The Occidental Chemical Center



Similar documents
Adaptive strategies for office spaces in the UK climate

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Selecting Energy Efficient New Windows in Georgia

Key energy-efficient features of your new home

CHAPTER 11: PASSIVE SOLAR HOMES

Elegance SC. Solar Control

Selecting Energy Efficient New Windows in Arizona

Selecting Energy Efficient New Windows in Texas

Preventing Ice Dams on Roofs

Selecting Energy Efficient Replacement Windows in Nevada

Selecting Energy Efficient New Windows in Florida

SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight

Current as of 11/10/08 1 of 1

DISCOVERY HALL, UNIVERSITY OF WASHINGTON BOTHELL Bothell, Washington 78,200 sf

KNX for building and room automation simple and efficient

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Building Code Clarifications - 7. Fire Resistance

This report presents the findings and recommendations of the assessment of energy use and

Table 1: Prescriptive Envelope Requirements: Residential WOOD FRAME WALL R-VALUE MASS WALL R-VALUE CEILING R-VALUE

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Miami Science Museum DoE Modelling Grant. Light Planning. 19 December 2008 Concept Design

Energy efficient home design

ENERGY SAVING WINDOW FILMS S LAR CONTROL

Energy savings in the residential area are essential in

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Total Building Commissioning: Case Study of the U.S. District Courthouse in Salt Lake City, Utah, USA

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

ResearcH JournaL 2009 / VOL

Integrated Solar Radiant Systems

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Deep Energy Savings in Existing Buildings

Retrofit EnerLogic Low-e Window Films

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

2014 British Columbia Building Code Changes

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

IECC Compliance Guide for Homes in Virginia

RESSÒ: energy efficiency urban rehabilitation

3-D Modeller Rendered Visualisations

CHAPTER 3. The sun and the seasons. Locating the position of the sun

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

2009 IECC Update. Scope. Content. International Energy Conservation Code

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

2.2 REFLECTIVE ROOFING (ADOPTED 19 DECEMBER 2006) 1. INTRODUCTION

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

WALLS Three common wall types are described below, with their insulation solutions.

GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES

1.2 Refrigerant Equipment. General

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

Heating and cooling. Insulation. Quick facts on insulation:

HEATING, VENTILATION & AIR CONDITIONING

Saint Cloud Business Center

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Passive Solar Design and Concepts

Energy Efficiency HOSPITALITY.

Glossary of Heating, Ventilation and Air Conditioning Terms

Energy Savings with Window Retrofits

Molds and mildew are fungi that grow

Energy Efficiency: Integrated Design and HVAC Systems HEALTHCARE - TOP 5 GREEN BUILDING STRATEGIES

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Mechanical, Plumbing, and Fire Protection Conditions

250 St Georges Tce, Perth, WA (QV1)

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable buildings

Construction Technologies Career Field Pathways and Course Structure

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

BUILDING PERMIT SPECIFICATIONS

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

Unbeatable energy efficient glass curtain wall system

john jay college of criminal justice

LEED PRESENTATION OUTLINE

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

High Performance School Buildings Resource and Strategy Guide

Solar Energy Utilisation in Buildings

Energy Savings in High-Rise Buildings Using High-Reflective Coatings

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

PROBIS SUPPORTING PUBLIC PROCUREMENT OF BUILDING INNOVATIVE SOLUTIONS

CHAPTER 4 VENTILATION

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Building Condition Assessment: North Howard Street Baltimore, Maryland

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

Improving thermal insulation of concrete sandwich panel buildings

Commerzbank Head Office. Frankfurt am Main

Single Family Residential Basement Finish

Energy Efficiency. Bars & RestauRants.

How a Ground Source Heat Pump Works for a School or College

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Transcription:

The Occidental Chemical Center Niagara Falls, New York, 1980, Cannon Design Inc. The Occidental Chemical Center (or Hooker Building) in Niagara Falls, New York was the first building in North America to be constructed with a Double-Skin Façade. Built on the heels of the 1970s Oil crisis, the client, Hooker Chemicals & Plastics Corporation, wanted both an energy conscious, yet distinguished flagship building that exploited the prominent location on the edge of the Niagara Gorge for its views, and also revitalized the faltering downtown core by its siting on axis with the Rainbow Bridge between Canada and the United States. The Hooker Building is touted as being one of the most energy efficient commercial buildings in the world and is the recipient of numerous citations for design excellence from the AIA and Illuminating Engineering Society as well as the Energy Conservation Award from the Owens Corning Fiberglas Corporation and the EPA Energy Star (EPA, 2001). Completed in 1980, it becomes one of the oldest examples of the modern Double-Skin building, and provides twenty-one years of valuable performance information on this controversial building technology. The Hooker Building West facade from Niagara Gorge parking lot and detail of the Southeast corner with pedestrian bridge that formerly connected to the parkade. Design Intentions: In order to best exploit the views of the Gorge offered by the North, West and South sides of the building, Cannon Design Inc. elected for floor to ceiling glazing on this otherwise conventional nine-storey cube with central service core surrounded by office and retail space. In order to

THE TECTONICS OF THE ENVIRONMENTAL SKIN meet the other design criteria of the client, the architects decided to explore the use of a Buffer Façade with an undivided air space continuous over the entire building with motorized dampers for air intake at grade and vents at the top. The building is comprised of two different airhandling systems: one for the façade and the second for the conditioning of the interior spaces. Due to the energy conscious mindset at the time, this system was selected because it does not allow for the occupants to have direct access or control over natural ventilation (hence less variable incoming cold air to heat, the less energy spent heating it), but instead it is controlled as part of the air intake of the ambient HVAC system. This design also allows the warm air within the wall cavity to temper the outside air on the exterior skin and act as a buffer for the interior layer of glass. The building envelope is comprised of two layers of green-tinted insulating glass that allow for 80% solar penetration as the exterior skin, a 1200mm air space containing hollow metal, air-foil shaped, white louvers - spanning fifteen feet and vertically spaced eight inches a part - with service grilles (originally covered with beige carpeting to give the appearance that the floor continued from within the offices through to the exterior glass), and one layer of clear glass as the interior skin. As a means of being economical, the architects made sure that all the components of the façade - Above: the current North Facade. Below: floor plans showing the original entrance cut into the East facade; the only place in the building where the otherwise uniform facade is interrupted.

save the control and monitoring equipment - were off the shelf. The louvers in the air cavity are controlled by an intelligent light sensor system that responds according to weather, time of day and season. The sensors are placed in pairs to discount mullion shadows and a delay response cancels the effect of passing clouds. The façade is separated into four different zones according to the North, South, East and West exposures so that each of the four walls may respond according to the amount of daylight being admitted according to the particular time of day. The louvers are capable of fully closing as means of providing additional insulation during the winter months. Initial Problems: The occupational needs of the building changed as construction neared completion. Instead of the anticipated cooling load for day time office workers, the building was now to be occupied by research facilities with hours that extended into the evening as well. According to the architects, the original design of the wall system cut the mechanical systems requirements in half, thereby offsetting the cost of the second skin. However, with the changes in occupational require- The Hooker Building Southern facade is pictured here along with the thermal zoning design schematic showing both areas with daylighting and the differing HVAC zones, along with both vertical and horizontal sections through the buffer facade.

ments, the cooling loads increased significantly and the gas-fired boilers that were installed were never required to heat the building, not even during extreme winter weather. Originally the louvers were to be painted with a highly reflective coating to minimize solar heat gain and allow for sunlight to be refracted deeper into the space. However, the glare created from the coating was blinding motorists as they crossed the bridge, so the louvers had to be repainted with a matte white finish. Current Problems: The Hooker Building is currently undergoing a major renovation. Bought by AquaFalls Inc., the plaza at the original East Entrance of the building is being developed into a 40,000 square foot aquarium that will incorporate tunnels with shops and restaurants beneath the surface and turn the original building into the North American headquarters for the company. Despite the US$35 million promised investment, due to delays the building is currently occupied on only three out of nine floors. Complications have also arisen due to the excavation in front of the building: the intake grilles at grade have been covered with plywood because of the amount of dust, dirt and particulates that were accumulating in the wall cavity, and therefore air is unable to be drawn through the façade causing chronic problems with over-heating in upper floors. Because of the low occupancy, the design cooling load is not being met and consequently lower floors are recurrently too cold. The original East entrance now overlooks the excavation for the aquarium, as a corner detail reveals a glimpse into the currently inactive wall cavity. According to the security personnel the louvers ceased to function four years ago, and haven t been serviced since. Because of this they are stuck in a horizontal position and only negate 50% of the incoming solar radiation on the South side of the building and even less on the East and West façades. Tenants have since taken the initiative and installed vertical blinds on the inside of the office space in an attempt to have some solar control. Because of the current disrepair and neglect of the building in its interim state, the current tenants of the building constantly complain of being either too hot or too cold. There

