Serial Adapter Module. Supplement. Part No. 303124-A Rev 01 November 1998. *303124-A Rev 01*



Similar documents
Instruction Manual PC55O. With PC5OORK Keypad. 1996, 2002 Digital Security Controls Ltd. Toronto, Canada Printed in Canada R3

INSTRUCTION MANUAL PC15OO/155O WITH LED615 KEYPAD

First Data FD130 Terminal. Quick Set-up Guide

SILENT KNIGHT 5000 Series

Instruction Manual. version 1.0

Operation Manual Software Version 1.1

Direct AC Wiring Option Installation Guide

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

VS1 Telephone System Installation, Configuration & Operating Guide

Gateway Port Replicator User Guide

Group Videoconferencing Systems

Simon Security System. User Guide. Technical Manuals Online! Rev A June Part No:

Simon Security System. User Guide Rev J May Part No: ZZZ*(,QWHUORJL[FRP. System Status HOME SECURITY. Windows Sensors.

Simon Security System. User Guide Rev H April Part No: ZZZ*(,QWHUORJL[FRP. System Status HOME SECURITY. Windows Sensors.

Simon Security System. User Guide Rev F September Part No: ZZZ*(,QWHUORJL[6HFXULW\FRP. System Status HOME SECURITY

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

Product Documentation on the World Wide Web

UIM-2T1 T1 Loop Bonding Uplink Interface Module

User's Manual 4110DL/4110XM

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

FD200 Ti Terminal. quick Set-Up Guide

WARNING NT9010

PCI Express V.92 56K Internal Data/Fax Modem

Regulatory Compliance Statement

PHONE ACCESS USER'S GUIDE

User's Manual. N7229-4V4 Rev B 4/99

Power Over Ethernet Adapters POE101

FortiFone QuickStart Guide for FON-670i and FON-675i

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

USB Mini Print Server PS121. Installation Guide

Technical Support. Support Information

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Quick Reference Guide

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

User guide. Stereo Bluetooth Headset SBH70

Installation & Operation Instructions

Open Networking Adapter 1101GT Quick Install Guide

AD511 Active Iridium Antenna User Manual Mar 12 V4.0

DIGITAL family of systems Administration Manual

Sun Management Center Change Manager Release Notes

INSTALLATION MANUAL. PC3OOO Version 7.51

TAM Port T1 Access Multiplexer

Hotwire 6310 MVL Modem with Inline Phone Filter Installation Instructions. Contents. Hotwire 6310 MVL Modem Overview

N5100-3V3 9/96. USER'S MANUAL FA120C Security System

About the HotWire Slot Standalone Shelf

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

TNE1500-P and TNE1500-S T1 Network Extenders Installation Instructions

Triple Expansion Chassis

FortiFone QuickStart Guide for FON-370i

Linksys Business Series 24-port Gigabit Ethernet Switch

Installation and Maintenance Manual. Technical Manual - Volume I

Group Videoconferencing Systems

Start Here. Installation and Documentation Reference. Sun StorEdgeTM 6120 Array

Allworx 6x Installation Guide

User guide. Stereo Bluetooth Headset SBH80

FBII Security System. User Guide. N9939V5 4/04 Rev. A

Network Management Card. Installation and Quick Start Manual

MoCA Adapter MC1001 v2 Installation Guide

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

VOICE SECURITY SYSTEM

GSM-EXT Cable Assembly Installation Guide

2.1. Calling Call Time-Out Being Called Conversation Method Substation Priority Level...

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

INVENTEK SYSTEMS ISM34x-USB Embedded Serial-to-WiFi Module es-wifi a/b/g/n, Bluetooth 4.0, NFC

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

Series Installation Guide Internal AC Outlet Option Kit

INSTRUCTION MANUAL PC2525

AMBR AMATIS Border Router

ATA User Manual. iinet ATA Telephone Adapter. Setting up for ADSL and VoIP. For model F1PG200ENau

Network Management Card

Operating Guide Manuel de l utilisateur

IP Phone 1100 User Guide. IP Phone 1110 Business Communications Manager

Digital T1/E1 PCI (HMP) Board

PARTNER. Advanced Communications System Programming and Use

10BASE-T/100BASE-TX & 100BASE-FX 2-Port Bridging Media Converter

ASUS Miracast Dongle E-MANUAL E8741

Read this document before using this product.

