SOLI TANKLESS PRODUCT GUIDE

Similar documents
TANKLESS DURABILITY Tankless Product Guide

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Navien Condensing 98% Tankless Water Heaters. Tankless Water Heaters. Navien Condensing. The Ultimate in Energy Efficiency with Hi-Tech Comfort

Commercial Gas Water Heaters

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

NAVIEN AMERICA INC FITCH AVENUE

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Commercial Gas Water Heaters

THERM Tankless Water Heaters. Applications Manual

Commercial Gas Water Heaters

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Commercial Gas Water Heater

RECON WATER HEATER INSTALLATION FORM

ASME Packaged Indirect Fired Water Heater

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

HEAVY DUTY STORAGE GAS

Eternal Hybrid: Engineered For How You Live. Award Winning Technology. Now Available in Canada.

SPIDERfire: Delivers high efficiency and real savings for today s businesses

CONDENSING TANKLESS WATER HEATERS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Better Boilers.

SOLID. STATE. StateWaterHeaters.com

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

CHAPTER 9: WATER HEATING

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Commercial Boiler Systems and Controls

SIOUX HYBRID WATER HEATER

Domestic Hot Water Systems and Plumbing Products

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Condensing Boiler Efficiency

Cooling Capacity CFM in. w.c. (125 Pa)

Light Duty Commercial Electric Water Heater

Endless Hot Water 24/7

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

High efficiency, cast-iron gas boiler

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

Commercial Semi-Instantaneous Water Heaters

On-Demand Water Heater Installation Manual and Owner s Guide

Applications manual. For tankless and point-of-use water heaters

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,

PLBG/GAS SAFETY Information Bulletin

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

Electric & Gas Water Heaters

Steam System Best Practices Condensate System Piping

Air Conditioner Water Heater Model ACWH18

Tankless water heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

2010 Residential Water Heater Replacement Check List

G234X-55 Conventional Gas Boiler

Electric Flow Boiler

Installation & Operation Manual Models: STU

SWIMMING POOL HEAT PUMP

On-Demand Water Heater Installation Manual and Owner s Guide

Originators of the Flexible Water Tube design

REGULATORS 175/153 Series

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

FYI > California Title 24

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

LG Electronics AE Company, Commercial Air Conditioning

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Dehumidification Frequently Asked Questions

T-KJr. Instantaneous Water Heater Installation Manual and Owner s Guide

Preventing Overheated Boiler Incidents

T-K3 Instantaneous Water Heater Installation Manual and Owner s Guide

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Electric Water Heater

Hot Water Heating: Technologies and Use

Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Cooling Capacity CFM in. w.c. (125 Pa)

DESIGNER S GUIDE EFFICIENCY+ BOILER

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

APC APPLICATION NOTE #112

USER S MANUAL HSC-24A

Indirect Fired Water Heaters

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Installation & Operation Manual Models: SIT030 - SIT119

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

HL Series - Commercial Heaters Tankless Water Heating Solutions

Installation Operation Maintenance

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Arapahoe County Residential Water Heater Installation and Inspection Guide

OTF Oil Fired Pool Heater

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Bosch Commercial Water Heating Solutions. Includes the newest Bosch tankless, point-of-use and heat pump water heater products.

Vitodens 200, B2HA / B2HB - Product Introduction

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Transcription:

SOLI TANKLESS PRODUCT GUIDE

SAVE ENERGY. Energy-efficient, plentiful, and endless supply of hot water. SAVE SPACE. Compact size and wall-mounted to free up valuable floor space. SAVE MONEY. The smart choice that will save you a substantial amount of energy. A. O. Smith has delivered innovative hot water solutions for more than 7 years and is sold exclusively by plumbing wholesalers and contractors. A. O. Smith s selection of residential and commercial tank-type, tankless, hybrid water heaters, boilers and storage tanks is unmatched for quality and diversity. Anywhere hot water is needed, A. O. Smith provides an energy-efficient solution with long-lasting value for years after installation. A. O. Smith stands behind its products and customers with world-class service, combining cutting-edge technology with committed people who take pride in being the very best. A. O. Smith is headquartered in Ashland City, Tennessee, home of the world s largest water heater factory. The A. O. Smith network includes five manufacturing facilities in North America, plus plants in Nanjing, China and Veldhoven, Netherlands.

TANKLESS ADVANTAGE HOW IT WORKS The Process: A hot water tap is opened. The opened tap allows water to flow through the water heater. An internal water flow sensor detects this flow. Upon flow detection, the flow sensor sends the activation signal to the computer board. The computer automatically ignites the burner. As water flows through the heat exchanger, it absorbs heat from the burner. By the time the water exits the heater, it has reached the designated set temperature. When the hot water tap is closed, the water heater automatically turns off. ENDLESS HOT WATER * Heating water only as it s being used means you will never run out of hot water again. After the few seconds it takes for the water to reach the designated set temperature, our water heaters will continually provide a steady flow of hot water for as long as your application needs it. *A. O. Smith tankless water heaters provide endless hot water when sized appropriately for your home s needs. ENERGY CONSERVATION Provides you with continuous hot water in one of the most energy-efficient ways possible. Conventional tank-type water heaters will heat and store a set volume of water, regardless of whether someone is using that hot water or not. Because our water heaters only activate when hot water is being used, no standby energy losses are incurred, providing efficient heating while conserving energy. COMPACT SIZE On top of all this, an A. O. Smith tankless water heater takes up much less space than your conventional tank-type water heater or boiler. With no tank or boiler to steal valuable storage space, A. O. Smith s wall-mount design allows for additional storage and flexibility. 1

SAFETY At A. O. Smith, we place the safety and reliability of our products above all else. By incorporating technologically advanced safety features into every model, we provide the assurance and peace of mind that can only come from an A. O. Smith quality product. Air-Fuel Ratio (AFR) Sensor A. O. Smith s unique AFR sensor monitors and maintains proper combustion at all times. Together with the onboard computer, this system will adjust the fan motor speed to ensure that air and fuel have a proper mixture ratio, minimizing emissions and maximizing efficiency. Additional Safety Features Freeze Protection: Every heater in A. O. Smith s tankless lineup has an internal freeze protection system, which is rated to protect the heaters when installed in sub-freezing conditions. This system works to keep water temperatures within the heat exchanger from falling below a certain level, preventing freeze damage. Hi-Limit Switch: Ensures that water temperatures do not exceed safe levels. Before the water temperature can even reach these unsafe levels, the hi-limit switch activates by disengaging the gas valves, effectively shutting down the water heater. Overheat Cutoff Fuse: Ensures that there are no breaches in the heat exchanger drum. In cases where enough physical damage might have been done to the water heater to lead to a breach in the heat exchanger drum, the overheat cutoff fuse reacts by shutting down the water heater if the surface of the heat exchanger retains too much heat. 2

DURABILITY HEAT EXCHANGER WITH COMMERCIAL-GRADE COPPER Only A. O. Smith incorporates true commercial-grade heat exchangers in our tankless heaters. NOTE: 51 Series, 51U Series, 54H Series and 91 Series non-asme models. All aspects of the heat exchanger are designed to add the durability and reliability that is vital to any successful commercial organization or business. Commercial-Grade Copper Alloy Our commercial-grade copper is a heat-resistant copper alloy, with additive elements that make it much stronger and harder than the standard C122 copper used in most other heat exchangers. Our commercial-grade copper has 8 times the tensile strength of regular copper. Even at high temperatures, our commercial-grade copper maintains a fine grain and high Commercial-Grade Copper Tubing strength. Commercial-grade copper provides resistance to the damaging effects of erosion that can cause heat exchangers to leak..16" (.4mm) A thinner drum strains more under heat stress.2" (.5mm) drum.16" (.4mm) water drum coil water drum coil.2" (.5mm) Drum Thickness water During every ignition cycle, thermal expansion causes all heat exchangers to undergo heat stress. After the thousands of ON/OFF cycles typically seen in a commercial application, this heat stress can prove damaging. This is why the heat exchangers in our commercial and light commercial products utilize drums that are 25% thicker, water ensuring the longevity of our products. A thicker drum creates less strain on the heat exchanger. 25% Thicker drum drum coil drum coil A thicker drum creates less strain on the heat exchanger A thicker drum creates less strain on the heat exchanger. water water drum coil drum coil water drum coil 25% Thicker drum water drum coil r drum creates less strain on the heat exchanger. 3

WATER VALVES Making true commercial-grade water heaters involves more than just redesigning our heat exchangers every internal component has to measure up to A. O. Smith s commercial standards. Just like our advanced heat exchangers, the longevity and functionality of components such as our water valves and flow sensors are also of great importance. Our commercial water heaters (51/U, 54H & 91 series) feature a bypass and flow adjustment valve, which not only provide the optimal control and precision essential for commercial usage, but also offer the durability needed to handle tough, high-volume conditions. Stepper Motor Water Valves Bypass Valve - 51/U and 54H Models Flow Adjustment - 51/U and 54H Models 4

SECONDARY HEAT EXCHANGER 316L STAINLESS STEEL (CONDENSING MODELS ONLY) The secondary condensing heat exchanger is made of high-quality 316L stainless steel. This is where the rest of the heat transfer occurs. Due to the lower temperature acidic condensation occurs, and stainless steel is required in order to avoid corrosion. For condensing heat exchangers, it is more suitable to use 316L stainless steel because of the extreme environment (heat, acidic condensation, chloride) that the material is subjected to. Secondary HX-Stainless Steel 316L PRIMARY HEAT EXCHANGER: COPPER VS. STAINLESS STEEL Bypass Valve Hot Water Outlet Flow Sensor Drum Coil Cold Water Inlet Flow Adjustment Valve Primary HX Commerical-Grade Copper Heat transfers 25 times more readily through copper than stainless steel. Consequently, for the same amount of heat transfer, stainless steel heat exchangers need to be larger than copper heat exchangers, leading to a larger pressure loss. At higher temperatures, it is the nature of stainless steel to become prone to a number of problems not usually experienced at room temperature. It is vulnerable to pitting corrosion and stress corrosion cracking (SCC). Stainless steel is NOT better for durability because it is harder. Hardness causes the material to become brittle. Stainless steel will crack after numerous cycles of thermal expansion/contraction, especially with chloride in the water. Copper heat exchangers are less brittle and better suited for expansion/ contraction without cracking. In a dual heat exchanger design, corrosion is not a big concern in the non-condensing primary heat exchanger because no condensation forms on the exterior of the pipes. Stainless steel is unnecessary for this stage. Note: 14, 24 and 34 condensing line units use C122 copper and do not have a bypass valve * Diagram represents 54H 5

