Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832)



Similar documents
Agilent E5100A Network Analyzer

Agilent 8753ET/8753ES Network Analyzers

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Agilent 8720 Family Microwave Vector Network Analyzers

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Agilent Measuring Noninsertable Devices

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Agilent 4338B Milliohm Meter

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent E5063A ENA Series Network Analyzer

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Agilent 4339B/4349B High Resistance Meters

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Agilent Technologies 3000 Series Oscilloscopes

Impedance 50 (75 connectors via adapters)

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

HP 8753E RF Vector Network Analyzer

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

HP 8590 C/E/L/Q and EM Series Spectrum Analyzers and Accessories Configuration Guide

Improving Chromatic Dispersion and PMD Measurement Accuracy

FREQUENCY RESPONSE ANALYZERS

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Agilent PNA Network Analyzers 10 MHz to 110 GHz

Agilent U2000 Series USB Power Sensors

HDO700 P FIBRE OPTIC TRANSMITTER

E5092A Configurable Multiport Test Set

Agilent AN Improving Throughput in Network Analyzer Applications. Application Note

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Agilent 8590C/E Series Spectrum Analyzers and Accessories Configuration Guide

khz to 2.7 GHz Spectrum Analyzer

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

Agilent E6832A W-CDMA Calibration Application

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview

E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet

How To Use A Sound Card With A Subsonic Sound Card

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

Selecting RJ Bandwidth in EZJIT Plus Software

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent 8904A Multifunction Synthesizer dc to 600 khz

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

Cable Analysis and Fault Detection using the Bode 100

Keysight Technologies Drive Down the Cost of Test Using the ENA Series of Network Analyzers. Application Note

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

Modification Details.

Agilent 8509C Lightwave Polarization Analyzer

R&S ZNC Vector Network Analyzer Specifications

DSA800 Series Spectrum Analyzer

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

Multi-Range Programmable DC Power Supplies 9115 Series

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term

Agilent 8712ET/ES, 8714ET/ES RF Economy Network Analyzers Product Overview. Speed, accuracy, and productivity features, at a price you can afford

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Network analyzer and spectrum analyzer two in one

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

1.44 kw Programmable DC Power Supplies XLN Series

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Article from Micrel. A new approach to the challenge of powering cellular M2M modems By Anthony Pele Senior Field Applications Engineer, Micrel

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

GOOD WILL Instrument Co., Ltd. All rights reserved.

R&S ZNBT8 Vector Network Analyzer Specifications

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

R&S ZVA Vector Network Analyzer Specifications

Turbo X channel UHF true diversity

LT-82 Stationary IR Transmitter

ECONseries Low Cost USB DAQ

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

AN-837 APPLICATION NOTE

VME IF PHASE MODULATOR UNIT. mod

Calibration Guide. Agilent Technologies ESG Vector Signal Generator

R&S ZNC Vector Network Analyzer Solid performance on a future-oriented platform

IVIS IVIS - Indoor Video Insertion System

How To Sell A Talan

Agilent P940xA/C Solid State PIN Diode Switches

Chapter 5 Cubix XP4 Blade Server

Agilent 8762/3/4A,B,C Coaxial Switches

A Guide to Calibrating Your Spectrum Analyzer

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

GRF-3300 RF Training Kits

Field Calibration Software

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent E5100A/B Network Analyzer 10 khz to 180 MHz/300 MHz Product Overview Agilent s fastest analyzer improves production capability and reduces costs.

