INSTRUCTION MANUAL PC2525
|
|
|
- Bethanie Alexina Mason
- 9 years ago
- Views:
Transcription
1 INSTRUCTION MANUAL PC2525
2 Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company s inside wiring associated with a single line individual service may be extended by means of certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. User should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100. The Load Number of this unit is 2. AVIS: L étiquette du ministère des Communications du Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme à certaines normes de protection, d exploitation et de sécurité des réseaux de télécommunications. Le Ministère n assure toutefois pas que le matériel fonctionnera à la satisfaction de l utilisateur. Avant d installer ce matériel, l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale de télécommunication. Le matériel doit également être installé en suivant une méthod acceptée de raccordement. Dans certains cas, les fils intérieurs de l entreprise utilisés pour un service individuel a ligne unique peuvent être prolongés au moyen d un dispositif homologué de rassordement (cordon prolongateur tèlèphonique interne). L abonné ne doit pas oublier qu il est possible que la conformité aux conditions énoncées ci-dessus n empechent pas la dégradation du service dans certaines situations. Actuellement, les entreprises de télécommunication ne permettent pas que l on raccorde leur matériel a des jacks d abonné, sauf dans les cas précis prévus par les tarrifs particuliers de ces entreprises. Les réparations de matériel homologué doivent etre effectuées par un centre d entretien canadien autorisé désigné par le fournisseur. La compagnie de télécommunications peut demander à l utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l utilisateur ou à cause de mauvais fonctionnement. Pour sa propre protection, l utilisateur doit s assurer que tous les fils de mise à la terre de la source d énergie électrique, des lignes téléphoniques et des canalisations d eau métalliques, s il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. AVERTISSEMENT: L utilisateur ne doit pas tenter de faire ces raccordements lui-meme; il doit avoir recours a un service d inspection des installations électriques, ou a electricien, selon le cas. L indice de charge (IC) assigné a chaque dispositif terminal indique, pour éviter toute surcharge, le pourcentage de la charge totale qui peut etre raccordée a un circuit téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit bouclé peut etre constituée de n import quelle combinaison de dispositifs, pourvu que la somme des indices de charge de l ensemble des dispositifs ne dépasse pas 100. L Indice de charge de cet produit est 2.
3 SYSTEM INFORMATION Installer Phone Installation Date CONTACTS Name Phone Name Phone Name Phone ZONE INFORMATION Zone Type Protected Area Entrance Delay Exit Delay Bell Cutoff KEYPAD FUNCTIONS [F] Key [A] Key [P] Key [ ][1] Zone Bypassing: No Access Code required to bypass zones Access Code required to bypass zones [ ][7]Command: Resets Smoke Detectors Other: NOTES 1
4 INTRODUCTION Read this manual carefully before operating your security system. Have your installer instruct you on system operation, and have your installer inform you of the features that have been enabled on your system. All users of the system should be instructed in its use. Complete the System Information page and store this manual in a safe place for future reference. Fire Detection Equipment This equipment is capable of monitoring fire detection devices such as smoke detectors, and of providing a warning if a fire condition is detected. Good fire detection depends on having an adequate number of detectors placed in appropriate locations. Fire detection equipment should be installed in accordance with applicable standards and codes. Carefully review the Household Fire Safety and Family Escape Planning sections of this manual. IMPORTANT NOTE: Your installer must enable the fire detection features of this equipment for the functions to be operational. Test Your System Regularly To ensure that your system continues to function as intended, it is important that you test your system weekly. Refer to the Testing Your System section of this manual, and read and follow the instructions carefully. If your system does not function properly or if you have any questions about testing your system, call your installing company for service or assistance. 2 Important Notice A security system cannot prevent emergencies. It is only intended to alert you of an emergency situation. Security systems are generally very reliable but they may not work under all conditions and they are not a substitute for prudent security practices or life and property insurance. Your security system should be installed and serviced by qualified security professionals who should inform you of the level of protection that has been provided, and instruct you on system operations. Glossary Your DSC PC2525 Security System has been designed to offer advanced security features and simple, straight-forward operation. Described here are some terms that are used throughout this manual to explain the operation of your system. Keypad: Your system features one or more PC2550RK Keypads. The keypad is used to enter commands to operate the system, and to view operating information about the system. Information about the system is displayed on the Zone Lights, labelled 1 through 8. The keypad also features seven System Status lights: Ready, Armed, Memory, Bypass, Trouble, Program and Fire. Commands are entered on the keypad by pressing one key at a time. Master Code: The Master Code is a 4-digit code used to arm and disarm the system, to program Access Codes, to bypass zones, and to change certain operating features. Normally only one person should know the Master Code. Access Codes: Seven Access Codes in addition to the Master Code are available to allow users to arm and disarm the system. Each person should keep their 4-digit Access Code secret to ensure system security. Entry Delay: The Entry Delay is the time allowed for someone to enter the premises and disarm the system without causing an alarm. Exit Delay: The Exit Delay is the time allowed for someone to leave the premises without causing an alarm after they have entered an Access Code to arm the system. Entry-Exit Door or Zone: The Entry-Exit Door or Zone is the door or zone designated by your installer to be used for entering and leaving the premises when the system is armed. Zone: A Zone is an area that is protected by a security device. For example, a room protected by a motion detector may be Zone 1, while a window protected by a magnetic contact may be Zone 2. Your installer will inform you of where zones have been set up on your system.
