NXP Basestation Site Scanning proposal with AISG modems



Similar documents
NXP High-Speed Muxes/Switches. Supporting DP/PCIe/SATA/mSATA/SAS/USB/LVDS

RX-6 Six In - One Out All in One Receive Antenna Switch Local and Remote Control System RX6ACI User Manual Version 2.1

Disclaimers. Important Notice

For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.

ChipScope Pro Tutorial

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

Appendix B RCS11 Remote Communications

SM1231 USER GUIDE SM1231 RF MODULE USER GUIDE

Ethernet Radio Configuration Guide

SAN Conceptual and Design Basics

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

Wireless Remote Video Monitoring

Alliance System Ordering Guide

i-poi TM Intelligent Point Of Interface The smart, streamlined base station interface solution for distributed antenna systems.

Date Rev. Details Author

Basics of Preventive Maintenance and Troubleshooting DRAFT

LoRa FAQs. 1 of 4 Semtech. Semtech Corporation LoRa FAQ

RapidIO Network Management and Diagnostics

Make a folder named Lab3. We will be using Unix redirection commands to create several output files in that folder.

Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist

Information Note Connecting a BRI - checklist

Connections and Setup

Single channel data transceiver module WIZ2-434

ProCurve Networking. Troubleshooting WLAN Connectivity. Technical White paper

Process Control and Automation using Modbus Protocol

Tower Mounted Amplifiers, Diagnostics and Isolation Measurements

Software User Guide UG-461

PS 155 WIRELESS INTERCOM USER MANUAL

Node A. Universal Multi-Band, Multi-Service, Software-Based Repeater Platform. So Flexible You Can Accommodate Just About Any Application Requirement

Network-wide Diagnostics

R4 AIS Transponder System

Wireless Remote Video Monitoring

Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

ON-GUARD. Guard Management System. Table of contents : Introduction Page 2. Programming Guide Page 5. Frequently asked questions Page

Review Methods Configuration, Administration and Network Monitoring in High-Rate Onboard Networking Standards

SATEL NMS PC USER MANUAL. SATEL NMS PC Version User Manual Version 2.5

ETS4 Diagnostics. KNX Association

Troubleshooting File and Printer Sharing in Microsoft Windows XP

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

APR-PRT3 Printer Module: C-Bus Programming Instructions

AVANTI 3015ip TELEPHONE INSTALLATION NOTES

L5354 ControlNet Communications Interface

Technical description MX-1 VB Edge

F2400 FOM II Series Fiber Optic Modem Technical Manual

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

System Release Notes Express5800/320LB System Release Notes

Software version 1.1 Document version 1.0

High Availability for Citrix XenApp

AN4128 Application note

Intrusion Detection Systems (IDS)

Skyus 3G. Quick Start Guide Verizon

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

A network is a group of devices (Nodes) connected by media links. A node can be a computer, printer or any other device capable of sending and

AEI RAIL NETWORK SERVER User Manual

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

1-Port DS3 IMA Module Description and Technical Specifications. The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA L0S

Link Layer Discovery Protocol

Interfacing the Yaesu DR 1X

MISSING NEIGHBOR ANALYSIS

Connections and Setup

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

USER MANUAL. SAILOR 100 Satellite TV

SMART Ink 1.5. Windows operating systems. Scan the following QR code to view the SMART Ink Help on your smart phone or other mobile device.

orrelog Ping Monitor Adapter Software Users Manual

FiOS Self-Installation guide for VIDEO MEDIA SERVER EQUIPMENT

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

integrated lights-out in the ProLiant BL p-class system

Intel Dialogic System Release 6.1 CompactPCI for Windows

IntraVUE Diagnostics. Device Failure

Modbus Communications for PanelView Terminals

Allen-Bradley/Rockwell

Environmental Monitoring: Guide to Selecting Wireless Communication Solutions

INTEGRATED CIRCUITS I CODE SLI. Smart Label IC SL2 ICS20. Functional Specification. Product Specification Revision 3.1 Public. Philips Semiconductors

