GMES TERRAFIRMA. ESRIN/Contract no. 17059/03/I-IW. D2: Service Network Configuration Master Document. Version 1 February 28 th 2006.



Similar documents
Exploitation of historical satellite SAR archives for mapping and monitoring landslides at regional and local scale

Radar interferometric techniques and data validation Terrafirma Essen, March Page 1

Parallels Desktop 4 for Windows and Linux Read Me

AuditMatic Enterprise Edition Installation Specifications

Certification Document macle GmbH GRAFENTHAL R2208 S2 01/04/2016. macle GmbH GRAFENTHAL R2208 S2 Storage system

vrealize Business System Requirements Guide

FACILITIES AND EQUIPMENT

Certification Document macle GmbH Grafenthal-S1212M 24/02/2015. macle GmbH Grafenthal-S1212M Storage system

Very Large Enterprise Network, Deployment, Users

CONFIGURATION GUIDELINES: EMC STORAGE FOR PHYSICAL SECURITY

MedInformatix System Requirements

IT Business Management System Requirements Guide

System Requirements. SuccessMaker 5

Professional and Enterprise Edition. Hardware Requirements

Quest vworkspace Virtual Desktop Extensions for Linux

INFUSION BUSINESS SOFTWARE Installation and Upgrade Guide

Software and Hardware Requirements

The use of Satellite Remote Sensing for Offshore Environmental Benchmarking

Configuration Maximums VMware Infrastructure 3

alcatel-lucent vitalqip Appliance manager End-to-end, feature-rich, appliance-based DNS/DHCP and IP address management

Enabling Technologies for Distributed Computing

HP Intelligent Management Center Standard Software Platform

Very Large Enterprise Network Deployment, 25,000+ Users

WINNEBAGO COUNTY INFORMATION TECHNOLOGY STANDARDS 2014/2015

Project Overview. Kirk Beach Ohio Department of Transportation. ODOT Geotechnical Data Management System. Office of Geotechnical Engineering

Lytec 2014 Hardware and Software Requirements. Lytec Single-User Hardware and Software Requirements

Using advanced InSAR techniques as a remote tool for mine site monitoring

How do I Check if My Computer is Compatible with Windows 7

NEXTGEN v5.8 HARDWARE VERIFICATION GUIDE CLIENT HOSTED OR THIRD PARTY SERVERS

ACE Management Server Deployment Guide VMware ACE 2.0

African European Georesources Observation System

QuickSpecs. HP Session Allocation Manager Software (SAM v2.3) Overview

The Geohazards TEP Philippe Bally ESA, April 2015

GEOSPATIAL DIGITAL ASSET MANAGEMENT A SOLUTION INTEGRATING IMAGERY AND GIS WHERE WILL ALL THE PIXELS GO?(AND HOW WILL WE EVER FIND THEM?

Pan-European infrastructure for management of marine and ocean geological and geophysical data

Introduction of Huawei Backup Solution

Enabling Technologies for Distributed and Cloud Computing

Backup and Recovery. Backup and Recovery. Introduction. DeltaV Product Data Sheet. Best-in-class offering. Easy-to-use Backup and Recovery solution

Oracle Business Intelligence Enterprise Edition (OBIEE) Version with Quick Fix running on Oracle Enterprise Linux 4 update 5 x86_64

QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project

Molecular Devices High Content Data Management Solution Database Schema

Softline VIP Payroll System Requirements v2.9a January 2010

Cisco Prime Home 5.0 Minimum System Requirements (Standalone and High Availability)

Sage CRM Technical Specification

Deduplication on EonNAS Pro: UI Configurations and Impact on Capacity Utilization

Enterprise Edition. Hardware Requirements

STI Hardware Specifications for PCs

EO Information Services in support of Satellite Tools for Building Flood Defence Systems in Guyana

Data and Information Management for EO Data Centers. Eberhard Mikusch German Aerospace Center - German Remote Sensing Data Center

Monitoring a Changing Environment with Synthetic Aperture Radar. Alaska Satellite Facility National Park Service Don Atwood

Backup and Recovery. Introduction. Benefits. Best-in-class offering. Easy-to-use Backup and Recovery solution.

