FC:533 CONSTRUCTAFLOOR WET AREA FLOORING CEMINTEL RESIDENTIAL INTERNAL WET AREA FLOORING SYSTEM



Similar documents
IMPACT DAMAGE RESISTANT WALL SYSTEMS

FC:121 EXTERNAL CLADDING & EAVES LINING CSR CEMINTEL

AQUATEC WET AREA FLOORING AUSTRALIA AUGUST 2005 INSTALLATION MANUAL

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

12.1 Schlüter -KERDI-BOARD

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Scope of works. Name Job# TBA -1. Project: Bathroom Renovation

December J-Ply Roofing, Flooring and Decking

Water Resistant Plasterboard

USER GUIDE Easier, Safer, Betta! WATERPROOFING

WATERPROOFING OF WET ROOMS

Clad Direct Glaze Window Installation Instructions

Melbourne balcony Assessments

Sun Windows General Information Sun New Construction Window Installation Instructions

Window Installation Instructions

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Shower Walls and Tub Surrounds

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Passive Fire Protection

Manual lifting and handling

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Installation Guide. Bath and Wall Surrounds SERIES B

AA Solar and Sun Power Plus

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Composite Stone Veneer

Steel-framed Walls. Insulation

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Beautifully Traditional

HOW-TO LAY HARDBOARD OR PLYWOOD FLOOR OVERLAY

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

COASTLINE QUADRANT ENCLOSURE. Installation / Maintenance Instructions Rev

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

How to Install Hardwood Flooring Over a Sub Floor

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

WATERPROOFING FOR CONCRETE STRUCTURES

Residential Roofing Guide

The WANZ Guide to Window Installation

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

USER GUIDE Easier, Safer, Betta! gripsetbetta.com WATERPROOFING

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

How to Install GoBoard:

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

Maintenance & repair Solutions

Timber Decks. Technical Note. March 2007

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

Important Information

We re about to build.

Industrial Adhesives and Tapes Division 3M Center Building 225-3S-06 St. Paul, MN

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Waterproofing construction Joints

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Brick Veneer Construction

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Basement Window Installation Guide Hopper and Sliding

IMPORTANT INFORMATION

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses (Revised 19 th Jan 2011)

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Destiny Shower Enclosure Installation Instructions

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

PHOENIX TAPWARE. Gloss. Shower/Wall Mixer RRP: $ Product Code: Available Finishes: GS780. Chrome MATCH WITH...

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

8.7 Schluter -KERDI-LINE

BLACK JACK ALL WEATHER ROOF COATING

Residential Inspection Guidelines

INSTALLATION INSTRUCTIONS FOR LAMINATE FLOORING

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses (Revised 2 nd Feb 2013)

PB301 July Lightweight Building Solutions. Bushfire Protection.

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Installation Window Building In Details

Mold Preventing I nterior System

Schluter -Shower System Installation Handbook Bonded Waterproofing System for Tiled Showers, Steam Showers, Steam Rooms, and Bathtub Surrounds

Cost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME)

Facade systems. Technical specification. ComTex facade panel and fixing system

Acrylic Walls Installation Instructions

Transcription:

CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING FC:533 RESIDENTIAL INTERNAL WET AREA FLOORING SYSTEM MARCH 2015 Constructafloor Wet Area flooring is an advanced, lightweight, fibre cement flooring that offers both speed and quality in construction with significant time savings.