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

USER MANUAL VS92A / VS94A / VS98A

Crow Limited Warranty. Print Version 017

Computer Network. Interconnected collection of autonomous computers that are able to exchange information

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

MANUAL FOR RX700 LR and NR

ABUS WIRELESS ALARM SYSTEM

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Internet Firewall CSIS Packet Filtering. Internet Firewall. Examples. Spring 2011 CSIS net15 1. Routers can implement packet filtering

Guide for Performing a Wireless Site Survey. 2.4 GHz IEEE g/802.11b/

Simplifying Data Data Center Center Network Management Leveraging SDN SDN

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

How to setup a serial Bluetooth adapter Master Guide

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE

WASP User Manual. Revision: 1.6. (c) 2012 North Pole Engineering, Inc.

Milestone Edge Storage with flexible retrieval

PUF Physical Unclonable Functions

Transcription:

NXP Basestation Site Scanning proposal with modems Advanced Systems White Paper by Jaijith Radhakrishnan There are a number of connectivity issues associated with cellular base stations that can increase the cost of operation. Prior to commissioning, the tower is typically given a visual inspection to ensure connectivity. The inspection, which involves verifying connectivity for the antenna line devices (ALDs) and the base station controller (), requires the presence of a field technician and, because data is usually gathered visually (and not electronically), can be prone to error. Some connectivity faults are difficult to detect with the eyes alone, and it's possible for the technician to miss a connection. Once the tower is operational, connectivity problems can be hard to identify from the operations and maintenance center, and equipment may have to be brought offline to debug the issue. Over time, connectivity can deteriorate, due to damage to the ALDs and other tower equipment. Connectors and cables can't really be assessed accurately with a quick visual inspection, so detailed and time-consuming onsite inspections may be needed to keep things running. Also, complex problems may require multiple site visits to resolve. Making connectivity information available, via an electronic process, to a central operations and maintenance center, would save having to send personnel to the site and could reduce the possibility of errors. At present, however, there is no industry-defined method for automatically scanning device connectivity. The Antenna Standards Interface Group () mainly addresses equipment failure, with methods for tuning ALD parameters to make network operations

more efficient, but these methods don't currently address the connectivity between devices in the tower. Creating a system for remote scanning of connectivity would most likely require a joint effort from base station and ALD manufacturers, as well as network operators. One such system, currently under consideration, is called Site Scan. Site Scan is a reliable, scalable method that makes it possible to verify base station connectivity remotely. As an electronic process, Site Scan can be initiated automatically and, under normal conditions, can be performed at any time without affecting tower operations. Site Scan gathers connectivity information and detects improper or inconsistent connections. Any irregularities are flagged for further diagnostics. Site Scan can also detect the kind of damage that can occur over time, so there is less need for periodic visits to the tower for preventive maintenance. Site Scan provides a new way for the operations and maintenance center to gather connectivity data remotely and, as a result, promises to have a significant impact on the overall cost of network operations. This paper describes how primary and secondary devices support Site Scan, and outlines the scanning sequence used to trace connections. It also explains how connectivity information is stored, and suggests ways to use the Site Scan information to diagnose and debug issues. Device requirements for Site Scan Site Scan assumes the modem can respond to any port in the device or that there is one modem connected to each port. In a cellular tower, the scan can be initiated by the or by a remote request from the operations and maintenance center. This scan can be performed in real time, while the base station is operational. This is because the scan is performed using the commands at or a custom carrier frequency that doesn't interfere with RF communication. To evaluate connectivity, the tower devices need to know how many ports they have and which port is responding to the current command. All responses are evaluated in real time using a scan sequence. This means the doesn't have to have any device or connectivity information to perform the scan. The only requirement is that each device, including the, must know how many ports it has. This Site Scan procedure can be performed at any time after the device is initialized and all addresses have been assigned. To evaluate connectivity, the bus must be configured as a point-to-point connection. This can easily be done by reconfiguring the transmit and receive lines. Note that, to perform Site Scan, the modems must be configured in bypass or repeat mode. Details are given below.