2

The Agilent Technologies E5100A/B network analyzers are most appropriately employed on production lines of electronic component manufacturers. They are especially well suited for crystal and ceramic resonator or filter manufacturers. These analyzers improve production line productivity with fast measurement speed, fast waveform analysis commands, and a high-speed processor. They provide faster measurements with lower fluctuations because of their low-noise performance and fineresolution IFBW. The E5100A (10 khz to 180/300 MHz) is a versatile and affordable network analyzer with many functions and options to fit your particular needs with a minimal investment. You can choose the 300 MHz version or the low-priced 180 MHz version. The E5100B (10 khz to 300 MHz) is a cost-effective analyzer that provides simple network measurements. It is well suited for in-process testing of crystal plating and for production adjustments. Major specifications of the E5100A/B Frequency range 10 khz 180 MHz/300 MHz Power (One RF OUT) 48 dbm to +22 dbm (option), 9 dbm to +11 dbm (standard) Measurement parameters Gain (Amplitude Ratio), Phase, Group-Delay, Amplitude, Gain- Phase, Gain-Delay IFBW 10 Hz 30 khz (1,1.5, 2, 3, 4, 5, 8 steps) Dynamic range 120 db (1FBW = 1 khz) (E5100A) Dynamic accuracy ±0.05 db, ±0.3 degrees Measurement speed 0.04 ms/point (IFBW = 30 khz, Ramp-sweep) Display 6.5-inch (diag.) color LCD Programming Instrument BASIC Mass storage FDD and internal non-volatile memory The E5100A/B adds value to resonator and filter production lines 0.04 ms/point measurement speed This fast speed increases throughput and reduces testing costs. Ramp sweep and step sweep Ramp sweep provides fast measurements without dead-time between points. Step sweep improves accuracy and stability because the analyzer pauses for signal output and receiver settling before making a measurement. Fine-resolution IFBW Seven IFBW choices per decade provide the best compromise between measurement time and data stability. Stable measurements The low-noise design of the Agilent E5100A/B allows a 120 db dynamic range and makes possible low-noise measurements. You get more stable data at wider IFBW settings. Fast processing A fast CPU shortens processing time and improves the total throughput. Waveform analysis commands and Instrument BASIC run even faster. Note: For detailed specifications refer to the E5100A/B datasheet (P/N 5966-2888E). Figure 1. The E5100A/B analyzers offer 0.4 ms/point measurement speed. 3

Options add capabilities Selectable number of receivers The number of receivers on the E5100A/B can be tailored to your needs so that the best instrument configuration can be chosen for each production line. The E5100A 300 MHz version can have up to 4 receivers; the E5100A 180 MHz version can have up to 3 receivers; and the E5100B can have up to 2 receivers. Selectable source output You can choose single, dual (builtin power splitter), or switched sources outputs (E5100A only). 50 Ω/1 MΩ switchable input impedance Input impedance of receivers A and B can be changed to 50 Ω/1 MΩ, switchable. 50 Ω fixed configuration is also available. Supports active probes Probe power sockets are installed on the front panel. Input connectors on receivers A and B can be changed to type-n for connecting active probes. (Standard is BNC.) Small-sized, lightweight Shorter depth The E5100 s short depth (425 mm) allows a larger work area in front of the instrument. Lightweight Weighing just 12 kg (typical), the analyzers are easy to move when production line layouts change. Other features PC-compatible external keyboard and external CRT The external DIN keyboard and the external display output (VGA) are compatible with popular personal computers. 3-mode DOS floppy disk drive The built-in FDD supports 3 modes: 720 kbyte (2DD), 1.2 Mbyte, and 1.44 Mbyte (2HD) DOS formats. The E5100A a great fit for productions line final tests During final tests, both precision and high-speed are required for better yield and better productivity. The Agilent E5100A makes high-quality, high-speed tests with its fine IFBW resolution and lownoise circuitry. Its convenient analysis and processing functions improve the productivity of finaltest processes. Low-cost 180 MHz version The E5100A 180 MHz version is the economical solution for lower frequency applications. The test frequency range is 10 khz to 180 MHz. It provides the same measurement performance and measurement speed as the 300 MHz version with lower prices. Note: The frequency type of the E5100A (180 MHz or 300 MHz) is selected by specifying the receiver options. Optical-isolated parallel I/O A TTL-level parallel interface is standard for interfacing with autohandlers. For noise immunity, an optical-isolated, open-collector parallel I/O is available. Table 1. Comparison of E5100A/B versions E5100A E5100A 300 MHz version 180 MHz version E5100B Test frequency 10 khz 300 MHz 10 khz 180 MHz 10 khz 300 MHz Number of receivers 1 to 4 1 to 3 1 to 2 E5100A-100 E5100A-118 E5100B-100 E5100A-200 E5100A-218 E5100B-200 E5100A-300 E5100A-318 E5100A-400 Measurement points 2 to 1601 2 to 1601 2 to 401 List sweep Yes Yes No Dynamic range 120 db 120 db 100 db Phase tracking DLD function Yes (E5100A-023) Yes (E5100A-823) No Evapolation monitor function Yes (E5100A-022) No Yes (E5100B-022) 4