Rapattoni Magic 9 Hardware and Software Guidelines

Satellites for Terrain Motion Mapping Terrafirma User Workshop Mining. Nico Adam

Cisco WebEx Meetings Server System Requirements

Virtuoso and Database Scalability

Hardware Requirements

CA Nimsoft Monitor. snmpcollector Release Notes. All versions

IBM Rational Asset Manager

System Requirements. SAS Profitability Management Deployment

Wide Area Persistent Scatterer Interferometry: Algorithms and Examples

Data Information and Management System (DIMS) The New DIMS Hardware

icr3600 icr3600m VertX idr Film Digitizers Clarity PACS Innovative Medical Imaging

Parallel Processing using the LOTUS cluster

Cisco MCS 7825-H3 Unified Communications Manager Appliance

Intel Server Board S3420GPRX Intel Server System SR1630GPRX Intel Server System SR1630HGPRX

E-Business Technologies

Certification Document bluechip STORAGEline R54300s NAS-Server 03/06/2014. bluechip STORAGEline R54300s NAS-Server system

ORACLE VIRTUAL DESKTOP INFRASTRUCTURE

Enterprise Network Deployment, 10,000 25,000 Users

Determining Your Computer Resources

RunTime Chemical C/S Bundle Chromatographic Data Base Solution for Small Labs

HP E-PCM Plus Network Management Software Series

AP ENPS ANYWHERE. Hardware and software requirements

Adonis Technical Requirements

ServeRAID H1110 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Toolbox 4.3. System Requirements

Sage CRM Technical Specification

IBM Maximo Asset Management Essentials

SIP Infrastructure Performance Testing

OAISYS and Toshiba: Call Recording Solution Configuration. An OAISYS White Paper

Hard Disk Drive vs. Kingston SSDNow V+ 200 Series 240GB: Comparative Test

IPRS-7 IP/GPRS PC Receiver Software Quick Start V1.2

SAP CRM Benchmark on Dual-Core Dell Hardware

Parallels Plesk Automation

EMC Backup and Recovery for Microsoft SQL Server

Lowering Storage TCO with Iomega NAS

MrSID Plug-in for 3D Analyst

Backup and Recovery. Backup and Recovery. Introduction. DeltaV Product Data Sheet. Best-in-class offering. Easy-to-use Backup and Recovery solution

Patriot Hardware and Systems Software Requirements

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

Transcription:

GMES TERRAFIRMA ESRIN/Contract no. 17059/03/I-IW D2: Service Network Configuration Master Document Version 1 February 28 th 2006 Ren Capes (NPA) Approved by: Project Contract Officer David Morten January 31 st 2006

EXECUTIVE SUMMARY This dossier provides information relating to the specifications of the tools and procedures employed in the making of Level 1 Terrafirma products by the Operational Service (InSAR) Providers. An update to this dossier is scheduled for the first quarter of 2007. Copyright NPA and Terrafirma and collaborators, February 2006 ii

CHANGE RECORD (version 1) Version 1 issued (this version): 28.02.06 Section Page Change Copyright NPA and Terrafirma and collaborators, February 2006 iii

TABLE OF CONTENTS 1 INTRODUCTION... 1 1.1 Services provided... 1 1.2 Service Network members and roles... 2 1.3 Hardware operated or accessed... 2 1.4 Quality Control procedures... 3 1.5 IPR patents held... 3 1.6 List of data holdings... 4 1.7 Software operated... 4 1.8 Support services provided to the SN by external partners... 4 Copyright NPA and Terrafirma and collaborators, February 2006 iv

1 INTRODUCTION This shall be the reference document on the service network status. It shall include at least the following elements: 1.1 Services provided Terrafirma offers two types of product - Historical and Monitoring - which vary in their degree of GIS integration according to a 'Level' (see below). Historical products use integrations of ERS-1/2 (1991- current) and ENVISAT (2002-current) radar data already acquired and residing in archive to make products that are as up to date as the last acquisition made. Monitoring products, however, imply specific satellite tasking (or ordering) of future (or subsequent) 'visible' acquisition(s). Historical Terrafirma product are offered in three Levels of sophistication: Level 1 is a basic product providing 'raw' ground motion measurements. Level 2 involves some analysis by a geo-physical expert when the result is integrated with other geospatial data to provide an initial interpretation of the cause of the motion observed. Level 2 products are made from Level 1 products. Level 3 products involve geophysical modelling to provide a risk assessment or some forecast as to future events. Level 3 products are derived from Level 2 products. Level 1 products comprise the digital output of the PSI processing. Levels 2 and 3 products comprise this output, plus other derived maps and reports synthesised from an array of different data and information types. Landslide applications introduce two variants based on Level 2 and Level 3 products respectively: A Landslide Inventory product (LSI) which maps unstable slopes over whole basins incorporating SAR data from the archive, and a consequent Landslide Monitoring product (LSM) which focuses on the ongoing InSAR monitoring of specific slopes, incorporating data from new programmed acquisitions. LSI products are made from H1 products. LSM products are made from both LSI and M1 products. Both Landslide products utilise auxiliary data including geological, in situ and Very High Resolution optical imagery. In summary: Product Level Description H-1 Level 1 OSP output. SAR/ASAR integration of data already in archive. H-2 Level 2 Initial interpretation as to the cause of motion; in the format of a report and PPT. H-3 Level 3 Modelled product (report and PPT). M-2 Level 1 OSP output. H-1 + new acquisition(s). LSI N/A H-1 product integrated with aux data to provide inventory of motion within a large area (e.g. watershed basin), in format of report and PPT. LSM N/A LSI product + new acquisitions, giving more specific interpretation, in format of a report and PPT. The Terrafirma portfolio of products Copyright NPA and Terrafirma collaborators, January 2006 1

