Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note



Similar documents
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Make Better RMS Measurements with Your DMM

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Evaluating Oscilloscope Bandwidths for Your Application

Agilent E5063A ENA Series Network Analyzer

Keysight Technologies Drive Down the Cost of Test Using the ENA Series of Network Analyzers. Application Note

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

Keysight E5063A ENA Series PCB Analyzer

Keysight Technologies How to Choose your MAC Lever. Technical Overview

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight N9320B RF Spectrum Analyzer

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

Agilent FieldFox Remote Viewer

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Keysight Technologies Quickly Identify and Characterize Thermal Measurement Points

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

802.11ac Power Measurement and Timing Analysis

Keysight N6854A Geolocation System. Configuration Guide

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

The Next Generation in Automated Oscilloscope Test

Keysight Technologies Solutions for WLAN ac Manufacturing Test

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

DDR Memory Overview, Development Cycle, and Challenges

Agilent U2000 Series USB Power Sensors

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Keysight Technologies AC6800 Series Basic AC Power Sources. Data Sheet

Agilent U2000 Series USB Power Sensors

Agilent P940xA/C Solid State PIN Diode Switches

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Impedance 50 (75 connectors via adapters)

An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices

Agilent 4338B Milliohm Meter

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Agilent 87421A/87422A Power Supply

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Keysight Technologies Drive Down the Cost of Test Using the ENA Series of Network Analyzers. Application Note

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

Application Note Noise Frequently Asked Questions

PXI and AXIe Modular Instrumentation

Agilent U2000 Series USB Power Sensors

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

TDA W Hi-Fi AUDIO POWER AMPLIFIER

RF Network Analyzer Basics

AN2604 Application note

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Agilent E6832A W-CDMA Calibration Application

PXI and AXIe Modular Instrumentation

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent OSS Customer-Centric Service Manager

1.5 GHz Active Probe TAP1500 Datasheet

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

TDA4605 CONTROL CIRCUIT FOR SWITCH MODE POWER SUPPLIES USING MOS TRANSISTORS

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Agilent 4339B/4349B High Resistance Meters

WD Hard Drive Interface Guide

The Role of Banks in Global Mergers and Acquisitions by James R. Barth, Triphon Phumiwasana, and Keven Yost *

Thomson Video Networks Contact Center Guide

TDS5000B, TDS6000B, TDS/CSA7000B Series Acquisition Modes

L4940 series VERY LOW DROP 1.5 A REGULATORS

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Automatic compression measurement using network analyzers

LM337. Three-terminal adjustable negative voltage regulators. Features. Description

Symbol Parameter Value Unit V i-o Input-output Differential Voltage 40 V I O Output Current Intenrally Limited Top

High-Speed Inter Connect (HSIC) Solution

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

Description. Table 1. Device summary. Order codes. TO-220 (single gauge) TO-220 (double gauge) D²PAK (tape and reel) TO-220FP

One Port Network Analyzer

Understanding Noise Figure

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Description. Table 1. Device summary

TDA CHANNEL VOLUME CONTROLLER 1 FEATURES 2 DESCRIPTION. Figure 1. Package

Agilent Test Solutions for Multiport and Balanced Devices

Evaluating Oscilloscope Sample Rates vs. Sampling Fidelity

Simulating Envelope Tracking with Keysight Advanced Design System. Application Note

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Supported Payment Methods

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

2015 Growth in data center employment continues but the workforce is changing

Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer

ADJUSTABLE VOLTAGE AND CURRENT REGULATOR

UA741. General-purpose single operational amplifier. Features. Applications. Description. N DIP8 (plastic package)

Transcription:

