JUMO tecline HD ph and JUMO tecline HD Rd



Similar documents
JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Digital inductive conductivity transmitter

Combination ph/redox (ORP) Sensors

Portable digital microprocessor thermometers with interchangeable probes

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Compact ph Measuring Instruments

ph, redox and I.S.E. electrodes

RTD Temperature Probe for the Food/Pharmaceutical Industry

HND-R. Hand-held ph, Redox and Temperature Measuring Units

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

SenTix 950 SenTix 980

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Conductive Level Switch FK 2 Technical Data:

ph Measurement and Control

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Certificate: / 20 August 2013

Digital input modules

Highly efficient flue gas analyzer

Certificate: _01 / 29 April 2014

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

How To Use A Corona Mdi 110

Reaction Torque Sensor

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Plastic tube flowmeters Series PT/PS

SITRANS F flowmeters SITRANS F M

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

General Purpose ph/orp Sensors

DISSOLVED OXYGEN PROBE

Dissolved Oxygen Sensors

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Test equipment for temperature and its reduction

How To Use A Flowmeter

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

S300 Series Dust Monitors

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Measurement by Ion Selective Electrodes

Pressure switches for gas and air Pressure sensors

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Hose and Tube Fittings Series 1-3

Duct Humidity Transmitter

High pressure reactors Where are your limits?

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

USEPA Electrode Method Method 8156

Expertise in liquid analysis From sensors to complete turnkey solutions

Safety at a high level!

Relative and absolute pressure switch type 529

Milwaukee USER MANUAL

PN /rev. D December Theory and Practice of ph Measurement

AE PV Heating Element. Screwing in Heating Unit. Installation Manual. Version 01.7

Vacuum drying oven for non-flammable solvents

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Assisted lift operated 2/2-way solenoid valves Type EV250B

Instruction Manual. Model FU20 ph/orp Combination sensor. IM 12B6J3-02E-E 7th edition

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

kymanual or Automatic - it s your Choice

A Potentiometric Analysis of Fluoride Ion in Toothpaste

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

Stainless steel process fittings

Self-operated Temperature Regulators Temperature Regulator Type 1u

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Turbine Flow Sensor Series VTR

Cables. Accessories. For Force, Torque and Strain Sensors

Typical Aluminum GFM Mass Flow Meter

2/2 and 3/2 Way Size 6 Seat Valves

ph/redox Measurement MyPro CPM 431

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Centricut plasma torches and consumables for ESAB

5SV Residual Current Protective Devices

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

The Theory of ph Measurement

Pneumatic actuators The Original! Technics of the top class.

white paper reviews why the chlor-alkali process is so damaging to ph electrodes and discusses a sensor design that has

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

LED...A Q Series Sealed High-Intensity

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Rotary actuators Rotary wing drives Series RAK. Brochure

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Richter Twin Piston Quarter-turn Actuators

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Specials. designed. 3rd edition 2015 English. for scientists 1

General Purpose ph/orp Sensor

DISSOLVED OXYGEN METER Model : DO-5509

VDL 53 - Vacuum drying oven for flammable solvents

Incubator with mechanical convection

Gas Sample Probe Series SP

System 8. ü ( System 8

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Drop Counter Sensor Product Number: ENDRP-AD100

Explosion proof enclosures

CSF16 and CSF16T Stainless Steel Steam Filters

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

ALMATEC Series CX CX 10 CX 130

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

Transcription:

Page 1/7 JUMO tecline HD ph and JUMO tecline HD Rd ph and redox combination electrodes in glass shaft version Series 201021 ph electrodes Series 201026 redox electrodes Brief description JUMO tecline HD electrodes are high-quality sensors for highly demanding applications in process and industrial measurement technology. The electrodes benefit from the use of high-quality materials and components. They take the form of combination electrodes (glass or metal electrode and a reference electrode in one shaft). A temperature probe can also be integrated as an option, depending on the type. JUMO tecline HD sensors represent the state of the art in modern ph and redox electrodes. Each top-quality electrode is individually tested and supplied with a calibration certificate. Modern production facilities ensure consistent characteristics. General information on the design of the JUMO tecline HD series: All standard electrodes are manufactured using physiologically safe and FDA-listed materials. The sensors feature lead-free shaft glass and therefore comply with the RoHS-2 directive. Type 201021/10... Typical areas of application Chemical industry: Process water, high process pressures up to 13 bar, broad temperature range up to 135 C and wide ph range from ph 0 to ph 14 Industrial wastewater engineering: Process wastewater, wastewater with highly contaminating media (presence of oil or electrode poisons) Electroplating: Process water, media with electrode poisons (metal ions, complexing agents) Power stations and waste incineration plants (flue gas scrubbing): Wide ph range of ph 0 to ph 14, presence of fine ash particles Sugar industry: Constantly high temperature, presence of electrode poisons (such as sulfides) Special features Low-maintenance thanks to dirt-repellant PTFE ring diaphragm with polymerized highly elastic gel Designed for use at continually high process temperature of up to 135 C (13 bar) Pt1000 temperature probe can be integrated as an option With salt reserve to increase service life in media with low conductivity Long service life with presence of electrode poisons thanks to double-chamber version Redox versions with platinum or gold tip up to ±2000 mv