2 CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING CONTENTS DESCRIPTION 2 APPLICATIONS 2 ADVANTAGES 2 COMPONENTS 2 3 DESIGN CONSIDERATIONS 3 SHEET INSTALLATION 4 7 FLOOR FINISHES 7 9 GENERAL AREA WATERPROOFING 9 SHOWER RECESS WATERPROOFING 10 MAINTENANCE 10 HANDLING & STORAGE 11 SHEET PREPARATION 11 HEALTH & SAFETY, WARRANTY 12 CONTACT DETAILS 12 DESCRIPTION Constructafloor Wet Area flooring is an advanced, lightweight, fibre cement flooring sheet. Constructafloor Wet Area flooring has a flat surface with a tongue and grooved joint to the two long edges of the sheet. These edges are coloured yellow for easy identification. Constructafloor Wet Area flooring can be installed with a pneumatic nail gun for ease of installation. The joint between sheets is filled with flexible sealant to provide a flat surface suitable to accept a wide range of surface toppings. Constructafloor Wet Area flooring conforms to the requirements of AS 2908:2 Cellulose cement products, Part 2: Flat sheets for Type B Category 2. APPLICATIONS Constructafloor Wet Area flooring is a high strength, durable building product that is impervious to water. It can be fixed directly to structural framing to form a substrate for all domestic wet area applications. It is also suitable for interior flooring in non-wet areas. Constructafloor Wet Area flooring offers proven, reliable and cost effective solutions to all internal residential wet areas and other tiled areas. Constructafloor Wet Area flooring may be finished with carpet or sheet vinyl in areas that are not required to be waterproof. ADVANTAGES Simple and quick to install using screw or gun-s Tough durable substrate for wet areas Suitable for all tiled floor areas Lightweight and economical building material Immune to permanent water damage Will not rot, warp or burn Immune to termite attack Ideal for upper storey construction Available in a range of sheet sizes to reduce waste COMPONENTS CEMINTEL CONSTRUCTAFLOOR WET AREA SHEET Constructafloor is 19mm thick and has an approximate mass of 25.5 kg/m2. Sheets are available in the following sizes for interior wet area applications. Product 115657 600 x 2700mm 115658 900 x 1800mm PROPERTIES Specification Thickness (19mm nominal) Mass (nominal) Sheet Width Sheet Length Diagonal Difference () Value -0/+0.3 mm 25.5 kg/m2-3 /+0 mm -3/+0 mm 3 mm When combined with a suitable waterproofing system, Constructafloor Wet Area flooring offers a BCA compliant waterproof solution which may be covered with your selection of tiles or decorative finishes in a range of applications including: Bathrooms Ensuites Laundries

CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING 3 COUNTERSINKING TOOL A tungsten carbide tipped tool specifically designed for drilling and countersinking. Description 22116 Countersinking Tool BACKING ROD Polyethylene Foam Bead used to enable correct filling of joints with sealant. Description 11177 ø10mm x 50m roll FLEXIBLE SEALANT Gyprock Wet Area Acrylic : For joints in tiles and other substrates. Paintable. SikaflexPro : For joints in Constructafloor substrate and fastener heads. Product 10902 Gyprock Wet Area Acrylic 450g tube 11378 Sikaflex Pro 310ml tube Grey 39488 Sikaflex Pro 310ml tube Black Prime surfaces as recommended by the manufacturer. CONSTRUCTION ADHESIVE To be used on all framing where Constructafloor sheets are nail fixed. Product 39378 Sikaflex II FC, 310ml tube Supplied by others Fuller Max Bond Supplied by others Fuller Max Bond Pro PERIMETER FLASHING PVC angle 75 x 50mm. For use at wall/floor junction. Length 11206 3000mm NOTE: The following system components are not supplied by CSR. FASTENERS NOTE: In high corrosion zones, such as the coastal marine environment, Class 4 fasteners must be used. Nails for fixing Constructafloor Sheets: Power driven nails, 50mm D head, Class 3 or 4 finish. Screws for fixing Constructafloor Sheets: For timber framing: Countersunk head wood screws 10G x 50mm hot dip galvanised steel (class 3) or stainless steel. Pre-drill and countersink heads. For steel framing Metal Teks, 10G x 16TPI x 30mm class 3 or 4, countersunk head screws. Pre-drill and countersink heads. OR Wing tip screws, 10G x 40mm Class 3, self-embedding head. For framing with minimum BMT 0.75mm. MORTAR BED A proprietary impervious barrier assessed and classified in accordance with AAS4858. Refer to separate data sheets from Ardex and Bostik for recommendations. Other suitable products are available from Davco, Crommelin and Parchem. INSITU MEMBRANE/INTERNAL TRAY A proprietary impervious barrier assessed and classified in accordance with AAS4858. Refer to separate data sheets from Ardex and Bostik for recommendations. Other suitable products are available from Davco, Crommelin and Parchem. VINYL ADHESIVE Use products that are compatible with fibre cement substrates, such as Holdfast 1906, Dunlop Vinyl Adhesive and Polymer Engineering Vinyl Adhesive. TILE ADHESIVE Refer to separate data sheets from Ardex and Bostik for recommendations. Other suitable products are available from Dunlop, Parchem and Davco. ADHESIVE FULAPRENE 303 For fixing PVC angle to slab, timber or fibre cement flooring.