5 BASIC OPERATION Arming Your System Before arming the system, close all protected doors and windows, and stop movement in areas protected by motion detectors. When all zones are closed, all of the Zone Lights on the keypad will be OFF, and the Ready light will be ON. If the Trouble light is ON, check to see which trouble conditions are present on the system. Refer to the Displaying System Information section of this manual for instructions on viewing trouble conditions. Be sure to correct any trouble conditions before arming your system. If the Bypass light is ON, check to see which zones are bypassed. Refer to the Displaying System Information section of this manual for instructions on viewing bypassed zones. Ensure that all zones indicated as being bypassed are bypassed intentionally. Bypassed zones will not cause an alarm. To arm the system, enter a 4-digit Access Code. As each digit is entered, the keypad sounder will beep. When the Access Code has been entered, the Armed light will come ON and the keypad will beep 6 times. If an incorrect Access Code is entered, the keypad will sound a single long tone. To correct a mistake when entering a code, press the [#] Key and enter the Access Code again. When the Armed light comes ON, leave the premises through the designated Entry-Exit door before the Exit Delay expires. At the end of the Exit Delay, the Ready light will be shut OFF - your system is now armed. The factory setting for the Exit Delay is 45 seconds; your installer may change this time to suit your needs. Refer to the Arming Options section of this manual for information on other arming functions. Disarming Your System Enter the premises through the designated Entry-Exit door. The keypad will sound a constant tone to indicate that the system must be disarmed. Go to the keypad and enter an Access Code. If an error is made entering the code, press the [#] Key and enter the code again. When a correct Access Code is entered, the Armed light will be shut OFF, and the sounder will be silenced - your system is now disarmed. An Access Code must be entered before the Entry Delay expires or an alarm will sound. The factory setting for the Entry Delay is 30 seconds; your installer may change this time to suit your needs. If an alarm occurred while the system was armed, the Memory light and the Zone Lights of the zones that went into alarm will FLASH for two minutes. Press the [#] Key to cancel the flashing display and return the keypad to the Ready mode. Refer to Display Alarm Memory for instructions on displaying the zones that went into alarm. IMPORTANT NOTE: If you return to the premises and find that an alarm is in progress or that there are alarms in memory, do not enter the premises: there may be a fire or an intruder may be present. Go to a neighbor and contact the local authorities from there. Bypassing Zones A bypassed zone will not cause an alarm. Zones may be bypassed to allow access to part of the protected area while other zones are armed. For example, you could bypass the zone protecting your living room. This would allow you to remain in the room, while the other zones on your system are armed. With the system disarmed, enter [ ][1] to display bypassed zones. The Zone Lights representing bypassed zones will come ON. Ensure that any zone displayed as being bypassed is intentionally bypassed. Zone bypasses are automatically cancelled when the panel is disarmed. 3
6 To Bypass Zones: Enter [ ][1]; the Bypass light will FLASH. Enter the number of the zone to be bypassed; the corresponding Zone Light will come ON to indicate that the zone is bypassed. To remove a bypass, enter the zone number to shut its Zone Light OFF. When all desired zones are bypassed, press the [#] Key to return to Ready. Notice that the Bypass light will be ON while the system is disarmed to indicate that zones have been bypassed. When you arm your system, the zones you have indicated will now be bypassed. Before arming the system with bypassed zones, it is always a good idea to enter the [ ][1][Access Code] command to review the list of bypassed zones before entering an Access Code to arm the system. After ensuring that the desired zones are bypassed, press the [#] Key, and then enter an Access Code to arm the system. When the system is disarmed, the zone bypasses will be cleared and the zone will again be active. To Recall Bypassed Zones: Enter [ ][1][9]; the Bypass light will FLASH and Zone Lights will come ON to indicate which zones were last bypassed. This feature is useful if you bypass the same set of zones regularly; by recalling the set of bypassed zones, you won t have to enter the zone numbers for each zone each time you wish to bypass the same set. Access Code Required for Bypass: Your security system may be programmed to require an Access Code to be entered to bypass zones. Your installer will inform you if this option has been enabled on your system. If an Access Code is required for bypassing, enter [ ][1][Access Code], and follow the bypassing instructions described above. Keypad Alarms Three types of alarms may be activated by pressing and holding a single key on the keypad. Your installer will inform you of how the [F], [A] and [P] Keys will operate on your system. 4 [F]ire [A]uxiliary [P]anic Press and hold the [F] Key for 2 seconds to sound a Fire alarm; the siren will sound with a pulsed tone. The keypad will sound a series of short beeps once the system has accepted the alarm. If enabled by your installer, a transmission will be sent to your monitoring station. Press and hold the [A] Key for 2 seconds to generate an Auxiliary alarm. The siren will not sound when this function is activated. The keypad will sound a series of short beeps once the system has accepted the alarm. If enabled by your installer, a transmission will be sent to your monitoring station. Press and hold the [P] Key for 2 seconds to generate a Panic alarm. The alarm may be programmed as either silent or audible; your installer will inform you of how this alarm will operate. If your installer has programmed this alarm to be audible, the keypad will sound a series of short beeps once the system has accepted the alarm, and the siren will sound a steady tone. If enabled by your installer, a transmission will be sent to your monitoring station. Utility Output Command A special keypad command may be used to operate various devices connected to your security system. To operate the Utility Output, enter [ ][7] on the keypad. An Access Code may also need to be entered to use this command; your Installer will inform you if an Access Code is required to activate the Utility Output. When the command is entered, the keypad will sound a single tone for 5 seconds, and the Utility Output will be activated for 5 seconds. This command may be used to operate devices such as special lighting or door strikes. This feature may also be used to reset smoke detectors that are connected to your system. Refer to the Fire Zone Operation section of this manual for information. Your installer will inform you of how the Utility Output function is set up for your system.
