NQTMVS GENERAL INFORMATION. heading text INSTALLATION SERVICE PAGE 1» SECTION MARKER SUB-HEADING. Body Text



Similar documents
Approved courses for licences and licence endorsements detailed in the Plumbing and Drainage Regulation 2003 (Qld) Licences

it has to be Hindmarsh for Service Excellence

STANDARD OPERATING PROCEDURE EMERGENCY EYEWASH AND SHOWER EQUIPMENT

Design Requirements for Eyewash and Safety Shower Units APPLICATION: Detailed Installation, Operation and Design. Eyewash Stations.

RTC - HB SAFETY & SECURITY FEATURES

CAPABILITY STATEMENT

Cross Connection Control and Backflow Prevention Program Guidelines

FIND IT! FIX IT! REPORT IT! Resolving Water Loss Claims

Notifiable work. A guide for plumbers and drainers. October Building Codes Queensland Department of Housing and Public Works

Plumbing Code of Australia

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

FIRING RANGE PHASE 1 DESIGN

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

water regulation facts The Water Supply Regulations The Water Supply (Water Fittings) Regulations 1999 What are they, and how do they affect you?

Australian/New Zealand Standard

Plumbing. thegordon.edu.au #thegordon #thegordon

Laboratory Facility Cleaning and Maintenance Guidelines

15430 SAFETY SHOWERS AND EYEWASHES

AMX300 DirectConnect Mixing Valve Kits

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

SAMPLE INSPECTION REPORT PREPARED FOR: John Q Public

How Compliant is Your Emergency Shower and Eyewash? What Managers Need to Consider about Australian Standard Compliance

Frequently asked Questions about Drinking Water Supply.

CHAPTER 26 PLUMBING CODE

EMERGENCY EYEWASH & SHOWER EQUIPMENT SELECTION, INSTALLATION & USE GUIDE

COMPREHENSIVE DRINKING WATER SOURCE-TO-TAP ASSESSMENT GUIDELINE

Queensland PLUMBING AND DRAINAGE ACT 2002

WHITE OAK BEND MUD Jones Rd, Suite 120, Houston, Texas Phone Number (281)

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Emergency Showers and Eyewash Stations

Control of legionella bacteria in water systems

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

EMERGENCY PLUMBING FIXTURES

EMERGENCY RESPONSE PLAN

How To Reduce Lead Content In Plumbing

6. Principles of effective plumbing systems

EVENT APPLICATION FORM MAJOR EVENT (Over 50 Attendees)

Construction Crafts: Plumbing of Sanitary Appliances (Intermediate 2)

Standard terms and conditions

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

LIVING VICTORIA WATER REBATE PROGRAM 1 JULY 2012 TO 30 JUNE 2015 FOR UP TO 50 EMPLOYEES. Small Business

Simplified Service Plan

Event Management Guidelines. Month Event Management Guidelines (Month, 2011)

Subordinate Local Law No (Operation of Temporary Entertainment Events) 2015

A Guide to the SPILL CONTINGENCY PLANNING AND REPORTING REGULATIONS

B. Shop Drawings: Diagram power, signal, and control wiring.

SafetyMAP Initial Level User Guide

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Food safety checklist How well does your food business rate?

Facilities Maintenance Standards rev

INDUSTRIAL REFRIGERATION & AIRCONDITIONING. Company Profile

AMOUNT New Account Deposit $50.00 Service Delinquent $10.00 Delinquency Notification $15.00 NSF Check processing $20.00

Bruce Gerald Flint. Liability limited by a Scheme approved under Professional Standards Legislation

EMERGENCY SHOWERS AND EYEWASH STATIONS

Additional Services Agreement. Part 3: Schedule of our requirements

How to Protect Your Property Against Plumbing Disasters

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

VILLAGE OF GRANVILLE SEWER BACK-UP and WATER LEAK POLICIES

The Plumbing Pipeline

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

POLLUTION INCIDENT RESPONSE MANAGEMENT PLAN

Townsville City Council Environmental Health Services

Gas Fired Water Heater Installation

ASSET SERVICES Your facility. Our responsibility.

Number September 2014 SEWER LIABILITY

Page 1 of 51 Exterior Plumbing Quiz Part 1

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

INSTALLATION INSTRUCTIONS BL-8704

Premier Plumbing & Gas

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Regional Council of Goyder

ANNEXURE TO Australian Standard Minor Works Contract Conditions (Superintendent Administered) AS Part A

INSTALLATION INSTRUCTIONS MK-8704

WORK HEALTH AND SAFETY CONSULTATION, CO-OPERATION AND CO-ORDINATION

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

Pollution Incident Response Management Plan (PIRMP)

ONSITE TRACK EASY NCIG Contractor Management Portal Portal User Guide: Company Registration.

Assessment modules. Australian Government Australian Aged Care Quality Agency.

