PRILINK PRI Management System



Similar documents
Internet-bridge XPort

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Self Help Guide IMPORTANT! Configuring Your Router With Your Modem. Please read the following carefully; This Guide refers to the following Products:

xpico User Guide Part Number Revision A April 2012

UDS1100 User Guide Part Number Revision B June 2006

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Internet Access to a DVR365

XPort Device Server User Guide

Linksys Gateway SPA2100-SU Manual

xdirect User Guide Part Number R Revision A September 2012

User Manual Network Interface

Broadband Router ESG-103. User s Guide

Digicom Remote Control for the SRT

UDS10 UDS100 User Guide

Multi-Homing Dual WAN Firewall Router

WEB CONFIGURATION. Configuring and monitoring your VIP-101T from web browser. PLANET VIP-101T Web Configuration Guide

Connecting the DG-102S VoIP Gateway to your network

Ultra Thin Client TC-401 TC-402. Users s Guide

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)

Iridium Extreme TM Satellite Phone. Data Services Manual

Using a simple crossover RJ45 cable, you can directly connect your Dexter to any computer.

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

Chapter 2 Preparing Your Network

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

1. Hardware Installation

ReadMe File. Installing the Unified Messaging Application for

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

CANON FAX L360 SOFTWARE MANUAL

NXT Controller Manual IP Assignment in WAN Environments Application Note

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Metasys System Direct Connection and Dial-Up Connection Application Note

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

IP SERIAL DEVICE SERVER

T3 Mux M13 Multiplexer

Talk2M ewon Internet Connection How To

Quick Installation Guide Network Management Card

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Prestige 623R-T. Quick Start Guide. ADSL Dual-link Router. Version 3.40

One Port Serial Server Users Manual Model ESP901, ESP901E

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

Chapter 1 Configuring Basic Connectivity

NetComm V90 VoIP Phone Quick Start Guide Draft Release 0.1

Lab 2 - Basic Router Configuration

Ethernet Radio Configuration Guide

1 PC to WX64 direction connection with crossover cable or hub/switch

Allworx OfficeSafe Operations Guide Release 6.0

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

CHANGE NETWORK SETTINGS Technicolor TG582n

FINS Gateway For OMRON PLCs

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

BR Load Balancing Router. Manual

GV-Data Capture V3 Series User's Manual

Load Balancer LB-2. User s Guide

Prestige 650R-31/33 Read Me First

EMG Ethernet Modbus Gateway User Manual

HP-1000 Powerline USB Adapter

HP-1000 Powerline Ethernet Adapter

How To Remotely View Your Security Cameras Through An Ezwatch Pro Dvr/Camera Server On A Pc Or Ipod (For A Small Charge) On A Network (For An Extra $20) On Your Computer Or Ipo (For Free

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

UDS2100 Quick Start Guide

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Networking Guide Redwood Manager 3.0 August 2013

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Chapter 15: Advanced Networks

Liebert IntelliSlot Web Cards

3.5 EXTERNAL NETWORK HDD. User s Manual

SOP085 - HELLER OVEN SOFTWARE INSTALLATION PROCEDURE. For version 6.2.x.x

How To Set Up A Computer With A Network Connection On A Cdrom 2.5 (For A Pc) Or Ipad (For Mac) On A Pc Or Mac Or Ipa (For Pc) On An Ipad Or Ipro (

Installing the Microsoft Network Driver Interface

Load Balancing Router. User s Guide

Palomar College Dial-up Remote Access

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

MODBUS TCP to RTU/ASCII Gateway. User s Manual

DVQ-2, DMR8RT, DMR16RT QUICK-START GUIDE

Wireless G Broadband quick install

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

Updating MNS-BB CUSTOMER SUPPORT INFORMATION PK012906

Device Installer User Guide

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

LevelOne VOI H.323 VoIP Gatekeeper. User Manual

How to Remotely View Security Cameras Using the Internet

Windows Dial Up Networking (DUN) for AirLink Modems Application Note - How To

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

Prestige 314 Read Me First

Linksys WAP300N. User Guide

Supporting Multiple Firewalled Subnets on SonicOS Enhanced

Self Help Guide. Please read the following carefully; Synopsis: Requirements: A Computer with a working RJ45 LAN Port All Belkin Modem Routers