7 PC2550RK KEYPAD ZONE BYPASSING: Press [ ] then [1], then press the zone you wish to bypass. Press [#] to return to "Ready". Arm System. PROGRAMMING USER CODES: Press [ ] then [5], [Master Code] then press 1 thru 8 for the user code you wish to program. Then enter a four digit code, press [#] to return to ready. INSTANT ARM: Press [ ][9] before any user code to arm system without entry delay. ARM INTERIOR Press QUICK EXIT Press QUICK ARM Press F NOT IN USE A NOT IN USE P NOT IN USE TEST SYSTEM WEEKLY F A P Fire Ready Armed Memory Bypass Trouble Program Zone Lights 1 to 8 indicate zone activity. With the system disarmed, the Zone Lights will come ON to indicate when zones are active, and the Zone Lights will be shut OFF to indicate that zones are secure. PC255ORK R2 [F] Key: Press and hold this key for 2 seconds to sound a Fire alarm [A] Key: Press and hold this key for 2 seconds to generate an Auxiliary alarm [P] Key: Press and hold this key for 2 seconds to generate a Panic alarm. These keys will not function unless enabled by your Installer. The Fire light will come ON where there is any Fire Alarm condition. The Ready light will come ON when the system is ready to be armed. When the Ready light is OFF, there is an open zone on the system. The zone must be closed or bypassed before the system can be armed. The Armed light will come ON to indicate that the system is armed. The Armed light will FLASH to indicate that the system is armed and that there is no Entry Delay on any of the zones. The Memory light will come ON where there are alarms in memory. Enter [ ][3] to view the zones that went into alarm while the system was armed. Press [#] to return to Ready. The Bypass light will come ON when there are bypassed zones. Enter [ ][1] to view the zones that are bypassed. Ensure that any bypassed zones are bypassed intentionally before arming the system. Press [#] to return to Ready. The Trouble light will come ON where there is a trouble condition present on the system. Enter [ ][2] to view trouble conditions. Press [#] to return to Ready. The Program light will come ON when Access Codes are being programmed and when system functions are being changed. Press [#]: when an error is made in entering an Access Code, then enter the code again to return to Ready after using [ ] commands Important: Follow the instructions in the manual to test your system weekly. Follow the guidelines for correcting system trouble conditions; have any system trouble conditions you cannot correct yourself attended to by your installer. 5
8 ARMING OPTIONS About Home-Away Zones Some zones on your system may be programmed as Home-Away Zones so that you may use the Arming Options described on this page. Home-Away Zones feature the ability to be automatically bypassed when the commands described below are entered; this saves you the trouble of having to manually bypass zones using the [ ][1] Bypass command. Your installer will inform you of which zones on your system are programmed as Home-Away Zones. At-Home Arming At-Home Arming automatically bypasses the Home-Away Zones on your system, and removes the Entry Delay from the Entry-Exit Zones. This feature allows you to arm the system and remain on the premises. In addition, if any of the Entry-Exit doors are opened, an alarm will sound instantly. To use At-Home Arming, enter [ ][9][Access Code] on the keypad. The Armed light will FLASH to remind you that there is no Entry Delay on the Entry-Exit doors. Home-Away Arming Home-Away arming automatically bypasses the Home-Away Zones; the Entry Delay will still apply to the Entry-Exit zones. You may use this feature to arm the system and remain on the premises. Another household member would still be able to enter the premises through the Entry-Exit door without causing an alarm. When the Entry-Exit door is opened, an Access Code would have to be entered to disarm the system. To arm the system with Home-Away Arming, enter an Access Code and do not open the Entry-Exit door. When the Exit Delay expires, the system will be armed with the Home-Away Zones automatically bypassed. The Bypass light will come ON to indicate that the Home-Away Zones have been automatically bypassed. To reactivate the zones automatically bypassed by Home-Away Arming, enter [ ][1] on the keypad. The Bypass light will be shut OFF to indicate that the Home-Away Zones are no longer bypassed. Quick-Exit The Quick-Exit feature allows you to leave the premises when the system is armed with At-Home or Home- Away Arming without having to disarm the system. To use the Quick-Exit feature, enter [ ][0] while the system is armed. When the command is entered, you will be allowed up to 2 minutes to activate a Delay Zone and leave the premises. If the Entry-Exit Delay Zone is opened after 2 minutes, the Entry Delay will begin. If the system is not disarmed before the end of the Entry Delay, an alarm will sound. Quick-Arm The Quick-Arm feature allows you to enter [ ][0] to arm the system. This command is designed to allow someone to arm the system without that person having to be provided with an Access Code. When [ ][0] is entered, the Armed light will come ON and the Exit Delay will begin; you may now leave the premises through the Entry-Exit door. At the end of the Exit Delay, the system will be fully armed. Refer to the Changing System Functions section of this manual for instructions on turning the Quick-Arm function on and off. 6
9 DISPLAYING SYSTEM INFORMATION Display Bypassed Zones Enter [ ][1] to display any bypassed zones on the system. If a zone is bypassed, its zone light will come ON when this command is entered. Before arming the system, ensure that the zones indicated on the display are intentionally bypassed. When finished viewing the bypassed zones, press the [#] Key to return to Ready. Display Alarm Memory When a zone generates an alarm, the alarm will be recorded in the system s Alarm Memory. Alarm Memory records the most recent set of alarms. To display the zones that went into alarm the last time the system was armed, enter [ ][3]. The Memory light will FLASH, and the zones that went into alarm will be displayed on the flashing Zone Lights. The keypad sounder will beep once to indicate that the most recent set of alarms is being displayed. When finished viewing Alarm Memory, press the [#] Key to return to Ready. Display Trouble Conditions The PC2525 constantly monitors itself to ensure proper operation. When a condition occurs that could affect operation, the Trouble light will come ON and the keypad sounder will beep every 10 seconds to indicate that there is a trouble condition present on the system. To silence the sounder, press the [#] Key. The keypad will be silenced, but the Trouble light will remain ON until the trouble condition is cleared. To display the trouble conditions, enter [ ][2]. Trouble conditions are represented with the Zone Lights; if a Zone Light comes ON, then that trouble condition is present: Zone Light Trouble What To Do 1 Battery Trouble Call for service 2 AC Failure Check your fusebox or circuit breakers; call for service if the trouble cannot be corrected 3 Not used to indicate trouble conditions 4 Telephone Line Trouble This condition will be cleared when the trouble on the telephone line is corrected. If this trouble does not clear itself automatically, arrange for service 5 Failure to Communicate This trouble will be cleared if the system again tries to call the monitoring station and is able to complete the call. If this trouble does not clear itself automatically, call for service 6 Bell Trouble Call for service 7 Fire Zone Trouble Call for service immediately 8 Reset Clock Reset the clock; refer to Changing System Functions for instructions 7