has also been significant clouding formed on the inside of the exterior glass, resulting in a blemished façade. Considerations: The Buffer Façade was adopted in order to achieve specific environmental goals: to reduce the cooling load in the summer and lessen heating loads in the winter. However, in their preoccupation with conservation of energy, the designers seemed to overlook the problems that would result from a system wide failure of the façade. Despite the numerous citations and awards the building has received, the controls failed, the building is rendered extremely uncomfortable and energy inefficient. Ironically, after twentyone years, the only parts of the building façade that are still functioning are those that were off-the-shelf and not the custom monitoring and controlling equipment. The gravity of the problems currently faced by the Hooker Building is directly related to the inadaptability of the façade. If comparing the Buffer Façade to a Twin-Face Façade, the natural ventilation and operable windows integrated into the Twin-Face Façade make the envelope still useful - and solely problematic - in case of complete failure. Because fresh air is still able to circulate through the façade and into the interior spaces, better working conditions and comfort levels are maintained, as opposed to the static, airless position of a failed Buffer system. Photos of the interior of the wall cavity and clouding of the exterior skin. Detail photo of skin clouding taken by Terri Meyer-Boake. The Achilles heel of the Buffer Façade seems to be the exact thing that makes it function: the mechanical dependence for control of ventilation, dampers, fans, windows, and louvers. In a standard curtain wall system, these are never concerns. Is it fair to judge the Buffer Façade in comparison with a high performance curtain wall system that doesn t depend on intelligent systems? When the concern of the architect is with using off-the-shelf components (like a curtain wall system) the answer seems to be yes. Still the question remains: would the façade have lasted longer had it been properly maintained and repaired, or would these same problems have occurred if the building had not changed owners multiple times and been neglected?

Looking to the Future: The problems incurred by the Hooker Building raise valid concerns regarding the longevity and life-cycle costing of this type of building façade. It remains to be seen how the renovation will affect the building and how, with replacement and repair, the system will perform in another twenty years. Quick Building Overview Building: The Hooker Office Building/Occidental Chemical Center Client: Hooker Chemicals & Plastics Corporation Year: 1980 Architect: Cannon Design Inc., Principal, Mark R. Mendell Consultants: Hellmuth, Obata & Kassabaum Programme: 16000m2 Corporate office space with 4000m2 leaseable commercial space Site: Niagara Falls, New York, Northwest corner diagonally on axis with Rainbow Bridge, overlooking the Niagara Gorge on North, West and South sides Climate: Cold Facade Construction: Buffer Facade with undivided, full height air space Cavity Dimension: 1200mm Daylighting: Maximizes exposure with floor to ceiling glazing Shading: Operable louvers in air space with photocell control and manual override Adaptability: Facade divided into four zones one for each orientation and are independent of each other as they respond to time of day and sun angle User Control: Only indirect control through the use of vertical blinds Ventilation: Two systems: one for the extraction of air from within the wall cavity the second for conditioning of the interior spaces Aesthetics: Square plan office tower covered in ubiquitous green glass skin Structural System: Steel Frame, metal decking Mechanical System: Cooling - Electrically driven centrifugal chillers (for year-round heat recovery) Heating - gas-fired boilers Ventilation - low pressure variable air volume distribution All building systems (louvers, HVAC, fire alarm, security) all controlled by centralized automated mainframe computer Design Energy Budget: 114,000 BTU per square foot per year Cost: US$12,500,000 (Bid January 1980) Approximately US$62 per square foot All text and drawings by Kate Harrison with contribuitions made by Terri Meyer-Boake. All photos taken by Kate Harrison unless otherwise noted. Please note the bibliography is incomplete and will be made available as soon as possible. Cannon Design Inc: http://www.cannondesign.com/portfolio/corporateandcommercial/occidentalchemicalcorporation.cfm EPA Energy Star Labeled Building Profiles http://estar4.energystar.gov/estar/cpdcasestudy.nsf/oprofiles/occidentalchemical.html