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range Application Note

Introduction Achieving the highest possible network analyzer dynamic range is extremely important when characterizing many types of microwave devices, and in some cases the key factor in determining measurement performance. To achieve the greatest dynamic range from a network measurement system, it is important to understand the essence of dynamic range and the methods that can be employed to increase it. Armed with this knowledge, the designer can choose the method that achieves the best results with the least impact on other instrument parameters such as measurement speed. Network analyzer dynamic range is essentially the range of power that the system can measure, speciically: P max : The highest input power level that the system can measure before unacceptable errors occur in the measurement, usually determined by the network analyzer receiver's compression speciication. P ref : The nominal power available at the test port from the network analyzer's source. P min : The minimum input power level the system can measure (its sensitivity), set by the receiver's noise loor. P min depends on the IF bandwidth, averaging, and the test set coniguration. The two common deinitions for dynamic range are: Receiver dynamic range = P max P min System dynamic range = P ref P min P max Achievable dynamic range depends upon the measurement application as shown in Figure 1. System dynamic range: The dynamic range that can be realized without ampliication such as when measuring passive components such as attenuators and ilters. Receiver dynamic range: The system s true dynamic range if it is considered a receiver. An ampliier may be required to realize the receiver s full dynamic range. This can be the device under test or an external ampliier added to the measurement system. P ref P min Figure 1. System Dynamic Range Receiver Dynamic Range

3 Keysight Understanding and Improving Network Analyzer Dynamic Range Application Note Noise loor deined The receiver's noise loor is an important network analyzer speciication that helps determine its dynamic range. Unfortunately, noise loor is not a well-deined term and it has been deined several ways over the years. The results of an experiment to compare some common noise loor deinitions are shown in Figure 2. In this experiment, Gaussian random noise with a noise power of 100 dbm was simulated, and the noise loor was calculated using four deinitions: The solid line shows the RMS value of the noise, which is equal to the noise power of 100 dbm. The dashed line ( 101 dbm) is the mean value of the linear magnitude of the noise, converted to dbm. The dotted line ( 102.4 dbm) is the mean value of the log magnitude of the noise. The dot-dash line ( 92.8 dbm) is the sum of the mean value of the linear magnitude of the noise and three times its standard deviation, converted to dbm. Improving dynamic range In some measurement situations, it is desirable to increase the network analyzer s dynamic range beyond the level obtained with the default settings. Noise loor sets the minimum power level that the instrument can measure and thus limits its dynamic range. Noise loor can be improved by using averaging, or by reducing the system bandwidth (IF BW). Smoothing is another technique that is often considered to be akin to averaging and IF BW adjustment, but it does not reduce the noise loor. Smoothing is adjacent-point averaging of the formatted data, similar to video iltering. Trace-to-trace (or sweepto-sweep) averaging operates on the pre-formatted, vector data, so that it can actually reduce the noise power. This key difference is responsible for the inability of smoothing to reduce noise loor, although it does reduce small peak-to-peak variations of noise on a trace. 1 Keysight Technologies s new PNA series vector network analyzers use the RMS value to deine receiver noise loor. This is a commonly used deinition, and is easy to understand because it is the receiver's equivalent input noise power. Figure 2. Various noise loor deinitions