WATER FLOW Condensation can build up over time in any heat exchanger, causing damage and premature leaks. A. O. Smith s commercial models (91 series) include condensation reduction features that safeguard against these types of damaging effects. Finned Coil (9%-95% of total heat absorbed) Better Water Pathway Design By redesigning and redirecting the flow of water, the temperature of the heat exchanger drum and finned coils stay elevated above dew point, making it much more difficult for condensation to build. Fin Pitch By widening the pitch of the heat exchanger fins, not only do we improve durability by reducing occurrences of blockage, we also maintain higher temperatures on the upper finned coils. Keeping these coils at elevated temperatures reduces the likelihood of condensation buildup. Drum Coil (5%-1% of total heat absorbed) Hot Water Outlet (1% heat absorbed) No condensation buildup on drum coil Burner M Bypass Valve (51/U, 54H & 91) Flow Sensor Cold Water Inlet FIN 6

BASIC SIZING GUIDELINES The flow rate capacity of tankless water heaters depends on the temperature difference between the desired output and incoming water temperature. The flow rate comparison chart and table shown here summarize the flow rate charts found in the specifications of each model. A. O. Smith water heaters are sized according to the peak flow rate requirements, worst-case temperature-rise scenarios, and types of applications. Once these factors have been determined, refer to either the flow rate comparison here or the flow rate charts found in each model s specifications. Select the appropriate water heater as well as the amount of water heaters required. Application designers/engineers can decide whether to size for full flow, expected flow, or utilize probability models such as the modified Hunter Curve. For large scale applications such as hotels, apartment complexes and large restaurants, Hunter Curves are commonly used to estimate the peak flow rate demand when given the total amount of fixture units within an application. It is up to the application designer/engineer to determine the amount of fixture units within any given application. MATCH THE UNIT TO YOUR NEEDS Warmer Climates 7 F Incoming Groundwater Temperature Cooler Climates 5 F Incoming Groundwater Temperature Capacity - Number of Shower Heads (Assuming the set point temperature is 12 F ) Non-Condensing Units ATI/O-11/U 2.5 Showers 1.5 Showers ATI/O-31/U 3.5 Showers 2.5 Showers ATI/O-51/U 3.5 Showers 2.5 Showers Condensing Units ATI/O-14H 2.5 Showers 1.5 Showers ATI/O-24H 3.5 Showers 2.5 Showers ATI/O-34H 4 Showers 2.5 Showers ATI/O-54H 4.5 Showers 3 Showers Commercial Unit ATI/O-91 7 Showers 5 Showers 7

FLOW RATE GUIDE Temperature Rise vs. Gallons per Minute Temp Rise 11/U Series 31/U Series 51/U Series 14H Series 24H Series 34H Series 54H Series 91 Series 3 6.6 8. 1. 6.6 6.6 8. 1. 14.5 35 6.6 8. 9.3 6.4 6.6 8. 1. 14.5 4 5.7 7.8 8.1 5.6 6.6 8. 9.5 14.5 45 5.1 6.9 7.2 5. 6.6 7.6 8.4 13.5 5 4.6 6.2 6.5 4.5 6.1 6.8 7.6 12.2 55 4.2 5.7 5.9 4.1 5.5 6.2 6.9 11.1 6 3.8 5.2 5.4 3.7 5.1 5.7 6.3 1.1 65 3.5 4.8 5. 3.4 4.7 5.3 5.8 9.4 7 3.3 4.4 4.7 3.2 4.3 4.9 5.4 8.7 75 3.1 4.1 4.3 3. 4.1 4.6 5. 8.1 8 2.9 3.9 4.1 2.8 3.8 4.3 4.7 7.6 85 2.7 3.7 3.8 2.6 3.6 4. 4.4 7.2 9 2.5 3.5 3.6 2.5 3.4 3.8 4.2 6.8 95 2.4 3.3 3.4 2.3 3.2 3.6 4. 6.4 1 2.3 3.1 3.3 2.2 3. 3.4 3.8 6.1 Flow rate is determined by temperature rise. To determine your temperature rise, subtract the incoming water temperature from the set output temperature. All units are factory set to 12 F or 122 F but can be changed. Example of Hunter Curves for Sizing Large Applications Comparison of Flow Rates vs. Temperature Rise Hunter Curves for Sizing Large Applications 1 16 9 8 7 6 Flow Rate (gpm) 14 12 1 Gallons Per Minute 5 4 3 2 1 8 6 4 2 25 5 75 1 125 15 175 2 225 25 275 3 325 Fixture Units 35 375 4 2 4 6 8 1 Temperature Rise ( F) 12 14 Restaurants Hospitals, Nursing Homes, Dormitories, Hotels & Motels Apartments & Houses Office Buildings & Schools 91 SERIES 51/U SERIES 54H SERIES 34H SERIES 24H SERIES 31/U SERIES 14H SERIES 11/U SERIES 8

11 SERIES NON-CONDENSING The 11 Series is great for apartments, one bath homes in cold climates, condos and summer cabins. Remote control included as a standard feature. ATI-11-NI ATO-11-NE Dimensions 4" (11 mm) 13-3/4" (35mm) 4" (11 mm) 1" (254mm) 13-3/4" (35mm) 1-3/4" (45mm) 1" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 1-3/4" (45mm) 4" (12mm) 4" (12mm) 21-3/8" (544mm) 2-1/4" (52mm) 21-3/8" (544mm) 2-1/4" (52mm) 2-1/4" (56mm) 2-1/4" (56mm) 2-1/4" (57mm) 2-1/4" (57mm) 1-7/8" (47mm) 1-7/8" (47mm) COLD 3-1/8" (79mm) HOT 5-1/4" (133mm) COLD 3-1/8" (79mm) HOT 5-1/4" (133mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 1" (26mm) 2-1/4" (56 mm) 1" COLD (26mm) 3-7/8" (98mm) 2-1/4" GAS (56 mm) COLD 4-7/8" (123mm) 3-7/8" 12V(98mm) GAS 4-7/8" (124mm) 4-7/8" HOT (123mm) 12V 7-3/4" (196mm) 4-7/8" (124mm) HOT 7-3/4" (196mm) 9

Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Low NOx emissions **Refer to www.hotwater.com for further warranty details. ATI-11-NI includes both a remote control and power cord as standard features. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 7-3/4" (D), Weight: 33 lbs Electric 12 V 73 W /.73 A (Operation) 6 W /.5 A (Standby) 111 W /.93 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 53 db at Max output Fuel NG LP Min. Input 19,5 BTU/h 19,5 BTU/h Gas Consumption Max. Input 14, BTU/h 14, BTU/h Energy Factor.82.82 Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 11 Temperature Settings 3/4" NPT.2 Gallons Pressure Only Relief Valve Requires (Min 14, btu/h, 15 PSI). 15-15 PSI 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multi-Unit System N/A N/A Dipswitches 113 F 122 F (default) 131 F 14 F With 976665 remote (max. distance 15 from heater, non-polarized 2 gauge wiring.) 99 F to 167 F (16 options), 122 F Default Factory Setting 11U: Pressure Loss 11: Flow Rate vs. Temperature Rise 11: Pressure Loss 11: Flow Rate vs. Temperature Rise 9. 5 12 8. 7. 6. 5. 4. 3. 2. 1.. 2 4 6 8 1 12 14 Pressure Loss (psi) 45 4 35 3 25 2 15 1 5. 2. 4 6. Flow Rate (gpm) 11 1 9 8 7 6 5 4 3 2 1 8. Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Outdoor Installations Front 4 (Recommended 24 for maintenance) 1

31 SERIES The 31 features a max flow rate of 8. gpm, providing enough hot water to run three showers at the same time. Remote control included as a standard feature. ATI-31-NI ATO-31-NE Dimensions 13-3/4" (35mm) 13-3/4" (35mm) 4" (11 mm) 1" (254mm) 1" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 4" (11 mm) 1-3/4" (45mm) 1-3/4" (45mm) 4-3/8" (113mm) 4-3/8" (113mm) 21-3/8" (544mm) 2-1/4" (52mm) 21-3/8" (544mm) 2-1/4" (52mm) 1-3/8" (36mm) 1-3/8" (36mm) 19-3/8" (493mm) 19-3/8" (493mm) 1-5/8" (43mm) 1-5/8" (43mm) 1-7/8" (47mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 12VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 12VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 11

Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Low NOx emissions **Refer to www.hotwater.com for further warranty details. ATI-31-NI includes both a remote control and power cord as standard features. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 9-1/2" (D), Weight: 38 lbs Electric 12 V 88 W /.73 A (Operation) 6 W /.5 A (Standby) 111 W /.93 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 53 db at Max output Fuel NG LP Min. Input 11, BTU/h 11, BTU/h Gas Consumption Max. Input 19, BTU/h 19, BTU/h Energy Factor.82.82 Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 31 Temperature Settings 8. GPM 3/4" NPT Values based on factory testing..4 GPM required for continuous fire after initial ignition.2 Gallons Pressure Only Relief Valve Requires (Min 19, btu/h, 15 PSI). 15-15 PSI 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multi-Unit System N/A N/A Dipswitches 113 F 122 F (default) 131 F 14 F With 976665 remote (max. distance 15 from heater, non-polarized 2 gauge wiring.) 99 F to 167 F (16 options), 122 F Default Factory Setting 31: Flow 31: Rate Flow vs. Rate Temperature vs. Temperature Rise Rise 31: Pressure 31: Pressure Loss Loss 9. 8. 7. 6. 5. 4. 3. 2. 1.. 2 4 6 8 1 12 14 Pressure Loss (psi) 5 45 4 35 3 25 2 15 1 5. 2. 4 6. 8. 1. 12 11 1 9 8 7 6 5 4 3 2 1 Head (ft) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Outdoor Installations Front 4 (Recommended 24 for maintenance) 12

51 SERIES The 51 series is well suited for residential/commercial applications such as small restaurants and beauty salons. Utilizing commercialgrade copper alloy for the heat exchanger tubing, the 51 series is also suitable for heavier residential usages such as combination space heating and domestic recirculation systems. Remote control included as a standard feature. ATI-51-NI ATO-51-NE Dimensions 13-3/4" (35mm) 13-3/4" 4" (35mm) (11 mm) 1" (254mm) 1" (254mm) 1-3/4" (45mm) 1-3/4" (45mm) 4" (11 mm) 1-3/4" (45mm) 1-3/4" (45mm) 4-3/8" (113mm) 4-3/8" (113mm) 21-3/8" (544mm) 2-1/4" (52mm) 21-3/8" (544mm) 2-1/4" (52mm) 1-3/8" (36mm) 1-3/8" (36mm) 19-3/8" (493mm) 19-3/8" (493mm) 1-5/8" (43mm) 1-5/8" (43mm) 1-7/8" (47mm) 1-7/8" (47mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) COLD 3-1/4" (84mm) HOT 5-1/4" (133mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 12V 1-3/8" (36mm) GAS 4-7/8" (124mm) 1" (26mm) COLD 2-7/8" (71mm) 1" (26mm) 12VAC 3-7/8" (99mm) COLD 2-7/8" (71mm) GAS 5-1/4" (135mm) 12VAC 3-7/8" (99mm) HOT 6-1/2" (164mm) GAS 5-1/4" (135mm) 9-1/2" (241mm) HOT 6-1/2" (164mm) 9-1/2" (241mm) 13

Specifications Thicker heat exchanger drum and utilizes commercial-grade copper (heatresistant) copper for the heat exchanger tubing. Provides a variety of installation options: indoor, outdoor, and direct vent. Includes a pump control port, ensuring efficient operation of all circulation pumps. Easy-Link System capable up to 4 units. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. ATI-51-NI includes both a remote control and power cord as standard features. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4 (H) X 13-3/4 (W) X 9-1/2 (D), Weight: 39 lbs Electric 12 V 9 W /.75 A 6 W /.5 A 111 W /.93 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 55 db at Max output Fuel NG LP Min. Input 11, BTU/h 11, BTU/h Gas Consumption Max. Input 199, BTU/h 199, BTU/h Energy Factor.82.82 Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 51 Temperature Settings 1. GPM 3/4" NPT Values based on factory testing..4 GPM required for continuous fire after initial ignition.2 Gallons Pressure Only Relief Valve Requires (Min 2, btu/h, 15 PSI). 15-15 PSI 4 psi or above recommended for max. flow Easy-Link System Up to 4 units With no need for a system controller Multi-Unit System N/A N/A Dipswitches 14 F 113 F 122 F (default) 14 F With 97635 remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 176 F (15 options), 122 F Default Factory Setting T-D2: Flow Rate vs. Temperature Rise 51: Flow Rate vs. Temperature Rise 51: Pressure Loss 51: Pressure Loss Flow Rate (gpm) 12 1 8 6 4 2 2 4 6 Set temperature: 122 F or lower Set temperature: 131 F or higher 8 1 12 Temperature Rise ( F) 14 Pressure Loss (psi) 5 45 4 35 3 25 2 15 1 5. 2. 4 Set temperature: 122 F or lower Set temperature: 131 F or higher 6. 8. 1. Flow Rate (gpm) 12 11 1 9 8 7 6 5 4 3 2 1 Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Outdoor Installations Front 4 (Recommended 24 for maintenance) 14

11U Series The 11U Series is great for apartments, one bath homes in cold climates, condos and summer cabins. Remote control included as a standard feature. Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. ATI-11U-NI ATO-11U-NE ULTRA-LOW NOx 2. Exterior view 11U Indoor (T-KJr2U-IN) 31U Indoor (T-K4U-IN) 51U Indoor (T-D2U-IN) Dimensions Front view Side view 3-5/8" (94 mm) 13-3/4" (35 mm) 1" (254 mm) 7" (18 mm) 4" (11 mm) 4-3/8" (113 mm) 2-1/4" (52mm) 1-3/8" (36 mm) 1" (26 mm) 12 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) HOT 4-5/8" (119 mm) COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm) 13-1/8" (334 mm) 5-1/8" (13 mm) ) ) ) 2-1/4" (58 mm) 19-3/8" (493 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) 12 VAC 1-5/8" (4 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) Top view Bo om view 15 HOT 5" (127 mm) 4-3/8" (113 mm)

Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with Ultra-Low NOx regulations. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. Indoor models include both a remote control and power cord as standard features. Outdoor models include remote control as a standard feature. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 9-1/2" (D), Weight: 37 lbs Electric 12 V 52 W /.54 A (Operation) 5.4 W /.8 A (Standby) 131 W / 1.1 A (Freeze-Protection) Ignition Noise Level Electronic Ignition IN: 54 db OS: 58 db at Max output Fuel NG Gas Consumption Min. Input 15, BTU/h Max. Input 14, BTU/h Energy Factor.82 Gas Pressure Min 5." W.C. Max 1.5" W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.2 Gallons Water Pressure 15-15 PSI Pressure Only Relief Valve Requires (Min 14, btu/h, 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Easy-Link System N/A N/A Installation Multi-Unit System N/A N/A 11U Temperature Settings Dipswitches 12 F (default) 14 F With 99695 remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F (9 options), 12 F Default Factory Setting 11U: Flow Rate vs. Temperature Rise 11U: 11U: Pressure Pressure Loss Loss 11: Flow Rate vs. Temperature Rise 9. 5 12 8. 7. 6. 5. 4. 3. 2. 1.. 2 4 6 8 1 12 14 Pressure Loss (psi) 45 4 35 3 25 2 15 1 5. 2. 4 6. Flow Rate (gpm) 11 1 9 8 7 6 5 4 3 2 1 8. Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Side 3 Outdoor Installations Side 3 Front 4 (Recommended 24 for maintenance) Side 3 Side 3 16

31U Series The 31U features a max flow rate of 8. gpm providing enough hot water to run three showers at the same time. Remote control included as a standard feature. Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. ATI-31U-NI ATO-31U-NE 2. Exterior view 11U Indoor (T-KJr2U-IN) 31U Indoor (T-K4U-IN) 51U Indoor (T-D2U-IN) Dimensions Front view Side view 3-5/8" (94 mm) 13-3/4" (35 mm) 1" (254 mm) 7" (18 mm) 4" (11 mm) 4-3/8" (113 mm) 2-1/4" (52mm) 1-3/8" (36 mm) 2-1/4" (58 mm) 19-3/8" (493 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) 12 VAC 1-5/8" (4 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) 1" (26 mm) 12 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) HOT 4-5/8" (119 mm) Top view COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm) Bo om view 13-1/8" (334 mm) 5-1/8" (13 mm) 17 OT 5" (127 mm) 3/8" (113 mm)

Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with Ultra-Low NOx regulations. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. Indoor models include both a remote control and power cord as standard features. Outdoor models include remote control as a standard feature. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4 (H) X 13-3/4 (W) X 9-1/2 (D), Weight: 37 lbs Electric 12 V 76 W /.8 A (Operation) 6 W /.8 A (Standby) 131 W / 1.1 A (Freeze-Protection) Ignition Noise Level Electronic Ignition IN: 54 db OS: 58 db at Max output Fuel NG Gas Consumption Min. Input 15, BTU/h Max. Input 19, BTU/h Energy Factor.82 Gas Pressure Min 5." W.C. Max 1.5" W.C. Flow Rate 8. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.2 Gallons Water Pressure 15-15 PSI Pressure Only Relief Valve Requires (Min 19, btu/h, 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Easy-Link System N/A N/A Installation Multi-Unit System N/A N/A 31U Temperature Settings Dipswitches 12 F (default) 14 F With 99695 remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 12 F to 14 F (9 options), 12 F Default Factory Setting 31U: 31: Flow Flow Rate Rate vs. vs. Temperature Rise Rise 31U: 31: Pressure Pressure Loss Loss 9. 8. 7. 6. 5. 4. 3. 2. 1.. 2 4 6 8 1 12 14 Pressure Loss (psi) 5 45 4 35 3 25 2 15 1 5. 2. 4 6. 8. 1. 12 11 1 9 8 7 6 5 4 3 2 1 Head (ft) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Side 3 Outdoor Installations Side 3 Front 4 (Recommended 24 for maintenance) Side 3 Side 3 18

