Emergency Voice Communication Systems

Similar documents
GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

Sound Engineering for 60 Years EmerCall Disabled Refuge and Fire Telephone System

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

BS5839 Part 1:2002 Overview

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Emergency voice communications Product Name

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

VoCALL - CFVCM/CFVCWM & CFVCX8. Fire Telephone & Disabled Refuge Network System. User Manual & Log Book

Communication A BRITISH MANUFACTURER. Features:

Fire Alarm system Installation Guide

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

EMERCALL FIRE TELEPHONE AND DISABLED REFUGE APPLICATION & DESIGN GUIDE - AUGUST 2007

FIRE DETECTION AND ALARM SYSTEMS

Fire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1

How To Write A Fire Risk Assessment

EVACUATION OF DISABLED PEOPLE (Document under constant review)

I.S :2013 Fire Detection & Alarm Systems

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

Fire precautions in dwellings. Private sector housing Providing homes building communities

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Notifier by Honeywell: Voice Alarm Solutions

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

I.S :2013 Fire Detection & Alarm Systems

Guide to Fire Alarm Systems

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

SigTEL EVC System. Operator Instructions

Product Overview Brochure. Flexibility to design a fire system that best suits you

Overview of Fire Alarm Systems and Maintenance

9452/9453 Installation and User Guide

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

Emergency Lighting Practices in the UAE. Richard Caple MSc MSLL Lighting Applications Manager SLL Vice President

Emergency Planning Guideline

Fire Policy and Procedures. Cañada Blanch Spanish School

Standard the the Raising

The terms hazard and risk are often used, which we define as the following:

TSA Conference Reducing the Risk of Fire to the Vulnerable Person through Telecare. London Fire Brigade

section one guide to design, installation,commissioning and maintenance of fire systems in non domestic premises Consultant s Guide

FIRE RISK ASSESSMENT WORKED EXAMPLE

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

FIRE SAFETY RECORD OF TESTS LOGBOOK

FIRE RISK ASSESSMENT PRINCIPLES A GUIDE FOR LICENSED PREMISES

DOMESTIC SMOKE ALARMS

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

FIRE SAFETY PRECAUTIONS

EMERGENCY LIGHTING DESIGN GUIDE

Public Address and Voice Alarm

Voice alarm system E100 the new standard for safe evacuation

Fire safety advice for landlords

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Customer Access 1 Checklist for Banks, Financial and Legal Services

welcome to our world fire alarm systems - series 600

D1260/D1260B. Keypad. National Security Systems Inc (800) Owner's Manual

TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak

City of Bettendorf Fire Alarm System Requirements

Quantec Wiring Instructions

Hospital Patient Management System

NHSScotland Firecode. Scottish Health Technical Memorandum 82. Fire alarm and detection systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

NY Fire Safety Institute

FIRE-FIGHTING DESIGN BRIEF REPORT

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Policy for the Control of Fire

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

OFM-TG Office of the Fire Marshal F M FIRE DRILLS GUIDELINE

Your responsibilities if you have an automatic fire alarm. A handy guide for owners and responsible persons

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

Fire Risk Assessment Safety Checklist

Building Control Guidance Note

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

PLAN REVIEW GUIDE FOR FIRE ALARM

Hotel Accessibility Pack

FIRE SAFETY RISK ASSESSMENT

Guidance for Electrical Contractors on Emergency Lighting Legislation

Greater Manchester Fire and Rescue Service

FIRE ESCAPE SIGNS Guidance on compliance

EMERGENCY EVACUATION PLAN FOR LIFE AND FIRE SAFETY

Emergency Procedures IF YOU DISCOVER A FIRE. Upon discovering a fire: the following steps are to be taken:

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

ELECTRONIC FIRE & SECURITY SYSTEMS. Smoke Alarms, Fire Detection and Alarm Systems in Dwellings

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

IMPORTANT USER INFORMATION

Fire Safety Challenges and Solutions. Claire Guise Health and Safety Manager

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

500r+ Installation and User Guide

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) Fax: (306)

Consultants Guide Issue 1 : 2012

Fire Alarms- Use of buildings when they are out of service

For use by landlords of small premises Premises Address

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

Guidance Document on Fire Safety Signs and Notices FIA Guidance for the Fire Protection Industry

Compliance Schedules and Building Warrant of Fitness

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

1.1.4 The findings from Fire Risk Assessment must be incorporated into the FRAMS Action Plan to manage fire safety at each premise.

