R&S ZVA Vector Network Analyzer Specifications



Similar documents
R&S ZNC Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZCxxx Millimeter-Wave Converters Specifications

R&S SMZ Frequency Multiplier Specifications

R&S ZVL Vector Network Analyzer Specifications

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

R&S ZVB Vector Network Analyzer High measurement speed up to 20 GHz with two or four test ports

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

R&S FS-K130PC Distortion Analysis Software Amplifier modeling and linearization

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Impedance 50 (75 connectors via adapters)

R&S FS-K130PC Distortion Analysis Software Specifications

Agilent E5100A Network Analyzer

R&S VSE-K10x R&S FSx-K10x R&S FS-K10xPC EUTRA/LTE Measurement Software Specifications

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

Realtime FFT processing in Rohde & Schwarz receivers

R&S ZVA Vector Network Analyzer High performance up to 67 GHz with up to four test ports

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

One Port Network Analyzer

R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports

Network analyzer and spectrum analyzer two in one

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight N9320B RF Spectrum Analyzer

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

R&S ZNB Vector Network Analyzer Leading in speed, dynamic range and ease of operation

Agilent. E5071C ENA Network Analyzer. E5092A Configurable Multiport Test Set. Data Sheet

R&S EFL110/ R&S EFL210 Cable TV Analyzer and Leakage Detector Detecting interference in cable TV and LTE networks

R&S MKS9680 Modular Encryption Device Secure voice, fax and data transmission

R&S SMZ Frequency Multiplier Precise output levels from 50 GHz to 170 GHz

AM/FM/ϕM Measurement Demodulator FS-K7

NI USB-5681 RF Power Meter Specifications

Rohde & Schwarz Service that adds value

Agilent E5061B Network Analyzer 5 Hz to 3 GHz. Data Sheet

Using R&S FSW for Efficient Measurements on Multi- Standard Radio Base Stations Application Note

khz to 2.7 GHz Spectrum Analyzer

How To Use A Sound Card With A Subsonic Sound Card

Vector Network Analyzer Family ZVR

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

iva Cable & Antenna Analyzer

R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports

Agilent ENA-L RF Network Analyzers

R&S UMS170 Compact Radiomonitoring System High performance for outdoor deployment

WLAN Protocol Tester PTW 70

iva Cable & Antenna Analyzer

DS 600. A contact free flux gate based current measurement sensor 600A rms

R&S IP-GATE IP gateway for R&S MKS9680 encryption devices

R&S RTO Digital Oscilloscope Resolving Security Issues When Working in Secure Areas

R&S IP-GATE IP gateway for ISDN encryption devices

R&S Analysis Center Automatic radio network detection and situation picture visualization

Using R&S NRP-Z Power Sensors with Android TM Handheld Devices. Application Note. Products:

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

Production testing of radar sensors for automotive applications

Software Utility VNA Frequency Converter Leveling Tool Getting Started

PicoScope 6000A/B Series

Fast and Accurate Test of Mobile Phone Boards

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Agilent 4338B Milliohm Meter

R&S ESL EMI Test Receiver Compact, cost-effective measuring receiver

R&S AVG050 DVB Satellite Receiver Compact DVB-S and DVB-S2 satellite demodulator

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

R&S SLx8000 Family of UHF/VHF Transmitters Efficient solutions for analog and digital broadcasting standards

Lip-Sync Measurement (AV Delay) for TV Displays Application Note

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

HP 8590 E-Series Portable Spectrum Analyzers Technical Specifications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

FSP Spectrum Analyzer

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Agilent P940xA/C Solid State PIN Diode Switches

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

Spectral and Time-Domain Analysis of Recorded Wave Files on the Audio Analyzer R&S UPV Application Note

PLANAR 304/1 Vector Network Analyzer. Operating Manual

PERF10 Rubidium Atomic Clock

R&S SITGate Next-Generation Firewall Secure access to Internet and cloud services

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

R&S BC NETSTATE Open network management software for broadcast applications

Agilent Test Solutions for Multiport and Balanced Devices

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

R&S EFL240/R&S EFL340 Portable TV Test Receiver Professional installation of cable and satellite TV systems and antennas

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

Signal and Tracking Generator

Test Equipment Solutions Datasheet

Power Amplifier Gain Compression Measurements

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Audio Analyzers UP 300/ UP 350

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Agilent 8753ET/8753ES Network Analyzers

T200, PTP/IEEE 1588 Grandmaster Clock and

Field Calibration Software

Telephone- and leased line modem for industrial applications TD-36

DCS Series 1 kw, 1.2 kw, & 3 kw

R&S RCMS II Remote Control & Monitoring System For ATC and air defense applications

Transcription:

www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22 4:35:38

CONTENTS Definitions... 3 Specifications... 4 Measurement range... 4 Measurement speed... 8 Measurement accuracy... Effective system data... 9 Test port output... 2 Test port input... 25 Additional front panel connectors... 29 Optional front panel connectors... 29 Display... 29 Rear panel connectors... 29 Options... 3 General data... 35 Ordering information... 36 2 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 9 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 8 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz R&S ZVA Vector Network Analyzer 3