51U Series The 51U series is well suited for residential/commercial applications such as small restaurants and beauty salons. Utilizing commercial-grade copper alloy for the heat exchanger tubing, the 51U series is also suitable for heavier-residential usages such as combination space heating and domestic recirculation systems. Remote control included as a standard feature. ATI-51U-NI ATO-51U-NE 2. Exterior view 11U Indoor (T-KJr2U-IN) 31U Indoor (T-K4U-IN) 51U Indoor (T-D2U-IN) Dimensions Front view Side view 3-5/8" (94 mm) 13-3/4" (35 mm) 1" (254 mm) 7" (18 mm) 4" (11 mm) 4-3/8" (113 mm) 2-1/4" (52mm) 1-3/8" (36 mm) 2-1/4" (58 mm) 19-3/8" (493 mm) 1-7/8" (47 mm) HOT 4-5/8" (116 mm) 12 VAC 1-5/8" (4 mm) COLD 1-5/8" (41 mm) GAS 5" (127 mm) 1" (26 mm) 12 VAC 3" (75 mm) GAS 5-1/4" (135 mm) COLD 6" (153 mm) HOT 6" (153 mm) 9-1/2" (241 mm) Top view Bo om view 19 HOT 4-5/8" (119 mm) (127 mm) COLD 4-7/8" (124 mm) GAS 1-1/2" (38 mm) 113 mm) 13-1/8" (334 mm) 5-1/8" (13 mm)

Specifications Thicker heat exchanger drum and utilizes commercial-grade copper (heat-resistant) copper for the heat exchanger tubing. Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Easy-Link System capable up to 4 units. Multi- Link system capable up to 2 units. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. Indoor models include both a remote control and power cord as standard features. Outdoor models include remote control as a standard feature. Installation Type Dimension Indoor, Outdoor, Direct Vent 2-1/4" (H) X 13-3/4" (W) X 9-1/2" (D), Weight: 39 lbs Electric 12 V 82 W /.86 A (Operation) 7 W /.9 A (Standby) 132 W / 1.1 A (Freeze-Protection) Ignition Noise Level Fuel Electronic Ignition IN: 54 db OS: 58 db at Max output NG Gas Consumption Min. Input 15, BTU/h Max. Input 199, BTU/h Energy Factor.82 Gas Pressure Min 5." W.C. Max 1.5" W.C. Flow Rate 1. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.2 Gallons Water Pressure 15-15 PSI Pressure Only Relief Valve Requires (Min 2, BTUs. 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Easy-Link System Up to 4 units With no need for a system controller Installation Multi-Unit System Up to 2 units Multi-Controller (9835) 51U Temperature Settings Dipswitches 12 F (default) 14 F 51U: T-D2: Flow Flow Rate Rate vs. vs. Temperature Temperature Rise Rise 51U: 51: Pressure Loss Loss Flow Rate (gpm) 12 1 8 6 4 2 2 4 6 Set temperature: 13 F or lower Set temperature: 135 F or higher 8 1 12 Temperature Rise ( F) 14 With 99695 remote (max. distance 4 from heater, non-polarized 12 gauge wiring.) 1 F to 16 F (13 options), 12 F Default Factory Setting 5 45 4 35 3 25 2 15 1 5. 2. 4 Set temperature: 13 F or lower Set temperature: 135 F or higher 6. 8. 1. Flow Rate (gpm) 12 11 1 9 8 7 6 5 4 3 2 1 Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Indoor Installations Side 3 Side 3 Outdoor Installations Side 3 Side 3 Front 4 Front 4 (Recommended 24 for maintenance) (Recommended 24 for maintenance) Side 3 Side 3 Side 3 Side 3 2

14H Series The 14H Series is a high efficiency, ultra-low NOx condensing model with a.93 Energy Factor, allowing for the use of 3 or 4 PVC venting or Category IV stainless steel. ATI-14H-NIH ATO-14H-NEH CONDENSING Dimensions INDOOR MODEL Front view Side view 13-7/8" (352mm) 1" (254mm) 6-1/4" (158.5mm) 4" (12mm) 4" (12mm) 1-13/16" (274.6mm) 1-5/16" (262.2mm) 6" (152.1mm) 58.4 2-9/16" (64.8mm) 2-3/4" (7.2mm) 24" (69.4mm) 22-7/8 (58mm) Hot 4-3/4" (121.1mm) Condensate drain port 5-1/16" (129.1mm) 5-3/8" (137mm) 7-1/16" (18mm) Cold 1/2" (13.3mm) 12VAC 3-1/16" (77mm) Gas 4/1/2" (113.7mm) 1" (25.5mm) Condensate drain port 3-1/4" (82.1mm) Gas 4-1/8" (15.4mm) Hot 6-1/2" (164.6mm) Cold 7" (178.5mm) 12VAC 7-3/4" (196.5mm) Bo om view Top view 13-5/16" (338.1mm) 21 HOT 6-1/2" (165.3mm) Condensate drain port 3-1/4" (82.8mm) 6.1mm) 7-1/16" (179.2mm) LD 7-3/4" (197.2mm) AC 6" (152.1mm)

Specifications Provides a variety of installation options: indoor, outdoor and power direct vent design. Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor model includes a wall mount temperature remote controller and advanced diagnostics for troubleshooting. Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent or Category IV Stainless Steel 22-7/8" (H) X 13-7/8" (W) X 1-3/4" (D), Weight: 44 lbs Electric 12 V 54 W /.7 A (Operation) 3 W /.5 A (Standby) 224 W / 2 A (Freeze-Protection) Ignition Electronic Ignition Noise Level IN: 47 db OS: 52 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 15, BTU/h Max. Input 12, BTU/h 12, BTU/h Energy Factor.93.93 Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4 NPT / 1/2" NPT Coil Capacity.5 Gallons Water Pressure 15-15 PSI Pressure Only Relief Valve Requires (Min 12, btu/h, 15 PSI). 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multiple Unit Installation Multi-Unit System N/A N/A 14H Temperature Settings Built In / without remote 12 F (Default) 14 F With 99695 remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F with 5 F intervals (9 options), 12 F Default Factory Setting 14H: 14H: Flow Flow Rate Rate vs. vs. Temperature Rise Rise 14H: 14H: Pressure Loss Flow Rate (gpm) 1 9 8 7 6 5 4 3 2 1 2 4 6 8 1 12 14 Temperature Rise ( F) Pressure Loss (psi) 6 55 5 45 4 35 3 25 2 15 1 5. 1. 14 12 1 8 6 4 2 2. 3. 4. 5. 6. 7. 8. 9. 1. Flow Rate (gpm) Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Outdoor Installations Front 4 22

24H Series The 24H series offers high efficiency Ultra-Low NOx condensing technology allowing for the use of 3 PVC venting and has clearance to combustibles. ATI-24H-NIH ATO-24H-NEH Dimensions 4" (12 mm) Female 17-3/4" (45 mm) 7" (18 mm) 4" (11 mm) 4" (12 mm) Female 11-1/4" (285 mm) 5-3/4" (147 mm) 24-7/8" (631 mm) 23-5/8" (6 mm) 6-1/4" (159mm) 22-1/22" (57 mm) Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) 1-3/4" (272mm) HOT 4-3/4" (12 mm) Drain port 6-3/4" (17 mm) COLD 5/8" (17 mm) 12 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (14 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 12 VAC 6-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) HOT 4-3/4" (12 mm) Condensate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 12 VAC 3" (77 mm) 23 HOT 5-1/2" (14 mm) 12 VAC 6-7/8" (174 mm) GAS 5-1/8" (131 mm) COLD 6-3/4" (172 mm) Condensate drain port 7-7/8" (199 mm) 5-3/4" (147 mm) 17-5/8" (448 mm) COLD 5/8" (17 mm) 6-1/4" (159 mm)

Bottom 12 Bottom 12 Bottom 12 Bottom 12 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Warranty Information** Residential Use: 15 years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor model includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent, Category IV Stainless Steel 23-5/8" (H) X 17-3/4" (W) X 11-1/4" (D), Weight: 58 lbs Electric 12 V 73 W /.61 A (Operation) 3 W /.3 A (Standby) Ignition Electronic Ignition 174 W / 1.5 A (Freeze- Protection) Noise Level IN: 5 db OS: 53 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 13, BTU/h Max. Input 16, BTU/h 16, BTU/h Energy Factor.95.95 Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 6.6 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.5 Gallons Water Pressure 15-15 PSI Pressure Only Relief Valve Requires (Min 16, btu/h, 15 PSI). 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multiple Unit Installation Multi-Unit System N/A N/A 24H Temperature Settings Built In / without remote 12 F (Default) 14 F With 99695 remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F with 5 F intervals (9 options), 12 F Default Factory Setting 24H: 24H: Flow Rate Flow Rate vs. Temperature vs. Temperature Rise Rise 24H: 24H: Pressure Pressure Loss Loss Flow Rate (gpm) 1 9 8 7 6 5 4 3 2 1 Pressure Loss (psi) 5 45 4 35 3 25 2 15 1 5 12 1 8 6 4 2 Head (ft) 2 4 6 8 1 12. 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. Temperature Rise ( F) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Top 12 Top 12 Back.5 Back.5 Outdoor Installations Top 36 Top 36 Back.5 Back.5 Front 4 Front 4 (Recommended 24 for maintenance) (Recommended 24 for maintenance) Front 24 Front 24 24

34H Series The 34H series offers high efficiency Ultra-Low NOx condensing technology allowing for the use of 3 PVC venting and has clearance to combustibles. Indoor models are certified up to 1,1 ft. altitude. ATI-34H-NIH ATO-34H-NEH Dimensions 4" (12 mm) Female 17-3/4" (45 mm) 7" (18 mm) 4" (11 mm) 4" (12 mm) Female 11-1/4" (285 mm) 5-3/4" (147 mm) 24-7/8" (631 mm) 23-5/8" (6 mm) 6-1/4" (159mm) 22-1/22" (57 mm) Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) 1-3/4" (272mm) HOT 4-3/4" (12 mm) Drain port 6-3/4" (17 mm) COLD 5/8" (17 mm) 12 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (14 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 12 VAC 6-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) HOT 4-3/4" (12 mm) Condensate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 12 VAC 3" (77 mm) 25 HOT 5-1/2" (14 mm) 12 VAC 6-7/8" (174 mm) GAS 5-1/8" (131 mm) COLD 6-3/4" (172 mm) Condensate drain port 7-7/8" (199 mm) 5-3/4" (147 mm) 17-5/8" (448 mm) COLD 5/8" (17 mm) 6-1/4" (159 mm)