A. All the ports of the secondary and primary devices need to be -enabled This includes RF and ports. To electrically trace connectivity, point-to-point access of all the ports is needed. This requires additional features on each device but the final cost is lower than compared to traditional on-site maintenance. Having -enabled ports means all devices are capable of receiving or sending messages through their ports. Devices are also aware of which port is used for communication. B. Secondary devices should be able to configure the ports in Site Scan repeater mode At startup, all secondary devices act as normal devices and can run the regular protocol. During Site Scan, the base station may be required to configure secondary devices in repeater mode' to communicate with other device ports. The configuration can be performed with minimal hardware features. This feature is important for secondary devices that have a pass-through connection configured as a multi-drop bus. The following example shows the two modes of connection on a. Figure 1 shows connectivity during address scan and normal operation. 2 Modem Tx Rx Controller Controller 3 Modem Tx Rx The diagram shows only related connectivity for a with uplink connection for a system which has integrated antenna. Shown the connectivity of normal operation, including address scan mode. RF connectivity is not shown. This is a multi-drop bus and many devices are connected to the same bus. The is a [secondary] device. The [primary] device is connected to the port 0, and RET may be connected to port 2. Rx Tx Modem 0 Rx Tx Modem 1 Figure 1 connectivity during address scan and normal operation The diagram shows two controllers but a single controller can do the job. The number of repeater combinations increases as the number of ports the increase. An easy configuration uses only two ports in repeater mode, as shown in Figure 2. 2 3 Modem Tx Rx Controller Controller Modem Tx Rx The diagram shows only related connectivity for a in Site Scan repeater mode. RF connectivity is not shown. This is point-to-point bus connectivity. The secondary device responds to commands addressed to it, or repeats the command/response to the other port. The purple arrow indicates either the crossed Tx and Rx connectivity or store-andforward from Rx to Tx. Rx Tx Modem 0 Rx Tx Modem 1 Figure 2 connectivity during Site Scan repeater mode

This is a point-to-point connection, referred to as a repeater mode connection in the rest of this document. In this mode, the repeater ports exchange the commands and responses. Commands and responses received from port 0 are repeated to port 2, and vice versa. C. All Site Scan-enabled devices know the number of ports they have and their attributes Using connectivity information and the attributes of these ports, the central operations and maintenance center can run various diagnostics. D. All Site Scan-enabled devices need to support commands related to Site Scan All Site Scan enabled primary devices shall support additional commands for the Site Scan. All secondary devices need to understand and respond to primary commands. E. The scan initiator must know the intended connectivity of the devices Site Scan can be initiated from the or from the central operations and maintenance center. To evaluate connection problems, such as open or wrong connections, the scan initiator must know the intended connectivity of the tower. This is cross-checked with actual connectivity to evaluate intended connectivity or to find bad/wrong connections. Alternatively, a set of rules can be maintained and the scan can check for rule violations. For example, a rule could be RF output port should not be connected to another RF output port or port and antenna port need to be in same band of operation. Site Scan command sequence The concept of Site Scan can be explained using a simple example. (The example can be extended to support more complex systems.) The example uses a base station controller (), tower mounted devices (), and an antenna or remote electrical tilt (). The concept device IDs are indicated in each figure. All ports, devices, and layers are named with numbers starting from 0. For the device ID, the first digit indicates the layer and the second digit is the device's position in that layer. For example device_ id_10 is the first device on the second layer. The device ID is for reference only and does not match the ID of the device. Figure 3 gives the key for reading the diagrams that follow. First command, action Black connector means it is not scanned yet Green connector means it is scanned Layer 2 Devices Second command/response, action sequence Purple arrows indicate repeater ports Blue box means it is not scanned Layer 1 Devices Red circle means it is the targeted connectivity in current scan procedure Green box means it is scanned and status is updated Layer 0 Devices Figure 3 Figure 3 Key for reading diagrams