Configuration Manual English version

Configuring WAN Failover & Load-Balancing

your Gateway Windows network installationguide b wireless series Router model WBR-100 Configuring Installing

Chapter 1 Configuring Internet Connectivity

P-660R-T1/T3 v2 Quick Start Guide

How to deploy console cable to connect WIAS-3200N and PC, to reset setting or check status via console

Setting Up Your FTP Server

How to setup PPTP VPN connection with DI-804HV or DI-808HV using Windows PPTP client

SecureLinx Spider Duo Quick Start Guide

Keri USB-A Connection and Configuration

Transcription:

www.prilink.com PRILINK PRI MANAGEMENT SSTEM INSTALLATION GUIDE PRI Management PRILINK PRI Management System Installation Guide Version 3.0, Rev. 12-01-24 Page 1

Table of Contents 1 HARDWARE INSTALLATION... 3 1.1 CONNECTING TO ISDN-PRI NETWORKS... 4 1.2 PROFILE... 5 2 LAN SETUP... 7 2.1 DEFAULT SETTINGS... 9 3 SOFTWARE INSTALLATION... 10 3.1 NEW INSTALLATION... 10 3.2 SOFTWARE UPGRADES... 10 Version 3.0, Rev. 12-01-24 Page 2

1 Hardware Installation A Prilink hardware unit collects and analyzes traffic data by monitoring PRI Data Channels (D- Channels) through its 8 monitor ports. COM1: RS-232 serial port provides dial-up access to the unit through an attached external modem. The unit can also be connected directly to the COM port of a PC through null modem cable. LAN: RJ-45 jack provides access to the unit through Ethernet LAN. Transmit monitor jack Receive monitor jack A Bantam-RJ45 Adapter interfaces the Prilink hardware unit to a D-channel via monitor jacks on vendor equipment. A T1/E1 bridge adapter interfaces the Prilink unit to a D-channel when monitor jacks are unavailable. The T1/E1 circuit must be momentarily de-activated while the bridge is installed. Version 3.0, Rev. 12-01-24 Page 3

1.1 Connecting to PRI Networks In this manual the term PRI is used to refer to a group of T1/E1 circuits controlled by the same D-channel. In general, a PRI may consist of a single T1/E1 controlled by a dedicated D-channel, or a group of up to 32 T1s/E1s controlled by a Primary and Secondary D-channel. Signaling on a PRI network is handled in three basic ways: 1) Facility-associated signaling (FAS): Each T1/E1 is controlled by a dedicated D-Channel. Prilink must interface with each T1/E1 using FAS in order to monitor the traffic carried on it. PriLink Carrier Ex. 1 4 independent T1s. Each T1 carries a D-Channel. 2) Nonfacility-associated simplex signaling (NFAS simplex): A group of T1s/E1s are controlled by a single D-channel. Prilink must interface with the T1/E1 carrying the D-channel in order to monitor traffic over the whole group. T1 carrying D-Ch PriLink Carrier Ex. 2 4 T1s in a NFAS simplex group. Only one T1 carries a D- channel. 3) Nonfacility-associated duplex signaling (NFAS duplex): Similar to NFAS simplex, except that a second T1 in the group also has a D-Channel. This is a backup D-Channel, which remains in a standby state until the active D-Channel fails. The two D-Channels are termed Primary and Secondary. Prilink must interface with the active D-channel in order to monitor traffic over the whole group. Since the active D-channel may switch from Primary to Secondary, Prilink needs to interface with both to guarantee complete capture of network traffic. Secondary D-Ch Primary D-Ch PriLink Carrier Ex. 3 4 T1s in a NFAS duplex group. Two of the T1s carry D- Channels. *Important* : Failure to connect the Secondary D-channel to the Prilink base unit s monitor port will result in an inability to monitor traffic in the event of a Primary D-channel failover to the backup Secondary D-Channel. The Primary and Secondary D-Channels are carried on two different T1/E1 lines. ou must identify both before connecting the Prilink base unit. Version 3.0, Rev. 12-01-24 Page 4