Specifications Specifications apply under the following conditions: 9 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and all internal automatic adjustments performed. "Typical values" are designated with the abbreviation "typ.". These values are verified during the final test but are not assured by Rohde & Schwarz. "Nominal values" are design parameters that are not assured by Rohde & Schwarz. These values are verified during product development but are not specifically tested during production. Unless otherwise stated, specifications apply to test ports and a nominal source power of dbm. Measurement range Impedance 5 Ω Test port connector R&S ZVA8 type N, female 3.5 mm, male, ruggedized 2.92 mm, male, ruggedized 2.4 mm, male, ruggedized 2.4 mm, male, ruggedized.85 mm, male, ruggedized Number of test ports 2 or 4 Frequency range R&S ZVA8 3 khz to 8 GHz MHz to 24 GHz MHz to 4 GHz MHz to 5 GHz MHz to 67 GHz Static frequency accuracy without optional oven quartz 8 6 with optional oven quartz 7 Frequency resolution Hz Number of measurement points user-selectable to 6 Measurement bandwidths /2/5 steps Hz to MHz Dynamic range of the R&S ZVA8 (without optional step attenuators and without optional direct from PORT to PORT 2 and from PORT 3 to PORT 4 3 khz to 5 MHz > db, typ. db generator/receiver access) 5 MHz to MHz > 2 db, typ. 3 db MHz to 4 GHz > 3 db, typ. 4 db 4 GHz to 7 GHz > 25 db, typ. 35 db 7 GHz to 8 GHz > 2 db, typ. 3 db Dynamic range of the (without optional step attenuators and without optional direct generator/receiver access) Dynamic range of the (without optional step attenuators and without optional direct generator/receiver access) Dynamic range of the (without optional step attenuators and without optional direct generator/receiver access) from PORT to PORT 2 and from PORT 3 to PORT 4 MHz to MHz > 9 db, typ. 5 db MHz to 7 MHz > 5 db, typ. 2 db 7 MHz to 2 GHz > 25 db, typ. 3 db 2 GHz to 3 GHz > 3 db, typ. 35 db 3 GHz to 24 GHz > 25 db, typ. 3 db from PORT to PORT 2 and from PORT 3 to PORT 4 MHz to 5 MHz > 9 db, typ. db 5 MHz to 5 MHz > 5 db, typ. 5 db 5 MHz to 2 GHz > 25 db, typ. 35 db 2 GHz to 2 GHz > 3 db, typ. 4 db 2 GHz to 24 GHz > 25 db, typ. 35 db 24 GHz to 32 GHz > 2 db, typ. 3 db 32 GHz to 4 GHz > 8 db, typ. 25 db from PORT to PORT 2 and from PORT 3 to PORT 4 MHz to 5 MHz > 9 db, typ. db 5 MHz to 5 MHz > 5 db, typ. 5 db 5 MHz to 2 GHz > 25 db, typ. 35 db 2 GHz to 2 GHz > 3 db, typ. 4 db 2 GHz to 24 GHz > 25 db, typ. 35 db 24 GHz to 4 GHz > 2 db, typ. 3 db 4 GHz to 45 GHz > 5 db, typ. 25 db 45 GHz to 5 GHz > db, typ. 2 db 4 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Dynamic range of the (without optional step attenuators and without optional direct generator/receiver access) from PORT to PORT 2 and from PORT 3 to PORT 4 MHz to 5 MHz > 7 db, typ. 9 db 5 MHz to 5 MHz > db, typ. 25 db 5 MHz to 2 GHz > 2 db, typ. 3 db 2 GHz to 8 GHz > 3 db, typ. 4 db 8 GHz to 2 GHz > 25 db, typ. 4 db 2 GHz to 24 GHz > 3 db, typ. 4 db 24 GHz to 32 GHz > 2 db, typ. 3 db 32 GHz to 4 GHz > 5 db, typ. 25 db 4 GHz to 5 GHz > 5 db, typ. 25 db 5 GHz to 65 GHz > 7 db, typ. 5 db 65 GHz to 67 GHz > 5 db, typ. 5 db 67 GHz to 7 GHz typ. 3 db The dynamic range is defined as the difference between the actually available maximum source power and the RMS value of the data trace of the transmission magnitude, which is produced by noise and crosstalk with the test ports short-circuited. The specification is valid without system error correction and at Hz measurement bandwidth. The dynamic range can be increased by using a measurement bandwidth of Hz. For the at single frequencies below 2.5 GHz, the dynamic range may be affected by spurious signals. Dynamic range at optional measurement input (direct generator/receiver access option) of the R&S ZVA8 Dynamic range at optional measurement input (direct generator/receiver access option) of the Dynamic range at optional measurement input (direct generator/receiver access option) of the Dynamic range at optional measurement input (direct generator/receiver access option) of the Dynamic range at optional measurement input (direct generator/receiver access option) of the from PORT to MEAS 2 IN 3 khz to MHz typ. > 25 db MHz to MHz typ. > 35 db MHz to 8 GHz typ. > 45 db from PORT to MEAS 2 IN MHz to MHz typ. > 35 db MHz to 3 GHz typ. > 45 db 3 GHz to 2 GHz typ. > 4 db 2 GHz to 24 GHz typ. > 3 db from PORT to MEAS 2 IN MHz to MHz typ. > 4 db MHz to 2 GHz typ. > 5 db 2 GHz to 24 GHz typ. > 4 db 24 GHz to 32 GHz typ. > 3 db 32 GHz to 4 GHz typ. > 2 db from PORT to MEAS 2 IN MHz to MHz typ. > 4 db MHz to 2 GHz typ. > 5 db 2 GHz to 24 GHz typ. > 45 db 24 GHz to 32 GHz typ. > 4 db 32 GHz to 4 GHz typ. > 35 db 4 GHz to 5 GHz typ. > 3 db from PORT to MEAS 2 IN MHz to MHz typ. > 4 db MHz to 2 GHz typ. > 45 db 2 GHz to 24 GHz typ. > 45 db 24 GHz to 32 GHz typ. > 4 db 32 GHz to 4 GHz typ. > 35 db 4 GHz to 5 GHz typ. > 3 db 5 GHz to 67 GHz typ. > 25 db Rohde & Schwarz R&S ZVA Vector Network Analyzer 5

Diagram: Dynamic range in db versus frequency in GHz of the R&S ZVA8. Diagram: Dynamic range in db versus frequency in GHz of the. Diagram: Dynamic range in db versus frequency in GHz of the. 6 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Diagram: Dynamic range in db versus frequency in GHz of the. Diagram: Dynamic range in db versus frequency in GHz of the. Rohde & Schwarz R&S ZVA Vector Network Analyzer 7

Measurement speed Measurement time per point CW mode, < 3.5 µs MHz measurement bandwidth Data transfer time for 2 measurements points via IEC/IEEE bus < 2.9 ms via VX over Mbit/s LAN <.3 ms via RSIB over Mbit/s LAN <.7 ms Switching time between channels with no more than 2 points < ms Switching time between two preloaded instrument settings with no more than 2 points < ms Sweep times of the R&S ZVA8,, and Sweep times depend on the number of measurement points, the measurement bandwidth, and the start and stop frequencies. They include times for retrace and internal band switching and are valid with ALC and display switched off. Number of measurement points 5 2 4 8 6 R&S ZVA with start frequency 5 GHz, stop frequency 5.2 GHz For a measurement bandwidth of khz With full one-port calibration or with correction switched off 2.6 ms 4. ms 6.8 ms 2 ms 23 ms 42 ms With TOSM calibration 3.8 ms 6.5 ms.6 ms 22 ms 4 ms 24 ms For a measurement bandwidth of MHz With full one-port calibration or with correction switched off 2. ms 3. ms 4.7 ms 8. ms 5 ms 26 ms With TOSM calibration 2.8 ms 4.5 ms 7.5 ms 4 ms 26 ms 94 ms R&S ZVA with start frequency 6 GHz, stop frequency 8 GHz For a measurement bandwidth of khz With full one-port calibration or with correction switched off 3.6 ms 6.4 ms.5 ms 9 ms 3 ms 5 ms With TOSM calibration 4.8 ms 8.9 ms 6.3 ms 29 ms 49 ms 32 ms For a measurement bandwidth of MHz With full one-port calibration or with correction switched off 3. ms 5.4 ms 9.4 ms 4.7 ms 23 ms 35 ms With TOSM calibration 3.8 ms 6.8 ms 2.2 ms 2.5 ms 33 ms 3 ms R&S ZVA8 with start frequency MHz and stop frequency 8 GHz with start frequency MHz and stop frequency 24 GHz with start frequency MHz and stop frequency 4 GHz with start frequency MHz and stop frequency 5 GHz For a measurement bandwidth of khz With full one-port calibration or with correction switched off 8.6 ms 3 ms 9.4 ms 32 ms 55 ms 92 ms With TOSM calibration 9.9 ms 5.5 ms 25 ms 4 ms 74 ms 73 ms For a measurement bandwidth of MHz With full one-port calibration or with correction switched off 8.2 ms 2 ms 7.4 ms 28 ms 47 ms 75 ms With TOSM calibration 8.8 ms 3.4 ms 2.2 ms 33 ms 57 ms 43 ms 8 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Sweep times of the Sweep times depend on the number of measurement points, the measurement bandwidth, and the start and stop frequencies. They include times for retrace and internal band switching and are valid with ALC and display switched off. Number of measurement points 5 2 4 8 6 with start frequency 6 GHz, stop frequency 2 GHz For a measurement bandwidth of khz With full one-port calibration or with correction switched off 2 ms 3 ms 6 ms ms 2 ms 42 ms With TOSM calibration 4 ms 6 ms 2 ms 22 ms 42 ms 25 ms For a measurement bandwidth of MHz With full one-port calibration or with correction switched off.5 ms 2 ms 4 ms 7 ms 3 ms 25 ms With TOSM calibration 3 ms 4 ms 8 ms 4 ms 26 ms 9 ms with start frequency MHz and stop frequency 67 GHz For a measurement bandwidth of khz With full one-port calibration or with correction switched off 3 ms 4 ms 7 ms 2 ms 22 ms 42 ms With TOSM calibration 6 ms 8 ms 4 ms 24 ms 44 ms 25 ms For a measurement bandwidth of MHz With full one-port calibration or with correction switched off 2.5 ms 3 ms 5 ms 8 ms 4 ms 25 ms With TOSM calibration 5 ms 6 ms ms 6 ms 28 ms 9 ms Rohde & Schwarz R&S ZVA Vector Network Analyzer 9