Site Scan can be initiated by the primary device () and can be triggered by the following events: Self starting based on any algorithm or periodically Remote request from operations and maintenance The following diagrams give the sequence for Site Scan. Figure 4 Site Scan command sequence (1) 1. Primary device stores its number of ports (2) and its unique device ID 2. Primary device starts with status (0/2) ports scanned 3. Primary device sends command get_connected_port (port_0) Figure 4 Figure 4 Site Scan command sequence (1) Figure 5 Site Scan command sequence (2) 4. If secondary device receives this command, it responds with Unique device ID () Number of ports (4) Port number used to send the response (port_0) 5. Primary device infers the following when it receives the response.port_0 connected to.port_0 Device_id_10 has 4 ports 6. Primary device updates the above info in its database and updates the status (1/2) ports scanned (1/4) ports scanned Figure 5 Figure 5 Site Scan command sequence (2)

Figure 6 Site Scan command sequence (3) 7. Primary device searches its status to find where it stopped (1/4) ports scanned 8. Next port to be scanned is port_1 9. Primary device searches the data base to see which port is connected to (port_0)-> (port_0) 10. Primary device sends command repeat (, port_0, port_1) 11. If secondary device receives above command, it will evaluate whether this repeat mode is possible. If yes, it configures the ports. If no, it sends a response that the requested mode is not possible. (This example assumes the port_0, port_1 repeater mode is NOT supported.) Figure 6 Figure 6 Site Scan command sequence (3) Figure 7 Site Scan command sequence (4) 12. Primary device searches its status to find where it stopped (port_1) cannot access 13. Next port to be scanned is port_2 14. Primary device searches the data base to find which port is connected to (port_0)-> (port_0) 15. Primary device sends command repeat (, port_0, port_2) 16. If secondary device receives above command, it evaluates whether this repeat mode is possible. If yes, it configures the ports. If no, it sends a response that the requested mode is not possible. This example assumes the port_0, port_2 repeater mode is supported, so secondary device repeats the command it receives at port_0 to port_2 repeat the response it receives at port_2 to port_0 Figure 7 Figure 7 Site Scan command sequence (4)

Figure 8 Site Scan command sequence (5) 17. Primary device searches the data base to find which port is connected to (port_0)-> (port_0) 18. Primary device sends command through port_0 get_connected_port (, port_2) 19. If secondary device receives above command, it repeats the command to port_2 20. If secondary device receives above command it responds with Unique device ID () Number of ports (2) Port number on which it sends the response (port_0) Figure 8 Figure 8 Site Scan command sequence (5) Figure 9 Site Scan command sequence (6) 21. If secondary device receives above response it will repeats the response to port_0 22. Primary device infers.port_0 connected to.port_2 Device_id_20 has 2 ports 23. Primary device stores above info in a database and updates the status (1/2) ports scanned (2/4) ports scanned (1/2) ports scanned Figure 9 Figure 9 Site Scan command sequence (6)

Figure 10 Site Scan command sequence (7) 24. Primary device searches it status to see where it stopped (1/2) ports scanned 25. Next port to be scanned will be port_1 26. Primary device searches the data base to see which port is connected to (port_0)-> (port_2)-> (port_0) 27. Primary device sends command repeat (, port_0, port_1) 28. If secondary device receives above command, it evaluates whether this repeat mode is possible. If yes, it configures the ports. If no, it sends a response that the requested mode is not possible. This example assumes the port_0, port_1 repeater mode is supported, so secondary device. So secondary device will repeats the command it receives at port_0 to port_1 repeats the response it receives at port_1 to port_0 Figure 10 Figure 10 Site Scan command sequence (7) Figure 11 Site Scan command sequence (8) 29. Primary device searches the data base to see which port is connected to (port_0)-> (port_2)-> (port_0) 30. Primary device sends command through port_0 get_connected_port (, port_1) 31. If secondary device receives above command, it repeats the command to port_1 32. If secondary device receives above command, it responds with Unique device ID () Number of ports (4) Port number on which it sends the response (port_3) Figure 11 Figure 11 Site Scan command sequence (8)