Bottom 12 Bottom 12 Bottom 12 Bottom 12 Specifications Provides a variety of installation options: indoor, outdoor, and direct vent. Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor model includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent, Category IV Stainless Steel 23-5/8" (H) X 17-3/4" (W) X 11-1/4" (D), Weight: 58 lbs Electric 12 V 78 W /.65 A (Operation) 3 W /.3 A (Standby) 174 W / 1.5 A (Freeze-Protection) Ignition Noise Level Electronic Ignition 55 db at Max output Fuel NG LP Min. Input 15, BTU/h 13, BTU/h Gas Consumption Max. Input 18, BTU/h 18, BTU/h Energy Factor.95.95 Min 5." W.C. Min 8." W.C. Gas Pressure Max 1.5" W.C. Max 14." W.C. Flow Rate Hot/Cold/Gas Connection Coil Capacity Water Pressure Multiple Unit Installation 34H Temperature Settings 8. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition 3/4" NPT.5 Gallons Pressure Only Relief Valve Requires (Min 18, btu/h, 15 PSI). 15-15 PSI 4 psi or above recommended for max. flow Easy-Link System N/A N/A Multi-Unit System N/A N/A Built In / without remote 12 F (Default) 14 F With 99695 remote (max. distance 4 from heater, non-polarized 2 gauge wiring.) 1 F to 14 F with 5 F intervals (9 options), 12 F Default Factory Setting 34H: Pressure Loss 34H: Flow 34H: Rate Flow vs. Rate Temperature vs. Temperature Rise Rise 34H: Pressure Loss 1. 5 12 9. 8. 45 4 1 Flow Rate (gpm) 7. 6. 5. 4. 3. 2. 1.. 2 4 6 8 1 12 Pressure Loss (psi) 35 3 25 2 15 1 5. 1. 8 6 4 2 2. 3. 4. 5. 6. 7. 8. 9. 1. Head (ft) Temperature Rise ( F) Flow Rate (gpm) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Top 12 Top 12 Back.5 Back.5 Outdoor Installations Top 36 Top 36 Back.5 Back.5 Front 4 Front 4 (Recommended 24 for maintenance) (Recommended 24 for maintenance) Front 24 Front 24 26

54H Series The 54H is well suited for residential/ commercial applications such as small restaurants and beauty salons. Complies with Ultra-Low NOx regulations. Utilizing commercial-grade copper alloy for the heat exchanger tubing, the 54H is also suitable for heavier residential usages such as combination space heating and domestic recirculation systems. Remote control included as a standard feature. Indoor models are certified up to 1,1 ft. altitude. ATI-54H-NIH ATO-54H-NEH Dimensions 4" (12 mm) Female 17-3/4" (45 mm) 7" (18 mm) 4" (11 mm) 4" (12 mm) Female 11-1/4" (285 mm) 5-3/4" (147 mm) 24-7/8" (631 mm) 23-5/8" (6 mm) 6-1/4" (159mm) 22-1/22" (57 mm) Exhaust 2-5/8" (65 mm) Intake 2-5/8" (68 mm) 1-3/4" (272mm) HOT 4-3/4" (12 mm) Drain port 6-3/4" (17 mm) COLD 5/8" (17 mm) 12 VAC 3" (77 mm) GAS 5-3/4" (147 mm) Condensate drain port 7-1/2" (189 mm) 1/2 (13 mm) GAS 5-1/8" (131 mm) HOT 5-1/2" (14 mm) Drain port 6" (152 mm) COLD 6-3/4" (172 mm) 12 VAC 6-7/8" (174 mm) Condensate drain port 7-7/8" (199 mm) HOT 4-3/4" (12 mm) Condensate drain port 7-1/2" (189 mm) GAS 5-7/8" (147 mm) 12 VAC 3" (77 mm) 27 OT 5-1/2" (14 mm) 2 VAC 6-7/8" (174 mm) AS 5-1/8" (131 mm) OLD 6-3/4" (172 mm) ondensate drain port -7/8" (199 mm) 5-3/4" (147 mm) 17-5/8" (448 mm)

Bottom 12 Bottom 12 Bottom 12 Bottom 12 Specifications Thicker heat exchanger drum and utilizes commercial-grade copper for the heat exchanger tubing. Provides a variety of installation options: outdoor, and direct vent. Complies with SCAQMD Rule 1146.2 and other air quality management districts with similar NOx Emission requirements of 14 ng/j or 2 PPM. Easy-Link System capable up to 4 units. Multi-Link System capable up to 2 units. Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts **Refer to www.hotwater.com for further warranty details. Indoor model includes a built-in temperature controller and advanced diagnostics to simplify troubleshooting. Outdoor models includes a wall mount temperature remote controller and advanced diagnostics to simplify troubleshooting. 54H: Flow 54H: Rate Flow vs. Rate Temperature vs. Temperature Rise Rise Installation Type Dimension Indoor, Outdoor, SCH 4 PVC Direct Vent, Category IV Stainless Steel 23-5/8" (H) X 17-3/4" (W) X 11-1/4" (D), Weight: 59 lbs Electric 12 V 89 W /.74 A (Operation) 4 W /.4 A (Standby) 175 W / 1.5 A (Freeze-Protection) Ignition Electronic Ignition Noise Level IN: 51 db OS: 56 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 13, BTU/h Max. Input 199, BTU/h 199, BTU/h Energy Factor.95.95 Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 1. GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition Hot/Cold/Gas Connection 3/4" NPT Coil Capacity.5 Gallons Water Pressure 15-15 PSI Pressure Only Relief Valve Requires (Min 2, btu/h, 15 PSI). 4 psi or above recommended for max. flow Easy-Link System Up to 4 units With no need for a system controller Multiple Unit Installation Multi-Unit System Up to 2 units Multiple-Unit Controller 9835 54H Temperature Settings Built In / without remote 12 F (Default) 14 F With 99695 remote (max. distance 4 from heater, non-polarized 16 gauge wiring.) 1 F to 16 F with 5 F intervals (13 options), 12 F Default Factory Setting 54H: Pressure Loss 54H: Pressure Loss 11 1 9 8 7 6 5 4 3 2 1 2 4 Set temperature: 125 F or lower Set temperature: 13 F or higher 6 8 1 12 14 Pressure Loss (psi) 5 45 4 35 3 25 2 15 1 5. 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. Set temperature: 125 F or lower Set temperature: 13 F or higher Flow Rate (gpm) 1 8 6 4 2 Head (ft) Clearance Clearances to Combustible and Non-Combustible Surfaces Direct Vent Installations Top 12 Top 12 Back.5 Back.5 Outdoor Installations Top 36 Top 36 Back.5 Back.5 Front Front 4 4 (Recommended 24 24 for maintenance) for Front 4 Front 4 (Recommended (Recommended 24 24 for maintenance) for maintenance) 28

91 Series The 91 Series, specifically designed for heavy-duty applications, is the largest A. O. Smith tankless heater yet and the most powerful (14.5 GPM max) in the tankless industry. The 91 Series is suitable for commercial applications (hotels, restaurants, government, convalescent homes, etc.) that require high demand and the most durable of heaters. Along with commercial-grade copper alloy, the 91 Series is the only commercial unit in the industry that offers a dual-combustion system, providing redundancy for added reliability. ATIO-91-NIEA Dimensions 29

Specifications Thicker heat exchanger drum and utilizes commercial-grade copper for the heat exchanger tubing. Incorporates a dual system for redundancy, providing added assurance that the 91 Series will remain operational. Includes an internal pump control port. Easy-Link System capable up to 4 units. Multi- Unit System capable up to 1 units. An ASME version of the 91 Series is also available.* Warranty Information** Residential Use: 15 Years limited heat exchanger, 5 Years limited parts Commercial Use: 1 Years limited heat exchanger, 5 Years limited parts * ASME models do not utilize commercial-grade copper alloy. **Refer to www.hotwater.com for further warranty details. Installation Type Dimension ATIO-91 Temperature Settings Indoor, Outdoor, Direct Vent 25-1/4 (W) X 24-7/8 (H) X 12-1/4 (D), Weight: 112 lbs Electric 12 VAC 178 W / 1.48 A (Operation) 16 W /.13 A (Standby) 271 W / 2.26 A (Freeze-Protection) Ignition Electronic Ignition Noise Level 61 db at Max output Fuel NG LP Gas Consumption Min. Input 15, BTU/h 15, BTU/h Max. Input 38, BTU/h 38, BTU/h Thermal Efficiency 8.2% 82.4% Gas Pressure Min 5." W.C. Min 8." W.C. Max 1.5" W.C. Max 14." W.C. Flow Rate 14.5 GPM Values based on factory testing..4 GPM required for continuous fire after initial ignition. Hot/Cold/Gas Connection 1 NPT Coil Capacity.32 Gallons Water Pressure 15-15 PSI Pressure Only Relief Valve Requires (Min 38, btu/h, 15 PSI). 4 psi or above recommended for max. flow Multiple Unit Installation Easy-Link System Up to 4 units With no need for a system controller Multi-Unit System Up to 1 units With 976755 (Multiple Unit System Controller) Dipswitches 1 F 115 F 12 F (default) 135 F 145 F 155 F 165 F 185 F With 97635 remote (max. distance 4 from heater, non-polarized 2 gauge wiring) 1 F 15 F 11 F 115 F 12 F (default) 125 F 13 F 135 F 14 F 145 F 15 F Default Mode 155 F 16 F 165 F 17 F 175 F High Temp. Mode 11 F 115 F 12 F (default) 125 F 13 F 135 F 14 F 145 F 15 F 155 F 16 F 165 F 17 F 175 F 18 F 185 F 91: Flow Rate vs. Temperature Rise 91: Pressure T-M5 Pressure Loss Loss 16 25 14 12 2 5 1 8 6 4 2 Pressure Loss (psi) 15 1 5 4 3 2 1 Head (ft) 25 45 65 85 15 125 145. 2. 4. 6. 8. 1. 12. 14. 16. Set temperature: 145 F or lower Set temperature: 15 F or higher Set temperature: 145 F or lower Set temperature: 15 F or higher Flow Rate (gpm) Clearance Indoor Installations Outdoor Installations Clearances to Combustible and Non-Combustible Surfaces Back.5 Back.5 3