Measurement accuracy This data is valid between +8 C and +28 C, provided the temperature has not varied by more than K after calibration. Validity of the data is conditional on the use of a suitable calibration kit. This calibration kit is used to achieve the effective system data specified below. Frequency points, measurement bandwidth, and sweep time have to be identical for measurement and calibration (no interpolation allowed). Accuracy of transmission measurements R&S ZVA8 3 khz to MHz for +5 db to 45 db < db or < 6 MHz to 5 MHz for +5 db to 3 db <.2 db or < 2 for 3 db to 45 db < db or < 6 5 MHz to 8 GHz for +5 db to +5 db <.2 db or < 2 for +5 db to 55 db <. db or < for 55 db to 7 db <.2 db or < 2 for 7 db to 85 db < db or < 6 MHz to 5 MHz for +5 db to 3 db < db or < 6 5 MHz to 4 MHz for +5 db to 3 db <.2 db or < 2 for 3 db to 45 db < db or < 6 4 MHz to 7 MHz for +5 db to 5 db <.2 db or < 2 for 5 db to 65 db < db or < 6 7 MHz to 24 GHz for +5 db to +5 db <.2 db or < 2 for +5 db to 55 db <. db or < for 55 db to 7 db <.2 db or < 2 for 7 db to 85 db < db or < 6 MHz to 5 MHz for +5 db to 3 db < db or < 6 5 MHz to 25 MHz for +5 db to 3 db <.2 db or < 2 for 3 db to 45 db < db or < 6 25 MHz to 7 MHz for +5 db to +5 db <.3 db or < 3 for +5 db to 65 db <.2 db or < 2 for 65 db to 8 db < db or < 6 7 MHz to 2 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 5 db <. db or < for 5 db to 65 db <.2 db or < 2 for 65 db to 8 db < db or < 6 2 GHz to 24 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 55 db <. db or < for 55 db to 7 db <.2 db or < 2 for 7 db to 85 db < db or < 6 24 GHz to 32 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 45 db <.2 db or < 2 for 45 db to 6 db <.3 db or < 3 for 6 db to 75 db < db or < 6 32 GHz to 4 GHz for +5 db to +5 db <.4 db or < 4 for +5 db to 4 db <.2 db or < 2 for 4 db to 55 db <.4 db or < 4 for 55 db to 7 db < db or < 6 Rohde & Schwarz R&S ZVA Vector Network Analyzer

MHz to 5 MHz for +5 db to 3 db < db or < 6 5 MHz to 25 MHz for +5 db to 3 db <.2 db or < 2 for 3 db to 45 db < db or < 6 25 MHz to 7 MHz for +5 db to +5 db <.3 db or < 3 for +5 db to 65 db <.2 db or < 2 for 65 db to 8 db < db or < 6 7 MHz to 2 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 5 db <. db or < for 5 db to 65 db <.2 db or < 2 for 65 db to 8 db < db or < 6 2 GHz to 24 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 55 db <. db or < for 55 db to 7 db <.2 db or < 2 for 7 db to 85 db < db or < 6 24 GHz to 32 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 45 db <.2 db or < 2 for 45 db to 6 db <.3 db or < 3 for 6 db to 75 db < db or < 6 32 GHz to 4 GHz for +5 db to +5 db <.4 db or < 4 for +5 db to 4 db <.2 db or < 2 for 4 db to 55 db <.4 db or < 4 for 55 db to 7 db < db or < 6 4 GHz to 5 GHz for +5 db to +5 db <.4 db or < 4 for +5 db to 35 db <.2 db or < 2 for 35 db to 5 db <.4 db or < 4 for 5 db to 65 db < db or < 6 Rohde & Schwarz R&S ZVA Vector Network Analyzer

MHz to 5 MHz for +5 db to 3 db < db or < 6 5 MHz to 25 MHz for +5 db to 3 db <.2 db or < 2 for 3 db to 45 db < db or < 6 25 MHz to 7 MHz for +5 db to +5 db <.3 db or < 3 for +5 db to 65 db <.2 db or < 2 for 65 db to 8 db < db or < 6 7 MHz to 2 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 5 db <. db or < for 5 db to 65 db <.2 db or < 2 for 65 db to 8 db < db or < 6 2 GHz to 24 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 55 db <. db or < for 55 db to 7 db <.2 db or < 2 for 7 db to 85 db < db or < 6 24 GHz to 32 GHz for +5 db to +5 db <.3 db or < 3 for +5 db to 45 db <.2 db or < 2 for 45 db to 6 db <.3 db or < 3 for 6 db to 75 db < db or < 6 32 GHz to 4 GHz for +5 db to +5 db <.4 db or < 4 for +5 db to 4 db <.2 db or < 2 for 4 db to 55 db <.4 db or < 4 for 55 db to 7 db < db or < 6 4 GHz to 5 GHz for +5 db to +5 db <.4 db or < 4 for +5 db to 35 db <.2 db or < 2 for 35 db to 5 db <.4 db or < 4 for 5 db to 65 db < db or < 6 5 GHz to 67 GHz for +5 db to +5 db <.4 db or < 4 for +5 db to 3 db <.2 db or < 2 for 3 db to 45 db <.4 db or < 4 for 45 db to 6 db < db or < 6 Specifications are based on a matched DUT, a measurement bandwidth of Hz, and a nominal source power of dbm. Trace stability Trace noise of S (RMS) at dbm source power, db reflection, and khz measurement bandwidth R&S ZVA8 3 khz to 8 GHz <.4 db, typ.. db 7 MHz to 24 GHz <.4 db, typ.. db 7 MHz to 24 GHz <.4 db, typ.. db 24 GHz to 4 GHz <.5 db, typ..4 db 7 MHz to 24 GHz <.4 db, typ.. db 24 GHz to 5 GHz <.5 db, typ..4 db 7 MHz to 24 GHz <.4 db, typ.. db 24 GHz to 48 GHz <.5 db, typ..4 db 48 GHz to 67 GHz <.3 db, typ.. db Temperature dependence at db transmission or reflection up to 24 GHz <.5 db/k or <.4 /K 24 GHz to 67 GHz <. db/k or < /K 2 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Magnitude Phase Uncertainty / db,, -2-4 -6-8 - Uncertainty / deg. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA8 in the frequency range 3 khz to 5 MHz. Magnitude Phase Uncertainty / db. Uncertainty / deg. -2-4 -6-8 -. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the R&S ZVA8 in the frequency range 5 MHz to 8 GHz. Rohde & Schwarz R&S ZVA Vector Network Analyzer 3

Magnitude Phase Uncertainty / db. Uncertainty / deg. -2-4 -6-8 -. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the in the frequency range MHz to 7 MHz. Magnitude Phase Uncertainty / db. Uncertainty / deg. -2-4 -6-8 -. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the in the frequency range 7 MHz to 24 GHz. 4 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Magnitude Phase Uncertainty / db. Uncertainty / deg. -2-4 -6-8 -. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the in the frequency range MHz to 7 MHz. Magnitude Phase Uncertainty / db.. -2-4 -6-8 - Uncertainty / deg. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the in the frequency range 7 MHz to 24 GHz. Magnitude Phase Uncertainty / db.. -2-4 -6-8 - Uncertainty / deg. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the in the frequency range 24 GHz to 4 GHz. Rohde & Schwarz R&S ZVA Vector Network Analyzer 5