Figure 12 Site Scan command sequence (9) 33. If secondary device receives above response, it repeats the response to port_0 34. If secondary device receives above response, it repeats the response to port_0 35. Primary device infers.port_3 connected to.port_1 has 4 ports 36. Primary device stores above info in a database and updates the status (1/2) ports scanned (3/4) ports scanned (2/2) ports scanned Figure 12 Figure 12 Site Scan command sequence (9) Figure 13 Site Scan command sequence (10) 37. Primary device searches its status to find where it stopped (2/2) ports scanned. Since connections are complete, it goes to the next one in reverse order (3/4) ports scanned 38. Next port to be scanned is port_1 39. Primary device searches the data base to find which port is connected to (port_0)-> (port_0) 40. Primary device sends command repeat (, port_3, port_1) 41. If secondary device receives above command, it evaluates whether this repeat mode is possible. If yes, it configures the ports. If no, it sends a response that the requested mode is not possible. This example assumes the port_1, port_3 repeater mode is supported, so secondary device: repeats the command it receives at port_3 to port_1 repeats the response it receives at port_1 to port_3 Figure 13 Figure 13 Site Scan command sequence (10)

Figure 14 Site Scan command sequence (11) 42. Primary device searches the data base to find which port is connected to (port_0)-> (port_0) 43. Primary device sends command through port_0 get_connected_port (, port_1) 44. If secondary device receives above command, it repeats the command to port_1 45. If any* device receives above command, it responds with Unique device ID () Number of ports (2) Port number on which it sends the response (port_1) *To avoid having primary devices generate the response, there can be more repeater configurations on other layers. For the sake of scan sequence it is included here. Figure 14 Figure 14 Site Scan command sequence (11) Figure 15 Site Scan command sequence (12) 46. If secondary device receives above response, it repeats the response to port_3 47. Primary device infers.port_1 connected to.port_1 has 2 ports 48. Primary device stores above info in a database and updates the status (2/2) ports scanned (4/4) ports scanned (2/2) ports scanned 49. All loops completed and all device connectivity data identified Figure 15 Figure 15 Site Scan command sequence (12)

Figure 16 Site Scan command sequence (13) Primary device sends command reset_repeat to the last device first and then goes in reverse order for all devices 51.This will restore all normal mode of operation Figure 16 Figure 16 Site Scan command sequence (13) Extending for more layers and devices The above solution can be extended to any layer. It can also be extended to any number of devices in a single layer. If there are multiple vertical connections, then the must scan one each after the other. To cover all the possibilities, the scan must proceed systematically. By setting rules and having information about the intended connectivity, bad or inconsistent connections can be identified. Star/passive (Smart Bias Tee) connectivity Star connectivity is a passive connection, so the system must have on-board intelligence to perform the scan procedure. Star connectivity must be absorbed within the ALD. This creates one more port for the device. If the device is capable of connecting the modem to these ports, it will be used during Site Scan when connectivity information is gathered. Similar to a star connector, a passive devices such as a smart bias tee, which sits outside the active ALD, cannot be scanned. Some efforts have already been made to integrate the smart bias tee into the or the antenna, and this is consistent with the Site Scan approach. There are several considerations for star/passive connectivity: Star connectivity, or splitters need to be absorbed into the devices When devices absorb these connections, each port must be -enabled Keeping the splitter outside the device defeats the scan connectivity If the device is not addressable and ALL ports are not -enabled, the scan will not be possible Repeater mode connectivity from the primary device connection port is needed for all ports Ideally, the Smart Bias Tee is absorbed inside devices like the and the antenna Command timing with repeater mode connection Several kinds of repeater connections are possible, including transmitter-to-receiver cross connections and receive, store, and forward for commands and responses. There are, of course advantages and disadvantages to each approach. With the cross-connection approach, where many modems are chained together, there may be degradations in duty cycle. This becomes increasingly important as the number of layers goes up. With the