EASY-LINK SYSTEM For larger applications that require multiple water heaters to work in conjunction, the 51, 51U, 54H, and 91 Series feature the Easy- Link system. This allows installers to easily manifold up to 4 units without the need for a system controller. The controls are already built into each model s internal computer. The Easy-Link system ensures proper modulation, using only the amount of energy required so that there is never any waste. Refer to each model s installation instructions for details. 31

MULTI- UNIT SYSTEM For even larger applications, the 51U, 54H and 91 Series models also feature the Multi-Unit system, allowing a greater number of units to manifold together. The Multi-Unit System Controller is necessary to enable the Multi-Unit system. The Multi-Unit System can control up to twenty 51Us, 54Hs, and ten 91s. UNIT COMPARISON 51 Series 51U* Series 54H* Series 91 Series** EASY-LINK (No Controller Necessary) Up to 4 units Up to 4 units Up to 4 units Up to 4 units Maximum input (BTU/h) 796, 796, 796, 1,52, MULTI-UNIT N/A Up to 2 units Up to 2 units Up to 1 units Maximum input (BTU/h) N/A 3,98, 3,98, 3,8, *51U and 54H models use 9835 controller for multi-link capabilities **With 976755 controller 32

APPLICATION DIAGRAMS A. O. Smith tankless water heaters can be used in a wide variety of applications. Whether used in recirculation systems, in conjunction with storage tanks or with heating applications, our commercial units are built to provide endless, continuous hot water.* *Local codes dictate proper compliance Basic Installation Subsequent units in Easy-Link or Multi-Unit Systems Single Unit H C H C Legend Pump Expansion Tank Hot Water Outlet Gas Supply Cold Water Inlet Shut Off / Isolation Valves * When manifolding State water heaters, whether in Easy-Link or Multi-Unit Systems, all water heaters are to be plumbed in parallel. Check Valve Union Pressure Relief Valve Recirculation Systems Air Vent *A Single Unit Air Separator S Air Vent Hot Water Outlet to Fixtures H C Y-Strainer Gas Supply *A. O. Smith tankless water heaters provide endless hot water when sized appropriately for your home s needs. S Air Separator Recirculation Pump *C Y-Strainer Cold water Inlet 33

Storage Tank (3 Tappings) *A The air vent is to be installed at the highest location of the system. The diameter of the pipe leading up the air vent is to be no smaller than the piping throughout the system. Hot Water Outlet to Fixtures Storage Tank Air Vent *A Air Separator S H C Gas Supply *B 1. The tank circulation pump is to be controlled by: Dual-set aquastat (recommended w/ timer) OR A. O. Smith Pump Control set to Storage Tank Mode (if the A. O. Smith model or controller has this function) 2. The tank circulation pump is to provide no less than 2 gpm through each activated A. O. Smith unit in the system. (Exception: no less than 4 gpm through each 91 series) *C 1. The recirculation pump is to be controlled by: Dual-set aquastat (recommended w/ timer) OR A. O. Smith Pump Control set to Recirculation Mode (if the A. O. Smith model or controller has this function) 2. The recirculation pump is to provide no less than 2 gpm and no more than 4 gpm through each activated A. O. Smith unit in the system. (Exception: between 4 gpm and 8 gpm through each 91 series) Drain Tank Circulation *B Y-Strainer Cold Water Inlet Hot Water Return (Optional) *D 1. The recirculation pump is to be controlled by: Dual-set aquastat (recommended w/ timer) OR A. O. Smith Pump Control set to Recirculation Mode (if the A. O. Smith model or controller has this function) OR Thermostat controlling the heating application 2. The recirculation pump is to provide no less than 2 gpm through each activated A. O. Smith unit in the system. (Exception: no less than 4 gpm through each 91 series model) *E The pump size and control are dependant on the requirements of the heating application. Air Vent *A Heating (Combination with domestic option) Depending on the application, the system may require a priority switch or priority control. Heating Application (Radiant, Baseboard, Hydronic Air, Etc) Pump *E Heat Exchanger S Tempered Water to House T Thermostatic Mixing Valve Recirculation Pump *D H C Gas Supply All application diagrams shown are concept drawings only. These diagrams are only to be used as basic guides. It is up to the application designer to properly design the plumbing layout and correctly size all components within an application (pumps, piping, storage tanks, water heaters, etc.). All national and local codes must be followed and will dictate proper compliance. Y-Strainer Cold water Inlet 34

MULTI-UNIT WITH STORAGE Air Vent * Multi-Unit Controller 976755 (TM-MC1) Hot Water Outlet to Fixtures Tankless Water Heater H C H Tankless Water Heater C ULN Models use 9835 (TM-MC-2) *5 or more units require a multi-unit controller Gas Supply Storage Tank Drain Tank Circulation ** Cold Water Inlet Y-Strainer Hot Water Return (Optional) * The air vent is to be installed at the highest location of the system. The diameter of the pipe leading up the air vent is to be no smaller than the piping throughout the system ** 1. The tank circulation pump is to be controlled by: Dual-set aquastat (recommended w/ timer) OR Unit Pump Control set to Storage Tank Mode (if the unit model or controller has this function) ** 2. The tank circulation pump is to provide no less than 2 gpm through each activated unit in the system. (Exception: no less than 4 gpm through each 91 series) 35

SOLAR TANKLESS BACK UP COLLECTOR SENSOR TANKLESS WATER HEATER H C TEMPERED HOT WATER SOLAR COLLECTOR GAS SUPPLY T AQUASTAT TANK SENSOR SOLAR CONTROL COLD WATER INLET STORAGE TANK * The air vent is to be installed at the highest location of the system. The diameter of the pipe leading up the air vent is to be no smaller than the piping throughout the system ** 1. Control of the primary loop pump is dependent on the requirement of the heating application. ** 2. The primary loop pump is to provide no less than 2 gpm through each activated A. O. Smith unit in the system (Exception: no less than 4 gpm through each 91 series) *** Size of zone pumps and method of control are dependent on the requirements of the heating application. 36

VENTING DIAGRAMS (EXAMPLES) 4 Sidewall Termination 3 (Please check the wall thickness for proper installation) 2 1 Models 11/U, 31/U, 51/U 4 Combustible Sidewall Termination Qty. 4 Kit Part Number: 983395 1 979995 4" Sidewall Hood Terminator 1 2 983455 4" Wall Thimble (4."-7.") 1 3 97985 4" 9 degree Elbow 1 4 979795 4" Female-Female Adaptor 1 1 2 3 Models 11/U, 31/U, 51/U 4" Non-Combustible Sidewall Termination Qty. Kit Part Number: 984815 1 979995 4" Sidewall Hood Terminator 1 2 97985 4" 9 degree Elbow 1 3 979795 4" Female-Female Adaptor 1 37

Up & Out Standard Installation Combustible Wall 4 Sidewall Termination (With Condensate Trap) 3 (Please check the wall thickness for proper installation) 1 Models 11/U, 31/U, 51/U 4" Combustible Sidewall Termination (With Condensate Trap) Qty. Kit Part Number: 984895 1 979995 4" Sidewall Hood Terminator 1 2 983455 4" Wall Thimble (4."-7.") 1 3 97985 4" 9 degree Elbow 1 4 981465 4" Universal Appliance Adaptor 1 4 2 1 2 3 Models 11/U, 31/U, 51/U 4" Non-Combustible Sidewall Termination (With Condensate Trap) Qty. Kit 4 Part Number: 98495 1 979995 4" Sidewall Hood Terminator 1 2 97985 4" 9 degree Elbow 1 3 981465 4" Universal Appliance Adaptor 1 38

DIRECT VENT, CONCENTRIC SIDEWALL TERMINATION 11/U, 31/U, 51/U Models 1 Models 11/U, 31/U, 51/U 5-1 Sidewall Thickness Direct Vent, Concentric Termination Qty. 1 981475 Concentric Intake/Exhaust Kit 1 3 Kit Part Number: 9815 2 981465 Universal Appliance Adaptor 1 3 N/A 3 Aluminum Flex 1 4 976675 Direct Vent Conversion Kit 1 12-18 Sidewall Thickness Direct Vent, Concentric Termination Qty. 2 Kit Part Number: 985 1 981475 Concentric Intake/Exhaust Kit 1 2 981465 Universal Appliance Adaptor 1 3 N/A 3 Aluminum Flex 1 4 4 976675 Direct Vent Conversion Kit 1 91 Model 1 3 Model 91 5-1 Sidewall Thickness Direct Vent, Concentric Termination Qty. 4 2 Kit Part Number: 98215 1 98285 Concentric Intake/Exhaust Kit 1 2 98215 Universal Appliance Adaptor 1 3 N/A 5 Aluminum Flex 1 4 976695 Direct Vent Conversion Kit 1 12-18 Sidewall Thickness Direct Vent, Concentric Termination Qty. 1 98295 Concentric Intake/Exhaust Kit 1 Kit Part Number: 98255 2 98215 Universal Appliance Adaptor 1 3 N/A 5 Aluminum Flex 1 4 976695 Direct Vent Conversion Kit 1 39