ENVIRONMENTAL HEALTH FACT SHEET NO. 500

Hancock County Combined General Health District Plumbing Regulations

Making Your Home Ready For Solar Water Heating

Transcription:

NQTMVS INSTALLATION SERVICE heading text SUB-HEADING Body Text PAGE 1» SECTION MARKER GENERAL INFORMATION

table of contents The Company Device Testing & Certification» Thermostatic Mixing Valves» Backflow Prevention Devices» Emergency Eye Wash and Shower Equipment Licences and Certificates Contact Us 2 3 4 5 6 7 PAGE 1» TABLE OF CONTENTS

testing and certification the company NQTMVS SUB-HEADING is a privately owned licenced plumbing company who specialise in the installation, maintenance, replacement and repair of Thermostatic Mixing Valves, Backflow Prevention Devices and Emergency Eye Wash/Shower Equipment. We service over 3000 devices annually throughout Australia and are committed to professional, competent service to ensure your complete satisfaction. We offer a full service in all aspects of Thermostatic Mixing Valves and other plumbing services including: Free on-site analysis Competitive Fees Installation and service of all makes and models of Thermostatic Mixing Valves, Backflow Prevention Devices and Emergency Eye Wash and Shower Equipment Certificates for all testing/commissioning results in electronic format Electronic notification of next scheduled service call, 4 weeks prior to due date We are supported by: $20 million of public liability insurance cover All our staff hold current Federal Police checks BSA Trade Contractors Licence Thermostatic Mixing Valve Licence Certification Backflow Licence Certification Plumbers Licence Certification Compliance with Australian Standard 4032 Commissioning Maintenance and Installation for Thermostatic Mixing Valves THERMOSTATIC MIXING VALVES WHAT IS A THERMOSTATIC MIXING VALVE (TMV)? A Thermostatic Mixing Valve is a device that delivers a mix of hot and cold water to showers and basins that ensure safe and constant temperatures are delivered at the water outlet to prevent scalding injuries. SUB-HEADING WHY DO TMVS REQUIRE TESTING AND HOW FREQUENTLY IS TESTING REQUIRED? It is a mandatory requirement that all TMVs are tested and certified to ensure correct working order is maintained. TMVs are required to be tested annually and this is legislated in the Australian National Standard AS4032.3 2004. WHO IS ABLE TO SERVICE A TMV? Only a TMV accredited licensed plumber can service Thermostatic Mixing Valves. MANAGING THE ANNUAL TESTING OF TMVS: Thermostatic Actuators and Dynamic O Rings and Seals are required to be changed every 5 years, or, as prescribed by the manufacturer. All certificates and valve registers should be saved as a PDF file for ease of access. NQTVMS SERVICES: We provide you with a PDF service certificate of your Thermostatic Mixing Valve, including a valve register. Clients will also receive a full PDF copy of our license certificates, insurance policies and Federal police checks for their accreditation requirements. Our system is fully automated to send out a friendly reminder a month prior to your next annual service. PAGE 2» THE COMPANY PAGE 3» TESTING AND CERTIFICATION

BACKFLOW PREVENTION DEVICES EMERGENCY EYE WASH AND SHOWER EQUIPMENT WHAT IS A BACKFLOW PREVENTION DEVICE? A Backflow Prevention Device is used to prevent the water supply from being contaminated by stopping water in a non-potable main from flowing back into the drinking water main. WHAT IS AN EMERGENCY EYE WASH / SHOWER? The purpose of an Emergency Eye Wash / Shower station is to enable immediate and critical response to incidents involving persons exposed to hazardous substances. WHY DO BACKFLOW PREVENTION DEVICES REQUIRE TESTING AND HOW FREQUENTLY IS TESTING REQUIRED? It is a mandatory requirement from all local council authorities throughout Australia that all Backflow Prevention Devices are tested and certified to ensure correct working order. Service certificates must be forwarded to local authorities every 12 months as per the Australian National Standard AS2845.3 2010. WHO IS ABLE TO SERVICE A BACKFLOW PREVENTION DEVICE? Only a Backflow accredited licensed plumber can service Backflow Prevention Devices. MANAGING THE ANNUAL TESTING OF BACKFLOW PREVENTION DEVICES: All certificates and device registers should be saved as a PDF file for ease of access. NQTVMS SERVICES: We provide you with a PDF service certificate of your Backflow Prevention Device, including a device register. Clients will also receive a full PDF copy of our license certificates, insurance policies and Federal police checks for their accreditation requirements. Our system is fully automated to send out a friendly reminder a month prior to your next annual service. WHY DOES EMERGENCY EYE WASH / SHOWER EQUIPMENT REQUIRE TESTING AND HOW FREQUENTLY IS IT REQUIRED? It is a mandatory requirement that all Emergency Eye Wash / Shower Equipment be tested and certified to ensure that the devices supply clean potable water at all times and are in correct working order. Emergency Eye Wash / Shower Equipment should be tested and certified every 12 months as per the Australian National Standard AS4775 2007. WHO IS ABLE TO TEST AN EMERGENCY EYE WASH / SHOWER? Weekly: Facility staff members Annually: Technician familiar with the testing procedures as per AS4775 2007. MANAGING THE ANNUAL TESTING OF EMERGENCY EYE WASH / SHOWER EQUIPMENT: All certificates and device registers should be saved as a PDF for ease of access. NQTVMS SERVICES: We provide you with a PDF service certificate of your Emergency Eye Wash / Shower Equipment, including a device register. Clients will also receive a full PDF copy of our license certificates, insurance policies and Federal police checks for their accreditation requirements. Our system is fully automated to send out a friendly reminder a month prior to your next annual service. PAGE 4» TESTING AND CERTIFICATION PAGE 5» TESTING AND CERTIFICATION

LICENCES SUB-HEADING Plumber s Licence Drainer s Licence Thermostatic Mixing Valve Licence Backflow Prevention Licence BSA Trade Contractor s Licence NUMBER 42971 $20 Million Public Liability Insurance Cover ABN: 67 579 508 918 CERTIFICATES National Police Certificate Bluecard (working with children) Note: Copies of all relevant licences, policies and certificates will be provided to clients. PAGE 6» LICENCES & CERTIFICATES

contact us Please contact Gordon on the following: MOBILE: E-MAIL: WEBSITE: ADDRESS: 0488 (NQTMVS) 0488 678 687 gordon@nqtmvs.com.au www.nqtmvs.com.au P.O Box 488 Townsville QLD 4810