receive, store, and forward method, there may be an increase in delay due to the storage of commands and responses. If the delay exceeds the limits of the protocol, a secondary device can be used to send the response or resend the command at a later point. The secondary can also forward the command to the repeater port and collect the response. When the repeater receives the command, the secondary forwards the collected response. Database for connectivity Connectivity information can be stored in many formats, including a netlist. This information can be sent to the operations and maintenance center for connectivity evaluation and debug purposes. The connectivity format can be binary, with defined fields, or human-readable ASCII., port_0 (.port_0), port_1 (.port_1), end;, port_0 (.port_0), port_1 (.port_1), port_2 (.port_0), port_3 (.port_1), end;,...... Some useful commands It can be very useful to get the properties of ports and devices in the base station for debug and connectivity evaluation. Some of these commands are already available in the protocol. Many of the attributes are related to the device itself but all of them can be related to ports. The following are examples: Direction of port RF frequency of port 3G standard of port Position of port Color code of port Diagnostics of connectivity Knowing the various properties of components and ports in a remote base station (such as environmental factors and connectivity data), opens up the possibility for extensive analysis, including the following: Open connections or cable and connecter faults Wrong connections (e.g. input to input or output to output) Frequency and 3G protocol mismatch Non-compatible device connection Using the available data, the operations and maintenance center can generate a fault location report, complete with device/connector/cable location color coded on a port map, before sending staff to the site. This can save time and reduce maintenance costs. The system can detect faults when they occur, in real time, so the down time associated with connector damage is reduced, and operational costs remain low.

Debug of failing connector/cable Figure 17 Debug of failing connector/cable First scan sequence Second scan sequence Fault location From the responses or non-responses of secondary devices, primary can infer (port_2) and (port_0) are open. By checking the intended connection reference, the operation s and maintenance center can infer the location of a failing connecter/cable Figure 17 Figure 17 Debug of failing connector/cable Port and device sequence In this example, when a new sequence starts, the scanner looks for the last non-completed device and the next port in the incremental order. The sequence of this scan is not important. If the device is capable of repeater mode connection, following a particular port and device sequence will trace all connections. At minimum, There should be vertical repeater mode connections at every port and horizontal repeater mode connections at various levels. This makes it possible to access all nodes from either side, so fault location can be predicted more accurately. The scan procedure adds very little software overhead to the ALD. Most of the procedure and analysis happens on the side. Site Scan can be supported in the ALD with the additional of a few resources. In most cases, existing processors and their associated resources are adequate for implementing Site Scan.

Simplified flow diagram for Site Scan procedure Figure 18 Simplified flow diagram for Site Scan procedure Scan Start device = last detected device get_connected_port port++ Scan all ports. Update connectivity Got Response? NO Connectivity status update Run diagnostics Port access possible? NO Send Alarm Wait for repeat mode complete Stop Evaluate and connectivity status update All port, All device complete? NO Figure 18 Figure 18 Simplified flow diagram for Site Scan procedure

Disadvantages Implementing Site Scan requires additional commands, responses, and procedures at the and additional command support at each ALD. Insertion of modems at each port also increases the RF insertion loss. Conclusion Site Scan is a simple but reliable procedure for retrieving information about base station connectivity from a remote location. With this procedure extended to full-scale cellular base stations, the operations and maintenance center can gather details that are useful for debug and analysis, including interconnections, components, device parameters, and environment. Implementing such a system is non-trivial and involves a number of intermediate steps. The procedure is suitable for use as an standard. About the author Jaijith Radhakrishnan is a senior architect at NXP Semiconductors and acts as one of NXP s representatives in the standardization group. As lead architect Jaijith is involved in the development of NXP s products and system architecture. Related links Product pages http://www.nxp.com/products/interface_and_connectivity/aisg_transceivers_and_controllers/ Leaflet ASC30xx http://www.nxp.com/documents/leaflet/75017403.pdf Leaflet ASC31xx http://www.nxp.com/documents/leaflet/75017404.pdf

NXP is a member of Antenna Interface Standards Group www.nxp.com 2013 NXP Semiconductors N.V. All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. Date of release: March 2013 Document order number: 9397 757400 Printed in the Netherlands