4 Keysight Understanding and Improving Network Analyzer Dynamic Range Application Note Averaging The PNA Series and many other network analyzers perform sweep-to-sweep averaging by taking an exponentially weighted average of the data points from each sweep. Exponen-tially weighting the samples in the data set allows averaging to proceed without termination, even after the desired averaging factor has been reached. The averaging is performed on complex data, which means that the data is averaged vectorially. Many signal analyzers use scalar averaging, which mitigates only the variance of the noise but does not affect the average noise level. When a trace that contains both coherent signal and uncorrelated noise is averaged in the vector sense, the noise component will approach zero, and the resulting trace will show the desired signal with less noise present. When viewed with the log magnitude format on the network analyzer display, it becomes clear that the average noise level is reduced and an improvement in dynamic range is achieved. Using the averaging function available in most vector network analyzers, signal-to-noise ratio is improved by 3 db for every factor-of-2 increase in averages. This is a powerful method for reducing noise loor. However, it also reduces measurement speed because when two traces must be averaged, measurement time doubles. Averaging can only be used on ratioed measurements, and will not work on measurements using a single receiver channel. Averaging is not allowed on unratioed measurements because phase is random in this mode and averaging (which is performed in the complex domain), will always cause the result to approach zero. IF BW reduction The IF BW of the system can be altered via the front panel or remote programming, and its value will affect the digital iltering that is performed on the data collected in the analyzer s receivers. Decreasing IF BW will reduce noise loor by iltering out noise that is outside the bandwidth of the digital ilter. The low level noise that is present in the analyzer s receiver chain is caused by thermal noise arising from the thermal agitation of electrons in resistances. Consequently, it is directly proportional to bandwidth. The mean-square value of the thermal noise voltage is given by: E 2 = 4RkTB where k is Boltzmann's constant (1.38 e-23 joules/kelvin) T is the absolute temperature in degrees Kelvin R is the resistive component in ohms B is the bandwidth in Hertz The noise power delivered to a complex conjugate load is Pn = E 2 = ktb 4R This is the familiar ktb relationship for noise power 2. Noise is random in nature and is considered nondeterministic because it is caused by a collection of small events and exhibits a Gaussian probability distribution (which can be proved by the central limit theorem 3 ). Figure 3. RMS noise loor vs IF BW (n=801 pts) A high level of conidence in the relationship between noise loor and IF BW makes it possible to precisely calculate the noise loor reduction achieved by decreasing the IF BW. An empirical study was performed using the PNA network analyzer in which the RMS noise level was measured at 5 different CW frequencies (1, 3, 5, 7, and 9 GHz). There were 801 points in the sweep and the IF BW was set to 1 Hz, 10 Hz, 100 Hz, 1 khz, and 10 khz. The noise loor of the VNA was measured with no signal present at the test ports. In Figure 3, the observed relationship between the noise loor and the IF BW shows that the PNA s RMS noise loor very closely follows the theoretical expectation. Deviation from theory is negligible. As with averaging, decreasing IF BW to reduce noise loor reduces measurement speed. While it could be expected that a factor-of-10 decrease in IF BW will reduce the noise loor by 10 db and will cause a factor-of-10 increase in measurement time, this is not always true because the digital ilters used in a network analyzer at different IF bandwidths may vary in shape. In the PNA Series for example, sweep time increases by a factor that is less than 10 for a factor-of-10 reduction in IF BW. This means that to achieve the same reduction in noise loor, IF BW reduction will reduce measurement speed less than will averaging.

5 Keysight Understanding and Improving Network Analyzer Dynamic Range Application Note Choosing the best method To achieve noise loor reduction, averaging can be increased or IF BW reduced. If measurement speed is not of paramount concern, either method will work equally well. The time required to acquire and process data for a trace (called cycle time), includes not only sweep time, but also retrace time, band-crossing time, and display update time. Since averaging requires taking multiple traces and updates the display every time, it generally takes slightly longer to use averaging than IF BW reduction, especially if many averages are required. It is important to remember that much of the difference in impact on measurement time is caused by the digital iltering performed for the various IF BWs. This effect manifests itself in the sweep time component of the cycle time, so to determine the effect of the two noise-loor-reduction methods on measurement time, it is appropriate to consider sweep time only. Consider the PNA Series set up in a 10 KHz IF BW. If an improvement of 10 db is desired in dynamic range, it can be achieved by averaging 10 sweeps or setting the IF BW to 1 KHz. Table 1 shows the effect on sweep time for the two approaches to achieve a dynamic range improvement of 10 or 20 db. The increase in cycle time closely parallels the increase in sweep time, and it is evident that using IF BW reduction to attain increased dynamic range has an advantage over averaging in terms of impact on measurement speed if the network analyzer is in a fast sweep mode. With a slow sweep mode, impact on measurement speed is essentially the same for either of the two methods. There are other factors that can be considered when deciding which method to choose for increasing dynamic range in a given measurement application. Using averaging to reduce noise loor allows the user to observe the traces on the PNA screen as the averaging progresses, which some designers may ind useful. IF BW reduction works on both ratioed and unratioed measurements (unlike averaging which only works in ratioed mode), which can be the determining factor in some situations. The PNA Series provides a large number of IF BWs to choose from, which gives the designer wide lexibility in desired noise loor reduction while incurring the smallest possible reduction in measurement speed. In many situations, dynamic range can be increased by using both averaging and IF BW adjustment. Table 1 Sweep time impact with fast IF BWs Noise loor reduction (db) 10 KHz 10 averages 10 10 1 KHz 0 averages 10 7.75 10 KHz 100 averages 20 100 100 Hz 0 averages 20 74.8 Sweep time increase factor This example uses a fairly fast IF BW, and shows that IF BW reduction produces a beneit over averaging when attempting to improve dynamic range. However, now consider a slower sweep mode (i.e., lower IF BW). If the PNA is set at an IF BW of 100 Hz and a noise loor reduction of 10 db is desired, averaging with a factor of 10 can be applied, or the IF BW can be reduced to 10 Hz. Table 2 shows the impact on sweep time. Table 2 Sweep time impact with slow IF BWs Noise loor reduction (db) 100 Hz 10 averages 10 10 10 Hz 0 averages 10 9.9 100 Hz 100 averages 20 100 1 Hz 0 averages 20 99.5 Sweep time increase factor