Transcription:

Emergency Voice Communication Systems Frequently sked uestions What is an Emergency Voice Communication System? Emergency Voice Communication System is the generic technical term to cover Fire Fighting Telephone Systems and Disable Refuge Communication Systems. What is a Disabled Refuge? Disabled Refuge is a relatively safe area within a building or exit staircase where mobility impaired occupants can be placed (not just wheelchair users) while the main building occupancy is evacuated, allowing building management and emergency services to safely assist these people from the building when stairwell crowding has eased. Mobility impairment is defined as not being able to walk 200 m continuously without aid, and includes arthritis sufferers, people with leg and back injuries and women over 6 months term pregnancy. Disabled Refuge system is not just for use during a fire, must be available at all times and MUST NOT BE DISBLED OUTSIDE OF FIRE EMERGENCY (for a full description see building regulations approved document B). Page 1 of 5 - EVCS_F_0712

What is a Disabled Refuge system? n EVCS (Emergency Voice Communication System) is a fixed, monitored and maintained, bidirectional, full duplex voice communication system to assist the orderly evacuation of disabled or mobility impaired people and enhance fire fighters communication during emergencies. Disabled refuge systems are required in the UK in all non domestic premises over 1 story or where an emergency exit is by stairs (for a full description see building regulations approved document B). Why do I have to have a Disabled Refuge EVCS? The RRO, Regulatory Reform (Fire Safety) Order, is Government Legislation and an act of Parliament. The RRO requires a company to assess their Fire Safety systems which includes EVC Refuge systems on a regular basis commonly once every one or two years to make sure they comply with the CURRENT standards and regulations. The risk assessment of a building must be carried out to current standards not those when building systems were implemented. lso current Building Regulations insist that all new non-domestic buildings with more than one storey provide Refuge areas relatively safe places where people who cannot easily use fire escapes and evacuation lifts may call for assistance and wait until help arrives. Simple, effective two way communication (Refuge system) in these areas is essential; firstly to assist rescue teams in determining where assistance is required and secondly to reassure people help is on the way. What cables do I need? Compact 5 Line Exchange Unit (EVCS-CMPT) None Compact 9 Line Exchange Unit (EVCS-CMPT9) 4 core fire rated cable. Network System Network Master Handset (EVCS-MS), Network 8 Line Exchange Unit (EVCS-XC) 8 core fire rated cable - 1 off 4 pair, 2 off 4 core 1mm CS soft skin or 4 off 1 pair MICC twisted. Page 2 of 5 - EVCS_F_0712

Do I always have to use enhanced cables? Following the publication of BS5839 pt9: 2011, the guidance on cables for the EVCS has changed, following a relaxation in the requirements of the standard. Fire Fighting Telephone Systems ny system with Fire Fighting Telephones (Normally Type Outstations) must have all wiring to these outstations and any necessary network cables interconnecting parts of the system in Enhanced fire rated cables. Disabled Refuge Systems In buildings under 30 metres in height, or any building with sprinklers fitted, the wiring of Disabled Refuge points (normally Type B Outstation) may be in standard fire rated cable as long as the planned evacuation will be completed within 30 minutes. If the building is over 30 metres in height without sprinklers, or where the evacuation will take place over multiple stages exceeding 30 minutes, enhanced fire rated cables must be used. Network cables for systems comprising of purely Disabled Refuge Outstations configured as a ring may also be in standard fire rated cables. In BS5839 pt9-2011 section 14, the commentary suggests that in an EVCS intended for only Disabled Refuge the use of standard fire resistance cable may be acceptable provided the period specified for evacuation of the building is less than the fire rated duration of the cable. Disabled toilet call points. The revised BS5839 pt9: 2011 now recognises the addition of disabled toilet call systems to EVCS, however it gives no guidance on their use, as this is covered under Building Regulations pproved Document M. There is no requirement for these systems to be monitored or battery backed, however with the EVCS toilet extension we have included these features as standard. The only cable requirement may come from the building design statement, and typically this will require low smoke and fume cables (LSF), although they can also be wired in standard fire rated cable for ease of identification. Combined Systems When a system consists of a mix of Fire Fighting Outstations, the wiring must be enhanced, but individual spurs to Outstations dedicated solely for Disabled Refuge may be wired in standard fire-rated cable as long as the distance covered by that cable does not exceed 30 metres vertically in non sprinklered buildings, or the evacuation plan for this segment of the building will not exceed 30 minutes. General Guidance In complex buildings or where systems are being quoted without access to the fire evacuation plan we recommend all wiring to be enhanced, or suitable caveats and detailed assumptions are placed on the design certificate required by BS5839 pt9: 2011. Page 3 of 5 - EVCS_F_0712