Resonator tests High-speed evaluation using waveform analysis commands The waveform analysis commands of the E5100A perform accurate parameter extraction in a very short time. For example, a single command simultaneously extracts resonant frequency and impedance. The analyzer also has other commands for complex tests of resonators, such as equivalent circuit analysis, peak-search, rippleanalysis, etc. (see figure 2). Phase Tracking function improves throughput of DLD measurement The E5100A network analyzer with Opt.E5100A-823 and E5100A-023 is a good solution for measuring the drive level dependency (DLD) of crystals. This option provides a very quick measurement because it measures only the resonant frequency (Fr) and the resonant impedance (CI) as it sweeps the drive level (see figure 4). For crystal resonator tests with a PI network The E5100A supports high-frequency crystal resonator tests using the 41900A/41901A PI network fixture. The E5100A with Opt. E5100A-618 and E5100A-600 has dual source output ports with different power levels. RF OUT-1 provides higher power for the receiver port A and RF OUT-2 provides lower power for the receiver port R. This capability allows the E5100A to apply a 1-mW drive level (when CI is 25 Ω) even when the PI network test fixture with large attenuation is used. In addition, it is not necessary to connect an external attenuator to the receiver port R. Accuracy can be increased by eliminating residual impedance and stray admittance around the fixture using the transmission threeterm calibration of the E5100A and the furnished calibration kits of the 41900A/41901A. Resonator tests with load capacitors can also be performed with the 41900A/ 41901A s load capacitor adapter kit. [Watt] and [Amp] are available to set output power The drive level of crystal resonators is normally defined as power [Watt] or current [Amp]. The E5100A has a convenient function to set the drive level in Watts or Amperes with nominal crystal impedance. No calculator is needed to convert dbm to Watt or Ampere. Figure 2. Example of equivalent circuit analysis of a resonator Figure 3. Crystal resonator test with a PI network Figure 4. Example of DLD measurement using Opt. E5100A-823 and E5100A-023 phase tracking function 5

For filter tests Effective filter tests using list sweep The Agilent E5100 s list sweep capability reduces sweep time on filters. The test frequency range of filters varies depending on the rejection band, the pass band, and the user s specifications. The list sweep capability operates over various frequency ranges. The sweep frequency range is separated into segments, each of which can have an independent frequency range, number of sweep points, IFBW, and power level settings. By using list sweep, separate frequency bands can be measured in one sweep, or a different IFBW can be set for pass band and rejection band. Wide dynamic range measurements can be completed less time. Efficient spurious detection When detecting high-q spurs, narrow-span sweeps are necessary after wide-span sweeps, but changing the span degrades the test throughput. The E5100A s short setup changing time improves test efficiency (see figure 6). Quick and easy filter parameter extraction The E5100A can analyze data quickly using the built-in waveform analysis commands. These commands provide parameters within the pass band (such as insertion loss, 3 db bandwidth) or parameters within the rejection band. Many commands for analyzing pass-band ripple or groupdelay time are also available (see figure 7). Figure 5. Example of list sweep for filter test Figure 6. Spurious measurement results (top: wide span, bottom: narrower span) 6