Magnitude Phase Uncertainty / db. Uncertainty / deg. -2-4 -6-8 -. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the and in the frequency range MHz to 7 MHz. Magnitude Phase Uncertainty / db.. -2-4 -6-8 - Uncertainty / deg. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the and in the frequency range 7 MHz to 24 GHz. Magnitude Phase Uncertainty / db.. -2-4 -6-8 - Uncertainty / deg. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the and in the frequency range 24 GHz to 5 GHz. 6 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Magnitude Phase Uncertainty / db. Uncertainty / deg. -2-4 -6-8 -. -2-4 -6-8 - Diagram: Typical accuracy of transmission magnitude and transmission phase measurements of the in the frequency range 5 GHz to 67 GHz. Rohde & Schwarz R&S ZVA Vector Network Analyzer 7

Accuracy of reflection measurements R&S ZVA8 3 khz to MHz for + db to 25 db < db or < 6 for 25 db to 35 db < 3 db or < 2 MHz to 8 GHz for + db to +3 db <.6 db or < 4 for +3 db to 5 db <.4 db or < 3 for 5 db to 25 db < db or < 6 for 25 db to 35 db < 3 db or < 2 MHz to 5 MHz for +3 db to 5 db < db or < 6 for 5 db to 25 db < 3 db or < 2 5 MHz to 24 GHz for + db to +3 db <.6 db or < 4 for +3 db to 5 db <.4 db or < 3 for 5 db to 25 db < db or < 6 for 25 db to 35 db < 3 db or < 2 MHz to 5 MHz for +3 db to 5 db < db or < 6 for 5 db to 25 db < 3 db or < 2 5 MHz to 4 GHz for + db to +3 db <.6 db or < 4 for +3 db to 5 db <.4 db or < 3 for 5 db to 25 db < db or < 6 for 25 db to 35 db < 3 db or < 2 MHz to 5 MHz for +3 db to 5 db < db or < 6 for 5 db to 25 db < 3 db or < 2 5 MHz to 5 GHz for + db to +3 db <.6 db or < 4 for +3 db to 5 db <.4 db or < 3 for 5 db to 25 db < db or < 6 for 25 db to 35 db < 3 db or < 2 MHz to 5 MHz for +3 db to 5 db < db or < 6 for 5 db to 25 db < 3 db or < 2 5 MHz to 67 GHz for + db to +3 db <.6 db or < 4 for +3 db to 5 db <.4 db or < 3 for 5 db to 25 db < db or < 6 for 25 db to 35 db < 3 db or < 2 Specifications are based on an isolating DUT, a measurement bandwidth of Hz, and a nominal source power of dbm. Magnitude Phase Uncertainty (linear).5.4.3.2...2.4.6.8 Uncertainty / deg 8 6 4 2.2.4.6.8 Reflection coefficient (linear) Reflection coefficient (linear) Diagram: Typical accuracy of reflection magnitude and reflection phase measurements of the R&S ZVA8 in the frequency range MHz to 8 GHz, of the in the frequency range 5 MHz to 24 GHz, of the in the frequency range 5 MHz to 4 GHz, of the in the frequency range 5 MHz to 5 GHz, and of the in the frequency range 5 MHz to 67 GHz. 8 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Effective system data This data is valid between +8 C and +28 C, provided the temperature has not varied by more than K after calibration. The data is based on a measurement bandwidth of Hz and system error calibration by means of the mentioned calibration kit. Frequency points, measurement bandwidth, and sweep time have to be identical for measurement and calibration (no interpolation allowed). R&S ZVA8 and R&S ZV-Z27 Directivity MHz to 7 MHz > 36 db, typ. 46 db 7 MHz to 8 GHz > 4 db, typ. 46 db Source match MHz to 7 MHz > 3 db, typ. 43 db 7 MHz to 8 GHz > 36 db, typ. 43 db Reflection tracking MHz to 7 MHz <.2 db, typ..4 db 7 MHz to 8 GHz <. db, typ..2 db Load match MHz to 7 MHz > 36 db, typ. 46 db 7 MHz to 8 GHz > 4 db, typ. 46 db Transmission tracking MHz to 7 MHz <.2 db, typ..4 db 7 MHz to 8 GHz <. db, typ..2 db and R&S ZV-Z235 Directivity MHz to 7 MHz > 36 db, typ. 46 db 7 MHz to 24 GHz > 4 db, typ. 46 db Source match MHz to 7 MHz > 3 db, typ. 43 db 7 MHz to 24 GHz > 36 db, typ. 43 db Reflection tracking MHz to 7 MHz <.2 db, typ..4 db 7 MHz to 24 GHz <. db, typ..2 db Load match MHz to 7 MHz > 36 db, typ. 46 db 7 MHz to 24 GHz > 4 db, typ. 46 db Transmission tracking MHz to 7 MHz <.2 db, typ..4 db 7 MHz to 24 GHz <. db, typ..2 db and R&S ZV-Z229 Directivity MHz to 7 MHz > 33 db, typ. 36 db 7 MHz to 24 GHz > 38 db, typ. 42 db 24 GHz to 4 GHz > 33 db, typ. 36 db Source match MHz to 7 MHz > 3 db, typ. 36 db 7 MHz to 24 GHz > 36 db, typ. 4 db 24 GHz to 4 GHz > 3 db, typ. 36 db Reflection tracking MHz to 7 MHz <.2 db, typ.. db 7 MHz to 24 GHz <. db, typ..5 db 24 GHz to 4 GHz <.2 db, typ.. db Load match MHz to 7 MHz > 33 db, typ. 36 db 7 MHz to 24 GHz > 38 db, typ. 42 db 24 GHz to 4 GHz > 33 db, typ. 36 db Transmission tracking MHz to 7 MHz <.2 db, typ.. db 7 MHz to 24 GHz <. db, typ..4 db 24 GHz to 4 GHz <.2 db, typ..8 db and R&S ZV-Z224 Directivity MHz to 7 MHz > 33 db, typ. 4 db 7 MHz to 24 GHz > 4 db, typ. 46 db 24 GHz to 5 GHz > 33 db, typ. 36 db Source match MHz to 7 MHz > 3 db, typ. 4 db 7 MHz to 24 GHz > 36 db, typ. 4 db 24 GHz to 5 GHz > 3 db, typ. 36 db Reflection tracking MHz to 7 MHz <.2 db, typ.. db 7 MHz to 24 GHz <. db, typ..5 db 24 GHz to 5 GHz <.2 db, typ.. db Load match MHz to 7 MHz > 33 db, typ. 4 db 7 MHz to 24 GHz > 38 db, typ. 42 db 24 GHz to 5 GHz > 33 db, typ. 36 db Transmission tracking MHz to 7 MHz <.2 db, typ.. db 7 MHz to 24 GHz <. db, typ..5 db 24 GHz to 5 GHz <.2 db, typ.. db Rohde & Schwarz R&S ZVA Vector Network Analyzer 9