6 Keysight Understanding and Improving Network Analyzer Dynamic Range Application Note Dynamic range, segmented sweep and the conigurable test set For applications in which speed and wide dynamic range must both be optimized, the segmented sweep feature available on some network analyzers is useful. This feature is extremely valuable when measuring ilters that demand simultaneous characterization of the passband at a high power level, and the reject band at a very low power level. Segmented sweep allows the user to break a frequency sweep into multiple segments, each with its own stop and start frequency, IF BW, power level, and number of points. When measuring a ilter, the IF BW in the passband can be set wider for a fast sweep rate, as long as high level trace noise is kept suficiently small. In the reject band, where noise loor contributes signiicantly to measurement error, the IF BW can be set low enough to achieve the desired reduction in average noise level. To increase the dynamic range of the analyzer even further, segmented sweep can be used in conjunction with a re-coniguration of the test-set (Figure 4). An increase in dynamic range of 12 to 15 db can be achieved with this method by reversing the directional coupler in the receiving test port. Summary Network analyzer dynamic range is the most critical parameter in many measurement situations, and it can be increased by reducing noise loor through averaging or IF BW reduction. However, each method has disadvantages that determine its suitability in certain cases, and has a unique effect on measurement speed. Beyond these two methods, further dynamic range improvement can be obtained and measurement speed retained by using the segmented sweep feature found in network analyzers such as Keysight s PNA Series, as well as a conigurable test set. References 1. Robert A. Witte,"Spectrum and Network Measurements," Upper Saddle River, New Jersey, Prentice Hall PTR, Inc., 1993. 2. H.L. Krauss, C.W. Bostian and F.H. Raab, "Solid State Radio Engineering," New York, NY: John Wiley & Sons, Inc. 1980, pp. 11-24. 3. Alberto Leon-Garcia, "Probability and Random Process for Electrical Engineering," 2nd ed., New York, NY: Addison-Wesley Publishing Company, Inc., 1994. Source Switch/Splitter/Leveler R1 Reference Reference Receiver Receiver 70 db 70 db R2 A B 36 db Measurement Receivers 36 db R1 R1 Source Coupler A A B B Coupler Source R2 R2 Figure 4. DUT

7 Keysight Understanding and Improving Network Analyzer Dynamic Range Application Note mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Electronic Measurement Group DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. This document was formerly known as application note number 1363-1 www.keysight.com/find/assist For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Paciic Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-06-23-14) This information is subject to change without notice. Keysight Technologies, 2000-2014 Published in USA, July 31, 2014 5980-2778EN www.keysight.com