10 CHANGING SYSTEM FUNCTIONS Changing Access Codes The PC2525 features 8 programmable Access Codes. The first code is the Master Code, and the remaining codes are normal Access Codes. Programming Access Codes: Enter [ ][5][Master Code]; the Program light will FLASH. The Zone Lights will indicate which Access Codes have been programmed, and which Access Code is presently being programmed: Zone Light is... Access Code is... OFF not programmed ON steady programmed Flashing presently being programmed When the [ ][5][Master Code] command is entered, Zone Light 1 will be ON to indicate that the Master Code is already programmed. Changing or Adding a Code: To change the Master Code or Access Codes 2 through 8, enter the number of the code to be changed; the corresponding Zone Light will begin to FLASH. For example, enter [1] to change the Master Code, or enter [2] to change Access Code 2, and so on. With the desired Zone Light flashing, enter a new 4-digit Access Code. Do not press [ ] or [#] when entering the code. If an existing code is being changed, the new code will replace the old one. After the code is entered, the keypad will beep 6 times and the Zone Light will stop flashing and remain ON. If you want to program another code, press the number key for the code to be programmed, and enter the new 4-digit code as described above. When all desired changes are complete, press the [#] Key to return to Ready. Erasing a Code: To erase a code, enter [ ][5][Master Code]. Enter the number of the code to be erased; the Zone Light for the code will FLASH. Enter [ ] to erase the Access Code. When all desired changes are complete, press the [#] Key to return to Ready. IMPORTANT: Do not erase the Master Code. If the Master Code is accidentally erased, contact your installing company for assistance. Door Chime On/Off The Door Chime feature causes the keypad to beep whenever a zone defined as a Chime zone is activated; your installer will inform you of which zones on your system will activate the Door Chime feature. This feature is useful if the Entry-Exit door or doors are out of view, and you would like an indication of when the door zones are opened and closed. Note that the Door Chime feature only functions when the system is disarmed. To turn the Door Chime feature on or off, enter [ ][4]. If the feature is being turned ON, the keypad sounder will beep 3 times. If the feature is being turned OFF, the sounder will emit a single long tone. 8
11 Setting the Clock To set the system s internal clock, enter [ ][6][Master Code][1]; the Program light will FLASH. Enter the time of day using the Number Keys. Enter the time in the 24-hour clock format: the hour is entered as a 2-digit number from 00 to 23, minutes are entered as a 2-digit number from 00 to 59. For example, the time 9:30 am would be entered as 0930; the time 2:45 pm would be entered as When the time has been entered, press the [#] Key to return to Ready. Turning Quick-Arm On and Off To turn the Quick-Arm feature ON and OFF, enter [ ][6][Master Code][4]. When the feature is being turned ON, the keypad will sound three quick tones. When the feature is being turned OFF, the keypad will sound a single long tone. When the Quick-Arm feature is turned ON, the system may be armed simply by entering [ ][0]. Refer to the Arming Options section of this manual for information on using the Quick-Arm feature. 9
12 FIRE ZONE OPERATION NOTE: Fire Zones will not be operational on your system until your installer has enabled this feature. Your installer will inform you if these zones are operational on your system, and of which zones are affected. Fire Zones are armed at all times, whether the rest of the system is armed or disarmed. When a Fire Zone is activated, an alarm will sound with a pulsing tone, even if the rest of the system is disarmed. Be sure to read the Fire Safety in the Home, Household Fire Safety and Family Escape Planning sections of this manual. When a Fire Alarm Sounds If the Fire Alarm sounds at night, do not investigate the alarm. Follow your evacuation plan immediately. Go to a neighbor and contact the fire department from there. When a Fire Zone generates an alarm, the bell or siren on your system will sound with a pulsing tone - the bell or siren will be ON for 2 seconds, and then OFF for 2 seconds. Transmission of the fire alarm to your monitoring station is delayed for 30 seconds to allow you to cancel possible false alarms. To silence the alarm, press the [#] Key. When the [#] Key is pressed, the system will delay transmission of the fire alarm for an additional 90 seconds. The 90-second delay is intended to allow you to reset the smoke detectors after a false alarm. If the smoke detector is reset and remains reset after the 90-second delay, a fire alarm will not be transmitted to the monitoring station. If the smoke detector is reset but goes into alarm again after the 90-second delay, the fire alarm will sound again and the process described above will repeat. A fire alarm will be transmitted to your monitoring station after 30 seconds if it is not silenced by pressing the [#] Key or by entering an Access Code. Resetting Smoke Detectors Smoke detectors installed on your system may be reset after a false alarm using the procedure described here. IMPORTANT: Your installer will inform you if the [ ][7] command has been set up to reset smoke detectors on your system. If a false alarm sounds, (for example, an alarm caused by cooking smoke), first silence the alarm by pressing the [#] Key within 30 seconds of the alarm s sounding. You should only silence an alarm and reset the smoke detectors if you are absolutely certain that there is no real threat of fire. To reset the smoke detectors to normal, first clear all products of combustion from the detectors. Reset the detectors by entering [ ][7] on the keypad. If the detectors are clear of smoke, they will return to normal. If the detectors still have smoke in them, the alarm will sound again. If the alarm sounds again, first ensure that there is no threat of fire; you may then silence the alarm and reset the smoke detectors. 10