4 CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING DESIGN CONSIDERATIONS This guide refers to good practice, though it is not intended as an exhaustive statement of all relevant information. It remains the responsibility of the building designer to verify that Constructafloor Wet Area flooring is suitable for the particular requirements of any given project. The systems outlined in this manual are based on Australian Standard AS3740: Waterproofing of wet areas within residential buildings. This Australian Standard details the design, materials, and installation requirements for wet areas within residential buildings. A wet area is defined by the standard as an area within a building supplied with water from a water supply system, including bathrooms, showers, laundries and toilets, but excluding kitchens, bars and similar. Elements within wet areas may have requirements to be water resistant or waterproof, as set out in the Building Code of Australia. Waterproof areas are floors within and near showers, and at junctions between floors and walls in showers and bathrooms. A waterproof membrane must be applied in these areas. SYSTEM COMPONENTS Constructafloor Wet Area flooring is a fibre cement product and waterproofing and lining components should be chosen that are recommended by their manufacturer for fibre cement substrates. Components including sealers, membranes, mortars, s and finishes should be considered for their compatibility with each other, as well as with the substrate, and their performance as a complete system. Extensive testing has been carried out by Ardex and Bostik and a number of system recommendations are available. Contact CSR for details or refer to data sheets at cemintel.com.au. FRAMING Constructafloor Wet Area flooring can be fixed to timber or steel floor joists at maximum 450mm centres. s and trimmers must have a minimum face fixing width of 45mm or to floor joist manufacturer's requirements. All perimeters must be supported on framing. As a minimum requirement, framing shall be in accordance with the following standards: AS1684 Residential timber-framed construction. AS/NZS4600 Cold-formed steel structures. AS3623 Domestic metal framing. Timber shall be seasoned or have reached an equilibrium moisture content of 16% or less at the time of framing. Unseasoned timber is not recommended. The design and construction of the steel frames should be considered in conjunction with the advice from the manufacturer. In highly corrosive environments, appropriate measures should be taken to protect the frame from corrosion. Fixings to steel joists are suitable up to a 2.0mm base metal thickness (BMT), contact CSR for fixing information where steel BMT is greater than 2.0mm. LOADS Constructafloor Wet Area flooring has been designed to resist a live load of 2.0kPa and a 1.8kN point load with 450mm spacing of supports. TILING When selecting tiles ensure they are fit for purpose and an appropriate compatible with a fibre cement substrate is selected. In all cases the tile and tile manufacturer s instructions should be followed. For further advice, refer to Australian Standard AS3958.1 Guide to the installation of ceramic tiles. Tile must conform to Australian Standard AS2358 Adhesives - for fixing ceramic tiles. In all cases the tile and tile manufacturers instructions should be followed. SHEET INSTALLATION SHEET LAYOUT Constructafloor Wet Area sheets are fixed directly to the floor joists. Sheets are laid with tongue and groove joints perpendicular to the joists. Sheet ends must align with the centre of joists, and may be staggered or aligned. Sheet ends must be aligned at control joints. All perimeters must be supported on framing. Leave a 10mm gap at wall junctions. Sheets must be fully supported wherever a tongue or groove profile has been removed or where the profiles do not engage fully. CONTROL JOINTS joints between Constructafloor Wet Area sheets must be provided at 9m centres maximum at tongue and groove edges to allow for differential movement in both the materials and the structure. Where the floor is exposed to direct sunlight, control joints are to be spaced at 6m centres maximum. Refer to FIG 1, 2 and 3. joints between sheets must be provided at butt joints in accordance with FIG 1, 2 or 3. Sheet ends must be aligned at control joints. joints in sheets must also be provided at changes in direction of sheets, at doorways and at any structural control joints. joints in the finish layer must be aligned with control joints in the sheets. Refer to installation details.

CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING 5 FIG 1: Typical Sheet & Layout 600 x 2700mm Sheets Staggered & System shown 10mm gap at walls Sheet & Tile 9000mm Flexible Waterproofing membrane Sheet 5400mm Tile 5400mm Remove tongue and groove from sheet edges Blocking to support sheet edges and backing rod Flexible 450mm Waterproofing membrane Sheet Tile FIG 2: Typical Sheet & Layout 600 x 2700mm Sheets Aligned & System shown 10mm gap at walls Sheet & Tile 9000mm Flexible Sheet 2700mm Sheet 2700mm Tile 2700mm Tile 2700mm Remove tongue and groove from sheet edges Flexible Waterproofing membrane Blocking to support sheet edges and backing rod Sheet Tile 450mm Waterproofing membrane