Page 2/7 Technical data Specifications Measurands ph-value Temperature (optional) Measuring range 0 to 14 ph Temperature range 0 to 135 C Ambient conditions Storage temperature -5 to +30 C Protection type N plug head (S8) IP68 Variopin (VP) plug head IP68 Process conditions Process temperature 0 to +135 C Process pressure 13 bar Pressure-temperature diagram Recommended minimum conductivity 50 µs/cm Design Process connection Pg13.5 Temperature sensor Pt1000 (class A) Plug heads N plug head (S8), Pg13.5 thread Variopin (VP) plug head, Pg13.5 thread Reference system Pressure-compensated double-chamber system, silver/silver chloride (Ag/AgCl) cartridge-style conduction system, highly elastic gel (AgCl-free) Diaphragm Exterior PTFE ring diaphragm Interior Ceramic diaphragm a Glass membrane Membrane glass Spherical High-temperature (HT) glass Materials See illustrations in Chapter Dimensions, page 4 a In double chamber

Page 3/7 Special design features Salt reserve The electrode is equipped as standard with a salt reserve in the form of four salt rings (see illustration). This makes it particularly well suited to use in low-ion media or at high flow rates. The salt reserve helps to improve the service life of the electrode. Double chamber If electrode poisons such as sulfides are present in the measurement medium, the extended diffusion path (due to the two consecutive chambers double chamber system) and the double diaphragm separation prevent electrode poisoning. The rings are not a manufacturing defect (crystallization). (1) Salt reserve (2) Double chamber

Page 4/7 Dimensions Type 201021/10... (1) Screw head Pg13.5 (max. tightening toque 3 Nm) (2) Thread Tr12.7 3 P1.5 (3) Ring (PSU) (4) O-ring 10 3.5 (FPM70) (5) Electrode shaft (glass DIN 19263) (6) Ring diaphragm (PTFE) (7) Tip membrane (8) Variopin (VP) plug head connection variant Type 201026/10... (1) Screw head Pg13.5 (max. tightening torque 3 Nm) (2) Thread Tr12.7 3 P1.5 (3) Ring (PSU) (4) O-ring 10 3.5 (FPM70) (5) Electrode shaft (glass DIN 19263) (6) Ring diaphragm (PTFE) (7) Platinum or gold tip

Page 5/7 Order details type 201021 (1) Basic type 201021/10 JUMO tecline HD ph ph combination electrode in glass shaft version, solid gel, double chamber, salt reserve, 13 bar (135 C) (2) Active ph component 12 HT glass (3) Diaphragm 04 PTFE ring (4) Electrical connection 18 With VP plug head Pg13.5 22 Screw head Pg13.5 (S8) (5) Insertion length 120.0 120 mm (standard) 225.0 225 mm (6) Extra code 000 None 841 Integrated Pt1000 (1) (2) (3) (4) (5) (6) Order code - - - - / Order example 201021/10-12 - 04-22 - 120 / 000 Note: The order code is not modular. When placing orders, if possible please select the items listed under "Stock versions" or "Production versions". We must check the technical feasibility of and approve freely chosen combinations of individual code parts.

Page 6/7 Order details type 201026 (1) Basic type 201026/10 JUMO tecline HD Rd Rd combination electrode in glass shaft version, solid gel, double chamber, salt reserve, 135 C, 13 bar (2) Active ph component 22 Pt (platinum) tip 32 Au (gold) tip (3) Diaphragm 04 PTFE ring (4) Electrical connection 22 Screw head Pg13.5 (S8) (5) Insertion length 120.0 120 mm (standard) 225.0 225 mm (6) Extra code 000 None (1) (2) (3) (4) (5) (6) Order code - - - - / Order example 201026/10-22 - 04-22 - 120 / 000 Note: The order code is not modular. When placing orders, if possible please select the items listed under "Stock versions" or "Production versions". We must check the technical feasibility of and approve freely chosen combinations of individual code parts.

Page 7/7 Scope of delivery 1 sensor in the ordered version 1 certificate of quality Stock versions (Delivery within 3 working days after receipt of order) Type Part no. 201021/10-12-04-22-120/000 00621059 201021/10-12-04-18-120/841 00621070 201026/10-22-04-22-120/000 00625340 Accessories Cable Item Cable for sensors with screw head Pg13.5 (S8): 202990/02-92-x-13 Cable for sensors with Variopin (VP) plug head: 202990/11-95-x-11 Solutions Item ph buffer solutions Redox reference solution Electrode cleanser Part no. 202990 202990 Part no. 202950 202950 202950