13 TESTING AND MAINTENANCE Bell Test Entering this command will sound the siren and turn ON all the keypad lights for 2 seconds. To perform a bell test, enter [ ][6][Master Code][8] on the keypad. Weekly Testing It is recommended that you test your system weekly. 1 Inform the monitoring station that you are testing your system. 2 Disarm the system and ensure that the Ready light is ON. 3 Perform a Bell Test by entering [ ][6][Master Code][8]. The bell or siren will sound for 2 seconds and all of the lights on the keypad will come ON. 4 Activate each sensor on your system in turn. For example, open protected doors and windows, and walk in areas protected by motion detectors. Each Zone Light should come ON when each zone is activated. Each Zone Light will be shut OFF when the zone is restored to normal (when the door or window is shut, or when motion stops in areas protected by motion detectors). 5 If they are programmed for operation, press the [F], [A], and [P] keys in turn. The [F] key will sound the bell or siren in a pulsed mode. Enter an Access Code to silence the alarm. The [A] key is a silent alarm; the [P] key may be programmed as silent or audible. If an alarm sounds, enter an Access Code to silence the alarm. 6 If the system features a fire zone, activating the smoke detector or other fire detection device will cause the bell or siren to sound in a pulsed mode. CAUTION: Do not use an open flame or burning materials to test a smoke detector. Contact your installer for instructions on safe methods of activating a smoke detector. 7 Should the system fail to operate properly, call your alarm dealer for service. 8 When testing is complete, call and advise the monitoring station. Maintenance With normal use, your system requires a minimum of maintenance. The following points should be observed: 1 Do not wash the keypad with a wet cloth, and do not use household cleaners, such as glass cleaners, on the keypad. Light dusting with a cloth slightly dampened with plain water should remove normal accumulations of dust. 2 For other system devices such as passive infrared, ultrasonic or microwave motion detectors, glassbreak detectors or smoke detectors, consult the manufacturer s literature for testing, cleaning and maintenance instructions. 3 It is recommended that the back-up battery be replaced every three years. Contact your installing company for information on replacing the battery. 11
14 FIRE SAFETY IN THE HOME Most fires occur in the home, and to minimize this danger it is recommended that a household fire safety audit be conducted and a family escape plan be developed. Household Fire Safety Check your home for the following potential hazards: Are all electrical appliances and outlets in a safe condition? Check for frayed cords, over-loaded lighting circuits, and so on. If you are uncertain about the condition of your electrical appliances or household electrical service, have a professional evaluation. Are all flammable liquids stored safely in closed containers in a well ventilated and cool area? Cleaning with flammable liquids, such as gasoline, should be avoided. Refer to product instructions, printed warnings and labels for information on using and storing hazardous materials safely. Are fire hazardous materials (such as matches) well out of the reach of children? Are furnaces and wood burning appliances properly installed, clean, and in good working order? If in doubt, have a professional evaluation. Family Escape Planning There is often very little time between the detection of a fire and the time at which it becomes deadly. Because of this, it is very important that a family escape plan be developed, practised and followed. 1 Every family member should participate in developing the escape plan. 2 Study the possible escape routes from each location within the house. Since many fires occur at night, special attention should be given to the escape routes from sleeping quarters. 3 It is essential that escape from a bedroom be possible without opening the interior door. Consider the following when making your escape plans: Make sure that doors and windows that open to the outside are easily opened. Ensure that they are not painted shut and that their locking mechanisms operate smoothly. If opening an exit or using an exit is too difficult for children, the elderly or handicapped, plans for rescue should be developed. This includes making sure that those who are to perform the rescue can promptly hear the fire warning signal. If the exit is above ground level, an approved fire ladder or rope should be provided, as well as training in its use. Exits on the ground level should be kept clear. Be sure to remove snow from exterior patio doors in winter. Outdoor furniture or equipment should not block exits. The family should have a predetermined assembly point where everyone can be accounted for; for example, across the street or at a neighbor s house. Once everyone is out of the house, call the Fire Department. A good plan emphasizes quick escape. Do not investigate first or attempt to fight the fire, and do not attempt to rescue belongings as this takes up valuable time. Once outside, do not re-enter the house. Wait for the fire department. Write the plan down and rehearse frequently, so that should an emergency arise, everyone will know what they are to do. Revise the plan as conditions change; for example, when there are more or fewer family members in the home, or if there are physical changes to the house. Make sure your fire warning system is operational by conducting weekly tests as noted elsewhere in this manual. If you are unsure about system operation, contact your installing company. It is recommended that you contact your local fire department and request further information on home fire safety and escape planning. If available, have your local fire prevention officer conduct an in-house fire safety inspection. 12
15 LIMITED WARRANTY Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free of defect in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper application of the equipment. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd. This warranty contains the entire warranty. Digital Security Controls Ltd. neither assumes, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall Digital Security Controls Ltd. be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected.