and R&S ZV-Z28 Directivity MHz to 7 MHz > 3 db, typ. 36 db 7 MHz to 24 GHz > 36 db, typ. 42 db 24 GHz to 67 GHz > 32 db, typ. 38 db Source match MHz to 7 MHz > 3 db, typ. 36 db 7 MHz to 24 GHz > 36 db, typ. 42 db 24 GHz to 67 GHz > 3 db, typ. 36 db Reflection tracking MHz to 7 MHz <.2 db, typ.. db 7 MHz to 24 GHz <. db, typ..5 db 24 GHz to 67 GHz <.2 db, typ.. db Load match MHz to 7 MHz > 3 db, typ. 36 db 7 MHz to 24 GHz > 36 db, typ. 42 db 24 GHz to 67 GHz > 3 db, typ. 36 db Transmission tracking MHz to 7 MHz <.2 db, typ.. db 7 MHz to 24 GHz <. db, typ..5 db 24 GHz to 67 GHz <.2 db, typ.. db 2 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Test port output Power range (without optional step attenuators and without optional direct generator/receiver access) Power accuracy (with ALC on; without power calibration) R&S ZVA8 3 khz to 5 MHz 4 dbm to + dbm, typ. 45 dbm to +4 dbm 5 MHz to 4 GHz 4 dbm to +3 dbm, typ. 45 dbm to +5 dbm 4 GHz to 7 GHz 4 dbm to + dbm, typ. 45 dbm to +3 dbm 7 GHz to 8 GHz 4 dbm to +8 dbm, typ. 45 dbm to +2 dbm MHz to 3 GHz 3 dbm to +3 dbm, typ. 4 dbm to +8 dbm 3 GHz to 24 GHz 3 dbm to + dbm, typ. 4 dbm to +6 dbm MHz to 5 MHz 3 dbm to + dbm, typ. 4 dbm to +5 dbm 5 MHz to 2 GHz 3 dbm to +3 dbm, typ. 4 dbm to +8 dbm 2 GHz to 32 GHz 3 dbm to + dbm, typ. 4 dbm to +5 dbm 32 GHz to 4 GHz 3 dbm to +9 dbm, typ. 4 dbm to +2 dbm MHz to 5 MHz 3 dbm to + dbm, typ. 4 dbm to +5 dbm 5 MHz to 2 GHz 3 dbm to +3 dbm, typ. 4 dbm to +8 dbm 2 GHz to 35 GHz 3 dbm to +2 dbm, typ. 4 dbm to +5 dbm 35 GHz to 5 GHz 3 dbm to + dbm, typ. 4 dbm to +2 dbm MHz to 5 MHz 3 dbm to + dbm, typ. 4 dbm to +5 dbm 5 MHz to 2 GHz 3 dbm to +3 dbm, typ. 4 dbm to +8 dbm 2 GHz to 32 GHz 3 dbm to + dbm, typ. 4 dbm to +5 dbm 32 GHz to 5 GHz 3 dbm to +8 dbm, typ. 4 dbm to +2 dbm 5 GHz to 6 GHz 3 dbm to +5 dbm, typ. 4 dbm to +6 dbm 6 GHz to 64 GHz 3 dbm to +4 dbm, typ. 4 dbm to +6 dbm 64 GHz to 67 GHz 3 dbm to +2 dbm, typ. 4 dbm to +6 dbm 67 GHz to 7 GHz typ. 3 to +2 dbm R&S ZVA8 at dbm < 2 db in temperature range +8 C to +28 C 5 MHz to 8 GHz <.8 db, typ..3 db at dbm < 3 db in temperature range +8 C to +28 C 5 MHz to 24 GHz <.8 db, typ..3 db at dbm < 3 db in temperature range +8 C to +28 C 5 MHz to 24 GHz <.8 db, typ..3 db 24 GHz to 4 GHz < 2 db, typ..8 db at dbm < 3 db in temperature range +8 C to +28 C 5 MHz to 24 GHz 24 GHz to 5 GHz <.8 db, typ..3 db < 2 db, typ..8 db Rohde & Schwarz R&S ZVA Vector Network Analyzer 2

Power linearity in temperature range +8 C to +28 C (with ALC on; without power calibration) Power resolution Harmonics (output power referenced to maximum specified output power) at dbm in temperature range +8 C to +28 C 5 MHz to 24 GHz 24 GHz to 67 GHz referenced to dbm above 5 MHz R&S ZVA8 above 5 MHz above 5 MHz above 5 MHz above 5 MHz above 5 MHz < 3 db <.8 db, typ..3 db < 2 db, typ. db < 2 db <.8 db, typ..3 db <.8 db, typ..3 db <.8 db, typ..3 db <.8 db, typ..3 db <.8 db, typ..3 db. db R&S ZVA8 3 khz to 5 MHz at 3 db typ. < 3 dbc 5 MHz to 4 GHz at 5 db < 2 dbc, typ. < 3 dbc 4 GHz to 7 GHz at 2 db < 2 dbc, typ. < 3 dbc 7 GHz to 8 GHz at db < 2 dbc, typ. < 3 dbc MHz to 5 MHz at 3 db typ. < 3 dbc 5 MHz to 3 GHz at 3 db < 2 dbc, typ. < 3 dbc 3 GHz to 24 GHz at db < 2 dbc, typ. < 3 dbc MHz to 5 MHz at 3 db typ. < 3 dbc 5 MHz to 2 GHz at 3 db < 2 dbc, typ. < 3 dbc 2 GHz to 4 GHz at db < 2 dbc, typ. < 3 dbc MHz to 5 MHz at 3 db typ. < 3 dbc 5 MHz to 2 GHz at 3 db < 2 dbc, typ. < 3 dbc 2 GHz to 5 GHz at 5 db < 2 dbc, typ. < 3 dbc MHz to 5 MHz at 3 db typ. < 2 dbc 5 MHz to 5 GHz at 3 db < 5 dbc, typ. < 25 dbc 5 GHz to 67 GHz at 3 db < 2 dbc, typ. < 3 dbc Diagram: Maximum output power in dbm versus frequency in GHz of the R&S ZVA8. Diagram: Maximum output power in dbm versus frequency in GHz of the. 22 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Diagram: Maximum output power in dbm versus frequency in GHz of the. Diagram: Maximum output power in dbm versus frequency in GHz of the. Diagram: Maximum output power in dbm versus frequency in GHz of the. Diagram: Output power accuracy in db versus frequency in GHz of the R&S ZVA8. Rohde & Schwarz R&S ZVA Vector Network Analyzer 23

Diagram: Output power accuracy in db versus frequency in GHz of the. Diagram: Output power accuracy in db versus frequency in GHz of the. Diagram: Output power accuracy in db versus frequency in GHz of the. Diagram: Output power accuracy in db versus frequency in GHz of the. 24 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Test port input Match Maximum nominal input level without system error correction R&S ZVA8 3 khz to 7 GHz > 6 db 7 GHz to 8 GHz > 4 db MHz to 5 MHz > db 5 MHz to 2 GHz > 2 db 2 GHz to 24 GHz > 8 db MHz to 4 GHz > 2 db 4 GHz to 2 GHz > 8 db 2 GHz to 4 GHz > 6 db MHz to 5 MHz > 8 db 5 MHz to GHz > db GHz to 2 GHz > 8 db 2 GHz to 4 GHz > 6 db 4 GHz to 5 GHz > 5 db MHz to 5 MHz > 8 db 5 MHz to GHz > db GHz to 2 GHz > 9 db 2 GHz to 4 GHz > 8 db 4 GHz to 67 GHz > 6 db R&S ZVA8 3 khz to 8 GHz +3 dbm MHz to 3 GHz +5 dbm 3 GHz to 24 GHz + dbm MHz to 3 GHz + dbm 3 GHz to 24 GHz +6 dbm 24 GHz to 4 GHz +3 dbm MHz to 3 GHz + dbm 3 GHz to 24 GHz +6 dbm 24 GHz to 5 GHz +3 dbm MHz to 3 GHz + dbm 3 GHz to 24 GHz +6 dbm 24 GHz to 67 GHz +3 dbm Rohde & Schwarz R&S ZVA Vector Network Analyzer 25