Each base unit can connect to up to 8 independent T1/E1 lines using FAS, or 8 independent NFAS simplex groups, or 4 independent NFAS duplex groups. Combinations of FAS and NFAS groups are also possible. The figure below illustrates one such combination: Example 4. Carrier A 5 independent T1 lines using FAS. Monitored on ports 3 thru 7. T1 carrying D-Ch Carrier B Multiple T1 lines in an NFAS simplex group. Monitored on port 2. Primary D-Ch Secondary D-Ch Multiple T1 lines in an NFAS duplex group. Monitored on ports 0-1. 1.2 Profile In Example 4 above, ports 2 7 are monitoring independent D-Channels, while ports 0 1 are monitoring a Primary/Secondary D-Channel pair. In order to interpret data correctly, the Prilink unit must be aware of which ports are monitoring independent D-Channels, and which are monitoring Primary and Secondary D-Channels for the same NFAS group. All combinations of PRI which can be connected to a single Prilink unit fall into one of five different Profiles. All five Profiles are listed in the table below: Version 3.0, Rev. 12-01-24 Page 5

Profile Port 0 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 1. (Example 1 and 2) Pri Pri Pri Pri Pri Pri Pri Pri 2. (Example 3 and 4) Pri / Sec Pri Pri Pri Pri Pri Pri 3. Pri / Sec Pri / Sec Pri Pri Pri Pri 4. (Example 5) Pri / Sec Pri / Sec Pri / Sec Pri Pri 5. Pri / Sec Pri / Sec Pri / Sec Pri / Sec Pri = Independent D-Channel (FAS or NFAS simplex group) or empty Pri / Sec = Primary/Secondary D-Channel pair (NFAS duplex) Connect the Prilink unit in accordance with one of the five Profiles listed above, and make a note of the Profile used (this will be needed when configuring the unit through the client software, see section 2.1 of the User Guide Setting the Profile ). Example 5. Three independent NFAS duplex groups Primary D-Ch Secondary D-Ch Primary D-Ch Secondary D-Ch Carrier Primary D-Ch Secondary D-Ch Version 3.0, Rev. 12-01-24 Page 6

2 LAN setup For network access, the Prilink unit must be assigned a static IP address. To assign an IP address for the first time, perform the following steps: 1) Identify an available static IP address that is not in use by any other device on your network. 2) Note the MAC Address of the PriLink unit, printed on the label directly above the LAN port (it has the form XX-XX-XX-XX-XX-XX). 3) Select a Windows based host from which to assign an IP address to the PriLink unit. Note: ou will not be able to assign an IP address across routers or gateways, so this host must connected to the same subnet. 4) Open a command prompt (Start Run Enter cmd and hit OK). 5) Enter the following to create an entry in the host s ARP table: > arp -s xxx.xxx.xxx.xxx XX-XX-XX-XX-XX-XX 6) Open a Telnet connection on port 1: > telnet xxx.xxx.xxx.xxx 1 The connection will fail quickly, but the unit has temporarily assigned itself the indicated IP address. 7) Open a Telnet Connection on port 9999: > telnet xxx.xxx.xxx.xxx 9999 Press enter within 5 seconds to go into Setup Mode. 8) Select Option 0 Server. IP Address MAC Address 9) Enter the IP Address, Gateway and Netmask. For Netmask, consult the table below to determine the number of bits for host part. Netmask Host Bits Netmask Host Bits Netmask Host Bits Netmask Host Bits 128.0.0.0 31 255.128.0.0 23 255.255.128.0 15 255.255.255.128 7 192.0.0.0 30 255.192.0.0 22 255.255.192.0 14 255.255.255.192 6 224.0.0.0 29 255.224.0.0 21 255.255.224.0 13 255.255.255.224 5 240.0.0.0 28 255.240.0.0 20 255.255.240.0 12 255.255.255.240 4 248.0.0.0 27 255.248.0.0 19 255.255.248.0 11 255.255.255.248 3 252.0.0.0 26 255.252.0.0 18 255.255.252.0 10 255.255.255.252 2 254.0.0.0 25 255.254.0.0 17 255.255.254.0 9 255.255.255.254 1 255.0.0.0 24 255.255.0.0 16 255.255.255.0 8 255.255.255.255 0 Version 3.0, Rev. 12-01-24 Page 7