16 1994 Digital Security Controls Ltd R Flint Road, Downsview, Ontario Canada M3J 2J6 January Telephone: (416) Fax: (416)
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD TABLE OF CONTENTS SYSTEM INFORMATION 2 INTRODUCTION 3 Test Your System Regularly...3 Important Notice...3 Glossary...3 BASIC OPERATION 4 Arming Your System...4
INSTRUCTION MANUAL PC255O
INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
INSTRUCTION MANUAL LCD-6OO SECURITY STATION
INSTRUCTION MANUAL 1993 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29000144 R1 LCD-6OO SECURITY STATION Table of Contents Introduction 1 About
Instruction Manual PC55O. With PC5OORK Keypad. 1996, 2002 Digital Security Controls Ltd. Toronto, Canada Printed in Canada 29000534 R3
Instruction Manual 1996, 2002 Digital Security Controls Ltd. Toronto, Canada Printed in Canada 29000534 R3 PC55O With PC5OORK Keypad Industry Canada Notice NOTICE: The Industry Canada label identifies
INSTRUCTION MANUAL PC15OO/155O WITH LED615 KEYPAD
INSTRUCTION MANUAL PC15OO/155O WITH LED615 KEYPAD Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that
INSTRUCTION MANUAL DSC 1550
INSTRUCTION MANUAL DSC 1550 A WORD ABOUT YOUR SYSTEM The PC1550 Security System has been designed to give you the greatest possible flexibility and convenience. Read this manual carefully and become familiar
INSTRUCTION MANUAL SOFTWARE VERSION 1.0R
INSTRUCTION MANUAL SOFTWARE VERSION 1.0R FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment.
INSTRUCTION MANUAL. DSC Security Products PC1500/PCI550
INSTRUCTION MANUAL DSC Security Products PC1500/PCI550 ABOUT YOUR SECURITY SYSTEM Your DSC security equipment has been designed to give you the greatest possible flexibility and convenience. Read this
Instruction Manual. version 1.0
Instruction Manual version 1.0 Table of Contents About Your ADT Security System 1 Fire Detection 1 Testing 1 Monitoring 1 General System Operation 1 System Information 2 Access Codes 4 Arming the System
PC Tab Security System INSTRUCTION MANUAL
PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
User s Guide. Security Systems D220
User s Guide Security Systems D220 Table of Contents About This User s Guide... 3 Introduction... 3 Security System Basics... 4 Controlled Points... 5 24-Hour Points... 6 Keypad Keys... 6 Keypad Lights...
How To Use A Keypad On A Iphone Or Ipad (Awn) With A Security System On A Powerline (Apl) With An Alarm System On It (Aldeen) And A Power Button On It
WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
Power864. User s Guide. Now classified in accordance with ANSI/SIA CP-01-2000 (SIA-FAR)
WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
SECURITY SYSTEM NOTES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary
642 LCD Keypad User Manual
642 LCD Keypad User Manual TABLE OF CONTENTS Introduction...3 Legend... 3 Basic Operation...5 Keypad Indicator Lights... 5 Visual Feedback... 5 Auditory Feedback... 6 Info List... 7 Access Codes...8 User
User s Guide. Security Systems
User s Guide Security Systems National Security Systems Inc (800)457-1999 2 Table of Contents About This Users Guide... 4 Introduction... 4 Security System Basics... 5 Controlled Points... 6 24-Hour Points...
User s Guide. Security Systems
User s Guide Security Systems 2 Table of Contents About This Users Guide... 4 Introduction... 4 Security System Basics... 5 Controlled Points... 6 24-Hour Points... 7 Keypad Keys... 7 Keypad Tones... 8
National Security Systems Inc (800)457-1999. Security System User's Guide
National Security Systems Inc (800)457-1999 Security System User's Guide Security System Glossary As security system technology has evolved, a special jargon has developed. Some terms widely used within
Security System User's Guide
Security System User's Guide Security System Glossary As security system technology has evolved, a special jargon has developed. Some terms widely used within the industry are these: Arm and Disarm Your
SPECIAL CODES AUXILIARY CODES SYSTEM NOTES
Installing/Service Company Monitoring Center SPECIAL CODES Master Code Duress Code AUXILIARY CODES "Quick Arm" " Chime" 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Entry Delay Time
SECURITY SYSTEM NOTES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Central Station Duress Code FUNCTION CODES Function Code Controls Function This system is is not partitioned. EMERGENCY ACTIVATION KEYS
Programming Worksheets. Power864. PC5O20 Version 3.2C. DLS-3 v1.3 and higher
Programming Worksheets Power864 TM S E C U R I T Y S Y S T E M PC5O20 Version 3.2C DLS-3 v1.3 and higher FCC Compliance Statement: CAUTION: Changes or modifications not expressly approved by Digital Security
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
Using your LED Plus keypad
Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced
Instruction Manual PC15OO/PC155O W A R N I N G
Instruction Manual PC15OO/PC155O W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
32 ZONE SECURITY SYSTEM. Compatible with DLS-3 v1.3 (and higher) downloading software
NT9005 V1.0 32 ZONE SECURITY SYSTEM Compatible with DLS-3 v1.3 (and higher) downloading software User Guide WARNING: This manual contains information on limitations regarding product use and function and
NetworX NX-6V2. LED Keypad User Manual
NetworX NX-6V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous
SECURITY SYSTEM NOTES. Security System Configuration
Installing / Service Company: For Service Call: SECURITY SYSTEM NOTES Security System Configuration Master Code: Auxiliary Code(s) 2 3 4 5 6 "Quick Arm" Digit: Exit Delay Time Auxiliary Exit Delay Time
TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2
TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad
SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration
Installing / Service Company: SECURITY SYSTEM NOTES For Service Call: Master Code SPECIAL CODES Duress Code Security System Configuration Auxiliary Code(s) Quick Arm" Digit: 2 9 3 10 4 11 5 12 6 13 7 14
N5100-3V3 9/96. USER'S MANUAL FA120C Security System
N5100-3V3 9/96 USER'S MANUAL FA120C Security System TABLE OF CONTENTS SYSTEM OVERVIEW... 4 Keypads... 4 Zones... 4 Alarms... 5 Fire Protection... 5 Burglary Protection... 5 Memory of Alarm... 5 Pager Notification...