16-Port Gigabit Green Switch (TEG-S16Dg) 24-Port Gigabit Green Switch (TEG-S24Dg)

1. Installation Requirements

Polycom CX500/CX600/CX3000 IP Phone User Guide

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

Kvaser Mini PCI Express User s Guide

Operation Instructions PowerCool Series

How To Install A Basler Aviator Gige Camera

Transcription:

Serial Adapter Module Supplement Part No. 303124-A Rev 01 November 1998 *303124-A Rev 01*

4401 Great America Parkway 8 Federal Street Santa Clara, CA 95054 Billerica, MA 01821 Copyright 1998 Bay Networks, Inc. All rights reserved. Printed in the USA. November 1998. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Bay Networks, Inc. Trademarks AN, Optivity, Quick2Config and Bay Networks are registered trademarks and Advanced Remote Node, ANH, ARN, BayRS, BayStack, BCC, and the Bay Networks logo are trademarks of Bay Networks, Inc. All other trademarks and registered trademarks are the property of their respective owners. Statement of Conditions In the interest of improving internal design, operational function, and/or reliability, Bay Networks, Inc. reserves the right to make changes to the products described in this document without notice. Bay Networks, Inc. does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein. USA Requirements Only Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense. European Requirements Only EN 55 022 Statement This is to certify that the Bay Networks <product or system name> is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22). Warning: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take appropriate measures. EC Declaration of Conformity This product conforms (or these products conform) to the provisions of Council Directive 89/336/EEC and 73/23/EEC. The Declaration of Conformity is available on the Bay Networks World Wide Web site at www.baynetworks.com. ii 303124-A Rev 01

Japan/Nippon Requirements Only Voluntary Control Council for Interference (VCCI) Statement Voluntary Control Council for Interference (VCCI) Statement This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus (<product or system name>) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications. Règlement sur le brouillage radioélectrique du ministère des Communications Cet appareil numérique (<product or system name>) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada. Canada CS-03 Rules and Regulations Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent the degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. 303124-A Rev 01 iii

Notice: For equipment using loopstart lines, please note that the Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. The REN is located on the FCC Rules Part 68 label located on the bracket of the module, or on the back of the unit. Canada CS-03 -- Règles et règlements Avis: L'étiquette d'industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, d'exploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n'assure toutefois pas que le matériel fonctionnera à la satisfaction de l'utilisateur. Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée de raccordement. L'abonné ne doit pas oublier qu'il est possible que la conformité aux conditions énoncées ci-dessus n'empêche pas la dégradation du service dans certaines situations. Les réparations de matériel homologué doivent être coordonnées par un représentant désigné par le fournisseur. L'entreprise de télécommunications peut demander à l'utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l'utilisateur ou à cause de mauvais fonctionnement. Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la terre de la source d'énergie électrique, des lignes téléphoniques et des canalisations d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. Avertissement: L'utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à un service d'inspection des installations électriques, ou à un électricien, selon le cas. Avis: Veuillez prendre note que pour tout appareillage supportant des lignes de type loopstart, l'indice d'équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d'une interface téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition que la somme d'indices d'équivalence de la sonnerie de tous les dispositifs n'excède pas 5. Le REN figure sur l étiquette FCC Rules Part 68 située sur le support du module ou à l arrière de l unité. FCC Part 68 Compliance Statement This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68. Please note the following: 1. You are required to request service from the telephone company before you connect the unit to a network. When you request service, you must provide the telephone company with the following data: When you request T1 Service, you must provide the telephone company with -- The Facility Interface Code Provide the telephone company with all the codes below: - 04DU9-BN (1.544 MB, D4 framing format) - 04DU9-DN (1.544 MB, D4 framing format with B8ZF coding) - 04DU9-1KN (1.544 MB, ESF framing format) - 04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding) - 04DU9-1ZN (1.544 MB, ANSI ESF and ZBTSI without line power) The telephone company will select the code it has available. -- The Service Order Code(s) (SOC): 6.0F -- The required Universal Service Order Code (USOC) jack: RJ48C iv 303124-A Rev 01

When you request 56K/64K Service, you must provide the telephone company with -- The Facility Interface Code: 04DU5-56/64 -- The Service Order Code(s) (SOC): 6.0F -- The required Universal Service Order Code (USOC) jack: RJ48S When you request V.34 Service, you must provide the telephone company with -- The required Universal Service Order Code (USOC) jack: RJ11C -- The make, model number, Ringer Equivalence Number (REN), and FCC Registration number of the unit The REN helps you determine the number of devices you can connect to your telephone line and still have all of those devices ring when your number is called. In most, but not all, areas, the sum of the RENs of all devices should not exceed 5.0. To be certain of the number of devices you can connect to your line, you should call your local telephone company to determine the maximum REN for your calling area. This equipment must not be used on party lines or coin lines. When you request ISDN U Interface Service, you must provide the telephone company with -- The Facility Interface Code: 02IS5 -- The Service Order Code(s) (SOC): 6.0F -- The required Universal Service Order Code (USOC) jack: RJ49C When you request ISDN S/T Interface Service, you must provide the telephone company with -- The Service Order Code(s) (SOC): 6.0N -- The make, model number, and FCC Registration number of the NT1 Note: ISDN S/T cannot be directly connected to the network. When you request Primary Rate ISDN Service, you must provide the telephone company with -- The Facility Interface Code: 04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding) -- The Service Order Code(s) (SOC): 6.0F -- The required Universal Service Order Code (USOC) jack: RJ48C 2. Your telephone company may make changes to its facilities, equipment, operations, or procedures that could affect the proper functioning of your equipment. The telephone company will notify you in advance of such changes to give you an opportunity to maintain uninterrupted telephone service. 3. If the unit causes harm to the telephone network, the telephone company may temporarily discontinue your service. If possible, they will notify you in advance, but if advance notice is not practical, you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC. 4. If you experience trouble with the unit, please contact the Bay Networks Technical Solutions Center in your area for service or repairs. Repairs should be performed only by service personnel authorized by Bay Networks, Inc. United States 1-800-2LAN-WAN Valbonne, France 33-4-92-96-69-68 Sydney, Australia 61-2-9927-8800 Tokyo, Japan 81-3-5402-0180 5. You are required to notify the telephone company when you disconnect the unit from the network. 303124-A Rev 01 v