6 CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING FIG 3: Typical Sheet & Layout 900 x 1800mm Sheets Staggered & Direct Fix Tile System shown 10mm gap at walls 900 x 1800mm sheets shown Sheet & Tile 9000mm Flexible Sheet 5400mm Tile 5400mm Remove tongue and groove from sheet edges Blocking to support sheet edges and backing rod Flexible 450mm Backing Rod Sheet Tile FIXING SHEETS Tiled Areas Panels are installed with the side printed 'This side down for tiling' facing down. A chamfer at each tongue and groove edge allows for waterproofing sealant. Tongue and groove joints must be butted tightly together prior to fixing. Refer to detail. Butt joints must be fixed to the frame leaving a 2mm minimum gap between each flooring sheet to allow for joint sealant. s must be installed leaving a 5mm minimum gap between sheets to allow for the installation of backing rod and sealant. This gap is important to accommodate movement of the building materials and structure. Fix sheets with screws at 450mm centres maximum along framing. Alternatively, where sheets are to be nail fixed, apply a continuous bead of construction to sheet framing and power nail at 200mm centres maximum. Fixings must be kept a minimum of 50mm from corners. Refer to installation details for edge distance requirements. Fixings should finish below the finished level of the Constructafloor sheet and any indentation should be filled with flexible sealant. Screw or nail fix sheets as for tiled areas. Fixings should finish below the finished level of the Constructafloor sheet and any indentation should be filled with epoxy or polyester builder s filler. FIG 4: Fastener Countersinking Detail Constructafloor covered Floor Handy Hint: To prevent sealant spillage, place a strip of tape over the screw hole prior to drilling, then remove once screw is in place and covered with sealant. Vinyl Finish Panels are installed with the side printed 'This side down for tiling' facing up. There is no chamfer at tongue and groove edges. All panel joints are to be butted tightly together prior to fixing. Install control joints as for tiled areas.

CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING 7 FIG 5: Constructafloor Fixing Detail Nail Fixing T&G 200mm max 50mm from corners 2mm gap at butt joint 200mm max FLOOR FINISHES MORTAR BED & TILE If a fall to waste is required, tiles must be laid on a mortar bed. Form control joints in the mortar bed/tile layers to correspond with the control joints in sheets. The mortar bed should be allowed to cure for approximately 10 days before tiling commences. Note: Do not tile over control joints in the mortar bed. Construction with FIG 7: Typical T&G with & Tiles FIG 6: Constructafloor Fixing Detail Screw Fixing 450mm max T&G 50mm from corners Screw fixing 450mm max Waterproof Membrane when required Continuous bead of construction with 2mm gap at butt joint SHEET JOINTING Tiled Areas Sheets must be fixed in position ready for joints to be completed. Ensure joints are clean and clear of any dust that may prevent sealant adhering. Place a strip of masking tape along both sides of the joint to ensure a neat finish is achieved. For s, press foam backing rod into joint pressing down firmly against joist leaving approximately 6mm gap at top. FIG 8: Typical Butt with & Tiles Fill tongue and groove, butt and control joints with flexible sealant, finishing flush with the sheet surface. s must be smoothed within 10 minutes. Remove masking tape and allow sealant to dry for approximately 24 hours. Waterproof Membrane where required 2mm Continuous bead of construction with Vinyl Finish is not required at tongue and groove or butt joints. Treat control joints as for tiled areas. Framing 4 face width or to joist manufacturer s requirements Refer to the following details for jointing and fixing information.

8 CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING FIG 9: at Butt with & Tiles DIRECT FIX TILES If a fall to waste is not required, tiles may be fixed directly to Constructafloor Wet Area flooring (or over a waterproof membrane). FIG 11: Typical T&G with Direct Fixed Tiles Approx. 6mm Waterproof Membrane where required Construction Backing rod and joint sealant Continuous bead of construction with Framing 4 face width or to joist manufacturer s requirements FIG 10: at T&G with & Tiles FIG 12: Typical Butt with Direct Fixed Tiles Continuous bead of construction with Approx. 6mm 2mm Waterproof Membrane where required Continuous bead of construction with Backing Rod and Framing 4 face width or to joist manufacturer s requirements Blocking to support sheet edges and backing rod FIG 13: at Butt with Direct Fixed Tiles Backing Rod Approx. 6mm Continuous bead of construction with

CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING 9 FIG 14: at T&G with Direct Fixed Tiles GENERAL AREA WATERPROOFING Approx. 6mm Continuous bead of construction with Backing Rod and Blocking to support sheet edges and backing rod PERIMETER FLASHING Perimeter flashing must be used at the floor/wall junctions in all general wet areas, and must extend a minimum of above finished floor level. Two recommended methods are: PVC Flashing Angle, 75 x 50mm fixed to floor only using Fulaprene 303 Adhesive. Insitu membrane, 50mm wide to floor and up wall to minimum above highest point of finished floor level. FIG 16: Perimeter Flashing with PVC Angle CeminSeal Wallboard VINYL Stud Ceramic Tiles Nogging for wallboard fixing Flexible A flush surface is required to avoid blemishes in the finish. Fill minor imperfections and cover fastener heads with epoxy or polyester based builder s filler. Any joint misalignments must be filled or sanded smooth. Alternatively, a floor leveller such as Arditex NA may be used over larger areas. 75mm 2 Ensure all panels are clean, dry and free from dust. Follow manufacturer s recommendations for installing the vinyl sheeting. It is recommended that a primer be used for polymer type s. Wall Plate Structural Sheet Flooring Floor 50mm Approved Flashing fixed to floor only FIG 15: Typical T&G with Vinyl Finish Vinyl and Continuous bead of construction with FIG 17: Perimeter Flashing with Flashing Strip Membrane finished minimum above highest point of finished floor surface Stud CeminSeal Wallboard Ceramic Tiles Insitu Membrane applied to face of wall lining and floor Flexible Masking Tape Foam Plastic Rod used as essential bond breaker Wall Plate Minimum 50mm Structural Sheet Flooring Floor

10 CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING SHOWER RECESS WATERPROOFING INSITU APPLIED MEMBRANE A continuous insitu membrane must be applied to shower recess areas as shown in FIG 18, 19 and 20. Membranes must comply with AS4858 and be recommended for use with a fibre cement substrate. Installation is to be in accordance with the manufacturer's recommendations. For second storey installations, it is recommended that a continuous insitu membrane be applied to the entire wet area floor and up the walls to a minimum 150mm above the floor sheet level and/or to a minimum 50mm above any shower hob. PLUMBING WASTES It is important that all plumbing wastes are sealed, particularly in a shower recess. A PVC waste yoke must be bonded to the flooring and the waste pipe before fitting grates and other fixtures. A waste fitting incorporating a leak control system is recommended to enable any moisture to drain from beneath the floor tiles. FIG 20: Typical Waste Detail Waste grate with drainage slots NOTE: For further details on waterproofing refer to Australian Standard AS3740. Membrane continued into waste yoke Waste Pipe Waste Yoke bonded to sheet and waste pipe FIG 18: Typical Shower Recess with Hob 150mm Shower Screen sealed with flexible sealant at hob and walls Continuous insitu membrane to shower recess floor, over hob, and up walls Mortar bed Masonry Hob Wall sheeting 50mm Flexible MAINTENANCE The durability of the system can be maintained by periodic inspection, including examination of the surface finishes, flashings, penetrations and membranes. Any cracked or damaged flashings or seals that would allow water ingress must be repaired immediately. 7 FIG 19: Typical Hobless Shower Recess Shower Screen sealed with flexible sealant at floor and walls Wall sheeting 150mm Continuous insitu membrane to shower recess floor, over angle and up walls Mortar bed Waterstop fixed to floor 7

CEMINTEL CONSTRUCTAFLOOR WET AREA FLOORING 11 HANDLING & STORAGE Constructafloor Sheets must be treated with care. During handling, avoid damage to edges, ends and surfaces. Sheets must be carried on edge. All sheets must be stacked flat, clear of the ground, and supported at 300mm maximum centres on a level platform. Material must be kept dry, preferably by being stored inside the building. Sheets exposed to moisture prior to installation may be subject to shrinkage, and voiding of warranty. Protect from contaminants such as silicone spray. Where it is necessary to store panels outside, they must be protected from the weather. Sheets must be dry prior to fixing, joint sealing and coating. SAFETY When cutting, drilling or grinding sheets using power tools, always ensure the work area is well ventilated. CSR recommends the use of appropriate dust reduction methods. An approved dust mask (AS1715 and AS1716) and safety glasses (AS1337) must be worn. CSR recommends that hearing protection be worn. SHEET PREPARATION Cement based levelling products may be used. Sheets should not be sanded. CUTTING Power Saw Sheets should be cut from the back using a power saw. CSR recommends using the FESTO TS 55 EBQ Plunge Cut Saw, diamond tipped blade and appropriate dust reduction methods. 107231 107224 PENETRATIONS Product FESTO TS 55 EBQ Plunge Cut Saw with 1400mm Guide Rail FESTO Diamond Tipped Blade for TS55 (for cutting Edge Cladding, fibre cement sheet, etc.) Penetrations in sheets may be cut or drilled prior to installation. Cut from the back or drill from the front. Cut penetrations oversize by 8 10mm all around. Seal penetrations in accordance with recommended products.

