin plug YES 29

Indirect Fired Heaters 200kW Features High efficiency heat exchanger (92%) Weather resistant and lockable casing High Pressure fan for powerful heat distribution Recirculation hose flange possible 100% Clean and dry heat Outlet temperature (delta T) of some 47 C Large heat throw Combustion chamber heat resistant up to 850 C Lower tray for oil containment during servicing Capacity Fuel Consumption Oil (l/ hr) 200kW 18.2 Heated Air Flow (m3.hr) 12,000 Maximal Ventilator Back Pressure Power Coection 415V/1/50 600 Outlet Cone Ø (mm) 2 x 500 Flue Coection Ø (mm) 200 Thermostat Coection 32AmpCEEforme5 pin plug YES 30

Fuel Cube 910 Litre Features 910 litre model can be transported full of diesel without the need for ADR driver training Easily stacked 2 high full, 3 high empty to reduce storage space requirements Access hatch for maintenance and inspection of ier tank Full load lifting eyes, forklift pockets and internal baffles designed to allow handling of the Fuel Cube full of fuel Secure lockable access hatch to house pumps (electric and hand) and feed and return coections for up to 3 rental units Ability to supply fuel for up to 3 rental units and refuel plant machinery all at the same time Sized to stack inside shipping containers and across truck beds providing economical transportation Protective galvanised framework preventing damage to tank, paintwork and decals Capacity (brim full) Litres 960 Capacity (brim full) Gallons 215 Dimensions Length (mm) 1150 Dimensions Width (mm) 1150 Dimensions Height (mm) 1320 Cabinet Dimensions (mm) Opening Size Design Apporvals Design Standards Brund Material (thickness) Ier Tank (thickness) Weight Unladen (Kg) 550 Weight Laden (Kg) 1423 To suit standard pump kit ADR IBC Type 31A Bunded to COP Regulations (PPG2) S235 (3mm) S235 (3mm) 31

Fuel Cube 2900 Litre Features Easily stacked 2 high full, 3 high empty to reduce storage space requirements Access hatch for maintenance and inspection of ier tank Full load lifting eyes, forklift pockets and internal baffles designed to allow handling of the Fuel Cube full of fuel Secure lockable access hatch to house pumps (electric and hand) and feed and return coections for up to 3 rental units Ability to supply fuel for up to 3 rental units and refuel plant machinery all at the same time Sized to stack inside shipping containers and across truck beds providing economical transportation Protective galvanised framework preventing damage to tank, paintwork and decals Capacity (brim full) Litres 2900 Capacity (brim full) Gallons 638 Dimensions Length (mm) 2300 Dimensions Width (mm) 1150 Dimensions Height (mm) 1320 Cabinet Dimensions (mm) Opening Size Design Apporvals Design Standards Brund Material (thickness) Ier Tank (thickness) Weight Unladen (Kg) 991 Weight Laden (Kg) 3691* To suit standard pump kit ADR IBC Type 31A DOT, UL Bunded to COP Regulations (PPG2) S235 (3mm) S235 (3mm) 32 * Specific gravity of diesel taken as 0.9 for this calculation

Notes 33

Notes 34

35

Equipment designed to ISO 9001 and all relevant directives. Product improvement is a continual process at ICS Cool Energy Ltd and we reserve the right to change the design and specifications without notice or obligation. Availability is subject to change without notice. Contact your local ICS Cool Energy depot for availability. ICS Cool Energy. All rights reserved. E&OE Depots Nationwide UK: 0800 774 7410 Email: info@icscoolenergy.com