1.2 Service Network members and roles Operational Service Provider (H-1 PSI providers) H-2 Value-Adders Product validation Exploitation H-3 Value-Adders Product validation Landslide Inventory and Monitoring Value-adding NPA BGS BGS UNIFI TRE BRGM BRGM Gamma CESI CESI Altamira TNO TNO DLR TBD* TBD* TBD* TBD* *To be derived form 4 x H-1 products yet to be processed More information relating to the partners and their roles is available in the Technical Proposal No. NPA-GSE-4704-B-TM version 4, dated 22 nd September 2005. 1.3 Hardware operated or accessed OSP Hardware Operated Comment NPA 4 PCs running Linux. Intel Pentium 4 3.2GHz processors, 8GB RAM, 2TB total PC storage, 1Gbit network. Attached hardware with 800GB of storage configured as 400GB 100% mirrored RAID. TRE PCs running Linux. Also; LSF, Intel/GNU compilers. 32 Opteron processors, 512GB RAM, 8TB storage, 1Gbit network. Complemented by selected public domain, commercial and proprietary S/W including Matlab, ERMapper, ESRI. Gamma PCs running Linux. Altamira 8 CPU, 8GB RAM Also, 3TB parallel processing station DLR GEMOS system. 2 x SunFire 440, 1 x SunFire 490, 2 x attached hardware RAID systems, total capacity ~ 5TB. UNIFI 6 x IBM GIS workstations. 4 x single stereoscopes. Also, 5 x PCs for reporting activities. Hardware operated by OSPs Copyright NPA and Terrafirma collaborators, January 2006 2

1.4 Quality Control procedures Note that DLR are devising a common Terrafirma Quality Control Protocol (first version is due by the end of Phase 1 in October 2006). In the meantime, each OSP is using their own established QC procedures as listed in the table below: OSP QC Procedure Comment NPA Internal. Separate procedures for PSI, DifSAR and complete InSAR processing chain. TRE ITALCERT-SINCERT. TRE system conforms to ISO 9001-2000 (# 290/05). Gamma Internal. Separate procedures for SAR processing, image coregistration/geocoding and DifSAR/IPTA. Altamira Internal. Ref: AI-TF2QCSPN05_010 DLR Internal. PSI processing checked against 'PS Quality Assessment' document, version 1.0. UNIFI Internal. No formal system in place though the university is developing a common system to be ready next year. Quality control procedures currently being used by OSPs 1.5 IPR patents held OSP Patents held Comment NPA TRE Gamma None. POLIMI PS Technique and PSInSAR are international trademarks. Patents pending to protect IPTA. None. Altamira DLR None.. UNIFI None. Italy: No. MI99A001154, May 25 th 1999. USA: No. 6,583,751 B1, Jun 24 th 2003. EU: No. 1183551, Dec 17 th 2003. IPR patents held by OSPs Copyright NPA and Terrafirma collaborators, January 2006 3

1.6 List of data holdings OSP NPA TRE Gamma Altamira DLR UNIFI Data holding All TF Stage 1 ERS-SAR datastacks (ERS raw data). Topographic maps, aerial photos, VHR satellite images, geological maps, landslide inventory maps, local borehole data, water table measurements, geotechnical properties of terrain. Data holdings by OSP 1.7 Software operated OSP Software Comment NPA Gamma S/W version 21/10/2005. MSP version 11.5. ISP version 9.8. DIFF&GEO version 6.6. IPTA version 1.2 TRE PSInSAR, PSproc version 1.0. Gamma MSP version 11.5. ISP version 9.8. DIFF&GEO version 6.6. LAT version 2.4. IPTA version 1.2 Altamira Diapason version 4 and SPN version 2 Ref: DIAPASONV400_UG_06-101 SPNV210_TD_05-101 DLR PSI-GENESIS, version PSIC4 All modules have CVS archive version numbering. UNIFI None specific. Software operated by OSPs 1.8 Support services provided to the SN by external partners None Copyright NPA and Terrafirma collaborators, January 2006 4

DOCUMENT END Copyright NPA and Terrafirma collaborators, January 2006 5