Vertical Venting: Flat Roof Termination 4 Rooftop Termination 3 1 2 7 Models 11/U, 31/U, 51/U 4 Flat Roof Termination Qty. Kit Part Number: 98345 1 981455 4 Extreme Weather Rain Cap 1 2 97995 4 Storm Collar 1 3 979925 4 Flat Roof Flashing 1 4 979885 4 Vertical Firestop 1 5 97985 4 9 degree Elbow 2 6 981465 4 Universal Appliance Adaptor 1 7 Refer to page 44 Straight Pipe TBD 4 2 1 3 7 5 7 6 4 Models 11/U, 31/U, 51/U 4 Angled Roof Termination Qty. Kit Part Number: 983415 1 981455 4 Extreme Weather Rain Cap 1 2 97995 4 Storm Collar 1 3 979915 4 Angeled Roof Flashing 1 4 979885 4 Vertical Firestop 1 5 97985 4 9 degree Elbow 2 6 981465 4 Universal Appliance Adaptor 1 7 Refer to page 44 Straight Pipe TBD 7 6 5 4

5 Sidewall Termination 4 3 2 1 Model 91 5" Combustible Sidewall Termination Qty. Kit Part Number: 983425 1 981975 5" Sidewall Hood Terminator 1 2 983475 5" Wall Thimble (4."-7.") 1 3 981885 5" 9 degree Elbow 1 4 98235 5" Female-Female Adaptor 1 2 1 3 Model 91 5" Non-Combustible Sidewall Termination Qty. Kit 8 Part Number: 984825 1 981975 5" Sidewall Hood Terminator 1 2 981885 5" 9 degree Elbow 1 3 98235 5" Female-Female Adaptor 1 41

5 Sidewall Termination (With Condensate Traps) 2 Model 91 4 3 1 5" Combustible Sidewall Termination (With Condensate Trap) Qty. Kit 9 Part Number: 984915 1 981975 5" Sidewall Hood Terminator 1 2 983475 5" Wall Thimble (4."-7.") 1 3 981885 5" 9 degree Elbow 1 4 98215 5" Universal Appliance Adaptor 1 1 2 3 Model 91 5" Non-Combustible Sidewall Termination (With Condensate Trap) Qty. Kit 1 Part Number: 984925 1 981975 5" Sidewall Hood Terminator 1 2 981885 5" 9 degree Elbow 1 3 98215 5" Universal Appliance Adaptor 1 42

5 Rooftop Termination 3 1 7 2 7 Model 91 5 Flat Roof Termination Qty. Kit Part Number: 983435 1 9825 5 Extreme Weather Rain Cap 1 2 981935 5 Storm Collar 1 3 981955 5 Flat Roof Flashing 1 4 981945 5 Vertical Firestop 1 5 981885 5 9 degree Elbow 2 6 98215 5 Universal Appliance Adaptor 1 7 Refer to page 44 Straight Pipe TBD 1 4 3 7 2 6 5 4 7 Model 91 5 Angled Roof Termination Qty. Kit Part Number: 983445 1 9825 5 Extreme Weather Rain Cap 1 2 981935 5 Storm Collar 1 3 981965 5 Angled Roof Flashing 1 4 981945 5 Vertical Firestop 1 5 981885 5 9 degree Elbow 2 6 98215 5 Universal Appliance Adaptor 1 7 Refer to page 44 Straight Pipe TBD 7 6 5 43

VENTING COMPONENTS Simple Leak-Proof Gasketed Connections No Sealant Required. High Quality Category III / IV Stainless Steel. Versatile Vertical and Horizontal Terminations. Convenient Vent Kits Available. UL Listed. All Connections have Heat-Resistant Rubber Gaskets. Nova Vent Part # DESCRIPTION STRAIGHT VENT PIPE Nova Vent Part # DESCRIPTION BACKFLOW PREVENTER 979875 4 Straight pipe - 6 Length 979865 4 Straight pipe - 12 Length 979845 4 Straight pipe - 24 Length 979835 4 Straight pipe - 36 Length 979825 4 Straight pipe - 48 Length 979965 98225 4 Backflow Preventer & F-F Adaptor 5 Back-flow Preventer & F-F Adaptor 981815 5 Straight pipe - 6 Length 981825 5 Straight pipe - 12 Length 981835 5 Straight pipe - 24 length 981845 5 Straight pipe - 36 Length 981855 5 Straight pipe - 48 Length ADJUSTABLE VENT PIPE CONDENSATION DRAIN 979945 4 Horizontal Drain Tee 981915 5 Horizontal Drain Tee 979935 (M-F) 4 Vertical Drain Tee 979855 4 Adjustable Pipe (7-9.9 ) 981925 5 Vertical Drain Tee 981865 5 Adjustable Pipe (7-9.9 ) ELBOW 979815 4 45 Degree Elbow 981875 5 45 Degree Elbow 97985 4 9 Degree Elbow SUPPORT 979895 4 Support Strap (1 ) 98245 5 Support Strap (1 ) WALL THIMBLE 983455 (4-7 ) 4 Wall Thimble 981885 5 9 Degree Elbow ADAPTOR 979795 4 Female-Female Adaptor 983465 (5-1 ) 983475 (4-7 ) 983485 (5-1 ) 4 Wall Thimble 5 Wall thimble 5 Wall thimble 98235 5 Female-Female Adaptor 4 SIDEWALL TERMINATION & THIMBLE KIT 981465 98215 4 Universal Appliance Adaptor 3-in-1 (F-F adaptor, condensate drain, & back-flow preventer) 5 Universal Appliance Adaptor 3-in-1 (F-F adaptor, condensate drain, & back-flow preventer) 9845 (4-7 ) 9855 (5-1 ) Sidewall Vent Terminator (Hood) and Wall Thimble Sidewall Vent Terminator (Hood) and Wall Thimble Note: 11/U, 14H, 31/U, 51/U, 24H, 34H, 54H series are compatible with 4 components. 91 series is compatible with 5 components. 44

Nova Vent Part # TERMINATION DESCRIPTION 981445 4 Termination Tee 981985 5 Termination Tee 979995 981975 4 Exhaust Sidewall Vent Terminator (Hood) 5 Exhaust Sidewall Vent Terminator (Hood) 979955 4 Rain Cap 981455 4 Extreme Weather Rain Cap 9825 5 Extreme Weather Rain Cap 976115 3 Concentric PVC Termination FIRESTOP 979885 Vertical Firestop 981945 5 Firestop ROOF FLASHING Nova Vent Part # DIRECT VENT, CONCENTRIC SIDEWALL TERMINATION KIT Includes : DV Conversion Kit, Concentric Termination, Universal Adaptor 3-in-1, Aluminum Flex and Gear Clamp 9815 985 98265 98275 98215 98255 DESCRIPTION INTAKE HOOD (GALVANIZED) 981425 3 981435 4 98185 5 5. to 1. 3 Intake, 4 Exhaust 12. to 18. 3 Intake, 4 Exhaust 5. to 1. 4 Intake, 4 Exhaust 12. to 18. 4 Intake, 4 Exhaust 5. to 1. 5 Intake, 5 Exhaust 12. to 18. 5 Intake, 5 Exhaust 979925 4 Flat Roof Flashing 981955 5 Flat Roof Flashing 979915 4 Angled Roof Flashing 981965 5 Angled Roof Flashing STORM COLLAR 97995 4 Storm Collar 981935 5 Storm Collar DIRECT VENT CONVERSION KIT 976675 976695 Direct Vent Conversion Kit for NIE models 11 (U) / 31 (U) / 51 (U) Direct Vent Conversion Kit for NIEA Model 91 Note: 11/U, 14H, 31/U, 51/U, 24H, 34H, 54H series are compatible with 4 components. 91 series is compatible with 5 components. 45

ACCESSORIES ACCESSORIES ATI-11/U ATO-11/U ATI-31/U ATO-31/U ATI-51/U ATO-51/U ATO-14 ATI-24 ATI-14 ATO-24 ATO-34 ATI-54 ATO-54 ATIO-91 ATI-34 976775 Outdoor Vent Cap x 976745 Recess Box x x x 976715 x x 97675 x* x* x x x x 976735 Pipe Cover x 983315 x x x x x x 989535 x x 976755 Multiple Unit Controller 9835 x* x* x x x 976665 Remote Temperature x x x x Controller (Not compatible with the Ultra-Low NOx 97635 models) x x x 981725 99695 Commercial Remote Temperature Controller Residential Remote Temperature Controller x* x* x x x* x* x* x* x* x* x x x x x x x x 97645 x x x x x x x x x x x x x x 97785 Isolation Valves (Lead Free) Isolation Valves (Lead Free) x 97675 Neutralizer x x x x x x x x 988465 988475 PVC Adapter for Common Venting Non-Return Valve for Common Venting x x x x x x 988715 Product Preservers LG1.5L w w w w w w c/w 988765 988775 988785 LG1.5L Replacement Cartridge Product Preservers SM1.L Anti-Scale System SM1.L Replacement Cartridge c/w c/w c/w c/w c c c/w c/w c/w c/w c c c c X = Standard Models X *= Ultra-Low NOx Models C = Cooler Climate W = Warmer Climate 46