Improving filter adjustment productivity When manually adjusting filters, the E5100A s quick display of the filter response (waveform) and pass/fail results improve productivity. An external VGA monitor can be connected to the analyzer for an even larger display that reduces operator fatigue. For other applications Incoming inspection The Agilent E5100A can be used for incoming inspection of filters and resonators. When inspecting many kinds of devices, the built-in floppy disk drive and non-volatilememory are useful for saving and recalling test conditions, calibration data, and test data. Adjustments of active components and electronic circuits The E5100A s fast sweep allows rapid adjustments of filter circuitry or active devices such as amplifiers or modulators. The E5100B-best for in-process testing of filters and resonators The requirements of in-process testing differ from those of final test. In-process tests must be quick and low cost. The E5100B network analyzer has the same measurement quality and speed as the E5100A, but provides less functionality. The E5100B reduces production costs and is a valuable tool for in-process testing. Figure 8. An external monitor can be used to reduce operator eye strain and fatigue. For blank crystal tests The demand for higher-frequency crystal components is growing, which means blank crystals are thinner. When an oscillator and a frequency counter are used to test these higher-frequency crystals, the results aren t accurate. The E5100B s fast measurement speed of 0.04 ms/pt and fast waveform analysis commands improves crystal test productivity. For vacuum evaporation testing (frequency adjustment) of crystals The E5100B is an ideal process monitoring tool for the vacuum evaporation process of crystal resonators and filers. It outputs information necessary to control the process in a real-time manner, so evaporation chamber throughput and adjustment accuracy can be improved. Opt. E5100B-022, the evaporation monitoring function, is a good solution for adjustment of crystal resonators. 7

Configuration information for the E5100A network analyzer Choose the option group <A> or <B> depending on your measurement needs, then choose the appropriate options within the group chosen. Lastly, choose the appropriate options from the option group <C>. = Choose ONE and ONLY one (Options are mutually exclusive) = Choose any combination <A> For crystal resonator test function E5100A-600 300MHz X tal resonator test w/pi-network E5100A-618 180MHz X tal resonator test w/pi-network <B> For generic test (including ceramic resonator test, filter test) function Step 1: Choose an RF Out option E5100A-001 One RF OUT port E5100A-002 Two RF OUT ports, built in power splitter E5100A-003 Two RF OUT ports, switched single output E5100A-801 Power extended one RF OUT port E5100A-802 Power extended Two RF OUT ports, built-in power splitter E5100A-803 Power extended two RF OUT ports, switched single output Step 2: Choose a number of ports option E5100A-100 300MHz, 1 receiver, port A E5100A-118 180MHz, 1 receiver, port A E5100A-200 300MHz, 2 receivers, ports R and A E5100A-218 180MHz, 2 receivers, ports R and A E5100A-300 300MHz, 3 receivers, ports R, A and B E5100A-318 180MHz, 3 receivers, ports R, A and B E5100A-400 300MHz, 4 receivers, ports R, A, B and C Step 3: Choose a connector type option. E5100A-701 Type-BNC 50 Ω input connector on port A E5100A-702 Type-BNC 50 Ω input connector ports A and B E5100A-703 Type-BNC 50/ 1 MΩ selectable input on port A E5100A-704 Type-BNC 50/ 1 MΩ selectable input on port A and B E5100A-705 Type-N 50 Ω input connector on port A E5100A-706 Type-N 50 Ω input connectors, ports A and B E5100A-707 Type-N 50/1 MΩ selectable input on port A E5100A-708 Type-N 50/1 MΩ selectable inputs, port A and B Note: Options E5100A-701, 703, 705, and 707 are for Options E5100A-100, 118, 200 and 218 only. Options E5100A-702, 704, 706, and 708 are for Options E5100A-300, 318 and 400 only. Options E5100A-703, 704, 707, and 708 cannot be ordered with Option E5100A-003 or 803. <C> Common Functions Step 1: Would you like a special measurement function? No special measurement function needed E5100A-022 Evaporation monitoring function (300 MHz option only) E5100A-023 Phase tracking function for 300 MHz ver. E5100A-823 Phase tracking function for 180 MHz ver. Note: Option E5100A-022 is for Options E5100A-100, 200, 300 and 400 only. Option E5100A-023 is for Options E5100A-200, 300, and 400 only. Option E5100A-823 is for Options E5100A-218 and 318 only. Step 2: Would you like to change the I/O? No. (standard 24 bit I/O) E5100A-005 Parallel I/O mode A E5100A-006 Parallel I/O mode B E5100A-007 Opto-isolated parallel I/O Step 3: Would you like a high stability frequency reference? E5100A-1D5 High stability frequency reference Step 4: Would you like to delete any standard accessories? E5100A-UKR Delete instrument BASIC Step 5: Would you like a PC style keyboard? E5100A-1F0 PC style keyboard - U.S. version Step 6: Would you like any rack mount accessories? E5100A-1CM Rackmount kit E5100A-1CN Handle kit E5100A-1CP Rackmount and handle kit Step 7: Choose a language of the manual or delete a manual set. E5100A-ABA U.S. - English E5100A-ABJ Japan - Japanese E5100A-0B0 Delete manual set Step 8: Would you like additional manual sets? E5100A-0B1 Additional manual set E5100A-ABA U.S. - English E5100A-ABJ Japan - Japanese 8