LCD5500Z / PKP-LCD v3.x Installation Instructions
LCD5500Z / PKP-LCD v3.x Installation Instructions TM Introduction The LCD5500Z / PKP-LCD keypad displays system status using an LCD screen. The keypad can be used on PowerSeries security systems with up
Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function
WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
About Your Security System. General System Operation
About Your Security System Your DSC Power832 Security System has been designed to provide you with the greatest possible flexibility and convenience. Read this manual carefully and have your installer
Security System. User's Guide. Keypad
Security System EN User's Guide Keypad Security System User's Guide This system includes a telephone line seizure feature. The system can be programmed to communicate with a central monitoring station
SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS
SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES Master Code Duress Code "Quick Arm" Digit "Chime" Digit "Entry-Guard" Digit AUXILIARY ARM / DISARM CODES 02 12 22 03 13 23
Digiplex LCD Keypad DGP-641. User s Manual
Digiplex LCD Keypad DGP-641 User s Manual 1.0 TABLE OF CONTENTS INTRODUCTION...6 1.1 Legend... 6 BASIC OPERATION... 7 2.1 Auditory Feedback (Beep Tones)... 8 2.2 Keypad Indicator Lights... 8 2.3 LCD Screen...
Simon Security System. User Guide. Technical Manuals Online! - http://www.tech-man.com. 466-1871-01 Rev A June 2004. Part No: 60-875 600-1012
) *(6HFXULW\ 466-1871-01 Rev A June 2004 ZZZ*(6HFXULW\FRP Part No: 60-875 600-1012 Doors & Windows Motion Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion Time
www.ealarm.com.my P/N 5-051-371-00 Rev D
System 236 System 236i P/N 5-051-371-00 Rev D Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced alarm systems on the market today, designed to provide
Security System. User Guide for the LED Command Center
Security System User Guide for the LED Command Center MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE
INSTALLATION MANUAL PC2525. Version 1.1
INSTALLATION MANUAL PC2525 Version 1.1 TABLE OF CONTENTS FEATURES 1 SPECIFICATIONS 1 INSTALLATION 2 Mounting the Panel... 2 Mounting the Keypad... 2 Auxiliary Power Connection... 2 Bell/Siren Connection...
SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Installation Date / / Central Station Duress Code EMERGENCY ACTIVATION KEYS (check if enabled) Fire Auxiliary Emergency Police PROGRAMMED
SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES
SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES "Chime" Digit 1 "Partial Arm" Digit 2 "Quick Arm" Digit 3 ENTRY / EXIT DELAY TIMES Exit Delay Time Entry Delay Time Secondary
Simon Security System. User Guide. 466-1871 Rev J May 2003. Part No: 60-875 ZZZ*(,QWHUORJL[FRP. System Status HOME SECURITY. Windows Sensors.
) 466-1871 Rev J May 2003 *(,QWHUORJL[ ZZZ*(,QWHUORJL[FRP Part No: 60-875 Doors & Motion Windows Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor On
LCD and 16-Zone LED Keypads. User s Manual
LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
Using Your GEM-P400 Security System
Using Your GEM-P400 Security System ARMED GEMINI STATUS 1 2 3 4 &20387(5,=(' 6(&85,7< 6
CONTENTS 4. HOW TO UNSET THE PANEL...7
Pi-8 USER MANUAL CONTENTS 1. THE KEYPAD AND ITS OPERATION...3 1.1 DESCRIPTION OF THE KEYPAD LEDS... 3 1.1.1 READY LED (RED)...3 1.1.2 TAMPER LED (RED)...3 1.1.3 POWER LED (GREEN)...3 1.1.4 CIRCUIT LEDs
Simon Security System. User Guide. 466-1871 Rev F September 2002. Part No: 60-875 ZZZ*(,QWHUORJL[6HFXULW\FRP. System Status HOME SECURITY
) 466-1871 Rev F September 2002 *(,QWHUORJL[ ZZZ*(,QWHUORJL[6HFXULW\FRP Part No: 60-875 Doors & Motion Windows Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion
SECURITY SYSTEM NOTES AREA LISTINGS SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS
SECURITY SYSTEM NOTES Installing/Service Company For Service Call Area 1 Area 2 Area 3 AREA LISTINGS SPECIAL CODES "Quick Arm" Digit "Partial Arm" Digit "Chime" Digit ENTRY / EXIT DELAY TIMES Exit Delay
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 2
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 2 THE BRINK S HOME SECURITY SYSTEM Equipment in the Standard Systems... 3 Optional Equipment... 4 Optional Features... 5 Description of the Keypad... 6 OPERATING
NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)
NetworX Series NX- 4/8 Code Pad User Manual (Australian Version) Table Of Contents Code Pad Diagram... Inside Front Glossary of Terms...2 Understanding the Code Pad lights...3 Code Pad Tones...4 Fully
PK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
10-Zone Spectra LED Keypads
10-Zone Spectra LED Keypads 1686V 1686H User s Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions
Simon Security System. User Guide. 466-1871 Rev H April 2003. Part No: 60-875 ZZZ*(,QWHUORJL[FRP. System Status HOME SECURITY. Windows Sensors.