Using the Serial Adapter Module This document supplements one of the following guides: Installing an Adapter Module in a BayStack AN or ANH Router Installing and Operating BayStack ARN Routers (Chapter 4, Installing a WAN Adapter Module ) Follow the hardware installation steps in the guide for your router, referring to this document for information specific to the ARN Serial and AN /ANH Third Synchronous adapter module. Information in this supplement includes: Verifying Router Requirements on page 1 Attaching Cables on page 2 Completing Software Configuration on page 4 Interpreting LEDs on page 4 Verifying Router Requirements Table 1 shows the minimum versions of boot and diagnostic programmable read-only memory (PROM) code required for a serial adapter module. Table 1. PROM Diagnostic and Boot Code for Serial Adapter Module Router Type Code Type Minimum Version Directory File Name ARN Boot 1.17 arn_proms arnboot.exe Diagnostic 1.30 arn_proms arndiag.exe AN/ANH Boot 8.12 an_proms anboot.exe Diagnostic 5.31 an_proms andiag.exe For information on upgrading PROM, see the BayRS Upgrading Routers guide. 303124-A Rev 01 1

Serial Adapter Module Supplement Attaching Cables Connect the communications cable to the 44-pin DSUB connector on the installed adapter module. You install the Serial adapter module in an open adapter module slot on the router, as follows: ARN -- one of the two front-panel WAN adapter module slots (Figure 1). See Installing and Operating BayStack ARN Routers. AN or 12-port ANH -- the back-panel adapter module slot (Figure 2). See Installing an Adapter Module in a BayStack AN or ANH Router. 8-port ANH -- the back-panel COM3 slot (Figure 3). See Installing an Adapter Module in a BayStack AN or ANH Router. ARN front panel 1 U ISDN BRI withnt1 D DD B1 B2 Tx Rx Cl 10BaseT 2 RLSD COM Tx 10BaseT Ethernet 2 Rx Cl Ethernet 1 To RS-232, RS-422, RS-530, V.28, V.35, or X.21 interface ARN0066A Figure 1. ARN Serial Adapter Module Connector (Slot 2) 2 303124-A Rev 01

Using the Serial Adapter Module U L U L XCVR UTP TX RX CL CONSOLE RST RLSD2 CO M 2 RLSD1 COM 1 100-240V 50-60 Hz 1.0-0.5A Third synchronous interface ANH0133A Figure 2. Serial Adapter Module Connector on an AN or 12-Port ANH COM 2 COM 1 COM 3/Expansion Third synchronous interface ANH137A Figure 3. Serial Adapter Module Connector on an 8-Port ANH 303124-A Rev 01 3

Serial Adapter Module Supplement Completing Software Configuration Once you have successfully installed the Serial adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Connect the ARN to the network. Modify the ARN configuration file to add the Serial adapter module and enable default software services. Configure line services. Configure WAN protocol services. Location of Instructions One of the following: Installing and Operating BayStack AN and ANH Routers Installing and Operating BayStack ARN Routers Configuring BayStack Remote Access Any of the following: Configuring and Managing Routers with Site Manager Using the Bay Command Console Configuring Your Router Using the Quick2Config Tool Configuring WAN Line Services Any of the BayRS WAN or System Suite guides, including: Configuring IP Services Configuring Frame Relay Services Configuring X.25 Services Configuring PPP Services Interpreting LEDs For the latest information, be sure to review the Release Notes and Documentation Changes for your version of BayRS software. The Serial adapter module RLSD (Received Line Signal Detection) LED lights when the serial interface detects data transfer. The LED will blink on and off during diagnostic testing, but does not indicate data transfer until you have configured and enabled the software services. 4 303124-A Rev 01