Power measurement accuracy at dbm without power calibration in temperature range +8 C to +28 C R&S ZVA8 MHz to 8 GHz < db MHz to 3 GHz < db 3 GHz to 24 GHz < 2 db MHz to 5 MHz < 2 db 5 MHz to 3 GHz < db 3 GHz to 24 GHz < 2 db 24 GHz to 4 GHz < 3 db MHz to 5 MHz < 2 db 5 MHz to 3 GHz < db 3 GHz to 24 GHz < 2 db 24 GHz to 5 GHz < 3 db MHz to 5 MHz < 2 db 5 MHz to 3 GHz < db 3 GHz to 24 GHz < 2 db 24 GHz to 5 GHz < 3 db 5 GHz to 67 GHz < 4 db 26 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Receiver linearity referenced to dbm in temperature range +8 C to +28 C R&S ZVA8 for +2 db to 6 db 5 MHz to 8 GHz <. db for 6 db to 85 db 5 MHz to 8 GHz typ. <. db for +2 db to 3 db 5 MHz to 7 MHz <. db for 3 db to 5 db 5 MHz to 7 MHz typ. <. db for +2 db to + db 7 MHz to 24 GHz <.3 db for + db to 45 db 7 MHz to 24 GHz <. db for 45 db to 8 db 7 MHz to 24 GHz typ. <. db for +2 db to 3 db 5 MHz to 25 MHz <. db for 3 db to 5 db 5 MHz to 25 MHz typ. <. db for + db to +5 db 25 MHz to 4 GHz <.3 db for +5 db to 45 db 25 MHz to 4 GHz <. db for 45 db to 65 db 25 MHz to 4 GHz typ. <. db for +2 db to 3 db 5 MHz to 25 MHz <. db for 3 db to 5 db 5 MHz to 25 MHz typ. <. db for + db to +5 db 25 MHz to 5 GHz <.3 db for +5 db to 45 db 25 MHz to 5 GHz <. db for 45 db to 65 db 25 MHz to 5 GHz typ. <. db for +5 db to 3 db 5 MHz to 25 MHz <. db for 3 db to 5 db 5 MHz to 25 MHz typ. <. db for + db to +5 db 25 MHz to 67 GHz <.3 db for +5 db to 45 db 25 MHz to 67 GHz <. db for 45 db to 6 db 25 MHz to 67 GHz typ. <. db Damage level +27 dbm Damage DC voltage 3 V Rohde & Schwarz R&S ZVA Vector Network Analyzer 27

Noise level (without optional step attenuators and without optional direct generator/receiver access) Noise level at optional measurement input (direct generator/receiver access option) at Hz measurement bandwidth R&S ZVA8 3 khz to MHz < dbm MHz to 8 GHz < 5 dbm MHz to MHz typ. < 8 dbm MHz to 7 MHz < 8 dbm 7 MHz to 2 GHz < dbm 2 GHz to 3 GHz < 5 dbm 3 GHz to 24 GHz < dbm MHz to MHz typ. < 8 dbm MHz to 5 MHz < 8 dbm 5 MHz to 2 GHz < dbm 2 GHz to 2 GHz < 5 dbm 2 GHz to 24 GHz < dbm 24 GHz to 32 GHz < 5 dbm 32 GHz to 4 GHz < dbm MHz to MHz typ. < 8 dbm MHz to 5 MHz < dbm 5 MHz to 24 GHz < 5 dbm 24 GHz to 4 GHz < dbm 4 GHz to 5 GHz < dbm MHz to MHz typ. < 8 dbm MHz to 5 MHz < 5 dbm 5 MHz to 2 GHz < dbm 2 GHz to 24 GHz < 8 dbm 24 GHz to 4 GHz < 5 dbm 4 GHz to 5 GHz < 2 dbm 5 GHz to 67 GHz < dbm at Hz measurement bandwidth R&S ZVA8 MHz to 8 GHz typ. < 3 dbm MHz to 24 GHz typ. < 3 dbm MHz to 24 GHz typ. < 3 dbm 24 GHz to 4 GHz typ. < 2 dbm MHz to 24 GHz typ. < 3 dbm 24 GHz to 4 GHz typ. < 2 dbm 4 GHz to 5 GHz typ. < 5 dbm MHz to 24 GHz typ. < 3 dbm 24 GHz to 4 GHz typ. < 2 dbm 4 GHz to 5 GHz typ. < 5 dbm 5 GHz to 67 GHz typ. < dbm The noise level is defined as the RMS value of the indicated noise floor. For the at single frequencies below 2.5 GHz, the noise level may be affected by spurious signals. 28 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Additional front panel connectors USB (two) universal serial bus connectors for connecting USB devices (USB 2.); two additional USB connectors at the rear panel Optional front panel connectors SOURCE OUT SOURCE IN REF OUT REF IN MEAS OUT MEAS IN output of internal source signal input for external source signal output of internal reference signal input for external reference signal output of internal measurement signal input for external measurement signal Display Screen Resolution Rear panel connectors IEC BUS 26 cm (.4") diagonal color LCD 8 6 26244 pixels (high color) remote control in line with IEEE 488, IEC 6625; 24 pins LAN first local area network connector, 8 pins, RJ-45 LAN 2 second local area network connector, 8 pins, RJ-45 USB (two) universal serial bus connectors for connecting USB devices (USB 2.); two additional USB connectors at the front panel MHz REF alternatively input or output for external frequency reference signal Connector type BNC, female Input frequency MHz Maximum permissible deviation khz Input power 5 dbm to + dbm Input impedance 5 Ω Output frequency MHz Output frequency accuracy 8 Hz Output power 5 dbm to + dbm at 5 Ω Rohde & Schwarz R&S ZVA Vector Network Analyzer 29

DC MEAS V Connector type Voltage range Measurement accuracy Resolution Bandwidth Input impedance Damage voltage DC measurement input 4-pin mini DIN, female V to + V 2.5 % of reading + 2.5 mv 2 bit < khz > kω 3 V DC MEAS V Connector type Voltage range Measurement accuracy Resolution Bandwidth Input impedance Damage voltage DC measurement input 4-pin mini DIN, female V to + V 2.5 % of reading + 25 mv 2 bit < khz > kω 3 V PORT BIAS Connector type Maximum nominal input voltage Maximum nominal input current Damage voltage Damage current DC bias input for PORT BNC, female 3 V 2 ma 3 V 5 ma MONITOR IBM-PC-compatible VGA monitor connector, 5-pin D-Sub (for external monitor) USER CONTROL several control and trigger signals, 25-pin D-Sub, 3.3 V TTL for controlling external generators, for limit checks, sweep signals, etc. FOOT SWITCH and FOOT SWITCH 2 pin 24 and pin 25 (inputs) control inputs DRIVE PORT to DRIVE PORT 4 pin 6 to pin 9 (outputs) indicate driving port CHANNEL BIT to CHANNEL BIT 3 pin 8 to pin (outputs) channel-specific user-configurable bits PASS and PASS 2 pin 3 and pin 4 (outputs) pass/fail results of limit checks BUSY pin 4 (output) measurements running READY FOR TRIGGER pin 6 (output) ready for trigger EXT GEN TRIGGER pin 2 (output) control signal for external generator EXT GEN BLANK pin 22 (input) handshake signal from external generator EXTERNAL TRIGGER pin 2 (input) trigger input for analyzer EXT TRIGGER trigger input for analyzer Connector type BNC, female TTL signal (edge-triggered) 3 V Polarity (user-selectable) positive or negative Minimum pulse width µs Input impedance > kω 3 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Options Generator step attenuators R&S ZVA8,, and : Generator step attenuators extend the lower limit of the output power range by 7 db. and : Generator step attenuators extend the lower limit of the output power range by 5 db. Frequency range R&S ZVA8 3 khz to 8 GHz MHz to 24 GHz MHz to 4 GHz MHz to 5 GHz MHz to 67 GHz Power range R&S ZVA8 3 khz to 8 GHz upper limit is reduced by db 3 khz to 8 GHz lower limit is extended by 7 db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db MHz to 24 GHz lower limit is extended by 7 db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db 24 GHz to 4 GHz upper limit is reduced by 3 db MHz to 4 GHz lower limit is extended by 7 db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db 24 GHz to 5 GHz upper limit is reduced by 3 db MHz to 5 GHz lower limit is extended by 5 db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db 24 GHz to 67 GHz upper limit is reduced by 3 db MHz to 67 GHz lower limit is extended by 5 db Power accuracy at dbm without power calibration identical to specifications without optional step attenuators Power linearity (with ALC off) R&S ZVA8,, and above 7 dbm < 2 db from 7 dbm to dbm < 3 db and above 5 dbm < 2 db from 5 dbm to 8 dbm < 3 db Dynamic range R&S ZVA8 3 khz to 8 GHz is reduced by db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db 24 GHz to 4 GHz is reduced by 3 db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db 24 GHz to 5 GHz is reduced by 3 db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db 24 GHz to 67 GHz is reduced by 3 db Rohde & Schwarz R&S ZVA Vector Network Analyzer 3