is a trademark of CSR Limited WWW.CEMINTEL.COM.AU RESIDENTIAL INTERNAL WET AREA FLOORING SYSTEM FC:533 HEALTH & SAFETY WARNING Fibre Cement products contain crystalline silica. Repeated inhalation of fibre cement dust may cause lung scarring (silicosis) or cancer. Do not breathe the dust. When cutting sheets, use the methods recommended in this brochure to minimise dust generation. If power tools are used, wear an approved dust mask (respirator). These precautions are not necessary when stacking, unloading or handling fibre cement products. For further information and for a Material Safety Data Sheet, phone 1800 678 068. WARRANTY CSR Building Products Limited ( CSR ) warrants its Constructafloor ( Product ) to remain free of defects in material and manufacture for 10 years. In the event of any failure of the Product caused by the direct result of a defect in the material or manufacture of the Product, CSR will at its option replace or repair, supply an equivalent product, or pay for doing one of these. This warranty does not apply where the Product has been used in any manner not in accordance with the manufacturer s instructions, nor the reuse of the Product after its initial installation. This includes installation and maintenance in accordance with the relevant technical manual, current copies are available at cemintel.com.au/installation or by contacting 1300 CEMINTEL. CSR recommends that only those products, components and systems recommended by it be used and the project must be designed and constructed in strict compliance with all relevant provisions of the current Building Code of Australia, regulations and standards. All other products, including coating systems, applied to or used in conjunction with the Product must be applied or installed and maintained in accordance with the relevant manufacturer s instructions and good trade practice. CSR will need to be satisfied that any defect in its Product is attributable to material or manufacture defect (and not another cause) before this warranty applies. Without limiting the foregoing, CSR will not be liable for any claims, damages or defects arising from or in any way attributable to poor workmanship, poor design or detailing, settlement or structural movement and/or movement of materials to which the Product is attached, incorrect design of the structure, high levels of pollution, acts of God including but not limited to earthquakes, cyclones, floods or other severe weather conditions or unusual climatic conditions, efflorescence or performance of paint/coatings applied to the Product or normal wear and tear. Other than as expressly set out in this warranty, and the guarantees that can not be excluded under The Australian Consumer Law (Schedule 2 of the Competition and Consumer Act 2010 (Cth)) (and any other law), CSR excludes all other warranties and guarantees with regard to the Product including all guarantees and warranties that may apply at law. To the extent that it is able to do so, CSR excludes all liability for loss and damage (including consequential loss) in connection with the Product. This exclusion does not apply where the Product is sold to a consumer and is a good of a kind ordinarily acquired for personal, domestic or household use or consumption. The following statement is provided where the Product is supplied to a buyer who is a consumer under the Australian Consumer Law: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The benefits of this warranty are in addition to other rights or remedies of the consumer under law in relation to the goods or services to which the warranty relates. Notification of a warranty claim must be made to CSR prior to any return of the Product. Failure to allow CSR to examine an alleged faulty Product in-situ may result in the voiding of this warranty. To make a claim under this warranty, you must contact CSR on 1300 CEMINTEL, or write to one of our state offices, cemintel.com.au/contactus. All expense of claiming the warranty will be borne by the person making the claim. CSR may require documentation supporting the claim to be provided., Constructafloor and CSR are trademarks of CSR Limited. FC533.BMS1095.0315 CONTACT DETAILS MARCH 2015 CSR Sales Support Tel: 13 17 44 Fax: 1800 646 364 CSR designlink Technical Support Service Tel: 1800 621 117 Emaill: designlink@csr.com.au New South Wales and ACT 376 Victoria Street, Wetherill Park NSW 2164 Queensland 768 Boundary Road, Coopers Plains QLD 4108 Victoria 277 Whitehall Street, Yarraville VIC 3013 South Australia Lot 100 Sharp Court, Mawson Lakes SA 5095 Western Australia 19 Sheffield Road, Welshpool WA 6106 Tasmania 11 Farley St, Derwent Park, TAS 7009 Northern Territory Cnr Stuart Hwy & Angliss St, Berrimah NT 0828