Hard Water and Tankless Heaters Hard water can adversely affect plumbing systems, from water piping to water fixtures and even down to the water heating system. For piping and fixtures, hard water can create more pressure loss and reduce water flow. For water heaters, it can even reduce energy efficiency and damage the heater. This is especially true for tankless water heaters and it is important to understand what hard water is, what hard water does, and how to protect your tankless water heater from possible damage caused by hard water. What is hard water and hard water scale? Very simply, hard water is defined as water that has a high mineral content, specifically in magnesium and calcium (Ca 2+ and Mg 2+ ions). Hard water is not considered a health risk and these minerals generally remain dissolved in the water. However, the problems arise when the minerals precipitate out of the water and leave behind a solid mineral buildup. This buildup is called hard water scale, and it is this scale that reduces water flow through pipes and fixtures, reduces the energy efficiency of water heating equipment and, at worst, causes irreversible damage to the heat exchangers within tankless water heaters. It is important to note that the likelihood of scale formation is only based on the hardness levels of the water and the temperature of the water, not on the material the scale is adhering to. For example, hard water scale would form equally on a copper surface as it would on a stainless steel surface, given the same hardness level and temperature of water. What does hard water scale do to my water heater? When hard water scale forms a layer coating on the inside wall of a tankless heat exchanger fin pipe, it acts as a thermal insulator. This insulation effectively prevents a significant amount of heat from the burners to properly transfer into the water within the piping. Because the heat is not transferring into the water, the heat exchanger material is forced to retain this excess heat, eventually overheating and becoming damaged. Once the material has degraded enough, the heat exchanger piping eventually gives way and water leakage occurs. With Treatment Without Treatment Full water flow and heat transfer Full heat transfer Limited water flow Limited heat transfer Copper Fin Copper Tube Copper Fin Copper Tube Picture shows a clean HX with treatment. Scale buildup from untreated water. Burner Flow Rate Based Ground Water Temperature (assume 12 F Set point) Tankless Model 14H 11/U 24H 31/U 51/U 34H 54H 91 Input (BTU/h) 12 14 16 19 199 18 199 38 Output (BTU/h) 1116 1148 152 1558 16318 171 1895 34 85 6.4 6.56 6.6 8. 9.32 8. 1. 14.5 8 5.6 5.74 6.6 7.79 8.16 8. 9.45 14.5 75 5. 5.1 6.6 6.92 7.25 7.6 8.4 13.51 7 4.5 4.59 6.8 6.23 6.53 6.84 7.56 12.16 65 4.1 4.17 5.53 5.67 5.93 6.22 6.87 11.5 6 3.7 3.83 5.7 5.19 5.44 5.7 6.3 1.13 55 3.4 3.53 4.68 4.79 5.2 5.26 5.82 9.35 5 3.2 3.28 4.34 4.45 4.66 4.89 5.4 8.69 45 3. 3.6 4.5 4.15 4.35 4.56 5.4 8.11 4 2.8 2.87 3.8 3.9 4.8 4.28 4.73 7.6 35 2.6 2.7 3.58 3.67 3.84 4.2 4.45 7.15 Product Preservers protects your tankless heat exchanger from scale formation. Refer to the chart to the right to properly size for your application. Ground Water Temperature ( F) Colder Climate Warmer Climate 988775 Product Preservers SM1.L Anti-Scale System 988715 Product Preservers LG1.5L Anti-Scale System Requires multiple units 47

Where is hard water found? Hard water ALASKA is everywhere. In fact, more than 85% of American homes have hard water. ALASKA OVER 14 gpg Extremely Hard 1 to 14 gpg 7 to 1 gpg 3 to 7 gpg LESS than 3 gpg Very Hard OVER 14 gpg Hard 1 to 14 gpg Moderately hard 7 to 1 gpg Slightly Hard 3 to 7 gpg LESS than 3 gpg Extremely Hard Very Hard Hard Moderately hard Slightly Hard HAWAII HAWAII PUERTO RICO PUERTO RICO How is the hardness of water measured? Water hardness is measured in either parts per million (ppm) or grains per gallon (gpg). Anything that measures above 3 gpg is generally considered hard (Unites A. O. Smith s Geological Survey) and it is advised at this point to look into water treatment. The U.S. Department of Interior and the Water Quality Association have classified water hardness under several levels: CLASSIFICATION mg/l OR PPM (PARTS PER MILLION) GPG (GRAINS PER GALLON) Soft - 17-1 Slightly Hard 17-6 1-3.5 Moderately Hard 61-12 3.5-7. Hard 121-18 7. - 1.5 Very Hard 18 and above 1.5 and above How do I prevent hard water scale? Fortunately, there are quite a few great options to choose from when looking to protect water heating equipment from scale buildup. These solutions range in cost, maintenance and application, so it is always best to consult with water treatment professionals before making the final decision on a water treatment solution. Ion exchanger water softeners: Water softeners are probably the most common solution used today for eliminating hard water. Calcium and magnesium ions are removed from the water and replaced with sodium ions. Without the calcium and magnesium, hard water scale cannot form. Product Preservers : Prevents scale by transforming dissolved hardness minerals into harmless, inactive microscopic crystal particles. These crystals stay suspended in the water and are passed to drain. Siliphos: Interferes with the ability of (calcium and magnesium) scale to crystallize. The suspended scale stays in the water and goes down the drain. 48

Models Connection: Gas/Water Power Venting Intake Exhaust (Cat. III Stainless) Easy-Link (EL) Multi-Unit (MU) Temperature (with remote) GPM (Max) Per Unit I = Inside Energy Factor NG, LP NG Max (BTU/h), LP Max (BTU/h) O= Outside Dimension/ Weight 14H Series ATI-14 ATO-14 High efficiency ultra-low NOx condensing tankless. 3 PVC venting. clearance to combustible. 1/2 Gas 3/4 Water 12 VAC Intake & Exhaust 3, 7 Max, 5 elbow Max OR 4, 1 Max, 5 elbow Max (PVC venting capable) E = no venting required N/A 1 to 14 (1 to 14) 6.6 Energy Factor NG:.93 LP:.93 NG: 12, LP: 12, H = 22-7/8 W = 13-7/8 D = 1-3/4 DV = 44 lbs E = 44 lbs Condensing 24H Series ATI-24 34H Series ATI-34 ATO-24 ATO-34 High efficiency ultra-low NOx condensing tankless. 3 PVC venting. clearance to combustible. High efficiency ultra-low NOx condensing tankless. 3 PVC venting. clearance to combustible. 3/4 Gas/Water 12 VAC 3/4 Gas/Water 12 VAC Intake & Exhaust 3, 7 Max, 5 elbow Max OR 4, 1 Max, 5 elbow Max (PVC venting capable) E = no venting required Intake & Exhaust 3, 7 Max, 5 elbow Max OR 4, 1 Max, 5 elbow Max (PVC venting capable) E = no venting required N/A 1 to 14 (1 to 14) N/A 1 to 14 (1 to 14) 6.6 Energy Factor NG:.95 LP:.95 8. Energy Factor NG:.95 LP:.95 NG: 16, LP: 16, NG: 18, LP: 18, H = 23-5/8 W = 17-3/4 D = 11-3/4 DV = 58 lbs E = 58 lbs H = 23-5/8 W = 17-3/4 D = 11-3/4 DV = 58 lbs E = 58 lbs 54H Series ATI-54 ATO-54 High efficiency ultra-low NOx condensing tankless. 3 PVC venting. clearance to combustible. 3/4 Gas/Water 12 VAC Intake & Exhaust 3, 7 Max, 5 elbow Max OR 4, 1 Max, 5 elbow Max (PVC venting capable) E = no venting required (EL) 4 units (MU) 2 units 1 to 16 (1 to 16) 1. (4 units generate 4 GPM Max; 2 units generate 2 GPM Max) Energy Factor NG:.95 LP:.95 NG: 199, LP: 199, H = 23-5/8 W = 17-3/4 D = 11-3/4 DV = 59 lbs E = 59 lbs 11 Series Great for apartments, condos and summer cabins. ATI-11 ATO-11 3/4 Gas/Water 12 VAC I Model: 3 Intake, 5 Max 4 Intake, 5 Max N/A 113 to 14 (99 to 167) 6.6 Energy Factor NG:.82 LP:.82 NG: 14, LP: 14, H= 2-1/4 W= 13-3/4 D= 7-3/4 33 lbs Non-Condensing Low NOx 31 Series Adds 1 more shower over the 11 at minimal increase in cost. ATI-31 51 Series Well suited for light commercial applications. Commericalgrade copper ATI-51 ATO-31 ATO-51 3/4 Gas/Water 12 VAC 3/4 Gas/Water 12 VAC I Model: 3 Intake, 5 Max 4 Exhaust, 5 Max I Model: 3 Intake, 5 Max 4 Exhaust, 5 Max N/A 113 to 14 (99 to 167) (EL) 4 units (MU) 2 units for 51U only 14 to 185 (1 to 176) 8. Energy Factor NG:.82 LP:.82 1. (4 units generate 4 GPM Max; 51U generates up to 2 GPM Max) Energy Factor NG:.82 LP:.82 NG: 19, LP: 19, NG: 199, LP: 199, H= 2-1/4 W= 13-3/4 D= 9-1/2 38 lbs H= 2-1/4 W= 13-3/4 D= 9-1/2 39 lbs Non-Condensing 91 Series Generates Most GPM in tankless ASME industry. model available 14.5 GPM (Max). Commercialgrade copper alloy. LED display ATI-91 1 Gas/Water 12 VAC 5 Intake, 5 Max 5 Exhaust, 5 Max (EL) 4 units (MU) 1 units 1 to 185 (1 to 185) 14.5 (4 units generate 58 GPM Max; 1 units generate 145 GPM Max) Thermal Efficiency NG: 8.2% LP: 82.4% NG: 38, LP: 38, H= 25-1/4 W= 24-3/4 D= 11-3/4 112 lbs ATI-11, ATI-31 & ATI-51 are available in Ultra-Low NOx. Please see pages 15-2. 49

5 Tennessee Waltz Pkwy Ashland City, TN 3715 Toll Free: 8.527.1953 599 Hill Street West Fergus, ON N1M 2X1 Tel: 519.843.161 Fax: 519.787.55 Toll Free: 877.877.4953 5 Wald Irvine, CA 92618 Tel: 949.77.7171 Fax: 949.77.3171 A. O. Smith November 215 hotwater.com AOSBG8