Receiver step attenuators These attenuators permit the input signal level to be attenuated in 5 db steps up to 35 db. Frequency range R&S ZVA8 3 khz to 8 GHz MHz to 24 GHz MHz to 4 GHz MHz to 5 GHz MHz to 67 GHz Attenuation db to 35 db Attenuation steps 5 db Attenuation accuracy < 2 db Dynamic range R&S ZVA8 3 khz to 8 GHz is reduced by db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db 24 GHz to 4 GHz is reduced by 3 db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db 24 GHz to 5 GHz is reduced by 3 db MHz to 3 GHz is reduced by db 3 GHz to 24 GHz is reduced by 2 db 24 GHz to 67 GHz is reduced by 3 db Noise level R&S ZVA8 3 khz to 8 GHz is increased by db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db 24 GHz to 4 GHz is increased by 3 db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db 24 GHz to 5 GHz is increased by 3 db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db 24 GHz to 67 GHz is increased by 3 db 32 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Direct generator/receiver access These options permit direct access to the internal source output as well as to the internal reference and measurement receiver inputs via front panel connectors. Dynamic range with direct access utilizing these inputs is stated in the Measurement range section. If all front panel jumper cables are directly connected between the outputs and inputs, the following vector network analyzer specifications apply. Front panel connectors R&S ZVA8 SMA, female 2.92 mm, female 2.92 mm, female.85 mm, female.85 mm, female Frequency range R&S ZVA8 3 khz to 8 GHz MHz to 24 GHz MHz to 4 GHz MHz to 5 GHz MHz to 67 GHz Dynamic range R&S ZVA8 3 khz to 8 GHz is reduced by 2 db MHz to 3 GHz is reduced by 2 db 3 GHz to 24 GHz is reduced by 4 db MHz to 3 GHz is reduced by 2 db 3 GHz to 24 GHz is reduced by 4 db 24 GHz to 4 GHz is reduced by 6 db MHz to 3 GHz is reduced by 2 db 3 GHz to 24 GHz is reduced by 4 db 24 GHz to 5 GHz is reduced by 6 db MHz to 3 GHz is reduced by 2 db 3 GHz to 24 GHz is reduced by 4 db 24 GHz to 67 GHz is reduced by 6 db Power range R&S ZVA8 3 khz to 8 GHz upper limit is reduced by db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db 24 GHz to 4 GHz upper limit is reduced by 3 db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db 24 GHz to 5 GHz upper limit is reduced by 3 db MHz to 3 GHz upper limit is reduced by db 3 GHz to 24 GHz upper limit is reduced by 2 db 24 GHz to 67 GHz upper limit is reduced by 3 db Match MHz to 4 GHz is reduced by 2 db Rohde & Schwarz R&S ZVA Vector Network Analyzer 33

Noise level R&S ZVA8 3 khz to 8 GHz is increased by db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db 24 GHz to 4 GHz is increased by 3 db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db 24 GHz to 5 GHz is increased by 3 db MHz to 3 GHz is increased by db 3 GHz to 24 GHz is increased by 2 db 24 GHz to 67 GHz is increased by 3 db Universal control interface I/O port several control and trigger signals, 36-pin Centronics connector, 3.3 V TTL for controlling external devices, limit checks, sweep signals, etc. Agilent handler interface compatibility type 3 Input signals pin 2, pin 8 3.3 V TTL, 5 V tolerant Output signals pin 3 to pin 7, pin 9 to pin 2, 3.3 V TTL, 5 V tolerant pin 3 to pin 34, pin 36 Input/output signals pin 22 to pin 29 3.3 V TTL, 5 V tolerant +5 V output pin 35 +5 V, max. ma Response time of write strobe signal pin 32 µs Pulse width of write strobe signal pin 32 µs Pulse width of external trigger signal pin 8 > µs Pulse width of sweep end signal pin 34 > µs 34 Rohde & Schwarz R&S ZVA Vector Network Analyzer

General data Temperature loading in line with IEC 668-2- and IEC 668-2-2 operating temperature range +5 C to +4 C permissible temperature range +5 C to +4 C storage temperature range 4 C to +7 C Damp heat +4 C at 95 % rel. humidity, in line with IEC 668-2-3 Mechanical resistance vibration, sinusoidal 5 Hz to 5 Hz, in line with IEC 668-2-6 vibration, random Hz to 3 Hz, in line with IEC 668-2-64 shock 4 g shock spectrum, in line with IEC 668-2-27, MIL-STD-8 Calibration interval year EMC, RF emission in line with EN 55 class A, operation is not covered in residential, commercial, and business areas nor in small-size companies. Thus, the instrument must not be operated in residential, commercial, and business areas nor in small-size companies unless additional measures are taken to ensure that EN 55 class B is met. in line with CISPR /EN 55 group class A (for a shielded test setup) The instrument complies with the emission requirements stipulated by EN 55 and EN 6326- class A. This means that the instrument is suitable for use in industrial environments. EMC, immunity in line with IEC/EN 6326-, immunity for industrial environments (excluding operating frequency) Safety in line with IEC 6-, EN 6-, and UL 3- Power supply V to 24 V (AC) with tolerance ± %, 5 Hz to 6 Hz with tolerance ±5 %, safety class I to VDE 4 Power consumption R&S ZVA8,,, 45 W, typ. 3 W (standby: typ. W) and only 65 W, typ. 45 W (standby: typ. W) Test mark VDE, GS, CSA, CSA-NRTL/C, CE conformity mark Dimensions (W H D) 465. mm 286.2 mm 495. mm (8.3 in.27 in 9.49 in) Weight 25 kg (55 lb) Shipping weight 37 kg (82 lb) Rohde & Schwarz R&S ZVA Vector Network Analyzer 35