10) Select Option 9 Save Settings and Exit. Steps 7-10 can be used at any time to change the IP address of the unit, although repeating steps 1-10 will also work (and may be required if the original IP address has been forgotten). Version 3.0, Rev. 12-01-24 Page 8

2.1 Default Settings In Setup Mode (telnet 9999) there are several configurations options. Edit only option 0 Server to assign an IP address. All other options should be left at their default values. 1. Channel 1 5. Expert Baudrate 115200 I/F Mode 4C Flow 02 Port No 3001 ConnectMode Send '+++' in Modem Mode Show IP after RING Auto increment source port C0 Remote IP Address 000.000.000.000 Remote Port 0 DisConnMode 00 FlushMode 22 DisConnTime 00:00 N SendChar 1 00 SendChar 2 00 Ethernet connection type values: 0 = Auto-negotiation 2 = 10Mbit / half duplex 3 = 10Mbit / full duplex 4 = 100Mbit / half duplex 5 = 100Mbit / full duplex TCP Keepalive time in s 45 ARP Cache timeout in s 600 CPU Performance 0 Disable Monitor Mode @ bootup N RS485 tx enable active level 0 HTTP Port Number 80 SMTP Port Number 25 MTU Size 1400 Enable Alternate MAC N Ethernet connection type 5 6. Security Disable SNMP Disable Telnet Setup Disable TFTP Firmware Update Disable Port 77FEh Disable Web Server Disable Web Setup Disable ECHO ports Enable Enhanced Password Disable Port 77F0h N N Version 3.0, Rev. 12-01-24 Page 9

3 Software Installation A Prilink base unit can be accessed by users running PrilinkII Application software on a Windows based PC. In order to access the unit, the PC must have the following: PrilinkII application software installed Valid software key matching the software license number, connected to either the parallel printer port or USB port. One (or more) of the following: - Ethernet connection, with access to the IP address assigned to a base unit. - Modem, with dial-up access to a base unit with external modem. - Direct connection to a base unit via serial cable 3.1 New Installation When installing PriLinkII software for the first time, log on to the Windows based PC with administrator privileges. Perform the following steps: 1) Insert software DVD into the DVD drive. 2) Run setup.exe from the DVD. Do not change the default installation directory; simply click on the icon to begin setup. 3) Once Setup is complete, run the following command from the Windows Start button (for Windows XP, click Start -> Run to bring up the Run pop-up window): C:\prilinkii\haspdinst.exe -i Wait for Operation successfully completed message. 4) Reboot PC. 5) Insert the software key into the parallel or USB port of the PC. 3.2 Software Upgrades If an older version of PriLinkII software is installed on the PC, perform the following steps to install a newer version: (Users must be logged in with administrator privileges.) 1) Back up the following files (if they exist) from your c:\prilinkii\ directory to a temporary directory: i. SiteConfig.fil ii. emsetup.fil (not available in some older versions) iii. setup.fil 2) Using control panel Add/Remove programs, remove all old version of PriLinkII software. 3) Insert the software DVD into the DVD drive. 4) Run setup.exe from the DVD. Do not change the default installation directory, simply click on the icon to begin setup. 5) Once setup is complete, run the following command from the Windows Start button (for Windows XP, click Start -> Run to bring up the Run pop-up window): Version 3.0, Rev. 12-01-24 Page 10

i. C:\prilinkii\haspdinst.exe fr kp -purge Wait for Operation successfully completed Disconnect software key if it is currently connected. ii. C:\prilinkii\haspdinst.exe i Wait for Operation successfully completed 6) Reboot PC. 7) Insert the software key into the parallel or USB port of the PC. 8) Move the files copied to a temporary directory in step 1 back into c:\prilinkii\. Overwrite the existing versions. If PrilinkII software has been installed properly, the application should be accessible through Start Programs PrilinkII. (Version and Software License Number) The Main Application Menu Bar is shown on the left, which is the access point to all of PrilinkII s rich set of features. Please consult the Prilink User Guide for detailed documentation on each of these features. Version 3.0, Rev. 12-01-24 Page 11