) 466-1871 Rev H April 2003 *(,QWHUORJL[ ZZZ*(,QWHUORJL[FRP Part No: 60-875 Doors & Motion Windows Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor
WARNING NT9010 www.dsc.com
WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
GE Concord 4 Quick User Guide
GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is there a flashing
User Guide for the DS7060 Control/Communicator
DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 1
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 1 THE BRINK S HOME SECURITY SYSTEM Equipment in the Standard Systems... 2 Optional Equipment... 3 Description of the Keypad... 5 OPERATING THE BRINK S SYSTEM
IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18
INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay
NT9005 V1.0 NA 32 ZONE SECURITY SYSTEM. O P E N 12345678 AM Memory. Bypass Fire. Chime. Stay. Away. Trouble. Armed. Ready
NT9005 V1.0 NA 32 ZONE SECURITY SYSTEM User Guide O P E N 12345678 AM Memory Bypass Fire ALARM Stay Away PM Program Chime Ready Armed Trouble 1 4 7 2 3 5 6 8 9 0 # Stay Away Chime Interior Exit WARNING:
User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up
RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-6506444 +972-3-5500442 [email protected] http://www.pima-alarms.com
Digiplex LCD Keypad DGP-641. User s Manual
Digiplex LCD Keypad DGP-641 User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION... 7 1.1 Legend... 7 2.0 BASIC OPERATION... 8 2.1 Auditory Feedback (Beep Tones)... 9 2.2 Keypad Indicator Lights... 9 2.3
THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL. Security Control Panels with Integrated Communicator. Issue 6
THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL Security Control Panels with Integrated Communicator Issue Contents Premier 4// Master User Manual Contents. About the System... Introduction... About this
USER INSTRUCTIONS CONTENTS
CONTENTS Full Set [1]...2 Part Set [2]...2 Night Set [3]...3 Unsetting...3 Unsetting after or during an alarm...3 Testing the system [5]...3 Isolating zones [6]...4 Reprogramming codes [8]...4 Chime facility
SECURITY SYSTEM MANUAL
SECURITY SYSTEM MANUAL CONTACT NUMBERS: Phase 3 Security 403-783-2199 Technical Difficulties, Account Updates, & Any Other Inquiries: Consolidated Monitoring 1-800-232-7290 False Alarms & Holiday Procedures
CA60 Plus Software Version 3.1 User Manual May 2000
TeleT eletek ek CA60 Plus Software Version 3.1 User Manual May 2000 CONTENTS 1. CA60Plus Keypad... 3 1.1. LED display... 3 1.2. Keys... 4 1.3. Combinations of Keys... 4 1.4. Audible Indication... 4 2.
Users Guide to Keypad Functions
Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &
Digital Security Controls
Digital Security Controls Publications Cover Sheet Part Number: 29007110R001 Revision: 001 Release Number: 5814 Notes:New Description: PC1616/PC1832/PC1864 UK USER INSTRUCTION MANUAL Type: 33-13 8.5 x
Security System User s Guide
Security System User s Guide Table of Contents Introduction Command Center Function Keys Security System Basics Your Custom Display View Faulted or Bypassed Points Warning Displays and Tones Fire Alarms
Instruction Manual W A R N I N G PC1555/PC1555MX
W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
Using Your. Security System With Icon Keypad S5020, S5021, S5022
Using Your Security System With Icon Keypad S5020, S5021, S5022 Contents 1 Overview Your Security System... 1 How Your Security System Works... 2 Your System's Programming... 3 Getting Used to Your System...
FBII Security System. User Guide
FBII Security System OMNI -408 OMNI -408EU User Guide N9942-2V2 4/04 Rev. A 2 Table Of Contents QUICK REFERENCE...4 Arming the System...4 Disarming the System...4 Arm System/Stay Inside...4 Arm System/Stay
SCORPION Z16040C Alarm Controller User Instructions
SCORPION Z16040C Alarm Controller User Instructions Thank you for choosing to purchase this micron security alarm controller. Micron product is manufactured to exacting quality standards. We understand
MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3
MONITOR ISM / AFx Multi-Tenant Security System User Guide V.3 Multi-Tenant Security System User Guide Welcome New Users! There are two types of suite security keypads. Follow the instructions in the proceeding
PHONE ACCESS USER'S GUIDE
PHONE ACCESS USER'S GUIDE For Security Systems With Ademco s V I P (VISTA Interactive Phone) U.S. PATENT No. 4791658 N6432V2 9/94 TABLE OF CONTENTS INTRODUCTION... 4 General Information... 4 Type of Telephone
CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com
CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i
Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the user s authority to operate the equipment.
0 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the user s authority to operate the equipment. FCC Part 15 Class
PC4010 v3.0 Installation Manual DLS-2 v1.3
PC4010 v3.0 Installation Manual DLS-2 v1.3 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
PC1616/PC1832/PC1864 v4.2 User Manual
WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
SCORPION. micron security products
SCORPION 4120 6020 & 8020 USER INSTRUCTIONS Thank you for purchasing a Quality Micron Security Alarm Controller. Micron product is manufactured to exacting quality standards. We understand the importance
HARDWIRED CONTROL PANELS
USER GUIDE 9651 HARDWIRED CONTROL PANELS Contents 1. Introduction...3 The Alarm System...3 The Keypad...3 About This Guide...5 2. Everyday Operation...6 How Do I Know if the System is Working?...6 Setting
Intruder alarm system Operating Instructions
New remote keypad Intruder alarm system Operating Instructions 0 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Power Power 0 2 3 5 6 7 8 Chime Omit Prog 4 9 Set AccentaG3 mini Servicing organisation details
Security System Owner s Manual
Security System Owner s Manual Interactive Technologies Inc. 2266 North 2nd Street North St. Paul, MN 55109 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved
Destiny 4100. Destiny 4100. Owners Manual
Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6
Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...
TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6
TABLE OF CONTENTS FEATURES
TABLE OF CONTENTS FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2 PC1500RK Keypad... 2
Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security
Accenta/Optima User Guide ZONE 1 2 3 4 5 6 7 8 9 Chime Omit Prog PA 0 1 2 3 4 5 6 7 8 9 CHIME OMIT RESET PROG SET Accenta + TA PA DAY POWER PA! " # $ % & 0 1 2 3 5 6 7 8 Chime Omit Reset Prog 4 9 Set PA
D1260/D1260B. Keypad. National Security Systems Inc (800)457-1999. Owner's Manual
D1260/D1260B EN Owner's Manual Keypad National Security Systems Inc (800)457-1999 D1260/D1260B Owner's Manual This system includes a telephone line seizure feature. The system may be programmed to communicate
System User s Manual
System User s Manual BHS-4000A Consumer Information FCC Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These