Ordering information Designation Type Order No. Vector Network Analyzer, 8 GHz, two ports R&S ZVA8 45..8 Vector Network Analyzer, 8 GHz, four ports R&S ZVA8 45.. Vector Network Analyzer, 24 GHz, two ports 45..24 Vector Network Analyzer, 24 GHz, four ports 45..26 Vector Network Analyzer, 4 GHz, two ports, 2.92 mm 45..4 Vector Network Analyzer, 4 GHz, four ports, 2.92 mm 45..42 Vector Network Analyzer, 4 GHz, two ports, 2.4 mm 45..43 Vector Network Analyzer, 4 GHz, four ports, 2.4 mm 45..45 Vector Network Analyzer, 5 GHz, two ports 45..5 Vector Network Analyzer, 5 GHz, four ports 45..52 Vector Network Analyzer, 67 GHz, two ports 35.72.2 Vector Network Analyzer, 67 GHz, four ports 35.72.4 Options Direct Generator/Receiver Access for the R&S ZVA8 with two ports R&S ZVA8-B6 64.29.8 for the R&S ZVA8 with four ports R&S ZVA8-B6 64.29. for the with two ports -B6 64.29.24 for the with four ports -B6 64.29.26 for the with two ports -B6 64.29.4 for the with four ports -B6 64.29.42 for the with two ports -B6 64.29.5 for the with four ports -B6 64.29.52 for the with two ports -B6 64.29.67 for the with four ports -B6 64.29.69 Generator Step Attenuator Port for the R&S ZVA8 R&S ZVA8-B2 64.9.2 for the -B2 64.9.2 for the -B2 32.549.2 for the -B2 35.566.2 for the -B2 35.777.2 Generator Step Attenuator Port 2 for the R&S ZVA8 R&S ZVA8-B22 64.5.2 for the -B22 64.5.2 for the -B22 32.545.2 for the -B22 35.5622.2 for the -B22 35.783.2 Generator Step Attenuator Port 3 for the R&S ZVA8 with four ports R&S ZVA8-B23 64.2.2 for the with four ports -B23 64.2.2 for the with four ports -B23 32.542.2 for the with four ports -B23 35.5639.2 for the with four ports -B23 35.79.2 Generator Step Attenuator Port 4 for the R&S ZVA8 with four ports R&S ZVA8-B24 64.38.2 for the with four ports -B24 64.38.2 for the with four ports -B24 32.5438.2 for the with four ports -B24 35.5645.2 for the with four ports -B24 35.72.2 36 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Receiver Step Attenuator Port for the R&S ZVA8 R&S ZVA8-B3 64.44.2 for the -B3 64.44.2 for the -B3 32.5444.2 for the -B3 35.576.2 for the -B3 35.79.2 Receiver Step Attenuator Port 2 for the R&S ZVA8 R&S ZVA8-B32 64.5.2 for the -B32 64.5.2 for the -B32 32.545.2 for the -B32 35.5722.2 for the -B32 35.725.2 Receiver Step Attenuator Port 3 for the R&S ZVA8 with four ports R&S ZVA8-B33 64.67.2 for the with four ports -B33 64.67.2 for the with four ports -B33 32.5467.2 for the with four ports -B33 35.5739.2 for the with four ports -B33 35.73.2 Receiver Step Attenuator Port 4 for the R&S ZVA8 with four ports R&S ZVA8-B34 64.73.2 for the with four ports -B34 64.73.2 for the with four ports -B34 32.5473.2 for the with four ports -B34 35.5745.2 for the with four ports -B34 35.748.2 Oven Quartz (OCXO) R&S ZVAB-B4 64.757.2 External Attenuator Control for R&S ZVA-Z9E/-ZE R&S ZVA-B8 37.626.2 Cable Set for R&S ZVA-K9 (using R&S ZVA8) R&S ZVA-B9 3.334.2 Cable Set for R&S ZVA-K9 R&S ZVA-B9 3.334.3 (using or with 2.92 mm) Cable Set for R&S ZVA-K9 R&S ZVA-B9 3.334.4 (using with 2.4 mm,, or ) Universal Control Interface I/O Port R&S ZVAB-B4 35.636.2 Removable Flash Disc 4 GB (for R&S FMR6/5) R&S ZVAB-B8 64.75.2 Removable Flash Disc 4 GB (for R&S FMR7/3, R&S FMR7/6) R&S ZVAB-B8 64.75.3 Removable Hard Disc 6 GB (for R&S FMR7/3, R&S FMR7/6) R&S ZVAB-B8 64.75.4 Additional Removable Flash Disc 4 GB (for R&S FMR6/5) R&S ZVAB-B9 64..2 Additional Removable Flash Disc 4 GB (for R&S FMR7/3, R&S ZVAB-B9 64..3 R&S FMR7/6) Additional Removable Hard Disc 6 GB (for R&S FMR7/3, R&S ZVAB-B9 64..4 R&S FMR7/6) Time Domain R&S ZVAB-K2 64.657.2 Frequency Conversion R&S ZVA-K4 64.863.2 Mixer Phase Measurement R&S ZVA-K5 3.328.2 True Differential Mode R&S ZVA-K6 64.54.2 Pulsed Measurements Pulsed Measurements R&S ZVA-K7 64.5.2 Pulsed Measurements with increased recording time R&S ZVA-B7 64.492.2 for two-port models Pulsed Measurements with increased recording time R&S ZVA-B7 64.492.3 for four-port models Converter Control Software R&S ZVA-K8 37.722.2 Mixer Delay without LO Access R&S ZVA-K9 3.328.2 5 MHz Receiver Bandwidth R&S ZVA-K7 64.7.2 Internal Pulse Generators R&S ZVA-K27 64.892.2 Noise Figure Measurements R&S ZVA-K3 64.828.2 Rohde & Schwarz R&S ZVA Vector Network Analyzer 37

Service options Extended Warranty, one year R&S WEZVA Please contact your local Extended Warranty, two years R&S WE2ZVA Rohde & Schwarz sales office. Extended Warranty, three years R&S WE3ZVA Extended Warranty, four years R&S WE4ZVA Extended Warranty with Calibration Coverage, one year R&S CWZVA Extended Warranty with Calibration Coverage, two years R&S CW2ZVA Extended Warranty with Calibration Coverage, three years R&S CW3ZVA Extended Warranty with Calibration Coverage, four years R&S CW4ZVA Extended warranty with a term of one to four years (WE to WE4) Repairs carried out during the contract term are free of charge. Necessary calibration and adjustments carried out during repairs are also covered. Simply contact the forwarding agent we name; your product will be picked up free of charge and returned to you in top condition a couple of days later. Extended warranty with calibration (CW to CW4) Enhance your extended warranty by adding calibration coverage at a package price. This package ensures that your Rohde & Schwarz product is regularly calibrated, inspected and maintained during the term of the contract. It includes all repairs and calibration at the recommended intervals as well as any calibration carried out during repairs or option upgrades. For product brochure, see PD 523.568.2 and www.rohde-schwarz.com Excluding defects caused by incorrect operation or handling and force majeure. Wear-and-tear parts are not included. 38 Rohde & Schwarz R&S ZVA Vector Network Analyzer

Rohde & Schwarz R&S ZVA Vector Network Analyzer 39

Service you can rely on J Worldwide J Local and personalized J Customized and flexible J Uncompromising quality J Long-term dependability About Rohde & Schwarz Rohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established more than 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 7 countries. Company headquarters are in Munich, Germany. Environmental commitment Energy-efficient products Continuous improvement in environmental sustainability ISO 4-certified environmental management system Certified Quality System ISO 9 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 429 2345 customersupport@rohde-schwarz.com North America 888 TEST RSA ( 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America + 4 9 79 88 customersupport.la@rohde-schwarz.com Asia/Pacific +65 65 3 4 88 customersupport.asia@rohde-schwarz.com China +86 8 8 8228/+86 4 65 5896 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Printed in Germany (ch) PD 523.568.22 Version. May 22 R&S ZVA Subject to change 25-22 Rohde & Schwarz GmbH & Co. KG 867 München, Germany 52356822