Does an EVCS need a dedicated power supply? Yes, BS5839 PT 9 2011 13.1b The mains supply circuit(s) to all parts of the EVCS except outstations should be dedicated solely to the EVCS, and should serve no other systems or equipment. The circuit(s) should be derived from a point in the building s electrical distribution system close to the main isolating device for the building. Some Manufacturers state that their Type B Outstations can operate with high quality, full duplex speech in areas with up to 70dB of ambient noise Is this correct? BS5839 pt9: 2011 Outstations Section 2-11.16 s far as practicable, outstations in buildings should be located where background noise is normally low, preferably not more than 40 db(). Where there is a higher level of background noise in an emergency, the installation of an acoustic hood or structure around the outstation might help to reduce this to an acceptable level. Fire alarm sounders should not be located near to outstations. Note 1: The use of visual alarm devices instead of audible alarm devices may be appropriate, which may mean varying from the recommendations of BS 5839 1, in which case this should be documented. Note 2: BS 8300:2009, 9.1.2 gives advice on acoustic treatment of spaces and recommends that the recommendations of BS 8233 should be followed. Note: ll EVCS Type B outstations can also operate with up to 70db of ambient noise but this would be against the recommendations of BS5839 PT9 section 2-11.16 which states preferably not more than 40 db() Why on some Refuge Systems is the Master Station designed as a hands free unit? BS5839 pt9: 2011 Master stations Section 2-12.1 s a minimum, a master station will have a telephone style handset or microphone and loudspeaker for voice communication purposes, controls for making calls to, and receiving calls from, outstations, indicators to identify incoming calls, and fault and status indicators) For communication with outstations, a master station should have either: 1) a telephone-style handset; or 2) a noise-cancelling microphone mounted on a flexible or fixed arm with in-built windshield to prevent popping noises whilst speaking, and a separate panel- or desk-mounted loudspeaker. Note 1: Option 2) is the less desirable option. Note: ll Notifier EVCS Master Stations comply with a telephone style handset. Can a Type B Outstation have an Induction Loop? Yes, the Emergency Voice Communications System (EVCS) Type B Outstation has a line out for an induction loop which is an optional feature if required. There is no requirement under any legislation to have an induction loop fitted. It is down to the individual risk assessment of a building as to whether this would be of benefit to the people using it. The size of the loop amplifier will be decided by size of loop area. Page 4 of 5 - EVCS_F_0712

I only want the Refuge system to be activated by Fire Panel? n EVCS should not be dormant at any time and not activated by a fire panel. Please see notes below. BS5839 pt9: 2011 Section 11.5 k) Outstations provided for use by people at refuges should be readily available at all times and should not be secured. BS5839 pt9: 2011 Section 1 Clause 6 Variations from the recommendations of this standard state that EVCS should be in operation at all times and not just in a fire situation. ny deviations from this must be logged and agreed by all parties and must be clearly identified in all system documentation. Variations may arise from a fire risk assessment, or may be based upon the engineering judgment of a competent person. The competent person takes full responsibility under the RRO (fire safety) and is liable for deaths or injury resulting in their decisions under the corporate manslaughter act. refuge system is for the aid of disabled people at all times. The term disabled people can also include any person who is unable to safely use an exit route, e.g. people with back or sports injuries, pregnant women and those who cannot walk unaided. Some specifications are now asking for all Refuge calls including disabled toilets to be monitored by the same panel, can we do this? Yes, The Emergency ssist larm Kit is designed to be able to connect to a EVCS Master Refuge Panel by using one of the available lines and at no extra cost. This is connected via the ODI (over door Indicator) from each disabled toilet. Page 5 of 5 - EVCS_F_0712 Charles venue Burgess Hill W. Sussex RH15 9UF T: +44 (0) 116 246 2255 F: +44 (0) 116 246 2210 E: sales@notifierfiresystems.co.uk