Configuration information for the E5100B network analyzer Step 1: Choose an RF out option E5100B-001 One RF OUT port E5100B-002 Two RF OUT ports, built in power splitter E5100B-801 Power extended one RF OUT port E5100B-802 Power extended two RF OUT ports, built-in power splitter Step 2: Choose a number of ports option E5100B-100 300 MHz, 1 receiver, port A E5100B-200 300 MHz, 2 receivers, ports R and A Step 3: Choose a connector type option. E5100B-701 Type-BNC 50 Ω input connector on port A E5100B-703 Type-BNC 50/ 1 MΩ selectable input on port A E5100B-705 Type-N 50 Ω input connector on port A E5100B-707 Type-N 50/1 MΩ selectable input on port A E5100B-1CN Handle kit E5100B-1CP Rackmount and handle kit Step 10: Choose a language of the manual or delete a manual set E5100B-ABA U.S. - English E5100B-ABJ Japan - Japanese E5100B-0B0 Delete manual set Step 11: Would you like additional manual sets? E5100B-0B1 Additional manual set E5100B-ABA U.S. - English E5100B-ABJ Japan - Japanese Step 4: Would you like a special measurement function? E5100B-022 Evaporation monitoring function Step 5: Would you like to change the I/O? No, standard 24 bit I/O E5100B-005 Parallel I/O mode A E5100B-006 Parallel I/O mode B E5100B-007 Opto-isolated parallel I/O Step 6: Would you like a high stability frequency reference? E5100B-1D5 High stability frequency reference Step 7: Would you like to delete any standard accessories? E5100B-UKR Delete instrument BASIC Step 8: Would you like a PC style keyboard? E5100B-1F0 PC style keyboard - U.S. version Step 9: Would you like any rack mount accessories? E5100B-1CM Rackmount kit 9

Accessories 41800A Active probe 41802A 1 MΩ input adapter 41900A PI-network test fixture 41900A-001 Variable CL adapter kit 41901A SMD PI-network test fixture Fixed CL adapter options 41901A-010 Attachment kit QIAJ- (fixed) 41901A-020 Attachment kit QIAJ- QS06 2-terminal type (fixed) 41901A-030 Attachment kit QIAJ- QS07 4-terminal type (fixed) 41901A-040 Attachment kit QIAJ- QS07 2-terminal type (fixed) 41901A-050 Attachment kit QIAJ- QS08 4-terminal type (fixed) 41901A-060 Attachment kit QIAJ- QS08 2-terminal type (fixed) Variable CL adapter options 41901A-011 Attachment kit QIAJ- (variable) 41901A-021 Attachment kit QIAJ- (variable) 41901A-031 Attachment kit QIAJ- (variable) 41901A-041 Attachment kit QIAJ- (variable) 41901A-051 Attachment kit QIAJ- (variable) 41901A-061 Attachment kit QIAJ- (variable) 87512A Transmission/ reflection test kit 118500 50 Ω three-way power splitter 10

11

Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test and measurement needs Online assistance: www.agilent.com/find/assist Phone or Fax United States: (tel) 800 452 4844 Canada: (tel) 877 894 4414 (fax) 905 282 6495 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6836 0252 Email: tm_asia@agilent.com Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2002 Printed in USA, June 5, 2002 5968-1873E